电器布线材料

式样活页篇

(续二)

ApplianceWiringMaterial

StylePage

ULSubject758-1-5

上海电缆研究所电线电缆信息中心

目录

1.1001Page1

2.1002Page2

3.1003Page3

4.1015Page4

5.1017Page5

6.1020Page6

7.1021Page7

8.1022Page8

9.1023Page9

10.1024Page10

11.1027Page11

12.1028Page12

13.1029Page13

14.1034Page14

15.1035Page15

16.1038Page16

17.1039Page17

18.1041Page18

19.1042Page19

20.1046Page20

21.1047Page21

22.1050Page22

23.1060Page23

24.1063Page24

25.1069Page25

26.1095Page26

27.1277Page27

28.1230Page28

29.1283Page29

30.1316Page30

31.1389Page31

32.1424Page32

33.1491Page33

34.1839Page34

35.2035Page35

36.2093Page36

37.2225Page37

38.2305Page38

39.2720Page39

40.2727Page40

41.2747Page41

42.2748Page42

43.2749Page43

44.2750Page44

45.3239Page45

46.3343Page46

47.3478Page47

48.3584Page48

49.5107Page49

50.5108Page50

51.5128Page51

52.5134Page52

53.20276Page53

54.20379Page54

55.20798Page55

56.20288Page56

57.20289Page57

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1001Issued:May1,1959

Revised:Feb.17,2004

Style1001Semi-rigidPVCorSRPVCInsulatedWire.

Rating80°C,300Volts.

ConductorNo.33-16AWG,solidorstranded.

InsulationSemi-RigidPVC:9milsminimumaverage,

7milsminimumatanypoint.

CoveringNylon2milminimumatanypointthicknessor

LacqueredBraid.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULPhysicalProperties,unaged.

RepresentativeSparkTest

UL(4)DetailedExamination.

Counter-Check(4)PhysicalProperties

Program(4)HeatShock.

{4}Deformation.

(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

UseInternalWiringwhereprotectedfrommechanicalabuse.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1002Issued:May1,1959

Revised:Oct.19,2300

Style1002PVCInsulated,ShieldedWireandJacketWire.

Rating60°C,600V.

Conductor26-16AWGconsistingofNo.30AWGcopperstranding.

InsulationPVC,Class43-30milsmin.avg;27milsatanypoint.

ShieldingOptional.

JacketPVC,Class43-30milsmin.avg;24milsatanypoint.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULPhysicalProperties,Unaged.

RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)PhysicalProperties.

Program(4)HeatShock.

(4)Deformation.

(4)ColdBend.

(4)HorizontalFlameTest.

MarkingGeneral.

UsePhonographandVolumeControlUse;or

InternalWiringofAppliances.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRINGMATERIAL

Subj.758Section1Page1003Issued:1959-08-13

Revised:2003-03-26

*Style1003PolyethyleneInsulation,aPVCJacketedJacket.

Rating60℃,300Volts.

ConductorNo.26-16AWG,solidorstranded,tinnedorbarecopper.

*InsulationPolyethyleneorFlame-RetardantPolyethylene,30mils

minimumaverage,27milsminimumatanypoint.

ShieldingOptional.

*JacketPVC,15milsminimumaverage,13milsminimumatanypoint.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

*toULTensileStrengthandElongationofInsulationandJacket.

"RepresentativeSparkTest.

UL(4)DetailedExamination.

*Counter-Check(4)PhysicalProperties,InsulationandJacket.

*Program(4)Flexibility.

(4)ColdBend.

(12)HorizontalFlameTest.

MarkingGeneral.

UseInelectronicequipmentwhereexposedtotemperaturenot

exceeding60℃.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1015Issued:1959-05-01

Revised:2003-02-17

Style1015PVCInsulatedWire.

Rating80℃,90℃or105℃;600Vac,750Vde.

Conductor30AWG-2000kcmil.

InsulationPVC

Min.Avg.MinatAnyPoint

SizeMilsMils

30-93027

8,74540

6-26054

1-4/08072

250-500kcmil9586

550-1000kcmil11099

1100-2000kcmil125112

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULPhysicalProperties,unaged,Class43.

RepresentativesparkTest.

UL(4)DetailedExamination.

Counter-Check(4)PhysicalProperties,Class43.

