CE认证的EMC指令涉及标准emc_第1页
CE认证的EMC指令涉及标准emc_第2页
CE认证的EMC指令涉及标准emc_第3页
CE认证的EMC指令涉及标准emc_第4页
已阅读5页,还剩51页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、CE认证的EMC指令涉及标准emcCommission communication in the framework of the implementation of the Council directive89/336/EEC(2004/C98/05)(Text with EEA relevance)(Publication of titles and references of harmonized standards under the directive)ESO(1)Reference and title of the standard Reference document Refe

2、rence of thesuperseded standardDate of cessation of presumption of conformity of the superseded standardNote1Cenelec EN50065-1:2001Signalling on low-voltage electrical installations in the frequency range3kHz to148,5kHzPart1: General requirements,frequency bands and electro-magnetic disturbances EN5

3、0065-1:1991+A1:1992+A2:1995+A3:1996Note2.1Date expired(1.4.2003)Cenelec EN50065-2-1:2003Signalling on low-voltage electrical installations in the frequency range3kHz to148,5kHzPart2-1: Immunity requirements for mains communications equipment and systems operating in the range of frequencies95kHz to1

4、48,5kHz and intended for use in residential,commercial and light industrial environments Relevant genericstandard(s)Note2.31.10.2004Cenelec EN50065-2-2:2003Signalling on low-voltage electrical installations in the frequency range3kHz to148,5kHzPart2-2: Immunity requirements for mains communications

5、equipment and systems operating in the range of frequencies95kHz to148,5kHz and intended for use in industrial environments Relevant genericstandard(s)Note2.31.10.2004Cenelec EN50065-2-3:2003Signalling on low-voltage electrical installations in the frequency range3kHz to148,5kHzPart2-3: Immunity req

6、uirements for mains communications equipment and systems operating in the range of frequencies3kHz to95kHz and intended for use by electricity suppliers and distributors Relevant genericstandard(s)Note2.31.8.2004Cenelec EN50081-1:1992Electromagnetic compatibilityGeneric emissionstandardPart1:Residen

7、tial,commercial andlight industryNoneCenelec EN50081-2:1993Electromagnetic compatibilityGeneric emissionstandardPart2:Industrial environmentNoneCenelec EN50082-1:1997Electromagnetic compatibilityGeneric immunity standardPart1:Residential,commercial and light industry EN50082-1:1992Note2.1Date expire

8、d(1.7.2001)Cenelec EN50083-2:2001Cable networks for television signals,sound signals and interactive servicesPart2:Electromagnetic compatibility for equipment EN50083-2:1995+A1:1997Note2.1Date expired(1.1.2004)Cenelec EN50090-2-2:1996Home and Building Electronic Systems(HBES)Part Relevant generic Da

9、te expiredESO(1)Reference and title of the standard Reference document Reference of thesuperseded standard presumption of conformity of the superseded standardNote1Cenelec EN50091-2:1995Uninterruptible power systems(UPS)Part2:EMC requirements Relevant genericstandard(s)Note2.3Date expired(1.3.1999)C

10、enelec EN50130-4:1995Alarm systemsPart4:Electromagnetic compati-bilityProduct family standard:Immunity requirements for components of fire,intruder and social alarm systems Relevant genericstandard(s)Note2.3Date expired(1.1.2001)Amendment A1:1998to EN50130-4:1995Note3Date expired(1.1.2001)Amendment

11、A2:2003to EN50130-4:1995Note3 1.9.2007 Cenelec EN50148:1995Electronic taximeters Relevant genericstandard(s)Note2.3Date expired (15.12.1995)Cenelec EN50199:1995Electromagnetic compatibility(EMC)Product standard for arc welding equipment Relevant genericstandard(s)Note2.3Date expired(1.7.1996)Cenelec

12、 EN50263:1999Electromagnetic compatibility(EMC)Product standard for measuring relays and protection equipment Relevant genericstandard(s)Note2.3Date expired(1.8.2002)Cenelec EN50270:1999Electromagnetic compatibilityElectrical apparatus for the detection and measurement of combustible gases,toxic gas

