JOINTINDUSTRYSTANDARD
IPC/JEDECJ-STD-033D
April2018
SupersedesIPC/JEDECJ-STD-033C-1August2014
Handling,Packing,ShippingandUseofMoisture,
Reflow,andProcessSensitiveDevices
Notice
JEDECandIPCStandardsandPublicationsaredesignedtoservethepublicinterestthrougheliminatingmisunderstandingsbetweenmanufacturersandpurchasers,facilitatinginterchangeabilityandimprovementofproducts,andassistingthepurchaserinselectingandobtainingwithminimumdelaytheproperproductforhisparticularneed.ExistenceofsuchStandardsandPublicationsshallnotinanyrespectprecludeanymemberornonmemberofJEDECorIPCfrommanufacturingorsellingproductsnotconforming
tosuchStandardsandPublications,norshalltheexistenceofsuchStandardsandPublicationsprecludetheirvoluntaryusebythoseotherthanJEDECandIPCmembers,whetherthestandardistobeusedeitherdomestically
orinternationally.
RecommendedStandardsandPublicationsareadoptedbyJEDECand
IPCwithoutregardtowhethertheiradoptionmayinvolvepatentsonarticles,materials,orprocesses.Bysuchaction,JEDECandIPCdonotassumeanyliabilitytoanypatentowner,nordotheyassumeanyobligationwhatever
topartiesadoptingtheRecommendedStandardorPublication.Usersarealsowhollyresponsibleforprotectingthemselvesagainstallclaimsofliabilitiesforpatentinfringement.
ThematerialinthisjointstandardwasdevelopedbytheJEDECJC-14.1CommitteeonReliabilityTestMethodsforPackagedDevicesandtheIPCPlasticChipCarrierCrackingTaskGroup(B-10a)
ForTechnicalInformationContact:
JEDEC
SolidStateTechnologyAssociation3103North10thStreet,Suite240-SArlington,VA22201-2107
Tel703907.0026
Fax703907.7501
IPC
3000LakesideDrive,Suite105NBannockburn,Illinois
60015-1249
Tel847615.7100
Fax847615.7105
PleaseusetheStandardImprovementFormshownattheendofthisdocument.
©Copyright2018.JEDECSolidStateTechnologyAssociation,Arlington,Virginia,andIPC,Bannockburn,Illinois,USA.AllrightsreservedunderbothinternationalandPan-Americancopyrightconventions.Anycopying,scanningorotherreproductionofthesematerialswithoutthepriorwrittenconsentofthecopyrightholderisstrictlyprohibitedandconstitutesinfringementundertheCopyrightLawoftheUnitedStates.
IPC/JEDECJ-STD-033D
Handling,Packing,ShippingandUseofMoisture,Reflow,andProcessSensitiveDevices
AjointstandarddevelopedbytheJEDECJC-14.1CommitteeonReliabilityTestMethodsforPackagedDevicesandtheB-10aPlasticChipCarrierCrackingTaskGroupofIPC
Supersedes:
IPC/JEDECJ-STD-033C-1-
August2014
IPC/JEDECJ-STD-033C-
February2012IPC/JEDECJ-STD-033B.1
includesAmendment1-January2007
IPC/JEDECJ-STD-033B-
October2005
Usersofthispublicationareencouragedtoparticipateinthedevelopmentoffuturerevisions.
Contact:
IPC/JEDECJ-STD-033A-
July2002
IPC/JEDECJ-STD-033-
April1999JEDECJEP124
IPC-SM-786A-January1995
IPC-SM-786-December1990
JEDEC
SolidStateTechnologyAssociation3103North10thStreet,Suite240-SArlington,VA22201-2107
Tel703907.0026
Fax703907.7501
IPC
3000LakesideDrive,Suite105NBannockburn,Illinois
60015-1249
Tel847615.7100
Fax847615.7105
ThisPageIntentionallyLeftBlank
April2018 IPC/JEDECJ-STD-033D
Acknowledgment
Anydocumentinvolvingacomplextechnologydrawsmaterialfromavastnumberofsourcesacrossmanycontinents.WhiletheprincipalmembersofthePlasticChipCarrierCrackingTaskGroup(B-10a)ofthePackagedElectronicComponentsCommittee(B-10)areshownbelow,itisnotpossibletoincludeallofthosewhoassistedintheevolutionofthisstandard.Toeachofthem,themembersoftheIPCextendtheirgratitude.
