PICMG-3-0-Shortform原版完整文件_第1页
PICMG-3-0-Shortform原版完整文件_第2页
PICMG-3-0-Shortform原版完整文件_第3页
PICMG-3-0-Shortform原版完整文件_第4页
PICMG-3-0-Shortform原版完整文件_第5页
已阅读5页,还剩29页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

AdvancedTCATM

PICMG3.0

ShortFormSpecification

January2003

ThisshortformspecificationisderivedfromthePICMG3.0®AdvancedTelecommunicationsComputingArchitecture(ATCA)specificationasapprovedonDecember30,2002bythePICMG®ExecutiveMembership.ForguidelinesonthedesignoftheAdvancedTCA™compliantboardsandsystems,refertothefullspecification–donotusethisshortformforanydesigndecisions.

Copyright2003,PCIIndustrialComputersManufacturersGroup(PICMG)

PICMGdisclaimsallwarrantiesandliabilityfortheuseofthisdocumentandtheinformationcontainedhereinandassumesnoresponsibilityforanyerrorsoromissionsthatmayappearinthisdocument,norisPICMGresponsibleforanyincidentalorconsequentialdamagesresultingfromtheuseofanydatainthisdocument,nordoesPICMGassumeanyresponsibilitytoupdateorcorrectanyinformationinthispublication.

PICMG3.0ShortFormSpecification

Page

PAGE

10

of33

Overview

ThisshortformspecificationisasubsetofthefullAdvancedTCA™basePICMG®3.0specificationdevelopedbyPICMG®.ThisdocumentismeanttoprovidebackgroundinformationforthoseinterestedintheprogressanddirectionoftheAdvancedTCAeffort,butitisnotadesigndocument.Anyonewishingtodesignaboard,backplaneorsystemshouldobtainthefullspecificationsfromPICMG®.APDFversionofthisshortformspecificationcanbedownloadedfromtheAdvancedTCAsectionofthePICMG®

WebSiteat.Notethatthe

fulldocumentcontainsfarmoreinformationandmanysectionsnottoucheduponinthisshortformdocument.

Introductionandobjectives

ThePICMG®(PCIIndustrialComputerManufacturersGroup)3.0specificationdefinesopenarchitecturemodularcomputingcomponentsthatcanbequicklyintegratedtodeployhighperformanceservicessolutions.ThePICMG®

3.0familyofspecificationsdrawsheavilyonthePICMG®2.0experiencebyadoptingtheserialinterconnectphilosophythathasevolvedtherewhilemakingchangeswheretheyareindicatedbythatexperience.

ThePICMG®3.0specificationisfocusedonthedefinitionofanarchitecturethatcan:

Enablereduceddevelopmenttimeandcosts

Supportreducedtotalcostofownership

Applytoedge,core,transport,anddatacenter

Applytowireless,wireline,andopticalnetworkelements

Supportarichmixofprocessors,digitalsignalprocessors(DSPs),networkprocessors(NPs),storage,andinput/output(I/O)

Integratewithmultiplenetworkelements

Providemulti-protocolsupportforinterfacesupto40Gb/s

Offerhighlevelsofmodularityandconfigurability

Improvevolumetricefficiency

Improvepowerdistributionandmanagement

Offeranadvancedsoftwareinfrastructureprovidingoperatingsystems(OSs),applicationprogramminginterface(API),andoperation,administration,management,andprovisioning(OAM&P)

Offerworld-classelementcostandoperationalexpense

Providehighlevelsofserviceavailability(99.999%andgreater)throughtheintegrationoffeaturesforresiliency,redundancy,serviceabilityandmanageability

SupportappropriatescalabilityofSystemperformanceandcapacity

Theobjectiveofthisdocumentistopresentbaserequirements,and,insomecases,suggestimplementationsforthePICMG®3.0Specification.Includedisdetailedinformationofthefollowingelementsthatmustbeconsideredduringdevelopment:

Mechanicals

SystemManagement

PowerDistribution

PowerConnectorZone(forDual-48VDCpowertoeachSlot)

RearI/OAccessZone

DataTransportConnectorZone(forSystemmanagementandswitchingfabricinterconnect)

ShelfThermalDissipation

RegulatoryGuidelines

Allsignalsareactivehighunlessdenotedbyatrailing#symbol.Differentialsignalsaredenotedbyatrailing+(positive)or–(negative)symbol.

