已阅读5页,还剩37页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
设 计 概 况本设计是新区十层办公楼给排水及消防设计。本设计主要包括:室内给水系统设计、室内排水系统设计、室内消火栓系统设计和自喷系统设计等。尤其是我国现在水资源缺乏,全国大部分的城市水资源缺乏,这已成为制约我国城市发展和经济建设的主要因素。所以在满足楼房整体用水的同时,水资源的节约也是非常重要的。在选择方案时,选择最佳方案的要求是运行可靠、投资省、节水节能、无污染、维护管理方便、使用时间长等。本设计给水采用分区给水方式,其中低区由市政管网直接供水,高区为单设水泵的给水方式,建筑内部生活污废水采用合流制排出,室内的消防设计采用消火栓和自喷系统联合的方式。关 键 词:办公楼 给排水 消火栓 自喷 毕业设计Design OverviewThis design is water supply and drainage and fire engineering design for new area ten layers office building. This design includes: indoor water system design, interior drainage system design, interior hydrant system design and the automatic sprinkler system, etc. Especially the shortage of water resources in China, now water shortage in most cities, it has become the restriction of urban development and the main factors of economic construction. So meet whole water use, at the same time saving water is also very important. In the options, select the best scheme requirement is reliable operation, investment saving, saving energy and water, no pollution, maintenance management convenient, long using life, etc. This design water using zoning water-supply modes, lower water supply is by direct municipal pipeline, high area adopt single set pump water-supply modes, building interior drainage used mixing system. Fire-fighting system used combined way of fire hydrant and automatic sprinkler system. Keywords: office building water supply and drainage hydrant automatic sprinkler graduation design 目 录1 绪论11.1 工程概况11.2 设计目的及意义11.3 设计内容及依据12设计各系统描述22.1 生活给水系统22.1.1 给水系统选择22.1.2 系统组成22.1.3 主要设备及构筑物22.1.4 给水管道布置及设备安装22.2室内排水系统32.2.1排水系统的选择32.2.2 系统组成32.2.3 主要设备及构筑物32.2.4 排水管道布置及设备安装32.3 消防系统42.3.1 消防给水系统选择42.3.2 系统组成42.3.3 主要设备及构筑物42.3.4 消防管道布置及设备安装43设计各系统水力计算53.1 生活给水系统53.1.1 计算公式及设计参数53.1.2 给水管网水力计算73.2 排水系统173.2.1 计算公式及参数173.2.2 排水管网水力计算193.3 消火栓给水系统253.3.1 计算公式及参数253.3.2消防管网水力计算263.4 自动喷水系统293.4.1 计算公式及参数293.4.2 自喷系统管网水力计算294 设计各系统设备选型334.1 生活给水系统334.2 排水系统334.3 消火栓给水系统33III4.4 自动喷水灭火系统34结 论35致 谢36参 考 文 献3733内蒙古农业大学本科毕业设计 1 绪论1 绪论1.1 工程概况内蒙古呼和浩特市新城区拟建一栋十层办公楼,结构为框架结构,总建筑面积41840m,总高度38.5m,其各层平面图及详细资料见所提供图纸。