Program(4)HeatShock.

(4)ColdBend.

(4)Deformation.

★(12)HorizontalFlameTest.

MarkingGeneral.

UseInternalWiringofAppliances;orInternalWiringof

Applianceswhereexposedtooilatatemperaturenot

exceeding60deg.Cor80deg.C(whicheveris

applicable).Tagsmayalsoindicatethefollowing:

2t500Vpeak-forelectronicuseonly.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1*Page1017Issued:May1,1959

Revised:March2,2301

Style1017InsulatedWire.

Rating80℃z600volts.

ConductorNo.22-8AWG

Tinnedorbarecopper.

InsulationPVC,45milsminavg.,40milsminatanypoint,Class

43.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation.

RepresentativesparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandelongationofInsulation.

Program(4)HeatShock.

(4)Deformation.

(4)ColdBend.

(4)HorizontalFlameTest.

MarkingGeneral.

UseInternalwiringofApplianceswhereexposedto

oilatatemperaturenotexceeding60℃or80℃,whichever

isapplicable.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1020Issued:

1959-05-01

Revised:2003-03-31

*Style1020PVCInsulatedWire.

Rating80℃z600volts.

Conductor1-4/0AWG

Tinnedorbarecopper.

*InsulationPVC,80milsminimumaverage,72milsminimumatany

point.

CoveringNone.

“StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofinsulation.

♦RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

*Program(4)HeatShock.

*(4)Deformation.

*(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

*UseInternalwiringofapplianceswhereexposedtooilat

temperaturenotexceeding(60°Cor800C,whicheveris

applicable).

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1021Issued:1959-05-31

Revised:2003-03-31

*Style1021PVCInsulatedWire.

Rating80℃z600volts.

Conductor225-530MCM

Tinnedorbarecopper.

♦InsulationPVC,95milsminimumaverage,86milsminimumatany

point.

CoveringNone.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation.

*RepresentativeSparkTest.

ULDetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

♦Program(4)HeatShock.

*(4)Deformation.

*(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

UseInternalwiringofapplianceswhereexposedtooilat

temperaturenotexceeding(60℃or80℃,whicheveris

applicable).

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1022Issued:1959-05-01

Revised:2003-03-31

*Style1022PVCInsulatedWire.

Rating80℃z600volts.

Conductor525-1M,MCM.

Tinnedorbarecopper.

*InsulationPVC,110milsminimumaverage,99milsminimumatany

point.

CoveringNone.

StandardApplianceWiringMaterialUL758.

instructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation.

*RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

♦Program(4)HeatShock.

*(4)Deformation.

*(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

UseInternalwiringofapplianceswhereexposedtooilata

temperaturenotexceeding(60℃or80℃,whicheveris

applicable).

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1023Issued:1959-05-01

Revised:2003-03-31

*Style1023PVCInsulatedWire.

Rating80℃,600volts.

Conductor1.1-2M.MCM.

Tinnedorbarecopper.

*InsulationPVC,125milsminimumaveragethickness,112nils

minimum

atanypoint.

CoveringNone.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofinsulation.

♦RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

*Program(4)HeatShock.

★(4)Deformation.

*(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

*UseInternalwiringofappliancesorinternalwiring

ofapplisnceswhereexposedtotemperaturesnotexceeding

80℃orwhereexposedtooilatatemperaturenotexceeding

(60°Cor80°C,whicheverisapplicable).

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1024Issued:May1,1959

Revised:Jan.8,2002

Style1024InsulatedWire.

Rating90°C,600volts.

ConductorNo.22-8AWG.Solidorstranded

InsulationPVC,45milsmin.avg.,40milsmin.atanypoint.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULPhysicalPropertiesunaged

RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)PhysicalProperties.

Program(4)HorizontalFlameTest

(4)HeatShock

(4)Deformation.

(4)ColdBend.

MarkingGeneral.

UseInternalWiring

AdditionMarking

1.OilResistance600or80°C(ifapplicable)

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1027Issued:1959-05-01

Revised:2003-03-31

*Style1027PVCInsulatedWire.

Rating90°C,600volts.

Conductor1-4/0AWG.

Tinnedorbarecopper.

*Insulation80milsminimumaverage,72milsminimumatanypoint.

