1、nfpa 1961-2007 standard on fire hose-2007 editionnfpa 1961 standard on fire hose 2007 edition nfpa, 1 batterymarch park, quincy, ma 02169-7471 an international codes and standards organization copyright national fire protection association provided by ihs under license with nfpa licensee=purdue univ

2、ersity/5923082001 not for resale, 03/20/2007 03:44:54 mdtno reproduction or networking permitted without license from ihs-,-,-the standard is downloaded from .bzfxw4>#ff66ff'> standard sharingimportant notices and disclaimers concerning nfpa documentsnotice and disclaimer of liability conc

3、erning the use of nfpa documentsnfpa codes, standards, recommended practices, and guides, of which the document contained herein is one, are de-veloped through 9><#990099'>a consensus standards development process approved by the american national standards institute.this process brings

4、 together volunteers representing varied viewpoints and interests to achieve consensus on fire andother safety issues. while the nfpa administers the process and establishes rules to promote fairness in the develop-ment of consensus, it does not independently test, evaluate, or verify the accuracy o

5、f any information or the soundnessof any judgments contained in its codes and standards.the nfpa disclaims liability for any personal injury, property or other damages of any nature whatsoever, whetherspecial, indirect, consequential or compensatory, directly or indirectly resulting from the publica

6、tion, use of, or relianceon this document. the nfpa also makes no guaranty or warranty as to the accuracy or completeness of any informationpublished herein.in issuing and making this document available, the nfpa is not undertaking to render professional or other servicesfor or on behalf of any pers

7、on or entity. nor is the nfpa undertaking to perform any duty owed by any person or entityto someone else. anyone using this document should rely on his or her own independent judgment or, as appropriate,seek the advice of <#990099'>a competent professional in determining the exercise of r

8、easonable care in any given circumstances.the nfpa has no power, nor does it undertake, to police or enforce compliance with the contents of this document.nor does the nfpa list, certify, test or inspect products, designs, or installations for compliance with this document.any certification or other

9、 statement of compliance with the requirements of this document shall not be attributable tothe nfpa and is solely the responsibility of the certifier or maker of the statement.copyright national fire protection association provided by ihs under license with nfpa licensee=purdue university/592308200

10、1 not for resale, 03/20/2007 03:44:54 mdtno reproduction or networking permitted without license from ihs-,-,-the standard is downloaded from .bzfxw#ff66ff'> standard sharingadditional notices and disclaimersupdating of nfpa documentsusers of nfpa codes, standards, recommended practices, and

11、guides should be aware thatthese documents may be superseded at any time by the issuance of new editions or may beamended from time to time through the issuance of tentative interim amendments. an offi-cial nfpa document at any point in time consists of the current edition of the documenttogether wi

12、th any tentative interim amendments and any errata then in effect. in order todetermine whether <#990099'>a given document is the current edition and whether it has been amendedthrough the issuance of tentative interim amendments or corrected through the issuance oferrata, consult appropri

13、ate nfpa publications such as the national fire codes? subscriptionservice, visit the nfpa website at ., or contact the nfpa at the address listedbelow.interpretations of nfpa documents<#990099'>a statement, written or oral, that is not processed in accordance with section 6 of the

14、 reg-ulations governing committee projects shall not be considered the official position of nfpaor any of its committees and shall not be considered to be, nor be relied upon as, <#990099'>a formalinterpretation.patentsthe nfpa does not take any position with respect to the validity of any

15、 patent rightsasserted in connection with any items which are mentioned in or are the subject of nfpacodes, standards, recommended practices, and guides, and the nfpa disclaims liability forthe infringement of any patent resulting from the use of or reliance on these documents.users of these documen

16、ts are expressly advised that determination of the validity of any suchpatent rights, and the risk of infringement of such rights, is entirely their own responsibility.nfpa adheres to applicable policies of the american national standards institute withrespect to patents. for further information con

17、tact the nfpa at the address listed below.law and regulationsusers of these documents should consult applicable federal, state, and local laws and reg-ulations. nfpa does not, by the publication of its codes, standards, recommended practices,and guides, intend to urge action that is not in complianc

18、e with applicable laws, and thesedocuments may not be construed as doing so.copyrightsthis document is copyrighted by the nfpa. it is made available for <#990099'>a wide variety of bothpublic and private uses. these include both use, by reference, in laws and regulations, anduse in private

19、 self-regulation, standardization, and the promotion of safe practices andmethods. by making this document available for use and adoption by public authorities andprivate users, the nfpa does not waive any rights in copyright to this document.use of nfpa documents for regulatory purposes should be a

