暖通空调专业 毕业设计外文翻译5_第1页
暖通空调专业 毕业设计外文翻译5_第2页
暖通空调专业 毕业设计外文翻译5_第3页
暖通空调专业 毕业设计外文翻译5_第4页
暖通空调专业 毕业设计外文翻译5_第5页
已阅读5页,还剩9页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、英文翻译Chilled Water Systems1Chilled water systems were used in less than 4% of commercial buildings in the U.S. in 1995. However, because chillers are usually installed in larger buildings, chillers cooled over 28% of the U.S. commercial building floor space that same year (DOE, 1998). Five types of c

2、hillers are commonly applied to commercial buildings: reciprocating, screw, scroll, centrifugal, and absorption. The first four utilize the vapor compression cycle to produce chilled water. They differ primarily in the type of compressor used. Absorption chillers utilize thermal energy (typically st

3、eam or combustion source) in an absorption cycle with either an ammonia-water or water-lithium bromide solution to produce chilled water.Overall SystemFigure 4.2.2 shows a simple representation of a dual chiller application with all the major auxiliary equipment. An estimated 86% of chillers are app

4、lied in multiple chiller arrangements like that shown in the figure (Bitondo and Tozzi, 1999). In chilled water systems, return water from the building is circulated through each chiller evaporator where it is cooled to an acceptable temperature (typically 4 to 7°C) (39 to 45°F). The chill

5、ed water is then distributed to water-to-air heat exchangers spread throughout the facility. In these heat exchangers, air is cooled and dehumidified by the cold water. During the process, the chilled water increases in temperature and must be returned to the chiller(s).The chillers shown in Figure

6、4.2.2 are water-cooled chillers. Water is circulated through the condenser of each chiller where it absorbs heat energy rejected from the high pressure refrigerant. The water is then pumped to a cooling tower where the water is cooled through an evaporation process. Cooling towers are described in a

7、 later section. Chillers can also be air cooled. In this configuration, the condenserwould be a refrigerant-to-air heat exchanger with air absorbing the heat energy rejected by the high pressure refrigerant.Chillers nominally range in capacities from 30 to 18,000 kW (8 to 5100 ton). Most chillers so

8、ld in the U.S. are electric and utilize vapor compression refrigeration to produce chilled water. Compressors for these systems are either reciprocating, screw, scroll, or centrifugal in design. A small number of centrifugal chillers are sold that use either an internal combustion engine or steam dr

9、ive instead of an electric motor to drive the compressor. 1节选自James B. Bradford et al. “HVAC Equipment and Systems”.Handbook of Heating, Ventilation, and Air-Conditioning.Ed. Jan F. Kreider.Boca Raton, CRC Press LLC. 2001浙 江 海 洋 学 院 毕 业 设 计FIGURE 4.2.2 A dual chiller application with major auxiliary

10、 systems (courtesy of Carrier Corporation).The type of chiller used in a building depends on the application. For large officebuildings or in chiller plants serving multiple buildings, centrifugal compressors are often used. In applications under 1000 kW (280 tons) cooling capacities, reciprocating

11、or screw chillers may be more appropriate. In smaller applications, below 100 kW (30 tons),reciprocating or scroll chillers are typically used.Vapor Compression ChillersTable 4.2.5 shows the nominal capacity ranges for the four types of electrically driven vapor compression chillers. Each chiller de

12、rives its name from the type of compressor used in the chiller. The systems range in capacities from the smallest scroll (30 kW; 8 tons) to the largest centrifugal (18,000 kW; 5000 tons).Chillers can utilize either an HCFC (R-22 andR-123) or HFC (R-134a) refrigerant. The steady state efficiency of c

13、hillers is often stated as a ratio of the power input (in kW) to the chilling capacity (in tons). A capacity rating of one ton is equal to 3.52 kW or 12,000 btu/h. With this measure of efficiency, the smaller number is better. As seen in Table 4.2.5, centrifugal chillers are the most efficient; wher

14、eas,reciprocating chillers have the worst efficiency of the four types. The efficiency numbers provided in the table are the steady state full-load efficiency determined in accordance to ASHRAE Standard 30 (ASHRAE, 1995). These efficiency numbers do not include the auxiliary equipment, such as pumps

15、 and cooling tower fans that can add from 0.06 to 0.31 kW/ton to the numbers shown (Smit et al., 1996).Chillers run at part load capacity most of the time. Only during the highest thermal loads浙 江 海 洋 学 院 毕 业 设 计in the building will a chiller operate near its rated capacity. As a consequence, it is

