纯铝中镁、铜、镍、铬、锌的连续测定_第1页
纯铝中镁、铜、镍、铬、锌的连续测定_第2页
纯铝中镁、铜、镍、铬、锌的连续测定_第3页
纯铝中镁、铜、镍、铬、锌的连续测定_第4页
纯铝中镁、铜、镍、铬、锌的连续测定_第5页
全文预览已结束

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

/纯铝中镁、铜、镍、铬、锌的连续测定秦文忠(平果铝业公司中心试验室,平果,531400)摘要:本文用原子吸收分光光度计对纯铝中镁、铜、镍、铬、锌等元素进行连续快速测定,方法精密度高,准确性好。关键词:纯铝、测定、原子吸收仪器试剂1.1原子吸收分光光度计(岛津AA-6800)1.2铝(99.99%)1.3硝酸(ρ1.42g/ml)1.4氢氟酸(ρ1.14g/ml)1.5过氧化氢(ρ1.10g/ml)1.6盐酸(1+1)1.7硫酸(1+1)1.8氯化锶溶液(50mg/ml)1.9镁标准溶液(0.05mg/ml)1.10铜标准溶液(0.01mg/ml)1.11镍标准溶液(0.025mg/ml)1.12铬标准溶液(0.025mg/ml)1.13锌标准溶液(0.01mg/ml)分析方法称取1.000g试样,于250ml烧杯中,盖上表皿,加入30-40ml水,分次加入总量为30ml盐酸(1+1),待剧烈反应停止后,置于电热板上缓慢加热至完全溶解,滴加适量的过氧化氢,加热煮沸10min,以除去过量的过氧化氢,冷却。如有不溶物,过滤,洗涤。将残渣连同滤纸置于铂坩埚中,灰化(勿使滤纸燃着),然后于550℃灼烧,冷却。加入2ml硫酸,5ml氢氟酸,并逐滴加入硝酸至溶液清亮。加热蒸发至干,于700将溶解后的试液移入100ml容量瓶中,加入2.0ml氯化锶(50mg/ml),以水稀至刻度,混匀。连同标准溶液于原子吸收分光光度计在设定好的参数下测量吸光度值。标准曲线的绘制3.1铝基体液的配制称取20.00g经酸洗的铝,置于1000ml烧杯中,盖上表皿。分次加入总量为800ml盐酸,加1滴金属汞助溶,待剧烈反应停止后,缓慢加热至完全溶解。加入数滴过氧化氢,煮沸数分钟分解过量的过氧化氢,冷却。将溶液移入1000ml容量瓶中,以水稀释至刻度,混匀。移取上述溶液50.0ml于1000ml容量瓶中,以水稀释至刻度,混匀。此溶液即为铝基(1mg/ml)。3.2标准曲线分别移取0,0.50,1.00,2.00,4.00ml镁、铜、镍、铬、锌标准溶液于一组250ml容量瓶中,各加入25.0ml铝基,20ml氯化锶,以水稀至刻度,混匀,于原子吸收分光光度计上测量吸光度。分析条件经实验测铜、锌时几乎无干扰,测铬时,镁、铜、铝等的干扰可调节流量加以抑制。测镁时铝、硅、钛的干扰可加氯化锶加以抑制。测镍时由于铁、铬浓度低,基本没干扰。最后选定的仪器分析参数如表1。表1、分析参数元素乙炔气流量ml/min空气流量ml/min燃烧器高度mm狭缝宽度nm波长nmMg1.6860.5285.2Cu1.8860.5324.8Zn2.0860.5213.9Cr2.2860.5357.9Ni1.7860.2232.0精密度试验利用上述分析条件,我们对一个试样重复进行10次测定,结果见表2。结果表明,该方法是稳定的,测定样品的重现性良好,有较好的可靠性。表2、精密度测定试验结果测定次数测定值(%)CuZnCrNiMg10.01120.02340.00380.01220.008820.01100.02370.00370.01230.008730.01140.02400.00380.01210.008940.01150.02340.00390.01190.008750.01100.02280.00380.01210.009060.01110.02320.00370.01190.008870.01130.02340.00400.01230.008780.01120.02360.00380.01190.008890.01110.02350.00360.01220.0087100.01130.02330.00370.01220.0086平均值0.01120.02340.00380.01210.0088标准偏差%0.0170.030.0110.00160.012相对标准偏差%1.491.352.991.321.31准确度试验对标准样品的分析结果见表3,从表中可见,该方法准确度较高。表3、准确度试验结果试样编号S1S2S3S4S5Cu标准值0.00650.00840.0340.00620.016测定值0.00590.00880.0360.00560.015误差0.00060.00040.0020.00060.001允许差0.00100.00150.0030.00100.002Zn标准值0.0160.0120.0210.00860.0049测定值0.0180.0140.0200.00940.0045误差0.0020.0020.0010.00080.0004允许差0.0030.0030.0030.00150.0006Mg标准值0.0100.00470.00760.00720.0088测定值0.0090.00520.00800.00790.0085误差0.0010.00050.00040.00070.0003允许差0.0010.0010.0010.0010.001Ni标准值0.00580.0560.01420.02510.032测定值0.00620.0510.01560.02630.030误差0.00040.0050.00140.00120.002允许差0.00100.0060.00250.00250.005Cr标准值0.00680.00960.0160.00430.0271测定值0.00610.01050.0150.00350.0290误差0.00070.00090.0010.

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论