20、ccomplished through adop-tion by reference. the term “adoption by reference” means the citing of title, edition, andpublishing information only. any deletions, additions, and changes desired by the adoptingauthority should be noted separately in the adopting instrument. in order to assist nfpa infol

21、lowing the uses made of its documents, adopting authorities are requested to notify thenfpa (attention: secretary, standards council) in writing of such use. for technical assis-tance and questions concerning adoption of nfpa documents, contact nfpa at the addressbelow.for further informationall que

22、stions or other communications relating to nfpa codes, standards, recommendedpractices, and guides and all requests for information on nfpa procedures governing itscodes and standards development process, including information on the procedures forrequesting formal interpretations, for proposing ten

23、tative interim amendments, and forproposing revisions to nfpa documents during regular revision cycles, should be sent tonfpa headquarters, addressed to the attention of the secretary, standards council, nfpa,1 batterymarch park, p.o. box 9101, quincy, ma 02269-9101.for more information about nfpa,

24、visit the nfpa website at ..copyright national fire protection association provided by ihs under license with nfpa licensee=purdue university/5923082001 not for resale, 03/20/2007 03:44:54 mdtno reproduction or networking permitted without license from ihs-,-,-the standard is downloaded from

25、 .bzfxw#ff66ff'> standard sharingcopyright ? 2007 national fire protection association. all rights reserved.od2ssstios4t1m1cpeswrhbmssmfo19611copyright national fire protection association provided by ihs under license with nfpano reproduction or networking permitted without licensenfpa 1961s

26、tandard onfire hose2007 editionthis edition of nfpa1961, standard on fire hose, was prepared by the technical committeen fire hose. it was issued by the standards council on december 1, 2006, with an effectiveate of december 20, 2006, and supersedes all previous editions.this edition of nfpa1961 was

27、 approved as anamerican national standard on december 20,006.origin and development of nfpa 1961standards on fire hose for both industrial use and fire department use were among the earliesttandards issued by nfpa, with the first standard issued in 1898. nfpa 196 was issued in 1934 astandard specifi

28、cation for cotton rubber-lined fire hose for public and private fire department use. thattandard remained in existence until 1958, when the fire hose committee was again constitutedo update the requirements. <#990099'>a tentative standard was issued in 1958 and the official standard wasssu

29、ed in 1960 recognizing the newer syntheticmaterials that were being used in themanufacturef fire hose. the 1960 standard covered fire hose in the 1 in., 11?2 in., 2 in., and 21?2 in. sizes foringle or multiple jacket hose and 3 in. and 31?2 in. sizes for multiple jacket hose.in the 1972 edition, the

30、 concept of single jacket relay supply hose in the trade sizes of 3 in.,in., 41?2 in., 5 in., and 6 in. was introduced. in 1979 the standard was renumbered fromnfpa196o nfpa 1961 to coincide with <#990099'>a general renumbering of the fire service standards. in the992 edition, the term “ra

31、ck and reel hose” was changed to “occupant use hose,” the require-ents for forestry hose were updated, and the requirements for suction hose were added. the997 edition was <#990099'>a reconfirmation of the 1992 edition.the 2002 edition was completely revised to conform to the manual of sty

32、le for nfpa techni-al committee documents, to clean up ambiguous language, and to clarify the requirements.rocurement-related issues were deleted from the requirements of the document, and anquivalency statement and <#990099'>a formal retroactivity statement were added. the minimum tradeiz

33、e requirement was dropped for all but supply hose. the requirements for specific lengthsere changed to only require <#990099'>a tolerance on the stated nominal length. positive pressureequirements for hard suction hose were deleted.<#990099'>a cold resistance test was added for a

34、ll hose. specific requirements were added to test theose for abrasion resistance, heat resistance, water resistance, degradation from repeatedending, and degradation from alternating pressures. the flexibility and compressibility testethod for forestry hose previously referenced to usda forest servi

35、ce specifications wastated in the standard. the chapter on inspection and tests was reorganized around fourubject areas: quality control, inspection, testing, and certification.the 2007 edition is <#990099'>a general update of the 2002 edition, and clarifies ambiguous require-ents. the sec

36、tion for testing elongation, twist, warp, and rise has been revised to clarify theour distinct tests. this edition also requires all new fire hose to be marked with the country ofrigin so that purchasers are informed where the product is manufactured.licensee=purdue university/5923082001 not for res