楼内用水设备有洗脸盆,坐便器,蹲便器,小便器,拖布池,淋浴器。本建筑四周都有街道,街道下方均有市政给水管网,据外墙的距离为5m,接管点埋深1.8m,管径200mm,管材为铸铁管,常年提供的资用水头0.30MPa。本地区冻土深度为1.5m。室内粪便污水需经化粪池处理后方可排入城市下水道,接管点为管顶平接,埋设深度为1.830m,管径300mm,管材为混凝土。1.2 设计目的及意义培养提高学生综合运用在校所学的基础理论、基础知识和基础技能解决工程实际问题的能力,以达到总结、巩固扩大和深化所学的知识;培养和调动学生学习的主动性和积极性;激发学生创新精神;使学生进一步了解我国基本建设方面的政策,提高学生对国家建设的责任感。通过毕业设计的综合训练,培养提高学生调查研究、查阅文献、收集运用知识的能力;综合分析、制定设计方案的能力;并进一步培养提高学生的计算、绘图、运用工具书和编写说明书的技能,以及运用计算机计算、绘图和进行外语翻译的能力。1.3 设计内容本设计主要是新区十层办公楼给排水及消防设计。主要是室内给水系统设计及水力计算、室内排水系统设计及水力计算、室内消防系统及其水力计算、自喷系统及其水力计算,给水、排水、消防、自喷系统管材及设备的选择及设备安装等。内蒙古农业大学本科毕业设计 2 设计各系统描述2设计各系统描述2.1 生活给水系统2.1.1 给水系统选择本地区市政管网水压0.30MPa。本设计的办公楼一层层高4m,二到十层层高3.5m,地下室层高3m。所以总建筑高度为35.5m。由于本楼的设计高度是38.5m,市政管网的压力为30m,不足以满足全楼的给水要求。所以本设计采用分区给水方式,其中一到四层为低区由市政管网直接供水,五到十层为高区由设在地下室内的贮水池水泵加压供水。两分区均采用下行上给式供水。2.1.2 系统组成给水系统由引入管,水表节点,贮水池,水泵,室内给水管道,给水附件等组成。给水管采用给水不锈钢管。2.1.3 主要设备及构筑物主要设备:水表,水泵,洗脸盆,坐便器,蹲便器,小便器,拖布池,淋浴器,水龙头。构筑物主要是贮水池。2.1.4 给水管道布置及设备安装(1)室内给水管道布置成枝状管网,单向供水。(2)给水管道不得敷设在烟道、风道、电梯井内、排水沟内。给水管道不宜穿越橱窗、壁柜、给水管道不得穿过大便槽和小便槽,且立管离大、小便槽端部不得小于0.5m。(3)给水管道不宜穿越伸缩缝、沉降缝、变形缝。如必须穿越时,应设置补偿管道伸缩和剪切变形的装置。给水管道暗设时,应符合下列要求:(1)不得直接敷设在建筑物结构层内;(2)干管和立管应敷设在吊顶、管井、管窿内,支管宜敷设在楼(地)面的找平层内或沿墙敷设在管槽内;(3)敷设在找平层或管槽内的给水支管的外径不宜大于25mm;(4)敷设在找平层或管槽内的给水管管材宜采用塑料、金属与塑料复合管材或耐腐蚀的金属管材;(5)敷设在找平层或管槽内的管材,如采用卡套式或卡环式接口连接的管材,宜采用分水器向各卫生器具配水,中途不得有连接配件,两端接口应明露。地面宜有管道位置的临时标识。2.2室内排水系统2.2.1排水系统的选择建筑内部排水体制分为分流制和合流制两种。建筑内部分流排水是指居住建筑和公共建筑中的粪便污水和生活废水各自由单独的排水管道系统排除。建筑内部合流排水是指建筑中两种或两种以上的污、废水合用一套排水系统排除。由于本设计对污、废水并无特殊的要求,所以采用合流制将建筑内部的污废水排除。2.2.2 系统组成排水系统的组成包括卫生器具、排水管道、检查口、清扫口、室外排水管道、检查井、集水井、化粪池等。2.2.3 主要设备及构筑物主要设备:坐便器,小便器,洗脸盆,淋浴器,拖布池。构筑物:检查井,集水井,化粪池。2.2.4 排水管道布置及设备安装室内排水管道布置应力求管线短、转弯少,使污水以最佳水力条件排至室外管网;管道的布置不得影响、妨碍房屋的使用和室内各种设备的正常运行;管道的布置还应便于安装和维护管理,满足经济和美观的要求。除此之外,还应遵守以下原则:(1)排水管道一般宜在地下埋设或在地面上、楼板下明设,如建筑物有特殊要求时,可在管槽、管道井、管窿、管沟过吊顶内暗设,但应便于安装和维护。在室外气温较高、全年不冻结的地区,可沿建筑物外墙敷设。(2)排水管道不得布置在遇水引起燃烧、爆炸的原料、产品和设备的上方。(3)排水管道不得穿过沉降缝、伸缩缝烟道和风道。(4)排水立管不得穿越卧室、病房等对卫生、安静有较高要求的房间,并不宜靠近与卧室相邻的内墙。(5)排水立管宜靠近排水量最大的排水点。排水管道不宜穿越橱窗、壁橱。