1、摘 要水是人类社会赖以生存和发展的物质基础,是不可或缺、难以代替的重要资源。随着生活水平的提高,使人们对水质、水量的要求越来越高,这就要求给水排水工程专业人员予以城市给水系统合理的规划和设计。福州市高新区属于新建城区,尚无给水管网和给水厂。给水系统是城市和工况企业的一项重要的基础设施,它主要由取水工程、净水工程、输水管渠、城市管网、泵站以及其他调节构筑物构成。因梅花江水源不宜处理,故采用香榭湖作为水源。采用如下净水工艺流程:管式混合机械反应平流沉淀臭氧接触氧化池活性炭滤池过滤液氯消毒。本设计说明书主要内容包括:设计原始资料;取水、净水、输水工程主要构筑物工艺设计计算;泥处理构筑物计算以及附录等
2、。关键词:关键词:给水工程设计,福州市高新区,净水工艺,管网,泵站设计abstractwater is basical and indispensable resources of human societys survival and development .it is really important ,never replaced. with the improving of the peoples living standards,the demand to quality and quantity of water become higher and higher. this re
3、quires that water supply and drainage engineering professionals to be reasonable urban water supply system planning and design.urban water supply system and the status of an important enterprise infrastructure, which works mainly by water, water purification projects, drainage pipes, urban pipelines
4、, pumping stationns and other structures constitute regulation.high-tech zone in fuzhou city is a new zone, there is no water supply network and water treatment plant. plum river water should not be raw water, so champs-lake water is used. the water purification process used is as follows : mixer tu
5、be mechanical flocculation torizontal sedimentation tankozone contact oxidation pondactivated carbon filterchlorine disinfectionthe design of brochures main contents include :design original information; water, water purification and water main structures of the project design; t the sludge treatmen
6、t design and appendix.key words: water-supply engineering design,fuzhou high-tech zone, water purification process, pipe network, pumping station design目录1 绪论.11.1 设计资料概述.11.1.1 原始资料.12 方案的选择和管网计算.42.1 供水方案的确定.42.1.1 设计后的工程要求.42.2 城市管网设计计算.42.2.1 城市最高日用水量计算.42.2.2 城市最高日最大时用水量计算.52.2.3 用水量变化系数.62.3 清
7、水池设计计算.62.3.1 清水池容积计算.62.3.2 管道布置.72.4 管网定线.82.4.1 布置原则.82.4.2 配水管定线.92.5 统一供水水力计算.92.5.1 比流量计算.92.5.2 沿线流量计算.92.5.3 节点流量计算.102.5.4 流量分配.112.5.5 最不利点的选择.122.5.6 管网平差.122.5.7 消防校核.122.5.8 事故校核.122.6 二泵站扬程的确定以及水泵的选择.122.6.1 二级泵站扬程的确定.122.6.2 选择二泵站水泵.133 取水工程设计.143.1 集水井设计.143.1.1 进水室设计.143.1.2 集水室设计.1
8、43.1.3 集水井.153.2 一泵站设计.153.2.1 设计流量和扬程的确定.153.2.2 选择水泵.163.2.3 基础尺寸.163.2.4 吸水管路和压水管路的计算.163.2.5 水泵安装高度的确定与泵房高度计算.163.3 辅助设备的确定.164 净水厂设计.184.1 设计水量确定.184.2 工艺流程的确定.184.3 混合反应.184.3.1 混凝剂的选择和投加.184.3.2 投药系统计算.184.3.3 加药间及药库.194.3.4 混合工艺设计计算.194.3.5 絮凝工艺设计计算.194.4 沉淀.214.4.1 池体设计计算.214.4.2 进出水部分设计.22