13、es or oxygen Relevant genericstandard(s)Note2.3Date expired(1.10.2001)Cenelec EN50293:2000Electromagnetic compatibilityRoad traffic signal systemsProduct standard Relevant genericstandard(s)Note2.3Date expired(1.4.2003)Cenelec EN50295:1999Low-voltage switchgear and controlgearController and device i

14、nterface systemsActuator Sensor interface(AS-i)Relevant genericstandard(s)Note2.3Date expired(1.12.1999)Cenelec EN50370-2:2003Electromagnetic compatibility(EMC)Product family standard for machine toolsPart2: Immunity Relevant genericstandard(s)Note2.31.11.2005Cenelec EN55011:1998Industrial,scientifi

15、c and medical(ISM)radio-frequency equipmentRadio disturbance charac-teristicsLimits and methods of measurement CISPR11:1997(Modified)EN55011:1991+A1:1997+A2:1996Note2.1Date expired(1.1.2001)Amendment A1:1999to EN55011:1998CISPR11:1997/A1:1999Note3Date expired(1.8.2002)ESO(1)Reference and title of th

16、e standard Reference document Reference of thesuperseded standard presumption of conformity of the superseded standardNote1Cenelec EN55012:2002Vehicles,boats and internal combustion engine driven devicesRadio disturbance characteristics Limits and methods of measurement for the protection of receive

17、rs except those installed in the vehicle/boat/device itself or in adjacent vehicles/boats/ devicesNote8CISPR12:2001Relevant genericstandard(s)Note2.31.2.2005Cenelec EN55013:1990Limits and methods of measurement of radio disturbance characteristics of broadcast receivers and associated equipment CISP

18、R13:1975+A1:1983(Modified)NoneAmendment A12:1994to EN55013:1990Note3Date expired(31.12.1998)Amendment A13:1996to EN55013:1990Note3Date expired(1.6.1999)Amendment A14:1999to EN55013:1990Note3Date expired(1.8.2001) Cenelec EN55013:2001Sound and television broadcast receivers and associated equipmentRa

19、dio disturbance charac-teristicsLimits and methods of measurement CISPR13:2001(Modified)EN55013:1990and its amendmentsNote2.11.9.2004Amendment A1:2003to EN55013:2001CISPR13:2001/A1:2003Note3 1.4.2006 Cenelec EN55014-1:2000Electromagnetic compatibilityRequirements for household appliances,electric to

20、ols and similar apparatusPart1:Emission CISPR14-1:2000EN55014-1:1993+A1:1997+A2:1999Note2.1Date expired(1.8.2003)Amendment A1:2001to EN55014-1:2000CISPR14-1:2000/A1:2001Note3 1.10.2004Amendment A2:2002to EN55014-1:2000CISPR14-1:2000/A2:2002Note3 1.10.2005 Cenelec EN55014-2:1997Electromagnetic compat

21、ibilityRequirements for household appliances,electric tools and similar apparatusPart2:ImmunityProduct family standard CISPR14-2:1997EN55104:1995Note2.1Date expired(1.1.2001)Amendment A1:2001to EN55014-2:1997CISPR14-2:1997/A1:2001Note3 1.12.2004 Cenelec EN55015:2000Limits and methods of measurement

22、of radio disturbance characteristics of electrical lighting and similar equipment CISPR15:2000EN55015:1996+A1:1997+A2:1999Note2.1Date expired(1.8.2003)Amendment A1:2001to EN55015:2000CISPR15:2000/A1:2001Note3 1.12.2004ESO(1)Reference and title of the standard Reference document Reference of thesuper

23、seded standard presumption of conformity of the superseded standardNote1Cenelec EN55020:1994Electromagnetic immunity of broadcast receivers and associated equipment EN55020:1988Note2.1Date expired(31.12.1998)Amendment A11:1996to EN55020:1994Note3Date expired(1.6.1999)Amendment A13:1999to EN55020:199