Specialtermsandacronyms

Thefollowingtermsandacronymsareusedinspecificwaysthroughoutthisspecification:

Term

Definition

Backplane

ApassivecircuitboardprovidingtheZone1andZone2connectorsforFrontBoardSlots.LinkPortsoftheSlotsareconnectedviahighspeedsignalpairs.Powerdistribution,management,andauxiliarysignalconnectionsaresupported.

ComponentSide1

WhenusedinreferencetoanAdvancedTCA™Board,thesideonwhichthehighestelectroniccomponentswouldbemounted.IdenticalwiththeRightsideasdefinedbelow.

ComponentSide2

WhenusedinreferencetoanAdvancedTCA™Board,thesidenormallyreservedformakingsolderconnectionswiththrough-holecomponentsonComponentSide1butonwhichlowheightelectroniccomponentsmayalsobemounted.IdenticalwiththeLeftsideasdefinedbelow.

DataTransportInterface

Thecollectionofpoint-to-pointinterfacesandbusedsignalsintendedtoprovideinterconnectamongthePayloadsonHubandNodeBoardsinSection6ofthespecification.

Dual-DualStarTopology

Aninterconnectfabrictopologyinwhichfourswitchresourcesprovideredundantconnectionstoallendpointswithinthenetwork.TwopairsofHubBoardsprovideredundantinterconnectsbetweenNodeBoardsviatwoindependentnetworksinparallel.

DualStarTopology

Aninterconnectfabrictopologyinwhichtwoswitchresourcesprovideredundantconnectionstoallendpointswithinthenetwork.ApairofHubBoardsprovideredundantinterconnectsbetweenNodeBoards.

ElectronicKeyingorE-Keying

ProtocolusedtodescribethecompatibilitybetweentheBaseInterface,FabricInterface,UpdateChannelInterface,andSynchronizationClocksconnectionsofFrontBoards.

FabricInterface

AZone2interfacethatprovides15connectionsperBoard/Sloteachcomprisedofupto8differentialsignalpairs(Channel)supportingconnectionswithupto15otherSlots/Boards.BackplanesmaysupporttheFabricInterfaceinavarietyofconfigurationsincludingFullMeshandDualStartopologies.BoardsthatsupporttheFabricInterfacemaybeconfiguredasFabricNodeBoards,FabricHubBoards,orMeshEnabledBoards.BoardimplementationsoftheFabricInterfacearedefinedby

thePICMG®3.xsubsidiaryspecifications.

FieldReplaceableUnit(orFRU)

Anyentitythatcanbereplacedbyauserinthefield.NotallFRUsarehot-swappable.Atitsmostbasic,theFRUdoesnothaveanIPMControllerontheassemblyand,hence,isnotdirectlycontrollablethroughtheIPMIinfrastructure.BasicproductinventorydatafortheFRUmaybemaintainedataproxyIPMControllerelsewhereintheShelf.ExamplesofthistypeofFRUmightinclude:backpanel(theShelfhousing,forallpracticalpurposes),powerentrymodule,fanmodule,PMC,andRTMs.

FrontBoardorBoard

ABoardthatconformstoPICMG®3.0mechanicals(8Ux280mm),includingaPCB

andaPanel.Further,aBoardconnectswiththeZone1andZone2Backplaneconnectorsand,optionally,mayconnectwithaZone3MidplaneConnectorordirectlytoanRTMconnectorandisinstalledintothefrontportionofaShelf.

FullMeshTopology

FullMeshconfigurationsmaybesupportedwithintheFabricInterfacetoprovideonededicatedChannelofconnectivitybetweeneachpairofSlotswithinaShelf.FullMeshconfiguredBackplanesarecapableofsupportingMeshEnabledBoardsorHubandNodeBoardsinstalledinaDualStararrangement.(akaFullMeshBackplane)

Term

Definition

IntelligentFRU

AFRUcontaininganIPMController.IntelligentFRUsincludetheNodeandHubBoards,andtheycouldalsoincludeotherFRUssuchasthefantray,powersupplies,alarmboards,etc.

RearBoard,RearTransitionModule,orRTM

An8Ux70mmx6HPassemblyinstalledintotherearportionofaShelfandmatedwithaFrontBoardthroughZone3connectorstoprovideI/Oconnectivity.