(6)架空管道不得敷设在对生产工艺或卫生有特殊要求的生产厂房内,以及食品、贵重商品仓库、通风小室和变配电间和电梯机房内。(7)排水横管不得布置在食堂、饮食业厨房的主副食操作烹调备餐的上方。当受条件限制不能避免时,应采取防护措施。(8)塑料排水管应避免布置在热源附近,如不能避免,并导致管道表面受热温度大于60时,应采取隔热措施。塑料排水立管与家用灶具边净距不得小于0.4m。(9)排水埋地管道不得穿越生产设备基础或布置在可能受重物压坏处。(10)塑料排水立管应避免布置在易受机械撞击处,如不能避免时应采取保护措施。排水管道的敷设形式包括明设和暗设。排水管道的敷设原则: (1)排水立管与排出管端部的连接,宜采用两个45度弯头或弯曲半径不小于4倍管径的90度弯头。排水管应避免轴线偏置,当受条件限制时,宜采用乙字管或两个45度弯头连接。(2)卫生器具排水管与排水横管垂直连接,应采用90度斜三通。(3)支管接入横干管、立管接入横干管时,宜在横干管管顶或其两侧45度范围内接入。塑料排水管道应根据环境温度变化、管道布置位置及管道接口形式等考虑设置伸缩节,但埋地或埋于墙体、混凝土柱体内的管道不应设置伸缩节。本设计采用污废合流,伸顶通气单立管系统。2.3 消防系统2.3.1 消防给水系统选择建筑消防系统根据使用灭火剂的种类和灭火方式可分为以下三种:1消火栓给水系统2自动喷水灭火系统3其他使用非水灭火剂的固定灭火系统,如二氧化碳灭火系统、干粉灭火系统、卤代烷灭火系统等。本设计采用消火栓和湿式自喷系统。2.3.2 系统组成建筑室内消火栓灭火系统由消火栓、水龙带、水枪、消防水箱、消防盘管(消防水喉设备)、水泵接合器、以及消防管道、高位水箱、消防水泵、水源等组成。自喷系统由水源、加压贮水设备、喷头、管网、报警装置等组成。2.3.3 主要设备及构筑物主要设备:见上述系统组成。构筑物:贮水池。2.3.4 消防管道布置及设备安装消防竖管的布置,应保证同层相邻两个消火栓的水枪的充实水柱同时达到被保护范围内的任何部位。每根消防竖管的直径应按通过的流量经计算确定,但不应小于100mm。室内消火栓给水系统应与自动喷水灭火系统分开设置,有困难时,可合用消防泵,但在自动喷水灭火系统的报警阀前(沿水流方向)必须分开设置。室内消火栓给水系统和自动喷水灭火系统应设水泵接合器。内蒙古农业大学本科毕业设计 3 设计各系统水力计算3设计各系统水力计算3.1 生活给水系统3.1.1 计算公式及设计参数(1)设计秒流量公式:给水管道的设计流量不仅是确定各管段管径,也是计算管道水头损失,进而确定给水系统需要压力的主要依据。建筑内的生活用水量在1昼夜、1h里都是不均匀的,保证用水,生活给水管道的设计流量应为建筑内卫生器具按用水最不利情况组合出流时的最大瞬时流量,又称设计秒流量。当前我国生活给水管网设计秒流量的计算方法,按建筑的用水特点分为两种:1)是用水时间集中,用水设备使用集中,同时给水百分数高的建筑,如工业企业生活间、公共浴室、洗衣房、公共食堂、实验室、影剧院、体育场等,可采用经验法,直接以卫生器具数量、额定流量和同时给水百分数计算设计秒流量,设计秒流量公式为: (式1)式中:q0 同类型的一个卫生器具给水额定流量,L/s; N0 同类型卫生器具数; b 卫生器具的同时给水百分数。用以上公式计算连接卫生器具少,其同时给水百分数又小的给水管段时,计算结果有时会小于该管段上1个最大卫生器具的给水额定流量,这时应采用1个最大卫生器具的给水额定流量作为设计秒流量。2)是用水时间长,用水设备使用不集中,同时给水百分数随卫生器具数量增加而减少的建筑,如住宅、集体宿舍、旅馆、宾馆、医院、幼儿园、办公楼、学校等。因生活用水量是通过室内各类卫生器具的配水装置使用放水来反映的,所以设计秒流量应按管段上所设卫生器具的数量,用统计学、概率理论来进行计算,但卫生器具种类多,且各种卫生器具的额定流量又不尽相同,为简化计算,将安装在污水盆上,支管直径为15mm的配水龙头的额定流量0.2L/s作为一个当量,其它卫生器具给水额定流量对它的比值,即为该卫生器具的当量值。这样便可把管段上不同类型卫生器具的流量,统一换算成当量总数,便于各管段设计秒流量的计算。适用于以上建筑的设计秒流量公式如下: (式2)式中:Ng 计算管段的卫生器具给水当量总数; 根据建筑用途而定的系数,可参阅建筑给排水设计规范。用以上公式计算连接卫生器具较少的给水管段时,由于和Ng值不同,其结果有时会小于该管段上1个最大卫生器具的给水额定流量,有时又会大于该管段上卫生器具给水额定流量的累加值,则应分别以该管段上1个最大卫生器具的给水额定流量和卫生器具给水额定流量的累加值,作为管段的计算秒流量,有大便器延时自闭冲洗阀的给水管段,大便器延时自闭冲洗阀的当量均以0.5计,计算得到附加1.10L/s的流量后,为该管段的给水设计秒流量。