《HighVoltageEquipmentTesting》InsulatingOilDielectricStrengthTest主讲人:何发武(副教授)OperatingWorksheet:OperatingWorksheet:TableofContents01Followme02Workshop03Training01FollowmeⅠ.PrincipleofDielectricStrengthTestingforInsulatingOilDielectricstrengthtestingforinsulatingoilisacommonlyusedmethodtoassesstheinsulationperformanceoftheoil,anditisanimportantmeanstoevaluatetheinsulationpropertyofinsulatingoilasatypeofinsulationmaterial.Theinsulationperformanceofinsulatingoiliscrucialforthesafeoperationofelectricalequipment.Thedielectricstrengthtestforinsulatingoildeterminesitsabilitytowithstandvoltageunderhighelectricfields,therebydeterminingitssuitabilityforuseinhigh-voltageequipment.Ⅰ.PrincipleofDielectricStrengthTestingforInsulatingOilTheprincipleofdielectricstrengthtestingforinsulatingoilismainlybasedontheeffectofanelectricfield.Duringthetest,ahighvoltageisappliedtotheinsulatingoiltogenerateastrongelectricfield.Theinsulationperformanceoftheinsulatingoildeterminesitsabilitytowithstandvoltageunderanelectricfield,knownasthedielectricstrength.Duringthetest,twoelectrodesareinsertedintotheinsulatingoil,servingaspositiveandnegativeelectrodesrespectively,andahighvoltageisapplied.Theelectricfieldformedbetweentheelectrodeswillconductabreakdowntestontheinsulatingoiltoevaluateitsinsulationcapability.Ⅰ.PrincipleofDielectricStrengthTestingforInsulatingOilThereareseveralkeypointstonoteduringtheprocessofdielectricstrengthtestingforinsulatingoil.First,itisimportanttoensuregoodcontactbetweentheelectrodesandtheinsulatingoil,andthedistancebetweentheelectrodesshouldmeetthetestingrequirements.Second,itisimportanttoensuretheuniformdistributionoftheelectricfieldbetweentheelectrodesandtheinsulatingoil,toavoidlocalizedhighelectricfieldintensity.Additionally,theeffectoftemperatureshouldbeconsideredduringthetest,asthereisacertainrelationshipbetweenthedielectricstrengthoftheinsulatingoilandtemperature.Figure3-40showsanautomaticinsulatingoildielectricstrengthtester.Ⅰ.PrincipleofDielectricStrengthTestingforInsulatingOilFigure3-40
Automaticinsulatingoildielectricstrengthtester1–LCD;2–Functionkeys;3–Printer;4–Boostingrateswitch;5–Indicatorlight;6–Oilcupcompartmentcover;7–Temperatureandhumiditysensors;8–Groundlinecolumn;9–Powersocket;10–Powerswitch;11–Highvoltagesafetysign.Ⅱ.OverviewofInsulatingOilInsulatingoiliswidelyusedinhigh-voltageelectricalequipmentsuchastransformers,instrumenttransformers,switchgear,oil-filledcables,powercapacitors,andbushings.Duringoperation,theperformanceofinsulatingoilgraduallydeterioratesduetotheeffectsofoxygen,hightemperature,highhumidity,sunlight,strongelectricfields,andimpurities,whichpreventitfromfullyfunctioningasaninsulator.Ⅱ.OverviewofInsulatingOilInordertoconfirmwhethertheinsulationperformanceofinsulatingoilmeetstherequirements,regulartestsonitsrelevantpropertiesmustbeconducted.AccordingtothenationalstandardGB507–2002“MethodforTestingDielectricStrengthofInsulatingOil,”thedielectricstrengthofinsulatingoilreferstothebreakdownvoltage,breakdownstrength,andvoltagewithstandcapabilityoftheoil.Itisanimportantqualityindicatorthatrepresentstheabilityofinsulatingoiltowithstandvoltage.Thedielectricstrengthtestgraduallyincreasesthevoltageappliedtotheinsulatingoilunderspecifiedtestconditionsuntilitbreaksdownandlosesitsinsulationproperties.Itisexpressedastheaveragebreakdownvoltagedividedbytheelectrodedistance(kV/cm).Ahigherdielectricstrengthindicatesbetterinsulationperformance.