16、important to know how the efficiency of the chiller varies with part load capacity. Figure 4.2.3 shows a representative data for the efficiency (in kW/ton) as a function of percentage full loadcapacity for a reciprocating, screw, and scroll chiller plus a centrifugal chiller with inlet vane control

17、and one with variable frequency drive (VFD) for the compressor. The reciprocating chiller increases in efficiency as it operates at a smaller percentage of full load. In contrast, the efficiency of a centrifugal with inlet vane control is relatively constant until theload falls to about 60% of its r

18、ated capacity and its kW/ton increases to almost twice its fullyloaded value.FIGURE 4.2.3 Chiller efficiency as a function of percentage of full load capacity.In 1998, the Air Conditioning and Refrigeration Institute (ARI) developed a newstandard that incorporates into their ratings part load perfor

19、mance of chillers (ARI 1998c). Part load efficiency is expressed by a single number called the integrated part load value (IPLV). The IPLV takes data similar to that in Figure 4.2.3 and weights it at the 25%, 50%, 3浙 江 海 洋 学 院 毕 业 设 计75%, and 100% loads to produce a single integrated efficiency numb

20、er. The weighting factorsat these loads are 0.12, 0.45, 0.42, and 0.01, respectively. The equation to determine IPLV is:.FIGURE 4.2.4 Volume-pressure relationships for a reciprocating compressor.The four compressors used in vapor compression chillers are each briefly describedbelow. While centrifuga

21、l and screw compressors are primarily used in chiller applications, reciprocating and scroll compressors are also used in smaller unitary packaged airconditioners and heat pumps.Reciprocating CompressorsThe reciprocating compressor is a positive displacement compressor. On the intakestroke of the pi

22、ston, a fixed amount of gas is pulled into the cylinder. On the compression 4浙 江 海 洋 学 院 毕 业 设 计stroke, the gas is compressed until the discharge valve opens. The quantity of gas compressed on each stroke is equal to the displacement of the cylinder. Compressors used in chillers have multiple cylind

23、ers, depending on the capacity of the compressor. Reciprocating compressors use refrigerants with low specific volumes and relatively high pressures. Most reciprocating chillers used in building applications currently employ R-22.Modern high-speed reciprocating compressors are generally limited to a

24、 pressure ratio of approximately nine. The reciprocating compressor is basically a constant-volumevariable-head machine. It handles variousdischarge pressures with relatively small changes in inlet-volume flow rate as shown by the heavy line (labeled 16 cylinders) in Figure 4.2.4. Condenser operatio

25、n in many chillers isrelated to ambient conditions, for example, through cooling towers, so that on cooler days the condenser pressure can be reduced. When the air conditioning load is lowered, less refrigerant circulation is required. The resulting load characteristic is represented by the solid li

26、ne that runs from the upper right to lower left of Figure 4.2.4.The compressor must be capable of matching the pressure and flow requirementsimposed by the system. The reciprocating compressor matches the imposed dischargepressure at any level up to its limiting pressure ratio. Varying capacity requ

27、irements can be met by providing devices that unloadindividual or multiple cylinders. This unloading is accomplished by blocking the suction or discharge valves that open either manually or automatically. Capacity can also be controlled through the use of variable speed or multi-speed motors. When c

28、apacity control isimplemented on a compressor, other factors at part-load conditions need to considered, such as (a) effect on compressor vibration and sound when unloaders are used, (b) the need for good oil return because of lower refrigerant velocities, and (c) proper functioning ofexpansion devi

29、ces at the lower capacities.With most reciprocating compressors, oil is pumped into the refrigeration system from the compressor during normal operation. Systems must be designed carefully to return oil to the compressor crankcase to provide for continuous lubrication and also to avoidcontaminating

30、heat-exchanger surfaces.Reciprocating compressors usually are arranged to start unloaded so that normal torque motors are adequate for starting. When gas engines are used for reciprocating compressor drives, careful matching of the torque requirements of the compressor and engine must be considered.