9、4.4.3 放空管.234.4.4 排泥设备.234.5 臭氧处理.234.5.1 池体体积尺寸.234.5.2 气源制备.234.5.3 臭氧布气系统计算.244.6 活性炭过滤.244.6.1 滤池尺寸计算.254.6.2 配水系统计算.264.6.3 洗砂排水槽.304.6.4 滤池反冲洗计算.314.6.5 进出水系统.324.7 消毒.334.7.1 加氯量的确定.334.7.2 加氯机及漏氯处理.334.7.3 加氯间及氯库设计计算.334.8 送水泵站设计.344.8.1 基础设计.344.8.2 吸水管路和压水管路的计算.344.8.3 泵房平面布置.344.8.4 各工艺标高
10、的确定.344.8.5 泵房高度设计.344.8.6 附属设备.354.8.7 吸水井设计.364.9 排泥水处理.374.9.1 浓缩池计算:.374.9.2 调节池计算:.384.9.3 污泥脱水机房.384.10 辅助建筑物.394.11 水厂平面布置.394.12 高程布置.395 投资估算.415.1 工程概况.415.1.1 直接费.415.1.2 年经营管理费用.415.2 制水成本.435.3 估算依据.43设计总结.45致谢.46参考文献.47附录.49附表一.49附表二.53附表三.571 绪论1.1 设计资料概述1.1.1 原始资料(1)城市路网图一张,比例 1:1000
11、0(2)用水资料拟建之工业园区位于福建中部,梅花江岸边,香榭湖畔。园区规划人口数23 万人,给水普及率按 96%考虑;房屋平均层数 67 层,室内均有卫生设备但无淋浴设备。城市综合生活用水每小时用水量占最高日用水百分比情况见下表1.1。表表 1.1 福州市高新区每小时用水量占最高日用水量百分比情况表福州市高新区每小时用水量占最高日用水量百分比情况表时间小时用水量占最高日用水量(%)时间小时用水量占最高日用水量(%)时间小时用水量占最高日用水量(%)012.82895.1116175.11122.799104.8117184.92232.9310114.7418194.90343.0611124
12、.5219204.71453.1312134.4920214.38563.7813144.4521224.04674.9314154.4522233.42785.1315164.5523243.02高新区共有工业企业 4 家,位置见城市总体规划布置图。各企业供水水质要求同生活用水,用水量情况如下:(a)化工厂,生产用水量 12000m3/d。工人总数 6000 人,分 3 班工作,热车间占 20%。 第一班 2000 人,使用淋浴者 400 人,其中热车间 400 人; 第二班 2000 人,使用淋浴者 400 人,其中热车间 400 人; 第三班 2000 人,使用淋浴者 400 人,其中热
13、车间 400 人。(b)海鲜加工厂,生产用水量 8000m3/d。 工人总数 6000 人,分 3 班工作,热车间占 20%。第一班 2000 人,使用淋浴者 400 人,其中热车间 400 人;第二班 2000 人,使用淋浴者 400 人,其中热车间 400 人; 第三班 2000 人,使用淋浴者 400 人,其中热车间 400 人。(c)纺织厂,生产用水量 10000m3/d。 工人总数 3000 人,平均分 3 班工作,无热车间。(d)造纸厂,生产用水量 10000m3/d。 工人总数 4800 人,平均分 3 班工作,无热车间。(4)地形地貌地形较平坦,平均海拔高度在 25m35m 之
14、间。(5)工程地质及水文地质工程地质良好,适宜于工程建设,地质构造一般皆为四层:表土或耕土厚 0.5m 左右;粘土及砂质粘土,即第四纪土层,厚 8m 左右,耐压力 2kg/cm2以上;砂砾岩,即白沙井层,厚 30m 以上,耐压力 25kg/cm2;基岩,即第三纪红色砂岩,个别地区夹石膏岩。(6)气象气温见表 1.2。表表 1.2 福州市气温资料福州市气温资料项 目温度()发生时间最热42.17 月月平均最冷3.61 月平均20.5降雨量见表 1.3。表表 1.3 福州市降雨量资料福州市降雨量资料序号项 目降雨量(mm)备 注1平均年总量1170.02一日最大186.63一小时最大96.6风向见
15、表 1.4。表表 1.4 福州市风向频率情况福州市风向频率情况年最多风向及其频率(%)c31 se14冬季平均1.6风速(m/s)夏季平均1.7无自发性震源,强度在 4 级以下。(7)河流水文及水质资料由于地下水和梅花江受工业污染较重,不能满足供水水质要求,故考虑以香榭湖为供水水源地。水源地地处顺直湖岸,岸边边坡较陡,基岩露头,河床与河岸稳定。工程地质良好。水中漂浮物较少。水源地取水口处水位及流量见表 1.5。香榭湖富营养化现象严重,藻类数量可达 1003000 万个/l。常规水质资料如表 1.6 所示。水温:多年统计,月平均 2.427.2。表表 1.5 福州市水源地区取水口水文资料福州市水
16、源地区取水口水文资料项目水位黄海标高(m)频率(%)最高水位231最低水位1595常水位18表表 1.6 水源水水质资料水源水水质资料编号项目单位分析结果附注1色度度202浊度ntu2003ph 值6.9-7.54嗅和味度无5总硬度mg/400以 caco3计6铜mg/0.0077锌mg/0.2218锰mg/210-59砷mg/2.610-410细菌总数个/10011大肠菌群个/600 2 方案的选择和管网计算2.1 供水方案的确定2.1.1 设计后的工程要求水质要求生活饮用水水质须满足生活饮用水卫生标准中的各项指标,并在管网末梢保持一定的余氯。水量要求净水厂按最高日平均时设计,城市管网和输水