PlasticChipCarrierCrackingTaskGroup
Chairman
StevenR.MartellNordsonSonoscan
JEDECJC14.1Committee
ChairmanIfeHsu
IntelCorporation
JointMoistureClassificationWorkingGroupMembers
JosephKane,BAESystemsPlatformSolutions
MudasirAhmad,CiscoRobertDiMaggio,ClariantMarkReese,ClariantFrancisClasse,Cypress
ChrisBrigham,EvansAnalyticalGroupMarkBurns,GlobalFoundries
ShiDanBing,HuaweiGuoFujan,HuaweiJiaoHuifang,Huawei
RussLewis,Hewlett-PackardCurtisGrosskopf,IBMCorporationAndreasPreussger,Infineon
DennisCerney,InfineonIfeHsu,IntelCorporationAlanLucero,IntelGautamVerma,Intel
KenMcGhee,JEDECPerryKeller,KeysightAshKumar,MicrochipDongieXie,Nvidia
BobKnoell,NXPSemiconductorsNicholasLycoudes,NXP
Semiconductors
StevanHunter,OnSemiMumtazBora,Peregrine
Semiconductor
RichardIodice,RaytheonCompanyJinhwanKim,Samsung
HeonSangLim,SamsungMianQuddus,Samsung
MichelleOgihara,SeikaMachineryInc.StevenMartell,SonoscanInc.
JamesBerry,TexasInstrumentsLarryTing,TexasInstruments
StephenTisdale,TisdaleEnvironmentalConsulting
BruceHughes,USArmy
Additionally,wewouldliketoexpressourappreciationtotheJEITAmembersfortheirsupportinimprovingJ-STD-033revD.
InMemorium
TheJointCommitteewouldliketoespeciallyacknowledgeJackT.McCullenandRichardL.ShookfortheiroutstandingcontributionsandleadershipinthedevelopmentofJ-STD-033.
iii
ThisPageIntentionallyLeftBlank
April2018 IPC/JEDECJ-STD-033D
TableofContents
FOREWORD 1
Purpose 1
Scope 1
AssemblyProcesses 1
MassReflow 1
LocalizedHeating 1
SocketedDevices 1
Point-to-PointSoldering 1
AqueousCleaning 1
Reliability 2
TermsandDefinitions 2
ActiveDesiccant 2
BarCodeLabel 2
BulkReflow 2
Carrier 2
Desiccant 2
FloorLife 2
HumidityIndicatorCard(HIC) 2
Manufacturer’sExposureTime(MET) 2
Moisture-BarrierBag(MBB) 2
Moisture-SensitiveIdentification(MSID) 2
Moisture-SensitivityLevel(MSL) 2
Rework 2
Process-SensitivityLevel(PSL) 2
ShelfLife(ofadeviceinasealedMBB) 2
SMD 3
SolderReflow 3
WaterVaporTransmissionRate(WVTR) 3
APPLICABLEDOCUMENTS(Normative) 3
AmericanSocietyforTestingandMaterials(ASTM) 3
ElectronicIndustriesAlliance(ECIA,JEDEC) 3
IPCStandards 3
JointIndustryStandards 3
DepartmentofDefense 3
DRYPACKING 3
Requirements 3
DryingofSMDPackagesandCarrierMaterialsBeforeBeingSealedinMBBs 4
DryingRequirements-Levels2a-5a 4
DryingRequirementsforCarrierMaterials 4
DryingRequirements 4
ExcessTimeBetweenBakeandBag 4
DryPack 4
Description 4
Materials 4
Labels 6
MoistureBarrierBagSealing 7
Dry-PackPrecautions 7
ShelfLife 8
DRYING 8
PostExposuretoFactoryAmbient 10
AnyDurationExposure 10
ShortDurationExposure 10
GeneralConsiderationsforBaking 11
HighTemperatureCarriers 11
LowTemperatureCarriers 11
PaperandPlasticContainerItems 11