Ⅱ.OverviewofInsulatingOilTransformeroilisafractionaldistillationproductofpetroleum,mainlycomposedofcompoundssuchasalkanes,cycloalkanes,saturatedhydrocarbons,andaromaticunsaturatedhydrocarbons.Itisamixtureofliquidnaturalhydrocarbonsobtainedfromthelubricatingoilfractioninpetroleumthroughacid-baserefining,whichispure,stable,haslowviscosity,goodinsulation,andcoolingproperties.Itisalightandyellowtransparentliquidwitharelativedensityof0.895andafreezingpointbelow-45C.Transformeroilservesasaninsulatingandcoolinglubricatingmediumintheoil-immersedtransformer.Theservicelifeoftransformeroilcanusuallyreach10–15years.Ⅱ.OverviewofInsulatingOil(Ⅰ)Requirementsforinsulatingoil(1)Itshouldhaveahighdielectricstrengthtoadapttodifferentoperatingvoltages.(2)Itshouldhavealowviscositytomeettheneedsofcirculationconvectionandheattransfer.(3)Itshouldhaveahighflashpointtemperaturetomeetfiresafetyrequirements.(4)Itshouldhavesufficientlow-temperatureperformancetowithstandpotentiallow-temperatureenvironments,andgoodoxidationresistancetoensurealongservicelifeoftheoil.Ⅱ.OverviewofInsulatingOil(Ⅱ)Electrical,physicalandchemicalpropertiesoftransformeroilJudgingthequalityofoilfromitsappearance,thecolorofnewoilisgenerallylightandyellow,butitturnsdarkredafteroxidation.Ifthecolorofoilbecomesdarkquicklyduringoperation,itindicatesthattheoilqualityhasdeteriorated.Normaltransformeroiliscolorlessandodorless.Ifthereisadifferentodor,itmeansthattheoilqualityhasdeteriorated(asshowninFigure3-41).Forexample,aburntsmellindicatesthattheoilhasoverheatedwhenitdriesout,anacidicsmellindicatesthattheoilhasseriouslyaged,andanacetylenesmellindicatesthatarcinghasoccurredwithintheoil.Newoilhasgoodtransparencyandistransparentinaglassbottlewithblue-violetfluorescence.Ifitlosesitsfluorescenceandtransparency,itindicatesthepresenceofwater,mechanicalimpurities,andfreecarbon.Ⅱ.OverviewofInsulatingOilFigure3-41
TransformeroilsamplesⅡ.OverviewofInsulatingOil(Ⅲ)Electrical,Physical,andChemicalPropertiesTestingofTransformerOilThebreakdownvoltageoftransformeroiliscloselyrelatedtothecleanlinessofnewoilandthedeteriorationconditionofoperatingoil.Theelectrical,physical,andchemicalpropertiestestingoftransformeroilareshowninTable3-22.Ⅱ.OverviewofInsulatingOilTable3-22
Electrical,Physical,andChemicalPropertiesTestingofTransformerOilⅡ.OverviewofInsulatingOilTable3-22
Electrical,Physical,andChemicalPropertiesTestingofTransformerOilⅢ.PerformanceofTransformerOilTransformeroilservesasamediumwithinelectricalequipmentandmustpossessgoodelectricalperformanceinordertofullyfunctionasinsulationandcooling.Themainelectricalperformancesofnewoilincludeinsulationstrengthanddielectricdissipationfactor.Ⅲ.PerformanceofTransformerOil(Ⅰ)InsulationStrengthInsulationstrengthreferstothedielectricstrengthorbreakdownvoltageoftransformeroil.Itmeasurestheabilityoftheoiltowithstandvoltagewithinelectricalequipmentwithoutbeingdamaged.Thisisoneofthemainmethodstoassessthequalityoftransformeroil.Thebreakdownprocessofinsulatingoilisrelatedtoitspurity.Pureinsulatingoilhashighbreakdownstrength(upto106