17、管及二泵站按最高日最高时设计,事故时要求供水量不低于最高日最高时的 70。水压要求房屋层数 6-7 层,要求最小水压 280kpa, ;消防时采用低压消防制,要求100kpa 自由水压。2.2 城市管网设计计算2.2.1 城市最高日用水量计算城市用水量(1)居民生活用水量 q1 q1qnf (m3/d) (2.1)式中,q最高日综合生活用水量定额,l/(人d); n设计年限内计划人口数, f自来水普及率,。q220l/(per.d);f=96%q1qnf22010-32310496%=4.8576104(m3/d)工业企业内工作人员的生活用水量及淋浴用水量 q2工厂内工作人员生活用水量为 q2
18、,淋浴用水量为 q2a 化工厂:全厂生活用水量:q2=2000380%0.025+600020%0.035=120 +42=162(m3/d)淋浴用水量:q2=40036010-3=72(m3/d)b 海鲜加工厂:全厂生活用水量:q21=2000380%0.025+600020%0.035=120 +42=162(m3/d)淋浴用水量:q21=40036010-3=72(m3/d)c 纺织厂:全厂生活用水量:q2=30002510-3=75m3/d);d 造纸厂:q2=48002510-3=120(m3/d)(2)工业企业内工作人员的生活用水量及淋浴用水量q2=162+162+722+75+1
19、20=663(m3/d)(3)工业企业生产用水量 q3q312000+8000+10000+10000=40000 (m3/d)(4)浇洒道路与绿地用水量 q4q4=3%(q1+q2+q3)= 3%(48576+663+40000)=0.0389239=2677.17(m3/d)(5)未预见用水量及管网漏失水量 q5一般可以按最高日用水量的 1525计算,此设计中采用 20。 q520(q1+ q2+ q3+ q4+)20(48576+663+40000+2677.17)=18383.234(m3/d) 城市最高日用水量 qd q1 +q2 +q3 +q4 +q5 + q6 48576+663
20、+40000+2677.17+18383.234 110299.404(m3/d)取 110300(m3/d)2.2.2 城市最高日最大时用水量计算居民生活用水量按原始资料中给定的逐时变化系数确定每一时段的用水量;工厂生活用水量按一定的系数进行分配,淋浴用水集中发生在每班下班的一个小时内;浇洒道路与绿地用水按 24h 均匀分配;未预见用水量按 24h 均匀分配。统一供水最高日用水量变化表见表.从表中可以求出:qhmax=5094.2 (m3/h);占全天用水量的 4.62。供水最高日用水量见表 2.1表表 2.1 统一供水最高日用水量变化表统一供水最高日用水量变化表时间生活用水量(l/s)工业
21、用水(l/s)绿地用水(l/s)未预见水量(l/s)淋浴用水量(l/s)每小时用水量(l/s)占最高日用水量的百分比0-113681688.3111.57663933.83.57 1-21353.51688.3111.57663919.33.55 2-31421.51688.3111.57663987.33.61 3-41484.61688.3111.5766 4050.43.67 4-51518.61688.3111.57664084.43.70 5-61834.41688.3111.57664400.23.99 6-723931688.3111.57664958.84.50 7-82490
22、.11688.3111.57665055.94.58 8-92480.41688.3111.5766485094.24.62 9-102334.71688.3111.57664900.54.44 10-112300.71688.3111.57664866.54.41 11-122193.81688.3111.57664759.64.32 续表续表 2.1时间生活用水量(l/s)工业用水(l/s)绿地用水(l/s)未预见水量(l/s)淋浴用水量(l/s)每小时用水量(l/s)占最高日用水量的百分比12-132135.51688.3111.57664701.34.2613-142159.81688
23、.3111.57664725.64.28 14-152159.81688.3111.57664725.64.28 15-162208.41688.3111.576647754.33 16-172475.61688.3111.5766485089.44.61 17-182388.11688.3111.57664953.94.49 18-192378.41688.3111.57664944.24.48 19-202286.21688.3111.576648524.40 20-212125.81688.3111.57664691.64.25 21-221960.71688.3111.57664526