BakeoutTimes 11
ESDProtection 11
ReuseofCarriers 11
SolderabilityLimitations 11
USE 11
IncomingBagInspection 11
UponReceipt 11
DeviceInspection 12
FloorLife 12
SafeStorage 12
DryPack 12
ShelfLife 12
DryAtmosphereCabinet 12
Reflow 12
OpenedMBB 12
ReflowTemperatureExtremes 12
AdditionalThermalProfileParameters 13
MultipleReflow 13
MaximumReflowPasses 13
DryingIndicators 13
ExcessHumidityinDryPack 13
FloorLifeorAmbientTemperature/HumidityExceeded.135.5.3 Level6SMDPackages 13
BOARDREWORK 13
DeviceRemoval,ReworkandRemount 13
RemovalforFailureAnalysis 14
RemovalandRemount 14
BakingofPopulatedBoards 14
v
IPC/JEDECJ-STD-033D April2018
DERATINGDUETOFACTORY
ENVIRONMENTALCONDITIONS 14
APPENDIXA TestMethodforReversible(Type1)
RHSpotsonaHumidityIndictorCard(HIC)usedwithElectronicDevicePackaging 16
APPENDIXB DerivationofBakeTables 17
APPENDIXC DesiccantUnitAbsorptionCapacity
TestMethodforVerification 18
APPENDIXD ChangesinJ-STD-033D 19
Figures
Figure3-1 TypicalDry-PackConfigurationforMoisture-
SensitiveSMDPackagesinShippingTubes 4
Figure3-2AHumidityIndicatorCard(HIC)–Type1 5
Figure3-2BHumidityIndicatorCard(HIC)–Type2 5
Figure3-3 Moisture-SensitiveIdentificationLabel
(Examples) 6
Figure3-4ACautionLabel(ExampleswithMSLonly) 7
Figure3-4BCautionLabel(ExampleswithMSLandPSL) 7
Figure3-5 MBBwithNoEvacuation(Example) 8
Figure3-6 MBBwithRecommendedLightAirEvacuation(Example) 8
Figure3-7 MBBwithTooMuch(Full)Evacuation
(Example) 8
FigureA-1 PhotoofTestingApparatus 16
Tables
Table3-1 Dry-PackingRequirements 4
Table3-2 TypicalReversible(Type1)HICSpot
Compliance 6
Table4-1 ReferenceConditionsforDryingMountedorUnmountedSMDPackages 9
Table4-2 SupplierBake:DefaultBakingTimesUsed
PriortoDryPack 10
Table4-3 ResettingorPausingtheFloor-LifeClock
atUserSite 10
Table5-1 MoistureClassificationLevel(MSL)and
FloorLifeperJ-STD-020 12
Table7-1 RecommendedEquivalentTotalFloor
Life(days)@20°C,25°C&30°C,35°CForICswithNovolac,Biphenyland
MultifunctionalEpoxies(Reflowatsametemperatureatwhichthedevicewasclassified)
MaximumPercentRelativeHumidity 15
vi
April2018 IPC/JEDECJ-STD-033D
Handling,Packing,ShippingandUseofMoisture,Reflow,
andProcessSensitiveDevices
FOREWORD
Theadventofsurfacemountdevices(SMDs)introducedanewclassofqualityandreliabilityconcernsregardingdamagesuchas‘‘cracksanddelamination’’fromthesolderreflowprocess.Thisdocumentdescribesthestandardizedlevelsoffloor-lifeexposureformoisture/reflowsensitiveSMDsalongwiththehandling,packingandshippingrequirementsnecessarytoavoidmoisture/reflowrelatedfailures.CompaniondocumentsJ-STD-020,J-STD-075andJEP113definetheclassificationprocedureandthelabelingrequirements,respectively.