24、4Note3Date expired(1.8.2001)Amendment A14:1999to EN55020:1994Note3Date expired(1.8.2001)Amendment A12:1999to EN55020:1994Note3Date expired(1.8.2002) Cenelec EN55020:2002Sound and television broadcast receivers and associated equipmentImmunity characteristicsLimits and methods of measurement CISPR20:

25、2002EN55020:1994and its amendmentsNote2.11.4.2005Amendment A1:2003to EN55020:2002CISPR20:2002/A1:2002Note3 1.12.2005 Cenelec EN55022:1994Limits and methods of measurement of radio disturbance characteristics of information technology equipment CISPR22:1993EN55022:1987Note2.1Date expired(31.12.1998)A

26、mendment A1:1995to EN55022:1994CISPR22:1993/A1:1995Note3Date expired(31.12.1998)Amendment A2:1997to EN55022:1994CISPR22:1993/A2:1996(Modified)Note3Date expired(31.12.1998)Cenelec EN55022:1998Information technology equipmentRadio disturbance characteristicsLimits and methods of measurement CISPR22:19

27、97(Modified)EN55022:1994and its amendmentsNote2.11.8.2005Amendment A1:2000to EN55022:1998CISPR22:1997/A1:2000Note3 1.8.2005Amendment A2:2003to EN55022:1998CISPR22:1997/A2:2002Note3 1.12.2005 Cenelec EN55024:1998Information technology equipmentImmunity characteristicsLimits and methods of measurement

28、 CISPR24:1997(Modified)Relevant genericstandard(s)Note2.3Date expired(1.7.2001)Amendment A1:2001to EN55024:1998CISPR24:1997/A1:2001Note3 1.10.2004Amendment A2:2003to EN55024:1998CISPR24:1997/A2:2002Note3 1.12.2005 Cenelec EN55103-1:1996Electromagnetic compatibilityProduct family standard for audio,v

29、ideo,audio-visual and enter-tainment lighting control apparatus for professional usePart1:Emission Relevant genericstandard(s)Note2.3Date expired(1.9.1999)Cenelec EN55103-2:1996Electromagnetic compatibilityProduct family standard for audio,video,audio-visual and enter-Relevant genericstandard(s)Date

30、 expired(1.9.1999)ESO(1)Reference and title of the standard Reference document Reference of thesuperseded standard presumption of conformity of the superseded standardNote1Cenelec EN60034-1:1998Rotating electrical machinesPart1:Rating and performance IEC60034-1:1996(Modified)Amendment A11:2002to EN6

31、0034-1:1998Relevant genericstandard(s)Note2.31.7.2005 Cenelec EN60204-31:1998Safety of machineryElectrical equipment of machinesPart31:Particular safety and EMC requirements for sewing machines,units and systems IEC60204-31:1996(Modified)Relevant genericstandard(s)Note2.3Date expired(1.6.2002)Cenele

32、c EN60439-1:1999Low-voltage switchgear and controlgear assemblies Part1:Type-tested and partially type-tested assemblies IEC60439-1:1999EN60439-1:1994+A11:1996Note2.1Date expired(1.8.2002)Cenelec EN60521:1995Class0,5,1and2alternating-current watt-hour meters IEC60521:1988Relevant genericstandard(s)N

33、ote2.3Date expired(15.7.1995)Cenelec EN60669-2-1:1996Switches for household and similar fixed-electrical installationsPart2:Particular requirementsSection1:Electronic switches IEC60669-2-1:1994+A1:1994+A2:1995(Modified)Amendment A11:1997to EN60669-2-1:1996Relevant genericstandard(s)Note2.3Date expir

34、ed (1.6.1999)Cenelec EN60669-2-1:2000Switches for household and similar fixed electrical installationsPart2-1:Particular requirementsElectronic switches IEC60669-2-1:1996+A1:1997(Modified)EN60669-2-1:1996and its amendmentNote2.11.10.2005Amendment A2:2001to EN60669-2-1:2000IEC60669-2-1:1996/A2:1999(M