24、.54.10 22-231659.21688.3111.576642253.83 23-241465.21688.3111.57664840793.70 2.2.3 用水量变化系数 采用统一供水方案 从用水量计算得知,最高时用水量在 8-9 时,占全天用水量的 4.62%,而平均时用水量占全天用水量的 4.17%,因此,时变化系数为;kh=4.62/4.17=1.11在城市用水中,居民生活用水及工业用水在每一时刻并不完全相同,而一泵站在取水及输水过程中却是完全均等的,这便存在着水量并不完全协调一致的问题,因此采用清水池来调节这种水量的不平衡。2.3 清水池设计计算2.3.1 清水池容积计算w=
25、w1+w2+w3+w4 (2.2)其中,w1调节容量(m3);见表 2.2。w2水厂冲洗滤池和沉淀池排泥等生产用水,m3,等于最高日用水量的 5%-10%;w3消防储量,按火灾延续两小时计算,m3,按同时发生两次火灾,一次灭火用水量取 55l/s;w4安全容量取 755 m3w1=1048420.29%=304.04m3w2=1048428%=8387.36 m3w3=5510-3223600=792 m3所以,w= w1+w2+w3+w4=304.04+8387.36+792+755=10238.4 m3清水池采用钢筋混凝土矩形水池设 2 个清水池。每个清水池的容积为:6000(m3) ;
26、每座清水池设计尺寸为 blh=18m100m3.3m ,有效容积为 18m100m3.0m,超高 0.3m。 表表 2.2 清水池调节容积清水池调节容积时间用水量(%)一级泵站供水量(%)清水池调节容积(无水塔)(%)013.64.17-0.57123.544.17-0.63233.644.16-0.52343.694.17-0.48453.724.17-0.455644.16-0.16674.784.170.61784.574.170.4894.64.160.449104.434.170.2610114.44.170.2311124.314.160.1512134.34.170.131314
27、4.284.170.1114154.284.160.1215164.324.170.1516174.64.170.4317184.484.160.3218194.474.170.319204.394.170.2220214.254.160.0921224.114.17-0.0622233.854.17-0.3223243.684.16-0.48累计1001000.292.3.2 管道布置(1)进水管 进、出水管一般分开设置在不同的部位,促进水流循环。进水管标高因考虑避免由于池中水位变化而形成进水管的气阻,可采用降低进水管标高,或进水管进池后用弯管下弯,本设计采用后者。 进水管管径由最高日平均时
28、确定,管内流速在 0.71.0m/s 之间。slhmq/694/2500224120003max进水管管径取 1000mm,材质为铸铁管。 ,符合要求。smdq/88. 042max(2)出水管因为二泵房设有吸水井,清水池的出水管(至二级泵房的吸水井)设置一根。出水管的设置形式采用水泵吸水管直接弯入池底吸水坑吸水。出水管管径按最高日最大时用水量计算,管内流速:0.61.0m/sqmax1415/2=707.5l/s,管径取 1200mm,材质为铸铁管。,符合要求。smdq/63. 042max(3)溢流管为保证清水池安全运行,设置溢流管,当清水池蓄满,进水流量大于出水流量时,多余的水可由溢流管
29、排出。为确保溢流管畅通,溢流管管径与进水管相同,采用管径 1000mm 的钢管。管端为喇叭口,管上不安装阀门。溢流管出口设置网罩,以防爬虫等沿溢流管进入池内。(4)放空管设置排水管的目的是为了排出清水池中的废水,及检修时将清水池内的水泄空。由于本设计清水池埋深较大,排水困难,因而可以采用潜水泵,在需要时装设,直接用水泵中抽出。为了便于排空池水,池中设置一定的坡度,i5。取 2 小时放空,那么, (v=1.0m/s)md06. 10 . 114. 33600246000取 dn1100(5)通风口为使进水量、出水量交替,并适应水位高低变化,在每座清水池设置d300mm 的通风管 12 根,间距为
30、 10m。6.检修孔每座清水池设两个人孔及扶梯,以便于维护管理,检修孔直径采用1400mm。7.池顶覆土厚度 池顶覆土厚度应满足地下水抗浮要求,并符合保温需要,本设计中采用800mm 的覆土厚度。8.导流墙目的是为了避免池内水短流,和满足加氯后的接触要求。根据加氯后接触30min 的要求,每座清水池中设置 3 道导流墙,导流墙间距 5m。2.4 管网定线2.4.1 布置原则城镇管网定线应满足以下几点要求:(1)依据规划总平面图,考虑分期建设的可能性,且留有发展余地,便于今后的扩建和改建;(2)保证供水的安全可靠,局部若出现事故,断水范围最小;(3)尽量使干管靠近大用户,便于取水,且降低输水费用
31、;(4)保证用户有足够的水量和水压;(5)力求管线最短。 2.4.2 配水管定线为保证安全供水,方案采用环状管网供水,给水系统方案一共 15 个环。管网计算见管网平差计算表,具体分配方案见下文。2.5 统一供水水力计算2.5.1 比流量计算为便于计算而在实际计算中对管网计算加以简化,假定用水量均匀分布在全部干管上,由此得出来的单位管线长度上的流量叫做比流量,以 qs表示。qs=(q-q)/l (2.3)其实质就是:qs(q生活+q未预见)/l计算管线总长度应按有效长度计算,双侧配水按实际长度计算,单侧配水按照实际长度的 1/2 计算,不配水管线不计算。跟据所定管网,管道有效总长为 37583.
