版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
AS/NZS61347.1/Amdt1/2018-03-22STANDARDSAUSTRALIA/STANDARDSNEWZEALANDAmendmentNo.1toAS/NZS61347.1:2016LampcontrolgearPart1:Generalandsafetyrequirements(IEC61347-1:2015,MOD)REVISEDTEXTThe2016editionofAS/NZS61347.1isamendedasfollows;theamendmentsshouldbeinsertedintheappropriateplaces.SUMMARY:ThisAmendmentappliestothePreface,andAppendicesZZandZA(new).Publishedon22March2018.ApprovedforpublicationinNewZealandonbyNewZealandStandardsApprovalBoardon4October2017.AMDTNo.1MAR2018
PrefaceDeletethethirdparagraphandreplacewiththefollowing:ThisStandardisanadoptionwithnationalmodificationsasshowninAppendixZZandhasbeenreproducedfromIEC61347-1,Ed.3.0(2015),Lampcontrolgear,Part1:Generalandsafetyrequirements,andhasbeenvariedasindicatedtotakeaccountofAustralian/NewZealandconditions.Addthefollowingtextafterthethirdparagraph:Amendment1tothisStandardaddsrequirementsforlampcontrolgeartoaddresssafetyissuesidentifiedwherelampcontrolgearisusedincloseproximitytoorunderbuildingthermalinsulation.TheserequirementstakeintoaccountrequirementsfromAS/NZS60598.2.2,Luminaires,Part2.2:Particularrequirements—Recessedluminaires(IEC60598-2-2,Ed.3.0(2011)MOD),whichapplytorecessedluminaireswhenusedinconjunctionwithbuildingthermalinsulation.Addthefollowingtextaftertheninthparagraph:Amendment1addsadditionalrequirementsandtestproceduresforlampcontrolgearusedincloseproximitytoorunderbuildingthermalinsulation.Theseareshownin—AppendixZZ;andAppendixZA.ThevariationslistedinAppendixZZandAppendixZAincludethefollowing:Classificationsanddefinitionsofindependentlampcontrolgearforusenear,orbeingcoveredwith,buildingelementsorthermalinsulation,orboth.Tests,includingingressprotectiontestsandthermaltestsfornormalandabnormaloperatingconditions,andmarkingandinstructionalrequirementsforthedifferentclassifications,withstandardizedtestbox,temperaturelimits,andrequirementsforanythermalprotection.AS/NZS61347.1:2016initsunamendedformwillalsoremaincurrentfor12months.AfterthistimeitwillbesupersededbyAS/NZS61347.1:2016incorporatingAmendment1.RegulatoryauthoritiesthatreferencethisstandardinregulationmayISBN9781760720322applytheserequirementsatadifferenttime.Usersofthisstandardshouldconsultwiththeseauthoritiestoconfirmtheirrequirements.Deletethefollowingtwoparagraphs:VariationsmadetoIEC61347-1,Ed.3.0(2015)formtheAustralianandNewZealandvariationsforthepurposeoftheIECEECBSchemeforrecognitionoftestingtostandardsforsafetyofelectricalequipment(theCBScheme).TheyarelistedinAppendixZZ.ThenationaldifferencesdescribedinAS/NZS61347.1:2002(IECedition1.0)willapplytotheIECedition1.0,2.0and2.1.Addthefollowingtextbeforethelastparagraph:StandardsAustraliaLimitedandTheCrowninrightofNewZealand,administeredbytheNewZealandStandardsExecutivethanktheInternationalElectrotechnicalCommission(IEC)forpermissiontoreproducesymbolsinFigures701and702withmodificationfromIEC60598-1:2014andIEC61347-1:2015.IEC60598-1:2014andIEC61347-1:2015arethecopyrightofIEC,Geneva,Switzerland.Allrightsreserved.FurtherinformationontheIECisavailablefromwww.iec.ch.IEChasnoresponsibilityfortheplacementandcontextinwhichtheextractsandcontentsarereproducedbyStandardsAustraliaLimitedandTheCrowninrightofNewZealand,administeredbytheNewZealandStandardsExecutive,norisIECinanywayresponsiblefortheothercontentoraccuracytherein.AppendixZZ,ParagraphZZ2ClauseAMDTNo.1MAR2018AttheendoftheexistingvariationtoClause1,addthefollowingtext:AMDTNo.1MAR2018Amendment1specifiesadditionalsafetyrequirementsforindependentlampcontrolgeartoprovideadequateprotectioninrespectofthefireriskassociatedwiththecombinationofindependentlampcontrolgearusedwithrecessedluminaires,flammablebuildingelements,flammabledebrisandbuildinginsulation.AddthefollowingnewnormativereferencestothevariationstoClause2:AS60529,Degreesofprotectionprovidedbyenclosures(IPCode)AS/NZS4859.1,Materialsforthethermalinsulationofbuildings—GeneralcriteriaandtechnicalprovisionsAS/NZS61347,Lampcontrolgear(allparts)AddthefollowingnewvariationtoClause3:3.1.2Addthefollowingtext:Independentlampcontrolgearincludeslampcontrolgearpermanentlyconnectedandlampcontrolgearabletobedisconnectedfromthelightsource.Independentlampcontrolgearabletobedisconnectedareconsidered“separatetotheluminaire”.NOTESeparateexcludescuttingconnectionwires.Hereafter,“lampcontrolgear”willbeshownas“controlgear”.AddnewClause3.101andClause3.102asfollows:Do-not-coverclassificationAnindependentcontrolgearthatcanbeusedwherenormallyflammablematerials,includingbuildinginsulation,areormaybepresent,butcannotbeabuttedagainstanymaterialandcannotbecoveredinnormaluse.ICclassificationAnindependentcontrolgearthatcanbeabuttedagainstnormallyflammablematerials,includingbuildinginsulation,andcanbecoveredinnormaluse.Buildingelements,buildinginsulationordebrishaverestrictedaccesstotheheatedpartsofthecontrolgear.NonICclassificationAnindependentcontrolgearthatcannotbeabuttedagainstorcoveredbynormallyflammablematerialsorusedininstallationswherebuildinginsulationordebrisis,ormaybe,presentinnormaluse.NOTEThisclassificationisnotsuitableforresidentialinstallations.1 DeletethefirstvariationtoClause4.2 AddthefollowingnewvariationafterClause4.101:AddnewClauses4.102and4.103asfollows:GeneralTheresistancetodustandsolidobjectprovisionsofSection9ofAS/NZS60598.1apply,excludingthehumiditytest,alongwiththefollowing:ForindependentcontrolgearwithanIPclassificationgreaterthanIP20,thetestsandcompliancecriteriaofSection9ofAS/NZS60598.1shallbeapplied.ForindependentcontrolgearwithanICclassification,theIP4XprobeorIPratingtestsofClause4.103andcomplianceshallbeapplied.IngresstestforICclassifiedcontrolgearSolidforeignobjectsshallhaverestrictedaccesstothehotsurfacesofICclassifiedcontrolgear.TheIP4XprobeofAS60529shallbeappliedtothecontrolgearwithoutappreciableforceandshallnotenteranyareawherethetemperatureofanypartorsurfaceexceedsthetemperaturelimitfor‘mountingsurface:normallyflammablesurface’ofAS/NZS60598.1,whenthesurfaceismeasuredwhilethecontrolgearisoperatedinaccordancewiththethermaltestconditionsofParagraphZA1.NOTEThistestisintendedtoensurefineflammableinsulationmaterialordebrisisunlikelytoentercontrolgearandcauseafire.AddasecondvariationtoClause5,afterClause5.101,asfollows:AddnewClauses5.102,5.103and5.104asfollows:IndependentcontrolgearforusenearorincontactwithbuildingmaterialorinsulationIndependentcontrolgearshallbe—classified,markedandtestedforsuitabilityforusenearbuildingmaterialsorinsulationandclassified“DonotCover”,orclassified,markedandtestedforsuitabilityforuseincontactwithbuildingmaterialsandcoverablewithinsulation,andclassifiedas“IC”.Thermaltestsfor“Do-not-Cover”classifiedcontrolgear“Donot-Cover”controlgear,normaloperationtestControlgearclassifiedas“DonotCover”shallbetestedinaccordancewiththerequirementsofClause5.5.