kV/cm),anditsbreakdownprocessismainlycausedbyelectricalbreakdown.Theoilinequipmentoftencontainsvariousimpurities,suchasgases,moisture,solidparticles,andpolymersgeneratedfromoilaging.Ⅲ.PerformanceofTransformerOil(Ⅱ)DielectriclossfactorThedielectriclossfactorprimarilyreflectsthepowerlosscausedbyleakagecurrentintheoil.Themagnitudeofthedielectriclossfactorissensitiveindeterminingthedegreeofdegradationandcontaminationoftransformeroil.Thedielectriclossfactorcanonlyindicatewhethertheoilcontainspollutantsandpolarimpurities,butitcannotdeterminethespecifictypeofimpuritiespresentintheoil.However,whentheoildeterioratesduetooxidationoroverheating,orwhenitismixedwithotherimpurities,thedielectriclossfactorincreasesasthecontentofimpuritiesorcolloidalsubstanceschargedintheoilincreases,evenuptomorethan10%.Ⅲ.PerformanceofTransformerOilDielectriclosstestsaremainlyusedtodeterminewhethertheoilisdirtyordegraded.Theycanonlydeterminethepresenceofpolarsubstancesintheoil,butnotthespecifictypeofpolarsubstances.Inthecaseoffurtheroxidation,theoil’sabilitytodissolvewatermayincrease,andthereforethepresenceofsludgeinthistypeofoilmaynotbereflectedinthedielectriclossfactor.Ifthedielectriclossexceeds0.7%,aninspectionisrequired.Ifthedielectriclossat100Cis7–10timeshigherthanthatat25C,itindicatesthattheoilisdirtyratherthancontainingmoisture.Ⅲ.PerformanceofTransformerOil(Ⅲ)PhysicalandChemicalPropertyTests(1)AppearanceandColorofOilGoodoilshouldbecleanandtransparent.Ifitisunclear,itmaycontainwater,carbonparticles,orsludge.Ifcarbonparticlesarefound,theremaybearcingorpartialdischargephenomenainsidethetransformer,anditisnecessarytoperformchromatographicanalysisontheoil.Ifthereisasignificantchangeinthecoloroftheoil,payattentiontowhethertheoilisagingacceleratedorthemonitoringoftheoperatingtemperatureoftheoil.Ⅲ.PerformanceofTransformerOil(2)AcidvalueAcidvaluereferstotheacidiccomponentscontainedin1goftestoil,expressedasmgKOH/g.Itisanimportantindicatorfortestingtransformeroilandreflectsthedegreeofoilrefinementandoxidation.Theincreaseinacidvalueisasignofinitialoildeterioration,andthepresenceofacidicsubstanceswillinevitablygeneratesludge.Ifthereismoistureintheoil,itcancauserustingofmetalssuchasironandalsodamagepaperinsulation.Ⅲ.PerformanceofTransformerOil(3)InterfacialtensiontestTheinterfacialtensiontestisquitesensitivetodegradationproductsintheoilandsolubleimpuritiesgeneratedfromsolidinsulationmaterials.Thegreaterthecontentofoxidationproductsintheoil,thelowertheinterfacialtension.Iftheinterfacialtensionvalueintheoilisbetween27–30mN/m,itindicatesatendencyforsludgeformation.Ifthetensionvaluedrops8mN/m,itindicatessevereoilagingandshouldbereplaced.Ⅲ.PerformanceofTransformerOil(4)MoistureContentMoistureintheoilandinsulationpaperreachesanequilibriumstate.Theoilhasdifferentsaturationlevelsofdissolvedmoistureatdifferenttemperatures.Thissaturationlevelincreaseswithtemperature,somoisturefromtheinsulationpaperenterstheoilathightemperatures.Whentheoiltemperaturedrops,someofthemoistureintheoilwilldiffuseintothepaper,causingadecreaseinthewatercontentintheoil.Ⅲ.PerformanceofTransformerOil(5)FlashpointTheflashpointisthelowesttemperatureatwhichthevaporofanoilmixturewithairwillignitemomentarilyuponcontactwithaflame,underspecifiedconditionsoftemperature,time,andflamesize.Thevolatilityoftheoilproductisactuallyrelatedtothesafetyoftransformeroilintheconditionsofuseandcanbemeasuredbytheflashpoint.Ⅲ.PerformanceofTransformerOilTheflashpointandignitionpointarenotequivalentconcepts.Theflashpointreferstothelowesttemperatureatwhichtheoilgasproducedissufficientandwhenanexternalflameisadded,theoilgasignitesmomentarily;theignitionpointisthelowesttemperatureatwhichanexternalflamecanbemaintainedfor5secondswhentheoilgascontinuouslyproducedbyheating.Thesampleisheatedataslowandconstantrateundercontinuousstirring.Atpredeterminedtemperatureintervals,asmallflameisintroducedintothecupwhilestirringisinterrupted.Theminimumtemperatureatwhichtheflamecausesthevaporonthespecimentoflashfireiscalledtheclosedflashpoint.