32、73 米,则比流量为: msllqqqhs/0.04112297336 .47014152.5.2 沿线流量计算整个管网沿线流量总和,等于。其中计算见表 2.2。1qlqsqqlqs 表表 2.2 沿线流量计算表沿线流量计算表管段标号管长(m)比流量/(l/s.m)备注有效管长(m)沿线流量(l/s)3-29270.0411单侧463.519.049852-118680.041143417.837410-118780.041143918.04293-108010.0411400.516.460552-15320.0411单侧26610.93261-129360.0411单侧46819.2348
33、11-125320.041153221.865210-159240.041192437.976415-149200.041192037.81211-149580.041195839.373814-135120.041151221.043212-139340.041193438.387415-226640.041166427.290422-239350.0411单侧467.519.2142514-236690.041166927.495923-245080.0411单侧25410.4394续表续表 2.22.2管段标号管长比流量备注有效管长沿线流量(l/s)(m)/(l/s.m)(m)13-24
34、6890.0411单侧344.514.158953-49280.0411单侧46419.07044-97810.041178132.099110-910840.0411108444.55244-59380.0411单侧46919.27595-88650.041186535.55159-88850.041188536.37355-65370.0411单侧268.511.035356-79340.0411单侧46719.19378-75300.041153021.78315-1610920.0411109244.88129-169130.041191337.52438-179340.0411934
35、38.387416-179190.041191937.77097-189460.0411单侧47319.440317-185330.041153321.906322-2111060.0411单侧55322.728316-216520.041165226.797221-2017-209477150.04110.0411单侧473.5357.519.4608514.6932520-195340.0411单侧26710.973718-196850.0411单侧342.514.076752.5.3 节点流量计算管网任一点的节点流量为: (2.4) 115 . 0qqqi即任一节点 流量等于与该节点相连
36、各管段的沿线流量总和的一半,见表iiqiq2.3。表表 2.3 节点流量计算表节点流量计算表节点编号沿线流量(l/s)集中流量(l/s)节点流量(l/s)事故节点流量(l/s)115.083795.301110.384777.26929223.9099323.9099316.7369475327.290427.290419.10328435.222735.222724.65589532.9313832.9313823.0519625615.1145315.1145310.5801675730.208530.208521.14595866.0477141.58207.6277145.33939
37、续表续表 2.32.3节点编号沿线流量集中流量节点流量事故节点流量(l/s)(l/s)(l/s)(l/s)975.2746575.2746552.6922551058.51613117.13175.6461122.95228751148.5596548.5596533.9917551239.743739.743727.820591336.7947836.7947825.75634251462.8624562.8624544.0037151573.9873.9851.7861673.486873.486851.440761756.3789356.3789339.46524751827.71168
38、27.7116819.39817251912.5252312.525238.76765752022.563922.563915.794732134.4931834.493182461648116.61151.2265105.85853252328.5747828.5747820.00234252412.2991812.299188.60942252.5.4 流量分配根据节点流量的大小,按水流沿最短路径到达用户的原则,适当的分配管段流量,各节点流量满足连续性方程q=0。流向节点的流量取负号,反之取正号。流量分配见表 2.4。表表 2.4 流量分配表流量分配表节点号总沿线
39、流量(l/s)流量(l/s)集中流量(l/s)节点流量(l/s)事故节点流量(l/s)130.167415.08495.301110.384777.26929247.8198523.9123.9099316.7369475354.580827.2927.290419.10328470.445435.22335.222724.65589565.8627532.93132.9313823.0519625630.2290515.11515.1145310.5801675760.41730.20930.208521.145958132.095466.048141.58207.6277145.33939