“Do-not-Cover” classified controlgear, abnormaloperationtestControlgearclassifiedas“DonotCover”shallbetestedinaccordancewiththerequirementsofParagraphZA3.Whenthe“DonotCover”controlgearistestedinaccordancewithParagraphZA3,notemperatureshallexceed—90°Conthemountingsurfaceofthetestbox;and130°Contheoutersurfaceofthecontrolgear.Thereshallbenodamagetothecontrolgearsuchasscorching,deformationormelting.Duringthetest,thermalprotectivedevicesorelectroniccontrolswithinthecontrolgearmayoperatetolimittemperatures.Thermaltestsfor“IC”controlgearControlgearclassifiedas“IC”shallbetestedinaccordancewiththerequirementsofParagraphZA3.When the “IC” controlgear is tested in accordance withParagraphZA3,notemperatureshallexceed—90°Conthecontrolgearmountingsurface;andthelesseroftcor90°ContheoutsidesurfaceofthecontrolgearorotherplacesaccessibletotherelevanttestprobeofClause4.103.Thereshallbenodamagetothecontrolgearsuchasscorching,deformationormelting.Duringthetest,nothermalprotectiondevice,orelectroniccontrolthatfullyturnsoffthecontrolgearshalloperate.AddthefollowingnewvariationtoClause6:AddnewClause6.101asfollows:6.101IndependentcontrolgearclassificationIndependentcontrolgearshallbeclassifiedasoneofthefollowing:Do-not-Cover.IC.NonIC.DeleteParagraph2intheexistingvariation:‘Themarkingoftheratedvoltageorratedvoltagerangeshallinclude240VforAustraliaand230VforNewZealand.’AddthefollowingnewvariationtoClause7.1aftertheexistingvariation:AddnewClauses7.101,7.102,7.103,7.104and7.105asfollows:ControlgearclassificationsymbolIndependentcontrolgearshallbemarkedwiththesymbolshownintheappropriatefigureofthisclauseandthemeaningexplainedintheinstructionsprovidedwiththecontrolgear.Controlgearclassifiedas“NonIC”doesnotrequiretobemarked.Controlgearclassifiedas“DonotCover”shallbemarkedwiththesymbolshowninFigure701.ReproducedwithmodificationsfromIEC60598-1:2014Ed.8.0.Copyright©2014IECGeneva,Switzerland.www.iec.chReproducedwithmodificationsfromIEC61347-1:2015Ed3.0.Copyright©2014IECGeneva,Switzerland.www.iec.chFIGURE701REQUIREDSYMBOLFORDO-NOT-COVERCONTROLGEARControlgearclassifiedas“IC”shallbemarkedwiththesymbolshowninFigure702.ReproducedwithmodificationsfromIEC60598-1:2014Ed.8.0.Copyright©2014IECGeneva,Switzerland.www.iec.chReproducedwithmodificationsfromIEC61347-1:2015Ed.3.0.Copyright©2014IECGeneva,Switzerland.www.iec.chFIGURE702REQUIREDSYMBOLFORICCONTROLGEARNOTETheindependentcontrolgearsymbolandthesymbolfor“DonotCover”and“IC”canbecombinedtoberepresentedasshownabove.Additionalinformationtobesuppliedwiththecontrolgear“Do-not-cover”and“Non-IC”classifiedcontrolgearshallbesuppliedwithinstructionsanddiagramsshowingalldimensionsforsafeinstallationandinclude,asappropriate,thefollowing:Theminimumclearancedistancefromthetopandsidesofthecontrolgeartonormallyflammablebuildingelements.Iftheminimumclearancedistancesfromeachsideofthecontrolgeararedifferent,ortherearedifferentminimumclearancedistancesforvarioustypesofnormallyflammablebuildingelementorbuildinginsulation,theneachminimumclearancedistanceshallbestatedseparately.Wherecontrolgearisrequiredtobemountedonaspecificsurfaceorhasadditionalinstallationrequirements,forexample,useinnon-combustibleenclosedspaceortoensureadequatesealingtomaintainitsIPrating,therelevantinformationshallbesuppliedwiththecontrolgear.NOTEInstallationinanon-combustibleenclosedspacemayincludeinstallationinarebateinaconcreteslab,ceilingorwall.IndependentcontrolgearForindependentcontrolgearnotsuppliedwith,butintendedforusewith,aseparatelamporlightsourcecontainerorhead,forexample,aremotemountedfloodlight,theinstructionssuppliedshallspecifytheindependentcontrolgearparametersforusebytheluminaireassembler.LocationanddurabilityofmarkingThemarkingrequiredbyClause7.101shallbeaminimumsizeof5mm5mm.ComplianceCompliancewithClauses7.101to7.104ischeckedbyinspection.AppendixZA(new)AddnewAppendixZAasfollows:APPENDIXZATHERMALTESTPROCEDUREFORINDEPENDENTCONTROLGEAR(Normative)ZA1GENERALForthepurposesofthisAppendix,therequirementsofClause12ofAS/NZS60598.1apply,withthefollowingmodificationsandadditions:Independentcontrolgearshallbeenergizedat0.94or1.06timestheratedvoltage,whicheverproduceshighertemperatures.Thetestisrununtiltemperatureshavestabilizedor8hhaveelapsed.Thedimensionsofthetestboxshallbeaminimumof450mmwide450mmlong300mmhighandshallmaintainaminimumhorizontaldistanceof75mmfromthesidesandendsofthecontrolgeartothesidesofthetestboxandtheminimumverticaldistanceof75mmfromthetopofthecontrolgeartotheundersideofthetestboxtopwhenplacedinaccordancetoClauseZA3.2.Theinternalsurfacesshallbepaintedmattblack.TemperaturemeasurementsareconductedinaccordancewithAnnexKofAS/NZS60598.1onthehottestpoints.ZA2TESTBOXAtestbox,consistingofamountingsurfaceontopofwhichisarectangularboxwithverticalsidesandatop,shallbeconstructedinaccordancewiththefollowing:Themountingsurfaceshallbemadeof15mm–20mmthickporouswoodfibreboard.Theverticalsidesandtopofthetestboxshallbemadeof15mm–20mmthickporouswoodfibreboard.Thedimensionsofthetestboxshallbeaminimumof450mmwide450mmlong300mmhighandshallmaintainaminimumhorizontaldistanceof75mmfromthesidesandendsofthecontrolgeartothesidesofthetestboxandtheminimumverticaldistanceof75mmfromthetopofthecontrolgeartotheundersideofthetestboxtopwhenplacedinaccordancewithClauseZA3.2.Theinternalsurfacesshallbepaintedmattblack.Forthetests,thetestboxshallbesupportedorsuspendedinadraught-proofenclosureinaccordancewithAS/NZS60598.1,AnnexD.SeeFigureZA1.15-20mmIndependentcontrinstalledasperinstallationinstrucm450mm15-20mm450mmFIGUREZA1TESTBOX(WITHFRONT,SIDEANDTOPREMOVED)Thetestset-upisshowninFigureZA2.InsulationIndependentcontrolgearinstalledasperinstallationinstructionsFIGUREZA2TESTSET-UPFOR“DONOTCOVER—ABNORMALOPERATION”ANDICCONTROLGEARZA3CONTROLGEARTESTPROCEDUREFOR“DONOTCOVER—ABNORMALOPERATION”ANDIC(ALLSITUATIONS)ZA3.1GeneralThistestprocedureisforboth‘DonotCover—abnormaloperation’andICcontrolgear.Itassessesthesuitabilityofthecontrolgeartoabutnormallyflammablematerials,asspecifiedintheinstallationinstructions,andbecoveredbyinsulation,inadvertently(donotcover—abnormaloperation)orbyintent(ICallsituations).ZA3.2Testset-upThecontrolgearundertestisplacedinthecentreofthetestboxasshowninFigureZA1.Thermalinsulationisthenaddedtothetestboxtocompletelyfillthetestbox.Theinsulationispushedaroundthecontrolgeartoformaclosefittothesidesandtopwithoutcompression.Thetypeofthermalinsulationisformedinsulationwhere200mmisequivalenttoanRI4.0classificationinaccordancewithAS/NZS4859.1orasspecifiedinAS/NZS60598.1.Thetestset-upshallhavethermocouplesattachedtothecontrolgear(onaccessiblesurfaces,inaccordancewiththespecifiedclassificationandaccessprobe),controlgearmountingsurface,andanythermalinsulationinthemostunfavourablepositions.NOTE:ThetestconditionsshownareintentionallysimilartothoseusedfortestingrecessedluminairestoAS/NZS60598.2.2asindependentcontrolgearisincreasinglybeingusedwiththesetypesofluminairesorwherecontrolgearmayneedtobeconcealedfromview,thatis,insideceilingsorwallswhereinsulationmaybepresent.InAS/NZS60598.2.2,thermalinsulationfullyenclosingtheluminaireisconsideredtobetheworstcaseevenwherethesimulatedbuildingelementsandminimumdistancesareallowedbythemanufacturer’sinstructions.Thetestboxshallhaveitstopaddedandsealed.Thetestset-upisshowninFigureZA2.AS/NZS61347.1:2016AS/NZS61347.1:2016AS/NZS61347.1:2016Australian/NewZealandStandard™AS/NZS61347.1:2016LampcontrolgearPart1:Generalandsafetyrequirements(IEC61347-1:2015,MOD)AS/NZS61347.1:2016ThisJointAustralian/NewZealandStandardwaspreparedbyJointTechnicalCommitteeEL-041,LampsandRelatedEquipment.ItwasapprovedonbehalfoftheCouncilofStandardsAustraliaon19November2015andonbehalfoftheCouncilofStandardsNewZealandon12February2016.ThisStandardwaspublishedon9March2016.ThefollowingarerepresentedonCommitteeEL-041:AustralianIndustryGroupConsumers’FederationofAustraliaDepartmentofIndustryElectricalComplianceTestingAssociationElectricalContractorsAssociationofNewZealandElectricalRegulatoryAuthoritiesCouncilEnergyEfficiencyandConservationAuthorityofNewZealandFairTradingNSWIES:TheLightingSocietyIndependentPricingandRegulatoryTribunalInstitutionofProfessionalEngineersNewZealandJointAccreditationSystemofAustraliaandNewZealandLightingCouncilAustraliaLightingCouncilNewZealandMastersElectriciansMinistryofBusiness,InnovationandEmployment,NewZealandAdditionalInterests:AustralasianFireandEmergencyServiceAuthoritiesCouncilKeepingStandardsup-to-dateStandardsarelivingdocumentswhichreflectprogressinscience,technologyandsystems.Tomaintaintheircurrency,allStandardsareperiodicallyreviewed,andneweditionsarepublished.Betweeneditions,amendmentsmaybeissued.Standardsmayalsobewithdrawn.ItisimportantthatreadersassurethemselvestheyareusingacurrentStandard,whichshouldincludeanyamendmentswhichmayhavebeenpublishedsincetheStandardwaspurchased.DetailedinformationaboutjointAustralian/NewZealandStandardscanbefoundbyvisitingtheStandardsWebShopat.auorStandardsNewZealandwebsiteatwww.standards.co.nzandlookinguptherelevantStandardintheon-linecatalogue.Formorefrequentlistingsornotificationofrevisions,amendmentsandwithdrawals,StandardsAustraliaandStandardsNewZealandofferanumberofupdateoptions.Forinformationabouttheseservices,usersshouldcontacttheirrespectivenationalStandardsorganization.WealsowelcomesuggestionsforimprovementinourStandards,andespeciallyencouragereaderstonotifyusimmediatelyofanyapparentinaccuraciesorambiguities.PleaseaddressyourcommentstotheChiefExecutiveofeitherStandardsAustraliaorStandardsNewZealandattheaddressshownonthebackcover.ThisStandardwasissuedindraftformforcommentasDRAS/NZS61347.1:2015.AS/NZS61347.1:2016AS/NZS61347.1:2016Australian/NewZealandStandard™LampcontrolgearPart1:Generalandsafetyrequirements(IEC61347-1:2015,MOD)OriginatedasAS/NZS61347.1:2002.Secondedition2016.COPYRIGHT©StandardsAustraliaLimited/StandardsNewZealandAllrightsarereserved.Nopartofthisworkmaybereproducedorcopiedinanyformorbyanymeans,electronicormechanical,includingphotocopying,withoutthewrittenpermissionofthepublisher,unlessotherwisepermittedundertheCopyrightAct1968(Australia)ortheCopyrightAct1994(NewZealand).JointlypublishedbySAIGlobalLimitedunderlicencefromStandardsAustraliaLimited,GPOBox476,Sydney,NSW2001andbyStandardsNewZealand,PrivateBag2439,Wellington6140.ISBN9781760354206AS/NZS61347.1:2016PAGEAS/NZS61347.1:2016PAGEPREFACEThisStandardwaspreparedbytheJointStandardsAustralia/StandardsNewZealandCommitteeEL-041,LampsandRelatedEquipmenttosupersedeAS/NZS61347.1:2002,Lampcontrolgear,Part1:Generalandsafetyrequirements(IEC61347-1:2000,MOD)sixmonthsafterpublication.Untilthattime,botheditionsoftheStandardwilloperateinparallel.Itisanticipatedthatthe2002editionwillthenbewithdrawn.Thisrevisionrelatestoratedvoltagerequirements,flammabilityandreferencedocumentchanges.TheobjectiveofthisStandardistospecifygeneralrequirementsforcontrolgearintendedforusewithluminaires,foroperationond.c.suppliesupto250Vand/ora.c.suppliesupto1000Vat50Hzor60Hz.TherequirementsandrelatedtestsofthisStandardcover:classification,marking,mechanicalconstructionandelectricalconstruction.ThisStandardisanadoptionwithnationalmodificationsandhasbeenreproducedfromIEC61347-1,Ed.3.0(2015),Lampcontrolgear,Part1:Generalandsafetyrequirements,andhasbeenvariedasindicatedtotakeaccountofAustralian/NewZealandconditions.TheIECeditionincludesthefollowingsignificanttechnicalchangeswithrespecttothepreviousedition:Additionalmarkingrequirements.Additionalrequirementsforcreepagedistancesandclearancesfor—workingvoltageswithoperatingfrequenciesupto30kHz;workingvoltageswithhigheroperatingfrequenciesthan30kHz;impulseandresonancevoltagesignition;basic,supplementaryandreinforcedinsulation;insulationbetweencircuits;andcoatedorpottedcontrolgear.ModificationofdefinitionofELVandFELV.Modificationofschematicdrawing,showingthedifferentcontrolgearclassificationandinsulationrequirements.Scopeextension.NewAnnexA—testtoestablishwhetheraconductivepartisalivepartwhichmaycauseanelectricshock.NewAnnexM—creepagedistancesandclearancesforcontrolgearwhereahigherdegreeofavailability(impulsewithstandcategoryIII)mayberequested.NewAnnexQ—exampleforUpcalculation.NewAnnexP—creepagedistancesandclearancesanddistancethroughisolation(DTI)forlampcontrolgearwhichareprotectedagainstpollutionbytheuseofcoatingorpotting.NewAnnexR—conceptofcreepagedistancesandclearances.VariationsmadetoIEC61347-1,Ed.3.0(2015)formtheAustralianandNewZealandvariationsforthepurposeoftheIECEECBSchemeforrecognitionoftestingtostandardsforsafetyofelectricalequipment(theCBScheme).TheyarelistedinAppendixZZ.ThenationaldifferencesdescribedinAS/NZS61347.1:2002(IECedition1.0)willapplytotheIECedition1.0,2.0and2.1.ThisStandardisstructuredasfollows:Preface.IEC61347-1,Ed.3.0(2015)uneditedfromthefirstclausetoBibliography.AppendixZZ—(Australian/NewZealand)variationstothesourcedocument.ThevariationslistedinAppendixZZaddressissuesincludingthefollowing:Supplyvoltage.Capacitorratings.RequirementsforFELVconnections.Resistancetoflameandignition.InthisStandard,thefollowingprinttypesareused:Requirementsproper:inromantype.Testspecifications:initalictype.Explanatorymatter:insmallerromantype.AsthisStandardisreproducedfromanInternationalStandard,thefollowingapplies:(aa) Inthesourcetext‘thispartofIEC61347’shouldread‘thisAustralian/NewZealandStandard’.