ReplicatedMeshTopology

ReplicatedMeshconfigurationsprovidemultipleChannelsofFabricInterfaceconnectivityamongtheSlotswithinaShelf.ThenumberofChannelsprovidedbetweenanytwoSlotsisdependentontheSlotcount.

Shelf

TheShelfconsistsoftheSubrack,Backplane,FrontBoards,coolingdevices,RTMs,powersupplies,etc.Alsohistoricallyknownasachassis.

ShMC

ShelfManagementController.AnIPMCthatisalsocapableofsupportingthefunctionsrequiredoftheShelfManager.

Star

ABackplanetopologyhavingoneofmoreHubSlotsprovidingconnectivityamongthesupportedNodeSlots

Subrack

TheSubrackprovidestheinterfacetoPICMG®3.0Boardsandconsistsofthe

GuideRails,ESDdischarge,alignment/keying,Handleinterface,FacePlatemountinghardware,EMCgasketing,andBackplaneinterface.TheSubrackisasubsetoftheShelf.

Zone1

ThelinearspacealongtheheightdimensionofanAdvancedTCA™Slotallocatedforpower,management,andotherancillaryfunctions.

Zone2

ThelinearspacealongtheheightdimensionofanAdvancedTCA™SlotallocatedtotheDataTransportInterface.

Zone3

ThelinearspacealongtheheightdimensionofanAdvancedTCA™Slotreservedforuserdefinedconnections.

Mechanical

ThissectiondefinestheessentialmechanicalfeaturesforPICMG®3.0compliantplatforms.TheFrameandCabinetmountingstandards,containedinANSI/EIA310-DSection1,IEC60297-1,andIEC60297-2,governtheoveralldimensionsoftheShelfresultingina“softmetric”equipmentpracticeadaptabletotelecommunicationscentralofficeanddatacenterinstallationsthroughouttheworld.

Thebasicelementsoftheplatformareasfollows(see

Figure1,“Formfactor

”):

FrontBoardscontainingthedesiredelectronicfunctionsandtheconnectorsrequiredtointerfacewiththesefunctions.TheFrontBoardis8Uhigh,30.48mmwide,andapproximately280mmdeep.Asmandatoryfeatures,theFrontBoardincludesaFacePlateandtwoHandles.Optionally,theFrontBoardmayincludeacoveronComponentSide2and/oronComponentSide1.OntheFrontBoard,threeconnectorzonesaredefined:Zone1forpowerconnectionandShelfmanagement,Zone2forDataTransportInterface,andZone3foruser-definedIO(Input/Output)interconnect.

RTMsprovidinguserdefinedinputandoutputconnectivitytothecompanionFrontBoardfromtherear.

TheBackplaneprovidingconnectorinterfacesforpowerdistributionandinput/outputconnectivitybetweenFrontBoards,aswellasfinalmechanicalalignmentandsupport.

TheSubrackprovidingattachmentpointsfortheBackplane,aswellasalignment,support,andmechanicalengagementfortheinsertionandextractionofFrontBoardsandRTMs

Zone3

25mm

25mm

RearpanelIOInterconnect

90mmOpticalCabling/AirPlenum

FrontBoard(8Ux280mm)(140in2)

1.2”pitch

Zone2:

Keying/alignment

Synch.Clocks

UpdateChannels

FabricInterface

BaseInterface

75mmMetallicCabling/Air

Rear Plenum

TransitionModule(8Ux

70mm

x1.2”)

(35in2)

Zone1:

Power

Management

322.25mm

(12.697”)

Upto4standardPMCs

Zone3

FrontAccessDoor

RearAccessDoor

Figure1Formfactor

Zone2

Z1

Note: Shelfmaybe19”,23”,or600mmETSI.

FrontBoardassembly

TheFrontBoardPCBformfactorshallbeasdefinedin

Figure2,“FrontBoardPCBformfactor.”

SeeexceptionsinSection2.2.1ofthePICMG3.0specification.