40、9150.549375.27575.2746552.69225510117.0322558.516117.13175.6461122.9522881197.119348.5648.5596533.9917551279.487439.74439.743727.820591373.5895536.79536.7947825.756342514125.724962.86262.8624544.003715续表续表 2.42.4节点号总沿线流量流量集中流量节点流量事故节点流(l/s)(l/s)(l/s)(l/s)量(l/s)15147.9673.9873.9851.78616146.973673.48
41、773.486851.4407617112.7578556.37956.3789339.46524751855.4233527.71227.7116819.39817251925.0504512.52512.525238.76765752045.127822.56422.563915.794732168.9863534.49334.49318242329534.616116.61151.2265105.8585332357.1495528.57528.5747820.00234252424.5983512.29912.299188.60942252.5.5 最不利点的
42、选择由于输水管和管网中存在水头损失,以至离泵站越远的地方自由水压下降越多,而地形越高之处,自由水压也低,所以二泵站的扬程应使离心泵站远和地形高的地点,达到规定的自由水压。只要这个点的水压符合要求,全管网的水压就有了保证。平差前要初步选定节点 19 为供水最不利点2.5.6 管网平差平差结果见附表一。2.5.7 消防校核在整个系统中取 2 处最不利点作为着火点,一处选在最高最远点,即节点19;另一处选在大用户节点处,即节点 10。在原先节点流量的基础上,这 2 个节点各自再加上 65l/s,做消防校核。消防平差结果见附表二。2.5.8 事故校核在事故时,只考虑在一条管道出现事故的情况,能否满足必
43、要的水力条件。那么,我们只要校核在最不利管段出现事故时,管网能否满足水力条件,如果能满足,则说明不管哪条管段发生事故,管网均能够满足水力条件。在事故时,除了集中流量必须满足外,其他流量按最大时的 70%计算。校核最不利点自由水压能否满足其相应的自由水压。事故校核见附表三。2.6 二泵站扬程的确定以及水泵的选择2.6.1 二级泵站扬程的确定(1)确定最不利点:通过对各点水压标高及自由水压的计算,确定最不利点为 19 节点,该点设计自由水头为 28 米,地面标高 31.1 米。(2)水泵扬程计算:最大用水时管网平均水头损失由平差结果得出:h=11.81m水泵扬程按下式计算hp=hc+h+hs+hc
44、+zc+h0 (2.5)式中: hc控制点的设计自由水压 为 28m h管网的水头损失 为 11.81m hs泵站内的水头损失 取 2m hc输水管水头损失 为 0.8m zc控制点地面与清水池最低水位的高程差 清水池最低水位标高为 25.30m,控制点地面标高 31.1m,故zc=31.1-25.30=5.8m h0安全水头 取 2m那么 hp=28+11.81+2+0.8+5.8+2=50.41m 取 51m消防时水泵所需扬程:hp=hf+h+hs+hf+zc+ho (2.6)式中: hf消防时所需自由水头,低压消防 为 10m h通过消防流量时的管网水头损失 为 19.73m hf消防时
45、输水管的水头损失 为 2.2m那么 hp=10+19.73+2+2.2+5.8+2=40.53m可见 hphp,水泵扬程满足消防要求。事故时水泵所需扬程: h”p=hc+h”+hs+hc+zc (2.7)式中: hc消控制点的设计自由水头 为 28m h”事故时通过 70%qd的管网水头损失 为 12.43m hc事故时输水管的水头损失 为 0.8m 那么 h”p=28+14.03+1+0.8+5.8=47.83m 可见 h”p4 长深比:l/h=94/3.2=29.3510弗劳德数: (4.7)rgvfr2式中:水力半径 (4.8)wr 考虑到池内设有导流墙过水断面面积 w=bh=43.2=
46、12.83.6 3.512.6bh湿周4 .102 . 3242hb 则=12.6/10.4=1.21wr 那么满足 110-5110-4521043. 18 . 921. 1013. 0rf雷诺数: 属于紊流状态。1560001. 021. 13 . 1revr4.4.2 进出水部分设计(1) 进水部分设计:采用穿孔墙进水方式,穿孔墙过水断面总面积: (4.9)10vq式中 为过孔流速,0.080.10m/s 取 0.1m/s1v m2 94. 61 . 0694. 00孔眼个数 n=6.94/0.150.08=578 ,孔眼尺寸选 15cm8cm。 进水水头损失: gvh2211(4.10
47、)式中 局部损失系数,取 2那么,=0.001 此处取 0.05mgvh2211(2)出水部分设计:采用指型槽出口 )(21bqql(4.11)式中 l指型槽长;q沉淀池处理水量 m/d;b沉淀池宽 mq设计单位堰宽负荷,宜采用 120480m/(m2 d)总长 l=(60000/480-16.7)/2=54.15; 取 56m设 4 个,单长为 14m。4.4.3 放空管m 52. 0360022 . 3946 .167 . 07 . 05 . 05 . 0tblhd(4.12)管径取 dn600,管材选用铸铁。4.4.4 排泥设备吸泥机采用桁车泵吸式吸泥机吸泥机,型号为 xhjb-17,驱
48、动功率20.75kw。4.5 臭氧处理臭氧处理系统主要由气源制备、臭氧发生、接触反应和尾气破坏四部分的组成臭氧接触氧化池,采用 2 个。4.5.1 池体体积尺寸 60水tqv (4.13)式中 t水力停留时间 minq水流量 m/hm375602500960水tqv面积 bbhtqf60水(4.14)式中 hb扩散器以上水深,经验 57 米水75537560bbhtqfmbflb15575各反应室水力停留时间分别为 2min,5min,2min。各反应室长度为lttlrr各反应室长度为分别采用长度为:3.5m,8m,3.5m。4.5.2 气源制备气源制备部分是臭氧处理系统中的前置系统,它的作用