本设计是属于第二种情况:是用水时间长,用水设备使用不集中,同时给水百分数随卫生器具数量增加而减少的建筑办公楼。(2)引入管设计流量的确定:设计计算依据建筑给水排水设计规范(GB50015-2003)。建筑物的给水引入管的设计流量,符合下列要求:1)当建筑物内的生活用水全部由室外管网直接供水时,取建筑物内的生活用水设计秒流量。2)当建筑物内的生活用水全部自行加压供给时,引入管的设计流量应为贮水调节池的设计补水量。设计补水量不宜大于建筑物最高日最大时生活用水量,且不得小于建筑物最高日平均时生活用水量。3)当建筑物内的生活用水既有室外管网直接供水,又有自行加压供水时,应按本条第1、2款计算设计流量后,将两者叠加作为引入管的设计流量。本设计采用室内生活管道和消防管道各自独立的系统,引入管管径设计按建筑内所承担的用水设备的用水量确定。(3)水表的选择及水力计算:水表的选择包括确定水表的类型及口径,水表的类型应根据水表的特性和通过水表的水质、水量、水温、水压等情况选定。水表的口径,在通过的水量较均匀时,应使水表的设计流量不大于水表的公称流量,而在通过水量不均匀时,可按设计流量不大于水表的最大流量确定水表的口径。并应校核水表通过设计流量时,其水头损失应满足下表规定。 表1 水表水头损失允许值(kPa) 表 型正常用水时消 防 时旋翼式24.549.0螺翼式12.829.4水表的水头损失可按下式计算:(式3) 式中:水表的水头损失,; 计算管段的给水设计流量,; 水表的特性系数。一般由生产厂提供。也可按下式计算: 旋翼式水表 : (式4) 螺翼式水表:(为水表的过载流量,) (式5) (4)建筑内给水系统所需水压计算公式: (式6)式中:建筑内给水系统所需水压,; 引入管起点至最不利配水点位置高度所要求的静水压,; 管路的沿程与局部水头损失之和,; 水流通过水表时的水头损失,; 最不利配水点所需的最低工作压力,; 为不可预见因素留有余地而予以考虑的富裕水头,一般按20 计。3.1.2 给水管网水力计算本系统为分区给水系统,低区(1-4层)由市政管网直接供水,高区(5-10层)由设在地下室的变频调速水泵从贮水池抽水加压供水。(1)低区给水管道水力计算1)JL-1水力计算表2 给水管网水力计算(JL-1 1-4层) a=1.5计算管段编号当量总数设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(/m)管段长度L(m)管段沿程水头损失=iL()沿程水头损失累计120.750.15150.882.000.701.40231.500.30200.931.530.981.50342.300.45250.850.930.640.60453.301.64500.780.320.900.29564.301.72500.810.354.131.42676.801.88500.880.413.501.447813.602.21501.040.553.501.938920.402.45501.170.664.002.6491027.202.66501.250.773.202.46101127.202.66501.250.772.922.2515.92 图1 JL-1水力计算图 选择LXS-50旋翼式水表,其过载流量/h,性能系数为。则水表的水头损失所以建筑内JL-1给水系统所需水压为2)JL-2水力计算 图2 JL-2水力计算图表3 给水管网水力计算(JL-2 1-4层) a=1.5计算管段编号当量总数设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(/m)管段长度L(m)管段沿程水头损失=iL()沿程水头损失累计120.750.15150.882.000.701.40231.500.30200.931.530.701.07342.250.45250.850.931.461.36452.751.60500.750.300.900.27563.251.64500.770.314.311.33678.801.99500.940.462.671.23788.801.99500.940.463.501.618917.602.36501.110.613.502.1491026.402.64501.250.784.003.12101135.202.88501.380.923.202.94111235.202.88501.380.921.671.5418.00选择LXS-50旋翼式水表,其过载流量/h,性能系数为。 