EachFrontBoardshallprovideamulti-segmentdischargestriplocatedonComponentSide1alongthebottomedgeofthePCB.CoversmaybeusedwithFrontBoardsforstiffeningthePCB,EMCandelectricalprotection,minimizingflamespread,and/orphysicalprotectionofcomponents.TheAdvancedTCATMFrontBoardtoFrontBoardpitchshallbe30.48mm(6HPor1.2in).ThePCBshallbepositionedbetweentwoPitchLinessothatthePCB'sComponentSide1surfaceshallbe6.61mmfromtheleftsidePitchLine.ThemaximumComponentSide1heightshallbe21.33mm.The“nocomponentzone”betweenthetwoFrontBoardsshallbe2.54mmwideandshallprovideforelectricalClearancetothenextFrontBoardand/ortheright-handSubracksidewallforFrontBoards.

TheFrontBoardFacePlateshallbemountedintoan8USubrackata6HPpitch(oneSlot).ThethicknessoftheFrontBoardisnotdefinedinthisspecification.FacePlatemetalthicknessshouldbe1.0mmtomaintainauniformlookandfeelamongmanufacturers.TheFrontBoardFacePlateHandlesshallrotatearoundthestandoffsforthemandatoryPCBmountingholesdefinedin

Figure2,“FrontBoardPCBformfactor,”

andshallbedesignedtohaveaSubrackinterface.

Figure2FrontBoardPCBformfactor

EachFrontBoardshallhaveanAlignmentandSafetyGroundpinonbothendsoftheFacePlate.Thesepinsshallbeimplementedevery6HPonmulti-SlotFacePlates,includingfillerpanelsandRTMs.

TheFrontBoardFacePlateshallhavetwocaptiveretentionscrewsandshallprovideretentionscrewholesatthetopandbottom.Fillerpanelsshallbeusedtocloseempty,shallincludeanEMCgasketandretentionscrews,andshallhaveFacePlateAlignmentandSafetyGroundpins.

FourgeneralstatusLEDpositionsandfunctionsaredefinedfortheFrontBoardFacePlate.TwooftheseLEDs(BLUELEDandLED1)aremandatory;useofLED2andLED3isoptional.

ThesefourLEDsshallbemountedonComponent2sideofthePCB.LegendsmaybeprovidedforeachoftheseLEDs.OneBLUELEDshallbeprovidedonallFrontBoardsandshallbepositionedatthebottomoftheFrontBoardFacePlate.LED1shallbecontrolledbyboththeIPMController(fortestoperations)andtheapplication(fornormalapplications).

FrontBoardFacePlate

TheFrontBoardFacePlateshallbeasdefinedin

Figure3,“FrontBoardFacePlateandRTMFacePlateEMC

gasket.”

FrontBoardFacePlatesprovideforaPCBfrontI/Ointerface.AnEMCgasketshallbelocatedontheComponentSide2edgeoftheFrontBoardFacePlateonboththeFrontBoardandRTM.

TheFrontBoardFacePlateshallbemountedintoan8USubrackata6HPpitch(oneSlot).ThethicknessoftheFrontBoardisnotdefinedinthisspecification.FacePlatemetalthicknessshouldbe1.0mmtomaintainauniformlookandfeelamongmanufacturers.TheinternalsurfaceoftheFacePlateshouldnotpenetratebehindtheFacePlateattachmentplane.

FrontI/OusingdevicesrequiringareturnpathtoShelfGroundshallimplementthisreturnpaththroughtheFacePlategroundpin.

TheFacePlateshallprovideforaHandleonbothends,AlignmentandSafetyGroundpinfeature,andretentionscrews.

FacePlatesmayneedtominimizeinsertiontorsiontoensureproperseatingandgasketing.ThismaybeaccomplishedbyaddingstiffenersoradditionalattachmentpointsbetweentheFacePlateandthePBA.

Figure3FrontBoardFacePlateandRTMFacePlateEMCgasket

FrontBoardFacePlateHandles

TheHandlesshallrotatearoundthestandoffsforthemandatoryPCBmountingholesandshallbedesignedtohaveaSubrackinterface.TheHandleshouldallowformaximumverticalFacePlateI/Ospace.ThemaximumlengthoftheHandlealongtheFacePlateshallbe50mmfromthecenterofthemountinghole.

ApositivemechanicalstoporothermeansshallbeprovidedtolocateHandlesattheirproperangularpositionpriortoFrontBoardinsertion.