49、是为臭氧发生器提供所需的质量适宜和数量足够的原料气体.本设计气源形式选用 vpsa 现场制氧为主要形式,同时配置液氧储备系统作为 vpsa 设备检修停产或满负荷峰值时产量不足的备用。vpsa(vacuum pressure swing adsorption 的简称,中文含义是真空变压吸附技术)的基本原理是:利用固体吸附剂对气体组分吸附的明显选择性和扩散性的差异,通过气源在接近常压下在不同吸附剂中的循环变化,其解吸(或再生)采用真空抽吸的方式来实现气体的分离过程。现场制氧设备由美国 airsep 公司提供(1)氧发生系统氧发生系统是臭氧处理系统中的设备核心,其作用是生产消毒工艺所需的数量足够的臭
50、氧气体。臭氧发生车间配备四台臭氧发生器,选用的是瑞士 ozonia 公司的产品,总臭氧发生量为 kg/h,每台设备的发生量为 kg/h。臭氧发生系统主要由以下部分组成:臭氧发生器、发生器供电单元(简称psu,含变频、变压、冷却系统)、供配电系统(简称 pdb)、plc 控制系统、仪表空气和氮气投加系统、相关仪表阀门、管道等。4.5.3 臭氧布气系统计算(1)每小时投配的总臭氧量: (4.15)1000coqc水水中所需臭氧投加量,g/moc根据其他工程经验,选用 120g/mgqco300100012025001000c水(2)水中所需投加臭氧化气流量 (4.16)1y1000c气c式中 发生
51、器所产生的臭氧化气浓度,一般 1020g/m1y31m20000151000300y1000c气cm1228020000614. 0614. 018. 0273103. 020273气气气)(qqqq水中所需的投加发生器在工作状态的臭氧化气流量气qq微孔扩散元件数 n=35/0.6=25 布置成 6 排,每排 4 个,间距 0.6m。4.6 活性炭过滤活性炭滤池采用普通快滤池形式,优点为:(1) 、有成熟的运转经验,运行稳妥可靠(2) 、采用大阻力配水系统,单池面积可做得较大;池深较浅(3) 、可采用降速过滤,水质较好缺点为:(1) 、阀门多 (2) 、必须设有全套冲洗设施4.6.1 滤池尺寸
52、计算(1)滤池总面积 (4.17)qfvt (4.18)001ttntnt 式中 f滤池总面积(m2) ; q设计水量(m3/d) ; v设计滤速(m/h) ; t滤池每日的实际工作时间(h) ; t0滤池每日的工作时间(h) ; t0滤池每日冲洗后停用和排放初滤水时间(h) ; t1 滤池每日冲洗时间(h) ; n滤池的每日冲洗次数(次) 。设计中取 n=2 次,t1=0.1h,不考虑排放初滤水时间,即取 t0=0 242 0.123.8th 设计中选用单层滤料活性炭滤池,取 v=10 m/h 22 .5048 .2310120000mf单池面积: ffn 式中 f单池面积(m2) ; f滤
53、池总面积(m2) ; n滤池个数(个) ,一般采用 n2 个。设计中取 n=8 个,布置成双行排列 263.02582 .504mf设计中取 l=13m,b=5m,滤池的实际面积为 135=65m2,实际流速 hmv/9.78 .23658120000当一座滤池检修时,其余滤池的强制滤速 (4.19)1nvvn式中 当一座滤池检修时其余滤池的强制滤速(m/h) ;一般采用v1014 m/h。 hmv/08.11189.78(2)滤池高度 1234hhhhh(4.20)式中 h滤池高度(m),一般采用 3.203.60;h1承托层高度(m) ;h2滤料层高度(m) ;h3滤层上水深(m) ;h4
54、超高(m),一般采用 0.3。设计中取 h1=0.40 m,h2=0.70 m,h3=1.80 m,h4=0.30 m 0.400.70 1.800.303.20hm4.6.2 配水系统计算最大粒径滤料的最小流态化流速: (4.21)2.311.3101.310.540.54012.26(1)mfmdvm式中最大粒径滤料的最小流态化流速(cm/s) ;mfv d滤料粒径(m) ; 球度系数; 水的动力粘度(n.s)/ m2 m0滤料的孔隙率。设计中取 d=0.0012m,=0.98, m0=0.38,水温 20时的动力粘度=0.001(n.s)/ m21.312.311.310.540.540
55、.00120.3812.261.08/0.980.001(1 0.38)mfvcm s反冲洗强度: (4.22)10mfqkv式中 q反冲洗强度l/(s.m2),一般采用 1215 l/(s.m2); k安全系数,一般采用 1.11.3.设计中取 k=1.3 88.1108. 11 . 110q反冲洗水流量 .gqf q(4.23)式中 反冲洗干管流量(l/s) 。gqslqg/77288.1165干管始端流速: 32410.ggqvd(4.24)式中 干管始端流速(m/s) ,一般采用 1.01.5 m/s;gv 反冲洗水量(l/s) ;gq d干管管径(m) 。设计中取 d=1000mm,
56、管材为铸铁。 smvg/98. 0114. 377 . 04配水支管计算: abnj 2(4.25)式中 单池中支管根数(根) ;jn b滤池宽度(m) ; a支管中心间距(m) ,一般采用 0.250.30m;设计中取 a=0.30m 根4025. 052jn单根支管入口流量: (4.26)gjjqqn式中 单根支管入口流量(l/s) 。jq slqj/52 . 9140077支管入口处流速: 3210.4jjjqvd(4.27)式中 支管入口流速(m/s) ,一般采用 1.52.0m/s;jv 支管管径(m) ;jd设计中取=0.1mjdsmvj/45. 201. 014. 392501.