则水表的水头损失 所以建筑内JL-2给水系统所需水压为3)JL-3水力计算图3 JL-3水力计算图表4 给水管网水力计算(JL-3 1-4层) a=1.5计算管段编号当量总数Ng设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)沿程水头损失累计hy120.800.17151.002.606.1916.09231.550.32250.600.620.700.43342.300.45250.850.932.051.91453.301.64500.770.320.900.29564.301.72500.810.354.191.45676.801.88500.880.413.501.447813.602.20501.040.553.501.928920.402.45501.150.674.002.68续表91028.452.7501.270.813.22.59101128.452.7501.270.818.036.535.29选择LXS-50旋翼式水表,其过载流量/h,性能系数为。 则水表的水头损失 所以建筑内JL-3给水系统所需水压为4)JL-4水力计算 图4 JL-4水力计算图表5 给水管网水力计算(JL-4 1-4层) a=1.5计算管段编号当量总数Ng设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)沿程水头损失累计hy120.750.15150.882.001.402.80231.500.30200.931.531.071.64342.250.45250.850.931.351.26452.751.60500.750.300.270.08563.251.64500.770.321.480.48678.801.99500.930.461.070.49788.801.99500.930.463.501.598917.602.36501.110.613.502.1491026.402.64501.280.804.003.20101135.202.88501.370.923.202.94111235.202.88501.370.921.671.5418.16选择LXS-50旋翼式水表,其过载流量/h,性能系数为。 则水表的水头损失 所以建筑内WL-2给水系统所需水压为本设计所在地区市政给水压力为0.30 ,所以四根低区由市政管网直接供水的给水管都符合要求。(2)高区给水管道水力计算高区给水为设贮水池、变频调速水泵给水系统,由设计图纸可知GJL-3为最不利配水立管。现对GJL-3进行水力计算 图5 GJL-3水力计算图 表6 给水管网水力计算(GJL-3 5-10层) a=1.5计算管段编号当量总数Ng设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)沿程水头损失累计hy120.800.17151.002.606.1916.09231.550.32250.600.620.700.43342.300.45250.850.932.051.91453.301.64500.770.320.900.29续表564.301.72500.810.354.341.50676.801.88500.880.413.501.447815.352.28501.080.593.502.068923.902.57501.200.733.502.5591032.452.81501.330.873.503.05101141.003.02501.421.003.503.50111249.553.21700.910.3114.204.40121349.553.21700.910.3148.1014.91131490.356.23801.280.4621.329.721415193.2012.731001.480.433.071.3263.17所以: 所以建筑内GJL-3给水系统所需水压为同理对GJL-1、GJL-2、GJL-4进行水力计算计算见下表:表7 给水管网水力计算(GJL-1 5-10层) a=1.5计算管段编号当量总数Ng设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)沿程水头损失累计hy120.750.15150.882.000.701.40231.500.30200.931.531.101.69342.000.40250.750.750.900.67452.500.47250.891.021.161.19566.801.88500.880.413.501.446713.602.21501.040.553.501.937820.402.45501.170.663.502.318927.202.66501.250.773.502.7091034.002.85501.340.903.503.15101140.803.02501.421.0114.2014.3430.80表8 