AnimplementationfortheHandleSwitchandlatchmechanismisshownin

Figure4,“ExampleofHandleSwitch

andlatchmechanism.”

NotethatthisexampleimplementationmountstheswitchonthereturnflangeoftheFacePlate,soasinglepackagingsuppliercansupplyitalongwiththeFrontBoardFacePlate,Handle,andretentionmechanism.

Figure4ExampleofHandleSwitchandlatchmechanism

ProvisionforusingoptionalCMC/PMCMezzanineCards

Optionally,oneormore“CommonMezzanineCards”(CMCs)and“PCIonaCMC”(PMCs)maybeassembledtoBoards.

Amaximumoffour(4)CMCsorPMCsof75mmwidtharepossiblealongtheheightdimensionofaFrontBoard.Withtheejectorsillustratedabove,approximately304mmofverticalspacebetweenspacerequiredforejectorhandlemounting.Notethattheoveralllengthofthehandlesdoesnoteffectthefrontpanelspaceavailableformezzanines.

Thisprovidesapproximately2mmclearanceoneitherendoffourCMC/PMCcards,eachwitha75mmwideenvelope.

RTMassembly

RTMsareoptional.RTMssimplifyservicingofFrontBoardsbyputtingI/OcableassembliesontheRTM.I/OsignalsfromtheFrontBoardareroutedtoZone3whereauser-definedconnectormateswiththeRTMandtakesthesignalsoutsidetherearoftheShelf.ThisallowsFrontBoardstobequicklyandreliablyservicedwithouttheissuesassociatedwithdisconnectingandreconnectingmultiplecableassemblies.

IfRTMsareused,theymayconnecttotheFrontBoardviaZone3connections,buttheyshallnotmakeanyconnectiontotheZone1/Zone2Backplane(excepttherA1alignment/keyingfeature).

ThisspecificationdefinestheRTMenvelopeandelectromechanicalinterfaces.ThespecificimplementationofanRTMmaybeaPCB,wiringharness,orotherconstructionandislefttotheuser.

IftheRTMconsistsofaPBA,itshallbe“in-line”withtheFrontBoard.TheEMCgasketsoftheRTMsshallbelocatedonComponentSide2oftheFacePlate.

Zone1,2,and3connectors

TheZone1connectorshallbetheonlyinterfacebetweenAdvancedTCATMBackplanesandFrontBoardsfordualredundant-48VDCpower,metallictest,ringinggenerator,Shelfmanagementsystemconnections,andHardwareAddressing.

Zone2definestheuseoffiveBackplaneconnectors,P20throughP24,tosupporttheDataTransportInterface.ItprovidesforuptofiveZDconnectorsperFrontBoardtocovertheBaseInterface,FabricInterface,UpdateChannelInterface,andSynchronizationClockInterface.

Zone3includesspaceforkeyingand95.1mmPCBedgespaceforconnectors.ItprovidesaflexiblemethodforuserdefinedI/OsignalstoberoutedtoeitheranRTM,aZone3midplaneextension,orabulkhead-mountedconnector.TheconnectortypeinZone3isnotdefined,ratheritislefttotheusertochoosetheinterconnecttechnologythatbestmeetstherequirements.

TheconnectortypeinZone3isnotdefined;rather,itislefttotheusertochoosetheinterconnecttechnologythatbestmeetstherequirements.A2/K2alignmentandkeyingshallbeusedtopreventincompatibilities.

FrontBoardandRTMalignment/keying

TheFrontBoardisalignedbyafour-stagealignmentsystem:1)GrossalignmentintheSubrackisachievedasthePCBedgeispositionedwithintheGuideRails;2)TheAlignmentandSafetyGroundpinsontheBackplaneandRTMalignwiththereceptaclesontheFrontBoardorRTM;3)TheAlignmentandSafetyGroundpinsontheFrontBoardFacePlatealignwiththereceptaclesinthehorizontalmembers;and4)ThealignmentfeaturesoftheZone1andZone2connectorsthemselves(note:Zone1matesfirst).

KeyingisusedtopreventamismatchbetweenFrontBoardsandBackplanesorbetweenFrontBoardsandRTMs.PhysicalkeyingpreventstheinstallerfromdamagingconnectorsbyattemptingtomateaFrontBoardtoamidplaneorRTMthathaveincompatibleconnectortypes,offsetconnectorlocations,orincompatiblevoltagelevelsthatcannotbehandledbyElectronicKeying.