57、 04单根支管长度: (4.28)dllj21 式中 单根支管长度(m) ;jl b单个滤池长度(m) ; d配水干管管径(m) ;设计中取 b=6m,d=1.0m mlj5 . 411021 配水支管上孔口面积: (4.29).kfk f式中 配水支管上孔口面积(m2)kf k配水支管上孔口面积与滤池面积 f 之比,一般采用 0.2%0.25%;设计中取 k=0.25%, 23751 . 065%25. 0mfk配水支管上流速: (4.30)gkkqvf式中 配水支管上流速(m/s) ,一般采用 5.06.0m/skv smvk/6 . 53751 . 077 . 0单个孔口面积: 24kk
58、fd式中 配水支管上单个孔口面积(mm2);kf 配水支管上孔口直径(mm) ,一般采用 912mm。kd设计中取=9mmkd 225 .6394fmmk孔口总数: (4.31)kkkfnf式中 孔口总数(个) kn个19685 .63125000kn每根支管上的孔口数: kkjnnn(4.32)式中 每根支管上的孔口数(个)kn 个49401968kn 支管上孔口布置成二排,与垂线成 45夹角向下交错排列。 孔口中心间距: / 2jkklan(4.33)式中 孔口中心间距(m)ka设计中取=4.5m,=49 个jlkn mak05. 02/495 . 4孔口平均水头损失: (4.34)21(
59、)210kqhgk式中 孔口平均水头损失(m) ;kh q冲洗强度l/(s.m2); 流量系数,与孔口直径和壁厚的比值有关; k支管上孔口总面积与滤池面积之比,一般采用 0.2%0.25%.设计中取=5mm,k=0.25%,则孔口直径与壁厚之比,选用流量系数=0.68219()1.82105kkdqhgk 2114()3.462 9.8 10 0.68 0.025khm对大阻力配水系统,要求有其支管长度与直径之比不大于 60。 jljd 满足要求。60451 . 05 . 4jjdl 对大阻力配水系统,要求配水支管上孔口总面积与支管横截面面积之和的比值小于 0.5,0.5jkjffn 2.4j
60、jfd(4.35)式中 配水支管的横截面积(m2)jf ,满足要求。5 . 039. 001. 0440125. 0jjkfnf4.6.3 洗砂排水槽(1)洗砂排水槽尺寸中心间距: nla 0(4.36) 式中 洗砂排水槽中心距(m)0a n洗砂排水槽数(条),取 7 条。 ma.8517310每条洗砂排水槽长度:l0=5m每条洗砂排水槽的排水量: nqqg0(4.37)式中 每条洗砂排水槽的排水量(l/s);0q 单个滤池的反冲洗水量(l/s);gq n洗砂排水槽总数(条) 。 slq/01170770(2)洗砂排水槽断面模数洗砂排水槽采用三角形标准断面。 洗砂排水槽断面模数 0012100
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025委托收购合同专业版范文
- 2025设立有限责任公司出资合同
- 2025私人的转让合同
- 线上医疗服务的发展现状与未来趋势分析
- 商场教师节促销活动策划方案
- 2025年湘师大新版必修三语文下册阶段测试试卷
- 2025年浙教版七年级生物下册月考试卷含答案
- 2025年湘教新版选择性必修3物理上册阶段测试试卷含答案
- 2025年度智能家居铺面转租合同协议4篇
- 二零二五年度民办学校教师信息技术应用聘用合同4篇
- GB/T 45120-2024道路车辆48 V供电电压电气要求及试验
- 春节文化常识单选题100道及答案
- 华中师大一附中2024-2025学年度上学期高三年级第二次考试数学试题(含解析)
- 12123交管学法减分考试题及答案
- 2025年寒假实践特色作业设计模板
- 24年追觅在线测评28题及答案
- 高考满分作文常见结构
- 心肌梗死诊疗指南
- 食堂项目组织架构图
- 原油脱硫技术
- GB/T 2518-2019连续热镀锌和锌合金镀层钢板及钢带
评论
0/150
提交评论