Ⅲ.PerformanceofTransformerOil(6)Water-solubleacidWater-solubleacidreferstowater-solublemineralacids,primarilysulfuricacidanditsderivatives,thatareformedduringtheprocessingandstorageofoilproducts.Transformeroilgenerallyproduceslowmolecularweightorganicacids,suchasformicacidandaceticacid,duringtheprimaryoxidationstage.Theseacidshavegoodwatersolubility.Whenthewater-solubleacidcontentintheoilincreases(i.e.,thepHvaluedecreases)andthereiswaterpresentintheoil,itcancorrodesolidinsulationmaterialsandmetals,reducetheinsulationperformanceofelectricalequipment,andshortentheservicelifeoftheequipment.Shakethetestoilandanequalvolumeofdistilledwatervigorouslytomixthem.Extractthewaterphasefromthemixtureandaddanindicator.Observeanycolorchangestodeterminethepresenceofwater-solubleacidsandwater-solublealkalisinthetestoil.TheresultsarerepresentedbythepHvalue.Ⅳ.JudgmentstandardofoilqualityTable3-23
GB/T7595–2017
QualityStandardforIn-serviceTransformerOilⅣ.Judgmentstandardofoilquality02WorkshopⅠ.InsulatingOilDielectricStrengthTestStepsandPrecautionsWhenconductingadielectricstrengthtestoninsulatingoilusinganinsulatingoilwithstandvoltagetester,thefollowingprocedureshouldbefollowed:(1)Groundtheinstrumentreliably.(2)Whenthepowerisoff,placethemagnetometerintheoilcup.(3)The“sampleoil”mustbeplacedinthelaboratoryforaperiodoftimewithoutdamagingtheoriginalstorageseal,untiltheoiltemperatureisclosetoroomtemperaturebeforeuncoveringforthetest.Beforeuncovering,gentlyshakethetestoiltoevenlydistributeimpurities,butdonotproducebubbles.Beforethetest,washtheoilcup2–3timeswiththetestoil.Ⅰ.InsulatingOilDielectricStrengthTestStepsandPrecautions(4)Whenthesampleoilisloadedintotheoilcupinapower-offstate,itshouldflowdownslowlyalongtheinnerwalloftheoilcuptoreducebubbles.Duringoperation,itisnotallowedtotouchtheelectrodes,theinsideoftheoilcup,andthetestoilwithhands.Aftertheoilcupisfilledwithtestoil,itmustbeleftstillfor10–15minutesbeforestartingthebreakdowntest.(5)Inapower-offstate,covertheelectrodecoverandclosethehigh-voltagechamberlid.(6)Turnonthepowerswitch,andaftertheinstrumentdisplaysthewelcomescreen,itautomaticallyentersthemaininterface.(7)Usingthemouse,selectoperationssuchasbreakdowntest,withstandvoltagetest,viewhistoricaldata,timesetting,andPCcommunication.Ⅱ.Dielectricstrengthtestmethodforinsulatingoil(Ⅰ)Operationmethodforbreakdowntest(1)Setthetestparameters,includinginitialsettlingtime,numberoftests,settlingtime,stirringtime,andoilcupselection,asshowninFigure3-42.Therangefortheinitialsettlingtimeis0secondsto9minutesand59seconds,therangeforsettlingtimeis0secondsto9minutesand59seconds,andtherangeforstirringtimeis0secondsto99seconds.Thestatusofthethreeoilcupscanbeeither“selected”or“notselected”.Ⅱ.DielectricstrengthtestmethodforinsulatingoilFigure3-42
TestinstrumentparametersettinginterfaceⅡ.Dielectricstrengthtestmethodforinsulatingoil①Settlingtime:defaultvalueis15minutes,rangeis1to15minutes(increment=1minute).②Intervaltime:defaultvalueis5minutes,rangeis1to10minutes(increment=1minute).③Stirringtime:defaultvalueis10seconds,rangeis5to90seconds(increment=5seconds).④Stopvoltage:defaultvalueis80
kV,rangeis10to80
kV(increment=10