ForZone1andZone2connectoralignment,BackplanealignmentfeaturesshallbeimplementedtoensureFrontBoardandBackplaneconnectorsarealignedproperlyduringmating.TheBackplaneshallimplementtheA1alignment/keyingfeatureateverySlotpositionasshownin

Figure5,“Backplanealignment/keyingfeature(A1).”

TheFrontBoardshallimplementtheK1keying/alignmentfeatureasshownin

Figure6,“FrontBoardand

alignment/keyingfeatures(K1,K2).”

Figure5Backplanealignment/keyingfeature(A1)

Figure6FrontBoardandalignment/keyingfeatures(K1,K2)

Backplanes

PICMG®3.0Backplanesshallhavethicknessfrom3to8mm.ThenumberofFrontBoardSlotsaccommodatedbytheBackplaneshallbebetween2and16.TheBackplanehasmountingholestoattachtothesubrack,mountingholesforaBackplanesupportbar,andmountingholesforanalignment/keyingmechanismthatislocatedabovetheZone2connectors.

TheBackplanedistributespower,metallictestbus,ringgeneratorbus,andlow-levelShelfManagementsignalsthroughtheZone1connectors.TheBaseInterface,FabricInterface,UpdateChannelInterface,andSynchronizationClockInterfacesignalsaredistributedthroughtheZone2connectors.

Subrack

TheSubrackprovidesthemechanicalinterfacetoPICMG®3.0FrontBoardsandconsistsof:GuideRails,ESDdischargeclips,alignment/keying,Handleinterface,FacePlatemountinghardware,EMCgasketing,andBackplaneinterface.TheSubrackconstructionmaterialsanddesigndetailsarenotdefined;onlytheFrontBoardtoSubrackinterfacedimensionsaredefined.

TheSubrackshallsupportPICMG®3.0formfactorFrontBoards.ASubrackshallprovideforan8UfrontheightandtheDcdepthdimension(295.6mm±0.5mm).TheBackplanesupportbarshallprovideforZone1/Zone2BackplanetoSubrackattachmentfeatures.

TheSubrackfrontand(optional)rearshallprovidefortheFacePlateAlignmentandSafetyGroundpin/25AgroundreceptacleandtheretentionscrewM3threadedholes.TheEMCSubrackgasketshallbemountedontherightsideofthefrontSubrackopening(whenviewedfromthefront).

TheFrontBoardandRTMGuideRailsshallhavethePCBguidancefeatureinthe6.61mmoffsetpositionandshallbepresentatevery6HPintheSubrack.TheSubracksshallholdtheFrontBoardandoptionalRTMsunderthespecifiedshock,vibration,andearthquaketestrequirements.

TheSubrackshallprovideAlignmentandSafetyGroundpinreceptaclestomatewithpinsatbothendsoftheFrontBoardFacePlateandFacePlatesfortheoptionalRTM.

TheSubrackshallprovideM3threadedretentionscrewreceptaclesattheFrontBoardattachmentsurfaceandRTMattachmentsurface.

TheSubrack,aspartofthestructureoftheShelf,shallsupporttheweightoftheFrontBoardsandoptionalRTMs.

SubrackintegritytestsprovideSubrack/Shelfmanufacturerswithdesign/testrequirementsforestablishingminimumperformanceacceptancelevelsandprovidingguidancewhentheendusersystemconfigurationisunknown.

PhysicalSlotnumberingshallbeginfromlefttorightforFrontBoardsasviewedfromthefrontinthestandardorientationandfrombottomtotopinthehorizontalorientation.Numberingshallbeginwithnumeral1andshallincreasebyincrementsofone.

Shelf

TheFrontBoardformfactorhasbeendesignedforuseina12Uverticalsystem,butalternateShelfconfigurationssuchaslow-profile“pizzaboxes”andothersystemsizesareallowed.SinceFrontBoardsrequirefilteredair,Shelvesshallprovidefilteringunlessfilteringisprovidedelsewhere.EachShelfshallprovideawriststrapterminalonthefrontoftheShelf.WriststrapterminalsshallbeunpaintedterminalsconnectedtoShelfGroundandshallbemarkedtoindicateESDfunction.Abananaplug/jackassemblyshallbeusedfortheESDwriststrapconnections.Shelf-levelalarmreportingresourcesmaybeprovidedontheShelf.