35、odified)Note3 1.10.2005 Cenelec EN60669-2-2:1997Switches for household and similar fixed electrical installationsPart2:Particular requirementsSection2:Electromagnetic remote-control switches (RCS)IEC60669-2-2:1996Relevant genericstandard(s)Note2.3Date expired(1.6.1999)Cenelec EN60669-2-3:1997Switche

36、s for household and similar fixed electrical installationsPart2-3:Particular requirementsTime-delay switches(TDS)IEC60669-2-3:1997EN60669-2-3:1996Note2.1Date expired(1.6.1999)Cenelec EN60687:1992Alternating current static watt-hour meters for active IEC60687:1992Relevant generic Date expiredESO(1)Re

37、ference and title of the standard Reference document Reference of thesuperseded standard presumption of conformity of the superseded standardNote1Cenelec EN60730-1:1995Automatic electrical controls for household and similar usePart1:General requirements IEC60730-1:1993(Modified)Amendment A11:1996to

38、EN60730-1:1995Relevant genericstandard(s)Note2.3Date expired (1.1.1998)Amendment A17:2000to EN60730-1:1995Note3Date expired(1.10.2002) Cenelec EN60730-1:2000Automatic electrical controls for household and similar usePart1:General requirementsNote7IEC60730-1:1999(Modified)EN60730-1:1995and its amendm

39、entsCenelec EN60730-2-5:1995Automatic electrical controls for household and similar usePart2:Particular requirements for automatic electrical burner control systems IEC60730-2-5:1993(Modified)EN60730-1:1995and its amendmentsNote2.3Date expired(15.12.2000)Cenelec EN60730-2-6:1995Automatic electrical

40、controls for household and similar usePart2:Particular requirements for automatic electrical pressure sensing controls including mechanical requirements IEC60730-2-6:1991(Modified)Amendment A1:1997to EN60730-2-6:1995IEC60730-2-6:1991/A1:1994(Modified)Note3Date expired(15.12.2003)Cenelec EN60730-2-7:

41、1991Automatic electrical controls for household and similar usePart2:Particular requirements for timers and time switches IEC60730-2-7:1990(Modified)Amendment A1:1997to EN60730-2-7:1991IEC60730-2-7:1990/A1:1994(Modified)Note3Date expired(1.1.2004)Cenelec EN60730-2-8:1995Automatic electrical controls

42、 for household and similar usePart2:Particular requirements for elec-trically operated water valves,including mechanical requirements IEC60730-2-8:1992(Modified)Amendment A1:1997to EN60730-2-8:1995IEC60730-2-8:1992/A1:1994(Modified)Note3Date expired(1.1.2004)Amendment A2:1997to EN60730-2-8:1995IEC60

43、730-2-8:1992/A2:1997Note3Date expired(1.1.2004)Cenelec EN60730-2-8:2002Automatic electrical controls for household and similar usePart2-8:Particular requirements for electrically operated water valves,including mechanical requirements IEC60730-2-8:2000(Modified)EN60730-2-8:1995and its amendmentsNote

44、2.11.12.2008Amendment A1:2003to EN60730-2-8:2002IEC60730-2-8:2000Note3 1.12.2008ESO(1)Reference and title of the standard Reference document Reference of thesuperseded standard presumption of conformity of the superseded standardNote1Cenelec EN60730-2-9:1995Automatic electrical controls for househol

45、d and similar usePart2:Particular requirements for temperature sensing controls IEC60730-2-9:1992(Modified)Amendment A1:1996to EN60730-2-9:1995IEC60730-2-9:1992/A1:1994(Modified)Note3Date expired(1.1.2004)Amendment A2:1997to EN60730-2-9:1995IEC60730-2-9:1992/A2:1994(Modified)Note3Date expired(1.1.20

46、04)Cenelec EN60730-2-9:2002Automatic electrical controls for household and similar usePart2-9:Particular requirements for temperature sensing controls IEC60730-2-9:2000(Modified)EN60730-2-9:1995and its amendmentsNote2.11.12.2008Amendment A1:2003to EN60730-2-9:2002IEC60730-2-9:2000/A1:2002(Modified)N