CoveringNone.

StandardApplianceWiringMaterialUL758.

instructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation.

*RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

“Program(4)HeatShock.

*(4)Deformation.

*(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

*UseInternalwiringofappliancesorinternalwiringof

applianceswhereexposedtotemperaturesnotexceeding

90℃orexposedtooilataterr.peraturenotexceeding

(60°Cor80°C,whicheverisapplicable).

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1028Issued:1959-05-01

Revised:2004-04-23

Style1028Thermoplastic(PVC)-InsulatedWireforAppliance

Hook-UpUse.

Rating105℃z600volts.

ConductorNo.22-6AWG,tinnedorbarecopper.

InsulationClass43,PVC,No.22-8AWGminimumaveragethickness

45mils,minimumthicknessatanypoint40mils;

No.7-6AWGminimumaveragethickness60mils,minimum

atanypoint54mils.

CoveringNone.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation.

RepresentativeSparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

Program(4)HeatShock.

(4)Deformation.

(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

UseInternalwiringofapplianceswhereexposedto

temperaturesnotexceeding105℃;orinternalwiring

ofapplianceswhereexposedtotemperaturesnot

exceeding105°C,orwhereexposedtooilatatemperature

notexceeding(60℃or80℃,whicheverisapplicable.)

Tagsmayindicatethefollowing:2500VoltsPeak-

ForElectronicUseOnly.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1029Issued:1959-05-01

Revised:2003-03-31

*Style1029PVCInsulatedWire.

Rating105°C,600volts.

ConductorNo.8-6AWG.

Tinnedorbarecopper.

*InsulationPVC,45milsminimumaveragethickness,40nils

minimumat

anypoint.

CoveringExtrudednylonin2-milminimumthicknessor

lacqueredbraid.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation.

RepresentativesparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

Program(4)HeatShock.

(4)Deformation.

(4)ColdBend.

(12)HorizontalFlameTest.

MarkingGeneral.

*UseInternalwiringofappliancesorinternalwiringof

applianceswhereexposedtotemperaturesnotexceeding105℃

orwhereexposedtooilatatemperaturenotexceeding

(60℃or80℃zwhicheverisapplicable).

Tagsmayindicatethefollowing:2500VoltsPeak-

ForElectronicUseOnly.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1034Issued:1959-05-01

Revised:2003-03-31

*Style1034PEInsulatedWire.

Rating80℃z300Volts.

ConductorNo.22-18AWG,solidorstrandedwire.

No.30AWG,copperstranding,tinnedorbare.

"InsulationPolyethylene,15milsminimumaveragethickness,13

mils

minimumatanypoint.

ShieldingOptional.

*JacketPVC,30milsminimumaveragethickness,24milsminimumat

anypoint.

StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofInsulationand

Jacket.

*RepresentativeSparkTest.

UL(4)DetailedExamination.

*Counter-Check(4)PhysicalProperties,Jacket.

*Program(4)HeatShock,Jacketonly.

*(4)Deformation,Jacketonly.

*(4)ColdBend.

*(12)HorizontalFlameTest.

MarkingGeneral.

UsePhonographandvolumecontrolusewhereinsulationis

exposedtoatemperaturenotexceeding60℃andthejacket

isexposedtoatemperaturenotexceeding800C.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1035Issued:May1,1959

Revised:Oct.23,2000

*Style1035Thermoplastic(Polyethylene)Insulated,Shielded,

andPVCJacketedWire.

Rating80℃,600Volts.

ConductorNo.22-18AWG.SolidorstrandedwithNo.30AWG.

*copperstranding,tinnedorbare.

InsulationNominal1/32-InchwallcfPolyethylene.

*ShieldingOptional.

JacketOvershieldinganominal1/32-ZnchThermoplastic

(PVC)jacketshallbeapplied.Thejacketshallbe

acompoundsuitableforuseat800C.

.StandardApplianceWiringMaterialUL758.

instructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation

“RepresentativeandJacket,sameasforClass43.

*SparkTest,3000Volts.

UL(4)DetailedExamination.

.Counter-Check(4)Jacket,Class43,exceptforaging.

“Program(4)HeatShock,Class43,Jacketonly.

*(4)ColdBend,Class43,butatminus10°C.