31、浙 江 海 洋 学 院 毕 业 设 计FIGURE 4.2.5 Illustration of a twin-screw compressor design (courtesy of CarrierCorporation).Screw CompressorsScrew compressors, first introduced in 1958 (Thevenot, 1979), are positive displacement compressors. They are available in the capacity ranges that overlap with reciprocat

32、ing compressors and small centrifugal compressors. Both twin-screw and single-screwcompressors are used in chillers. The twin-screw compressor is also called the helical rotary compressor. Figure 4.2.5 shows a cutaway of a twin-screw compressor design. There are two main rotors (screws). One is desi

33、gnated male (4 in the figure) and the other female (6 in the figure).The compression process is accomplished by reducing the volume of the refrigerant with the rotary motion of screws. At the low pressure side of the compressor, a void is createdwhen the rotors begin to unmesh. Low pressure gas is d

34、rawn into the void between the rotors. As the rotors continue to turn, the gas is progressively compressed as it moves toward the discharge port. Once reaching a predetermined volume ratio, the discharge port is uncovered and the gas is discharged into the high pressure side of the system. At a rota

35、tion speed of 3600 rpm, a screw compressor has over 14,000 discharges per minute (ASHRAE, 1996).Fixed suction and discharge ports are used with screw compressors instead of valves, as used in reciprocating compressors. These set the built-in volume ratio the ratio of thevolume of fluid space in the

36、meshing rotors at the beginning of the compression process to the volume in the rotors as the discharge port is first exposed. Associated with the built-in volume ratio is a pressure ratio that depends on the properties of the refrigerant being compressed. Screw compressors have the capability to op

37、erate at pressure ratios of above 20:1 (ASHRAE, 1996). Peak efficiency is obtained if the discharge pressure imposed by the system matches浙 江 海 洋 学 院 毕 业 设 计the pressure developed by the rotors when the discharge port is exposed. If the interlobe pressure in the screws is greater or less than discha

38、rge pressure, energy losses occur but no harm is done to the compressor.Capacity modulation is accomplished by slide valves that provide a variable suctionbypass or delayed suction port closing, reducing the volume of refrigerant compressed. Continuously variable capacity control is most common, but

39、 stepped capacity control is offered in some manufacturers machines. Variable discharge porting is available on some machines to allow control of the built-in volume ratio during operation.Oil is used in screw compressors to seal the extensive clearance spaces between therotors, to cool the machines

40、, to provide lubrication, and to serve as hydraulic fluid for the capacity controls. An oil separator is required for the compressor discharge flow to remove the oil from the high-pressure refrigerant so that performance of system heat exchangers will not be penalized and the oil can be returned for

41、 reinjection in the compressor.Screw compressors can be direct driven at two-pole motor speeds (50 or 60 Hz). Their rotary motion makes these machines smooth running and quiet. Reliability is high when the machines are applied properly. Screw compressors are compact so they can be changed out readil

42、y for replacement or maintenance. The efficiency of the best screw compressors matches or exceeds that of the best reciprocating compressors at full load. High isentropic andvolumetric efficiencies can be achieved with screw compressors because there are no suction or discharge valves and small clea

43、rance volumes. Screw compressors for buildingapplications generally use either R-134a or R-22.译 文冷水机组1995年,在美国,冷水机组应用在至少4的商用建筑中。而且,由于制冷机组通常安装在较大的建筑中,在同一年里,制冷机组冷却了多于28的商用建筑的地板空间(DOE,1998)。在商用建筑中普遍采用五种型式的制冷机:往复式、螺杆式、旋涡式、离心式和吸收式。前四种利用蒸汽压缩式循环来制得冷冻水。它们的不同主要在于使用的压缩机种类的不同。吸收式制冷机在吸收循环中利用热能(典型的是来自蒸汽或燃料燃烧)并利用

44、氨水或水锂溴化物制得冷冻水。总的系统浙 江 海 洋 学 院 毕 业 设 计图4.2.2 两台制冷机同时作用的系统图及辅助设备(格力有限公司)图4.2.2给出了包括主要辅助设备在内的复式制冷机的简图。大约86的制冷机和表所示的一样用在多台制冷机系统中(Bitondo和Tozzi,1999)。在冷冻水系统中,建筑物的回水通过每个蒸发器循环流动,在蒸发器中,回水被冷却到合意的温度(典型的为47)(3945)。然后,冷冻水通过各设备传送到水空气换热器。在换热器中,空气被冷冻水冷却和加湿。在这个过程中,冷水的温度升高,然后必须回送到蒸发器中。图4.2.2所示的制冷机组是冷水机组。水通过每个机组的冷凝器循