47、ote3 1.12.2008Cenelec EN60730-2-11:1993Automatic electrical controls for household andsimilar usePart2:Particular requirements forenergy regulatorsIEC60730-2-11:1993Amendment A1:1997to EN60730-2-11:1993IEC60730-2-11:1993/A1:1994(Modified)Note3Date expired(1.7.2000)Cenelec EN60730-2-13:1998Automatic

48、electrical controls for household and similar usePart2-13:Particular requirements for humidity sensing controls IEC60730-2-13:1995(Modified)EN60730-1:1995and its amendmentsNote2.3Date expired(1.8.2001)Cenelec EN60730-2-14:1997Automatic electrical controls for household and similar usePart2-14:Partic

49、ular requirements for electric actuators IEC60730-2-14:1995(Modified)EN60730-1:1995and its amendmentsNote2.31.6.2004Amendment A1:2001to EN60730-2-14:1997IEC60730-2-14:1995/A1:2001Note3 1.7.2008 Cenelec EN60730-2-18:1999Automatic electrical controls for household and similar usePart2:Particular requi

50、rements for automatic electrical water and air flow sensing controls,including mechanical requirements IEC60730-2-18:1997(Modified)EN60730-1:1995and its amendmentsNote2.3Date expired(1.4.2002)Cenelec EN60870-2-1:1996Telecontrol equipment and systemsPart2: Operating conditionsSection1:Power supply an

51、d electromagnetic compatibility IEC60870-2-1:1995Relevant genericstandard(s)Note2.3Date expired(1.9.1996)Cenelec EN60945:1997Maritime navigation and radiocommunication IEC60945:1996EN60945:1995Date expiredESO(1)Reference and title of the standard Reference document Reference of thesuperseded standar

52、d presumption of conformity of the superseded standardNote1Cenelec EN60945:2002Maritime navigation and radiocommunication equipment and systemsGeneral requirementsMethods of testing and required test results IEC60945:2002EN60945:1997Note2.11.10.2005Cenelec EN60947-1:1999Low-voltage switchgear and co

53、ntrolgearPart1: General rulesNote6IEC60947-1:1999(Modified)EN60947-1:1997Note2.1Date expired(1.11.2001)Amendment A2:2001to EN60947-1:1999IEC60947-1:1999/A2:2001Note3 1.12.2004 Cenelec EN60947-2:1996Low-voltage switchgear and controlgearPart2: Circuit-breakers IEC60947-2:1995Relevant genericstandard(

54、s)Note2.3Date expired(1.10.1997)Amendment A1:1997to EN60947-2:1996IEC60947-2:1995/A1:1997EN60947-2:1996/A11:1997Note3Date expired(1.8.1998)Amendment A2:2001to EN60947-2:1996IEC60947-2:1995/A2:2001Note3 1.7.2004 Cenelec EN60947-2:2003Low-voltage switchgear and controlgearPart2: Circuit-breakers IEC60

55、947-2:2003EN60947-2:1996and its amendmentsNote2.11.6.2006Cenelec EN60947-3:1999Low-voltage switchgear and controlgearPart3: Switches,disconnectors,switch-disconnectors and fuse-combination units IEC60947-3:1999EN60947-3:1992+A1:1995Note2.1Date expired(1.1.2002)Amendment A1:2001to EN60947-3:1999IEC60

56、947-3:1999/A1:2001Note3Date expired(1.3.2004)Cenelec EN60947-4-1:1992Low-voltage switchgear and controlgearPart4-1: Contactors and motor-startersElectromechanical contactors and motor-starters IEC60947-4-1:1990Relevant genericstandard(s)Note2.3Date expired(1.10.1997)Amendment A2:1997to EN60947-4-1:1992IEC60947-4-1:1990/A2:1996Note3Date expired(1.10.1997)Cenelec EN60947-4-1:2001Low-voltage switchgear and

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论