37、ale, 03/20/2007 03:44:54 mdt from ihs-,-,-the standard is downloaded from .bzfxw#ff66ff'> standard sharingtechnical committee on fire hoseray k. farm,thomas g. finc., il imrep. natiorobert m. hdavid v. haspaul r. kaverep. edislawrence b.gregory kozeduane leonhrep. firelarry linton,department,

38、nt, ca u), inc.,eartment,inc.,paul e. albincompany, in(alt. to dgeorge e. lail rt(alt. to r.ulaurence j. stcn<#990099'>acfn19612 fire hose20copyright national fire proteprovided by ihs under licensno reproduction or networkin-,-,-07 editionction association e with nfpa licensee=not for reg

39、 permitted without license from ihsstephen gilbert, chairlos angeles, ca secity of corvallis fire department, or uarruggia, illinois fire extinguisher company,nal association of fire equipment distributorsarcourt, snap-tite hose, inc., pa mton, u.s. department of agriculture, ca rtler, ameren servic

40、es, mo uon electric instituteking, fm global/fm approvals iy, kochek company, inc., ct mardt, mercedes textiles ltd., canada mequipment manufacturers associationwashington township volunteer firein lterry powers, san diego fire/rescue departmedavid j. pritchard, pritchard &amp; associates (ncnc

41、sejohn w. stacey, bellevue fire department, nerep. international association of fire chiefsjoe stonecypher, kidde fire fighting, tx mtim j. vanderlip, los angeles county fire depca urichard c. winton, underwriters laboratoriesil rtrep. underwriters laboratories inc.alternatesger, jr., elkhart brass

42、manufacturingc., in m. leonhardt)verick, underwriters laboratories inc.,c. winton)byron j. sarago, detroit edison company, mi(alt. to p. r. kaveler)tewart, nfpa staff liaisonhis list represents the membership at the time the committee was balloted on the final text of this edition. since that time,h

43、anges in the membership may have occurred. <#990099'>a key to classifications is found at the back of the document.ote:membership on <#990099'>a committee shall not in and of itself constitute an endorsement of theassociation orny document developed by the committee on which the

44、member serves.ommittee scope:this committee shall have primary responsibility for documents on the size and design ofire hose connections, and the performance, maintenance, and selection of all types of fire hose, couplings,ozzles, and accessory equipment.purdue university/5923082001 sale, 03/20/200

45、7 03:44:54 mdtthe standard is downloaded from .bzfxw#ff66ff'> standard sharingcontentschapter 1 administration . 1961 41.1 scope . 1961 41.2 purpose . 1961 41.3 application . 1961 41.4 retroactivity . 1961 41.5 equivalency . 1961 41.6 units . 1961 4chapter 2 referenced publications . 1961 42.

46、1 general . 1961 42.2 nfpa publications . 1961 42.3 other publications . 1961 42.4 references for extracts in mandatorysections. (reserved) . 1961 4chapter 3 definitions . 1961 43.1 general . 1961 43.2 nfpaofficial definitions . 1961 43.3 general definitions . 1961 5chapter 4 design requirements . 1

47、961 54.1 requirements for attack hose . 1961 54.2 requirements for supply hose . 1961 6c5.3 reinforcement . 1961 75.4 linings and covers . 1961 75.5 hose characteristics . 1961 85.6 marking . 1961 8chapter 6 test methods for manufacturershose certification . 1961 96.1 general . 1961 96.2 proof test

48、. 1961 96.3 elongation, twist, warp, and rise tests. . 1961 96.4 kink test . 1961106.5 burst test . 1961106.6 adhesion test . 1961106.7 tensile strength and elongation . 1961106.8 oven aging test . 1961116.9 ozone resistance . 1961116.10 cold bending test . 1961116.11 cold flexibility test . 1961116

49、.12 oil immersion test . 1961116.13 flexibility and compressibility testing . 196111chapter 7 sampling, inspection, and tests . 1961127.1 quality control . 196112<#990099'>a<#990099'>ai19613contentscopyright national fireprovided by ihs underno reproduction or netw4.3 requirement

50、s for occupant use hose . 1961 64.4 requirements for forestry hose . 1961 64.5 requirements for suction hose . 1961 6hapter 5 construction requirements . 1961 75.1 diameter . 1961 75.2 length . 1961 7 protection association license with nfpa licenseenot for rorking permitted without license from ihs-,-,-7.2 inspection . 1961127.3 testing . 196112nnex <#990099'>a explanatory material . 196112nnex b informational references . 196114ndex . 1961152007 edition=purdue unive

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论