给水管网水力计算(GJL-2 5-10层) a=1.5计算管段编号当量总数Ng设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)沿程水头损失累计hy120.750.15150.882.000.701.40231.500.30200.931.531.482.26342.001.50500.710.270.900.24452.501.57500.720.284.461.25568.051.95500.920.442.661.17678.051.95500.920.443.501.547816.102.30501.090.603.502.108924.902.60501.220.753.502.6291033.702.84501.350.903.503.15101141.753.04501.421.003.503.50111250.553.23501.531.1714.2016.6135.84表9 给水管网水力计算(GJL-4 5-10层) a=1.5计算管段编号当量总数Ng设计秒流量(L/s)管径DN(mm)流速v(m/s)每米管长水头损失i(kPa/m)管段长度L(m)管段沿程水头损失hy=iL(kPa)沿程水头损失累计hy120.750.15150.882.001.092.17231.250.25200.781.091.281.40341.750.35250.660.5916.539.694517.852.37501.110.623.502.175626.652.65501.250.753.502.646735.452.89501.360.933.503.267843.503.08501.431.003.503.508952.303.27700.930.3214.204.5429.37所以,高区供水所需要的水压为479.52,流量为12.73。据此选水泵IS80-50-200两台,一用一备。 3.2 排水系统3.2.1 计算公式及参数建筑内部排水定额有两个,一个是以每人每日为标准,另一个是以卫生器具为标准。每人每日排放的污水量和时变化系数与气候、建筑物内卫生设备完善程度有关。因建筑内部给水量散失较少,所以生活排水定额和时变化系数与生活给水相同。生活排水平均时排水量和最大时排水量的计算方法与建筑内部的生活给水量计算方法相同,计算结果主要用来设计污水泵、化粪池等。卫生器具排水定额是经过实测得来的。主要用来计算建筑内部各管段的排水设计秒流量,进而确定各管段的管径。某管段的设计秒流量与其接纳的卫生器具类型、数量及使用频率有关。为了便于累加计算,与建筑内部给水一样,以污水盆排水量0.33L/s为一个排水当量,将其它卫生器具的排水量与0.33L/s的比值,作为该种卫生器具的排水当量。由于卫生器具排水具有突然、迅速、流率大的特点,所以,一个排水当量的排水流量是一个给水当量额定流量的1.65倍。建筑内部排水管道的设计流量是确定各管段管径的依据,因此,排水设计流量的确定应符合建筑内部排水规律。建筑内部排水流量与卫生器具的排水特点和同时排水的卫生器具数量有关,具有历时短、瞬时流量大、两次排水时间间隔长的特点。建筑内部每昼夜、每小时的排水量是不均匀的。与给水相同,为保证最不利时刻的最大排水量能迅速、安全排放,排水设计秒流量应为建筑内部的最大排水瞬时流量,又称设计秒流量。目前,我国生活排水设计秒流量计算公式与给水相对应,按排水特点有两个:1、集体宿舍、旅馆、医院、幼儿园、办公楼和学校等建筑用水设备使用不集中,用水时间长,同时排水百分数随卫生器具数量增加而减少,其设计秒流量按公式计算为: (式7)式中:qu计算管段排水设计秒流量L/s;Np计算管段上排水量最大的一个卫生器具的排水量L/s;根据建筑物用途而定的系数; qmax管段上排水量最大的一个卫生器具的排水量L/s。用上式计算排水管网起端的管段时,因连接的卫生器具较少,计算结果有时会大于该管段上所有卫生器具排水流量的总和,这时应按该管段所有卫生器具排水流量的累加值作为设计秒流量。2,业生活间、公共浴室、洗衣房、公共食堂、实验室、影剧院、体育场等建筑的卫生设备使用集中,排水时间集中,同时排水百分数高,其排水设计秒流量按公式为: (式8)式中:qu计算管段排水设计秒流量L/s; qp同类型的一个卫生器具排水流量L/s; n0同类型卫生器具数;b卫生器具同时排水百分数。本设计是办公楼,属于第一种情况,所用的公式为(式7)。对于有大便器接入的排水管网起端,因为卫生器具较少,大便器的同时排水百分数定的较小,按公式计算的排水设计秒流量可能会小于一个大便器的排水量,这时应按一个大便器的排水量作为该管段的设计秒流量。