(bb)Afullpointsubstitutesforacommawhenreferringtoadecimalmarker.ReferencestoInternationalStandardsshouldbereplacedbyreferencestoAustralianorAustralian/NewZealandStandards,asfollows:ReferencetoInternationalStandard Australian/NewZealandStandardIEC AS/NZS60065Audio,videoandsimilarelectronicsapparatus—Safety60065Audio,videoandsimilarelectronicapparatus—Safetyrequirementsrequirements(IEC60065,Ed.7.2(2011)MOD)60081Doublecappedfluorescentlamps—47824782.1Double-cappedfluorescentlamps—PerformancespecificationsPart1:General(IEC60081:2000,PerformancespecificationsMOD)60598Luminaires60598Luminaires60598-1Part1:Generalrequirementsandtests60598.1Part1:Generalrequirementsandtests(IEC60598-1,Ed.7.0(2008)MOD)60695Firehazardtesting60695Firehazardtesting60695-2-1060695-2-11Part2-10:Glowing/hotwirebasedtestmethods—Glow-wireapparatusandcommontestprocedurePart2-11:Glowing/hot-wirebased60695.2.1060695.2.11Part2.10:Glowing/hotwirebasedtestmethods—Glow-wireapparatusandcommontestprocedurePart2.11:Glowing/hotwirebased60695-11-5testmethods—Glow-wireflammabilitytestmethodforend-products(GWEPT)Part11-5:Testflames—Needle-60695.11.5testmethods—Glow-wireflammabilitytestmethodforend-productsPart11.5:Testflames—Needle-flametestmethod—Apparatus,confirmatorytestarrangementandguidanceflametestmethod—Apparatus,confirmatorytestarrangementandguidanceIEC AS/NZS60695-11-10Part11-10:Testflames—50Whorizontalandverticalflametestmethods
60695.11.10Part11.10:Testflames—50WhorizontalandverticalflametestmethodsOnlynormativereferencesthathavebeenadoptedasAustralianorAustralian/NewZealandStandardhavebeenlisted.Theterms‘normative’and‘informative’havebeenusedinthisStandardtodefinetheapplicationoftheannexorappendixtowhichtheyapply.A‘normative’annexorappendixisanintegralpartofaStandard,whereasan‘informative’annexorappendixisonlyforinformationandguidance.CONTENTSScope 12Normativereferences 12Termsanddefinitions 14Generalrequirements 22Generalnotesontests 22Classification 23Marking 24Itemstobemarked 24Durabilityandlegibilityofmarking 26Terminals 26Earthing 26Provisionsforprotectiveearthing(Symbol:IEC60417-5019(2006-08)) 26Provisionsforfunctionalearthing(Symbol:IEC60417-5018(2011-07)) 27Lampcontrolgearwithconductorsforprotectiveearthingbytracksonprintedcircuitboards 27Earthingofbuilt-inlampcontrolgear 27Earthingviaindependentcontrolgear 27Earthconnectiontootherequipment 27Earthingofthelampcompartmentspoweredviatheindependentlampcontrolgear 28Protectionagainstaccidentalcontactwithliveparts 28Moistureresistanceandinsulation 29Electricstrength 30Thermalendurancetestforwindingsofballasts 31Faultconditions 35Construction 39Wood,cotton,silk,paperandsimilarfibrousmaterial 39Printedcircuits 39Plugsandsocket-outletsusedinSELVorELVcircuits 39Insulationbetweencircuitsandaccessibleparts 39General 39SELVcircuits 40FELVcircuits 40Othercircuits 41Insulationbetweencircuitsandaccessibleconductiveparts 41Creepagedistancesandclearances 43General 43Creepagedistances 45General 45Minimumcreepagedistancesforworkingvoltages 46Creepagedistancesforworkingvoltageswithfrequenciesabove30kHz 46Compliancewiththerequiredcreepagedistances 47AS/NZS61347.1:2016PAGEPageAS/NZS61347.1:2016PAGEPageClearances 48General 48Clearancesforworkingvoltages 49Clearancesforignitionvoltagesandworkingvoltageswithhigherfrequencies 50Compliancewiththerequiredclearances 52Screws,current-carryingpartsandconnections 53Resistancetoheat,fireandtrac
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024年版夫妻双方财产分割补充协议模板
- 2024年工程分包及居间服务协议
- 保密合同约定书模板(2024年版)
- 2024年双边劳务居间合同模板
- 健身产品保修服务合同
- 2024年健身俱乐部会员服务合同:高端健身会所会员权益协议
- 2024年区块链应用平台搭建合同
- 2024年工程降水基坑施工合同
- 人才搜索与招聘协议书(2024年版)
- 2024年工程变更与索赔管理合同
- 机械加工工时定额时间标准
- 事业单位政审表
- GB 19517-2023国家电气设备安全技术规范
- 施工现场临时水电消防监理细则
- 山东东营市商业市场调研
- 一代元帅刘伯承
- 高压电力用户报装容量测算方法
- 学科分析:中等职业教育“民族音乐与舞蹈”专业学科分析
- 护栏有限公司液化气瓶安全风险分级管控清单
- 单层工业厂房结构吊装
- 消音器研究报告
评论
0/150
提交评论