45、环,在冷凝器中,水吸收了来自高压制冷剂的热量。接着,水用水泵打到冷却塔中,水通过蒸发而降温。冷却塔将在后一部分讲述。冷凝器也可以是空冷式的。在这种循环中,冷凝器应是制冷剂空气热交换器,空气吸收来自高压制冷剂的热量。制冷机组名义制冷量为3018000kw(85100tons)。在美国,出售的大部分制冷机组是用电的,利用蒸汽压缩制冷循环来制得冷冻水。在设计中,这种系统所使用的压缩机也有往复式、螺杆式、旋涡式和离心式。一小部分的离心式制冷机利用内燃机或蒸汽机代替电来启动压缩机。在建筑中所使用的制冷机组类型根据应用场所来确定。对于大的办公室建筑或制冷机组需服务于多个建筑时,通常使用离心式压缩机。在所需

46、制冷量小于1000kw(280tons)时,使用往复式或螺杆式制冷机组较合适。在小的应用场合,若低于100kw(30tons)时,使用往复式或旋涡式制冷机组。蒸汽压缩式制冷机浙 江 海 洋 学 院 毕 业 设 计图4.2.3 制冷机在各种不同满负荷百分数时的效率表4.2.5表示了四种电启动的蒸汽压缩式制冷机组的名义制冷量范围。每种制冷机以所使用的压缩机类型来命名。各种系统的制冷能力范围从最小的旋涡式(30kw,8tons)到最大的离心式(18000kw,5000tons)。制冷机可使用HCFCs(R22,R123)或HFCs(R134a)制冷剂。制冷机的效率通常用输入功(用kw表示)与制冷量(

47、用tons表示)的比值表示。1tons的制冷量等于3.52kw或1200btuh。用这种方法衡量效率,其数值越小越好。从表4.2.5可以看出,离心式制冷机的效率最高。而往复式是这四种类型中效率最低的。表中所提供的效率是根据ASHRAE Standard30(ASHRAE,1995)在稳定状态下测得满负荷时的效率,这些效率中不包括辅助设备的能耗,比如泵,冷却塔的风机,而这些设备可以增加0.060.31kw/ton(Smit et al.,1996)。制冷机组在大部分时候是在部分负荷下运行的。只有在建筑物的最高热负荷时,制冷机才在额定制冷量附近运行。知道制冷机在部分负荷下效率是怎样变化的,这是很重

48、要的。图4.2.3给出了往复式、螺杆式、旋涡式、带叶片控制的离心式制冷机组、压缩机频繁启动的制冷机组在满负荷时的百分比下相应的效率(用kw/ton表示)。往浙 江 海 洋 学 院 毕 业 设 计复式制冷机在占满负荷较小的百分比运行时,效率增加。相反地,带叶片控制的离心式的效率在负荷为额定负荷的60以后是基本不变的,它的kw/ton值随百分数的减小而增加到满负荷时的两倍.1998年,空调制冷学会提出了一项新的标准,用来划归在部分负荷下制冷机组的运行情况。部分负荷时的效率用综合部分负荷值(IPLV)这个简单的数值来表示。IPLV在数值上和图4.2.3相似。用25%,50%,75%,100%负荷时的

49、效率来计算这个简单的综合效率。在这些负荷下的度量值分别为0.12,0.45,0.42,0.01。IPLV的计算公式为 IPLV=1/(0.01/A+0.42/B+0.45/C+0.12/D)其中A100%负荷时的效率B75%负荷时的效率C50%负荷时的效率D25 %负荷时的效率大多数的IPLV由满负荷的50%,75%时的效率决定的,根据要求,制造商除了提供如图4.2.3所示部分负荷时的效率,还会提供IPLV值。以下对使用在蒸汽压缩式制冷机中的四种压缩机做简要的讲述。离心式和螺杆式压缩机主要应用在制冷机组上。往复式和旋涡式压缩机应用在整体式空调和热泵中。往复式压缩机图4.2.4 往复式压缩机容积-压力的关系往复式压缩机是一种有确定排量的压缩机。在活塞的进气冲程时,一定量的气体被吸进气缸。在压缩冲程时,气体被压缩直到排气阀打开。在每个冲程被压缩的气体数量等于气缸的体积。在制冷机中使用的压缩机根据压缩机制冷能力不同有不同个气缸的。往复式压缩机使用的制冷剂具有较小体积和相对较高的压

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论