为保证管道系统有良好的水力条件,稳定管内气压,防止水封破坏,保证良好的室内环境卫生,在横干管和横支管的设计计算中,建筑内部排水管按非满流计算,以便使污废水释放出的有毒有害气体能自由排出;调节排水管道系统内的压力;接纳意外的高峰流量。管道设计坡度与污废水性质、管径和管材有关。污废水中含有污染物越多,管道坡度应越大。建筑内部生活排水管道的坡度有通用坡度和最小坡度两种。通用坡度为正常条件下应予以保证的坡度;最小坡度为必须保证的坡度,一般情况下应采用通用坡度。当横管过长或建筑空间受限时,可采用最小坡度。表10 塑料排水管坡度管径(mm)通用坡度最小坡度500.0260.012750.0260.0071100.0260.0041600.0260.003为了排水通畅,防止管道堵塞,保障室内环境卫生,规定了室内排水管道的最小管径为50mm。医院、厨房、浴室、以及大便器排放的污水水质特殊,其最小管径应大于50mm。公共食堂厨房排水中含有大量油脂和泥砂,为防止堵塞,实际选用管径应比计算管径大一号,且支管管径不小于75mm,干管管径不小于100mm。医院污物洗涤间内洗涤盆和污水盆内往往有一些棉花球、纱布、玻璃瓶、塑料瓶等杂物落入,为防止管道堵塞,管径不小于75mm。大便器没有十字栏栅,同时排水量大且猛,所以,凡连接大便器的支管,即使仅有一个大便器,其最上管径均为100mm。小便斗和小便槽冲洗不及时,尿垢聚积,堵塞管道,因此小便槽的连接3个及3个以上小便器的排水支管管径不小于75mm。建筑内部排水横管按非满流设计,以便使污水释放出的气体能自由流动排入大气,调节排水管道系统内的压力,接纳意外的高峰流量。建筑内部的最大设计充满度如下表:表11 排水横管最大设计充满度排水管道类型管径(mm)最大设计充满度生活排水管道1250.51502000.6生产废水管道50750.61001500.72001生产污水管道50750.610015000.72000.83.2.2 排水管网水力计算本设计横管选用塑料管,故其标准坡度为0.026。(1)WL-1水力计算 1)横管水力计算图6 WL-1水力计算图表12 排水横管水力计算(WL-1) a=2.5管段编号排水当量Np设计秒流量(L/s)管径De(mm)坡度i120.750.25500.026231.500.50500.026343.000.77750.026454.000.93750.026564.600.97750.0266713.602.611100.0267822.602.931100.026 2)立管水力计算 立管采用仅设伸顶通气管,普通排水塑料管。 立管接纳的排水当量总数为 立管最下部管段排水设计秒流量 查表选用立管管径为。立管底部和排出管放大一号管径,取,取标准坡度,符合要求。 (2)WL-2水力计算1)横管水力计算 图7 WL-2水力计算图表13 排水横管水力计算(WL-2) a=2.5管段编号排水当量Np设计秒流量(L/s)管径De(mm)坡度i120.750.25500.026231.750.58500.026342.500.80750.026453.250.87750.026568.052.351100.0266712.852.581100.0267813.152.591100.026 2)立管水力计算 立管采用仅设伸顶通气管,普通排水塑料管。 立管接纳的排水当量总数为 立管最下部管段排水设计秒流量 查表选用立管管径为。立管底部和
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 高考物理总复习专题十电磁感应第2讲法拉第电磁感应定律、自感、涡流练习含答案
- 广东省阳东广雅学校高二信息技术 三维动画制作教案
- 2024年学年七年级语文下册 第二单元 告别抒怀 第4课《告别昨天的我》教案2 新疆教育版
- 2024-2025学年高中化学 第3章 第2节 课时3 铁的重要化合物教案 新人教版必修1
- 2024年届九年级历史上册 第5课 为争取“民主”“共和”而战教案2 北师大版
- 2023六年级数学上册 二 比和比例 测量旗杆高度教案 冀教版
- 2023六年级数学下册 三 解决问题的策略第三课时 解决问题的策略(练习课)教案 苏教版
- 文书模板-中医师承关系合同书
- 高考地理一轮复习第十二章环境与发展第一节环境问题与可持续发展课件
- 生活水泵房管理制度
- 《有效备课、上课、听课、评课》读书笔记
- 多吃健脑食物,预防老年痴呆症
- 清洗效果监测方法--ppt课件
- 高压氧舱安装施工方案
- 中药提取车间自动化系统验证
- 老挝10大经济特区
- 模具设计评审表(开发前)
- 市政工程变更流程资料表格附件
- 周围血管和淋巴管疾病(PPT)
- 房地产客户信息登记表
- 小学音乐祖国祖国我们爱你课件ppt课件
评论
0/150
提交评论