CablemanagementmustbedeterminedattheFrame,Shelf,andFrontBoard/RTMlevel.Withineachofthesethreeareas,therearethreetypesofcablemanagementtobeconsidered:powercablemanagement,I/Ocoppercablemanagement,andI/Oopticalfibercablemanagement.

Powerentry

PowerentryintoaPICMG®3.0Shelfissubjecttovariousendcustomerrequirements.Thedistributionofthemain“A”and“B”officeFeedsvary.TheFeedsmaybeconnectedtotheShelfusingsinglepointswithadequaterating.

PowerentryterminalsorconnectorsshallmeettheaccessibilityandspacingrequirementsinSub-clause2ofIEC60950.Powerentrymaybebyconnectororbypowerstud.Ifaconnectorisused,itshallbeakeyedorpolarizedconnector.

Shelfmountingholepatternandlocation

Shelfmountingpatternsvarydependingupontheend-userenvironment.Twomajorstandardstodesignforare:

Inch-basedmountingholepatternperEIA-310andIEC60297-1

Metric-basedmountingholepatternperIEC60917-2

Shelfmountinglocationvariesdependingupontheend-useenvironment.Therearethreebasicoptions:

Frontflangemount

Midmount

Frontmountandrearmountsupport

Shelfmanagement

AdvancedTCA™providesforextensivemanagementcapabilities,whichmaybeusedbytheoverallSystemManager.Multiplelevelsofmanagementservicesareprovidedorfacilitated:

Low-levelhardwaremanagementservices

HighspeedmanagementservicesbasedontheTCP/IPprotocolsuite

In-bandapplicationmanagement

TheShelfmanagementcontentofthisspecificationfocusesonthelowlevelhardwaremanagementservices.Anarchitectureforhigh-speedmanagementservicesisoutlined.In-bandapplicationmanagementisoutsidethescopeofthisspecification.

TheShelfmanagementsystemdoesthefollowing:

Monitors,controls,andassuresproperoperationofAdvancedTCA™BoardsandotherShelfcomponents

Watchesoverthebasichealthofthesystem,reportsanomalies,andtakescorrectiveactionwhenneeded

RetrievesinventoryinformationandsensorreadingsaswellasreceiveeventreportsandfailurenotificationsfromBoardsandotherIntelligentFRUs

Performsbasicrecoveryoperationssuchaspowercycleorresetofmanagedentities

Provideslow-levelhardwaremanagementservicestomanagethepower,cooling,andinterconnectresourcesofaShelf

AdvancedTCA™allowssystemswitheither1)allcomponentsoperatedbyasingleowneror2)componentsoperatedbymultipleowners(Multi-tenancy).

TheShelfmanagementsystemiscomprisedofseveralmajorcomponents:

DistributedmanagementcontrollersthatmanageandmonitortheoperationandhealthofeachFRUinthesystem.

AnIntelligentPlatformManagementInterface(IPMI)infrastructurethatprovidescommunications,management,andcontrolamongthedistributedcontrollersandtoanoverallSystemManager.

Ahigher-level,high-speedserviceforBoardsthatneedTCP/IP-basedmanagementservicessuchasremotebooting,SNMPmanagement,remotediskservices,andotherIP-basedservices.

Shelfmanagementarchitecture

Figure7,“ManagementaspectsofanexampleofAdvancedTCA™Shelf,”

showsthelogicalelementsofanexampleAdvancedTCA™Shelf,withanemphasisonmanagement-relatedaspects.

Figure7ManagementaspectsofanexampleofAdvancedTCA™Shelf

IPMController(IPMC)

ShelfManagementController(ShMC)

AdvancedTCABoard

ShelfManagerw/DedicatedShMC

OtherFieldReplaceableUnit(FRU)

SystemManger

Shelf-ExternalSystemManager

ShelfManager(Active)

ShelfManager(Backup)

FanTray

PowerEntryModule

PowerEntryModule

Key

ImplementationDependentConnection

IPMC

2xRedundant,BussedorRadial,IPMB-0

ATCA

Board

ATCA

Board

ATCA

Board

ATCA

Board

ATC

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论