*(4)HorizontalFlameTest.

(4)Deformation,Class43,Jacketonly.

"MarkingGeneral.

UsePhonographandVolumeControlUsewhere

Insulationisexposedtoatemperature

notexceeding60℃andthejacketisexposed

toatemperaturenotexceeding800C.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1038Issued:May1,1959

Revised:Oct.23,2300

Style1038Nominal12-MilThermoplastic(PVC)-Insulated

WireForBusinessMachinesUse.

Rating60°C,300Volts.

ConductorNo.24-20AWG.having7strandstinnedorbare

*copper.

InsulationNominal12-MilwallThermoplastic(PVC),9.5-Mil

minimumatanypoint.

*CoveringLacqueredbraid.

.StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongtionofInsulation,

*RepresentativesameasforClass43.

*SparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation,

Programafteraging,sameasClass43.

★(4)HeatShock.

*(4)Deformation.

*(4)ColdBend.

*(4)HorizontalFlameTest.

★(4)DielectricStrengthTest.

"MarkingGeneral.

UseInternalWiringinelectricbookkeeping,

accounting,ortime-recordingmachineswhere

exposedtotemperaturesnotexceeding60°C.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1039Issued:May1,1959

Revised:Oct.23,2000

Style1039Nominal15-MilThermoplastic(PVC)-Insulated

WireForBusinessMachineUse.

Rating80℃z300Volts.

ConductorNo.26-16AWG.having7strandstinnedorbare

copper.

InsulationNominal15-MilwallThermoplastic(PVC)-12-Mil

minimumatanypoint.

CoveringNone.

“StandardApplianceWiringMaterialUL758.

InstructionsDetailedExamination.

toULTensileStrengthandElongationofInsulation,

"RepresentativesameasforClass43.

sparkTest.

UL(4)DetailedExamination.

Counter-Check(4)TensileStrengthandElongationofInsulation.

Program★

*(4)HeatShock.

★(4)Deformation.

★(4)ColdBend.

*(4)HorizontalFlameTest.

*(4)DielectricStrengthTest.

“MarkingGeneral.

UseInternalWiringinelectricbookkeeping,

accounting,ortime-recordingmachineswhere

exposedtotemperaturesnotexceeding800C.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1041Issued:May1,1959

Revised:Oct.23,2300

Style1041Nominal1/32-InchThermoplastic(PVC)-Insulated

WireFor

InternalWiringofElectricRefrigeratingEquipment.

Rating60°C,300Volts.

ConductorNo.20-16AWG.No.20AWG.shallbesolidorstranded.

No.18-16AWG.shallbestranded.Allstrandedconductors

shallconsistofNo.30AWG.orsmallerstrands.All

*conductorsshallbetinnedorbarecopper.

InsulationNominal1/32-InchwallThermoplastic(PVC),Class

43.

CoveringNone.

“StandardApplianceWiringMaterialUL758.

InstructionsSameasforTypeTFwireexceptinsulationresistance

shall

toULbenotlessthan1megohm-1000feet.

Representative

UL(4)SameasforTypeTFWire.

Counter-Check

Program

.MarkingGeneral.

UseInternalWiringofLightingCircuitsinRefrigerating

Equipment.

UNDERWRITERSLABORATORIESINC.APPLIANCEWIRING

MATERIAL

Subj.758Section1Page1042Issued:May1,1959

Revised:June24z2302

Style1042Nominal1/32-InchThermcplastic(PVC)-Insulated

WireForInternalWiringofElectricRefrigerating

Equipment.

Rating60℃,300Volts.

ConductorNo.23-16AWG.No.20AWG.shallbesolidor

stranded.No.18-16AWG.shallbestranded.All

strandedconductorsshallconsistofNo.30AWG.

orsmallerstrands.Allconductorsshallbetinned

orbarecopper.

InsulationNominal1/32-InchwallThermoplastic(PVC),Class

43.

"CoveringExtrudednylonin2-milminimumthickness.

StandardApplianceWiringMaterialUL758.

*InstructionsSameasforTypeTFwire.

toUL

Representative

UL(4)SameasforTypeTFWire.

*Counter-Check.(12)HorizontalFlameTest.

Program

MarkingGeneral.

Use

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

最新文档

评论

0/150

提交评论