kV).Whentheinstrumentreachesthe“stopvoltage”,itwillstopincreasingvoltageandentertheholdstate.Ifnobreakdownoccursfor50seconds,theinstrumentwilldefaultthecurrentstopvoltageasthedielectricbreakdownvoltageoftheinsulatingoil.Ⅱ.Dielectricstrengthtestmethodforinsulatingoil⑤Numberofpressurecycles:defaultvalueis6times,optionalrangeis1to6times(increment=1time).Aftersetting,pressthe“confirm”buttontoreturntothestartpage,andpressthe“start”buttontobegintesting.(2)Select“starttest”andclick“run”tostartthetest.Theinstrumentwillcyclethroughthesequenceofincreasingvoltageuntilbreakdown,stirring,settling,andthenincreasingvoltageuntilbreakdownagainuntilthesetnumberoftestsisreachedandtheteststops.(3)Afterthebreakdowntestiscompleted,thedisplayscreenoftheinstrumentshowsthetestresults,includingbreakdownvoltageandaveragebreakdownvoltage,asshowninFigure3-43.(4)Theoperatorcanalsosaveandprintthetestresultsasneeded.Ⅱ.Dielectricstrengthtestmethodforinsulatingoil(Ⅱ)Theoperatingmethodofthewithstandvoltagetestisasfollows(1)Setthetestparameters,includingvoltage,withstandtime,andoilcupselection.(2)Select“starttest”andclick“run”.Theinstrumentwillincreasevoltageuntilitreachesthesetwithstandvoltage.Ifabreakdownoccursduringthevoltageincreaseprocess,thetestwillenddirectly.Ifnobreakdownoccursduringthevoltageincreaseprocessandtheinstrumentreachesthesetwithstandvoltage,itwillstayatthatvoltageforthedurationofthe“withstandtime”.(3)Afterthewithstandvoltagetestiscompleted,thedisplayedtestresultsincludethewithstandvoltage,withstandtime,andtestresult(OKforpassingorNOforfailing).Ⅱ.Dielectricstrengthtestmethodforinsulatingoil(4)Theoperatorcanalsosaveandprintthetestresultsasneeded.Thedisplayedcontentonthescreenincludesthetotalnumberofsavedtestgroups,theserialnumberofthecurrentlyselectedgroup,andthestoragetime.Theoperationforviewinghistoricaldataisasfollows:Movethecursortothe“confirm”buttontoenterthetestresultviewingscreen.ThetestresultscreenisshowninFigure3-43.Inthesescreens,choosetoprint,saveordeletethedataforthatgroup.Figure3-43
WithstandvoltagetestresultⅢ.InsulationoildielectricstrengthtestprecautionsDielectricstrengthtestingisquitesensitivetoslightcontaminationofthesample,anditiseasyforthesampletoabsorbmoistureduringsampling.Therefore,cleananddrysamplingtoolsshouldbeusedtostrictlyfollowthesamplingmethodforelectricaloilsampling.Thetestoilmustbeplacedinthelaboratoryforaperiodoftimewithoutdamagingtheoriginalstorageandsealingbeforeopeningthecoverfortestingwhentheoiltemperatureisclosetoroomtemperature(thearbitrationtestshouldbeperformedbetween15–20C).Beforeopeningthecover,gentlyshakethetestoiltomiximpuritiesevenly,butdonotproducebubbles.Ⅲ.Insulationoildielectricstrengthtestprecautions1.OilCupCleaningMethod(1)Useacleanclothtorepeatedlywipethesurfaceoftheelectrodeandtheelectroderod.(2)Adjusttheelectrodegapwithastandardgauge.(3)Cleanwithanhydrousethanolfor3–4times,thendrywithahairdryer.Finally,cleanwithatestoilsamplefor2–3times.2.CleaningClean,anduncontaminatedpairoftweezersoramagneticglas
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 【高二政治哲学认识论知识点复习】
- 【语文知识点复习总汇】
- 爱上大我十岁的女生要继续追求吗
- 2025年连续变倍生物显微镜项目投资可行性研究分析报告-20241226-211809
- 2025年连杆项目规划申请报告范稿
- 新课标视域下小学数学教学培养学生自学能力的策略
- 2025年中国经济型轿车行业市场深度分析及投资规划建议报告
- 2025年嘧菌酯项目建议书
- 2024-2026年中国计算机视觉市场发展前景预测及投资战略咨询报告
- 甜品烘焙培训合同范本
- GB/T 2573-2008玻璃纤维增强塑料老化性能试验方法
- GB/T 22560-2008钢铁件的气体氮碳共渗
- GB/T 1265-2003化学试剂溴化钠
- 统编版四年级道德与法治下册全册课件
- 医院评审工作临床科室资料盒目录(15个盒子)
- 社区获得性肺炎临床路径
- 压力性损伤指南解读
- 汤姆走丢了 详细版课件
- 大学学院学生心理危机预防与干预工作预案
- 国有土地上房屋征收与补偿条例 课件
- 铁路建设项目施工企业信用评价办法(铁总建设〔2018〕124号)
评论
0/150
提交评论