Formoisturesensitivity,moisturefromatmospherichumidityenterspermeablepackagingmaterialsbydiffusion.AssemblyprocessesusedtosolderSMDstoprintedcircuitboards(PCBs)exposetheentirepackagebodytotemperatureshigherthan200°C.Duringsolderreflow,thecombinationofrapidmoistureexpansion,materialsmismatch,andmaterialinterfacedegradationcanresultincrackingand/ordelaminationofcriticalinterfaceswithinthedevice.
Typicalsolderreflowprocessesofconcernforalldevicesareconvection,convection/IR,infrared(IR),vaporphase(VPR),hotair
reworktools,andwavesolder,includingfullimmersion.
Non-semiconductordevicesmayexhibitadditionalprocesssensitivitiesbeyondmoisturesensitivitysuchasthermalsensitivity,
fluxsensitivityorcleaningprocesssensitivity.
PurposeThepurposeofthisdocumentistoprovidemanufacturersanduserswithstandardizedmethodsforhandling,packing,shipping,anduseofmoisture/reflowandprocesssensitivedevicesthathavebeenclassifiedtothelevelsdefinedinJ-STD-020orJ-STD-075.Thesemethodsareprovidedtoavoiddamagefrommoistureabsorptionandexposuretosolderreflowtemperaturesthatcanresultinyieldandreliabilitydegradation.Byusingtheseprocedures,safeanddamage-freereflowcanbeachieved.Thedry-packingprocessdefinedhereinprovidesaminimumshelflifeof12monthsfromthesealdate.
ScopeThisstandardappliestoalldevicessubjectedtobulksolderreflowprocessesduringPCBassembly,includingplasticencapsulatedpackages,processsensitivedevicesandothermoisturesensitivedevicesmadewithmoisture-permeablematerials(epoxies,silicones,etc.)thatareexposedtotheambientair.
AssemblyProcesses
MassReflowThisstandardappliestobulksolderreflowassemblybyconvection,convection/IR,infrared(IR),andvaporphase(VPR)processes.Itdoesnotapplytobulksolderreflowprocessesthatimmersethedevicebodiesinmoltensolder(e.g.,wavesolderingbottommounteddevices).SuchprocessesarenotallowedformanySMDsandarenotcoveredbythedevicequalificationsstandardsusedasabasisforthisdocument.
LocalizedHeatingThisstandardalsoappliestomoisture/reflowsensitiveSMDpackagesthatareremovedorattached
singlybylocalambientheating,i.e.,‘‘hotairrework.’’SeeClause6.
SocketedDevices
ThisstandarddoesnotapplytoSMDpackagesthataresocketedandnotexposedtosolderreflowtemperaturesduringeitherbulkrefloworreworkofadjacentdevices.SuchSMDpackagesarenotatriskanddonotrequiremoistureprecautionaryhandling.
Point-to-PointSolderingThisstandarddoesnotapplytoSMDpackagesinwhichonlytheleadsareheatedtoreflowthesolder,e.g.,hand-soldering,hotbarattachofgullwingleads,andthroughholebywavesoldering.Theheatabsorbedbythepackagebodyfromsuchoperationsistypicallymuchlowerthanforbulksurfacemountrefloworhotairreworkandmoistureprecautionarymeasuresaretypicallynotneeded.
AqueousCleaningFornon-cavitySMDstypicalshorttermaqueouscleaningprocesseswillnotimpactthefloorlife
(internalmoisturecontent).Specialconsiderationshouldbegiventonon-hermeticcavitypackages.
1
IPC/JEDECJ-STD-033D April2018
ReliabilityThemethodssetforthinthisspecificationensurethatanadequateSMDpackagereliabilitycanbeachievedduringandafterthePCBassemblyoperation,whentheSMDpackagesareevaluatedandverifiedbyJ-STD-020,J-STD-075,and/orbyJESD22-A113plusenvironmentalreliabilitytesting.
Note:Thisspecificationdoesnotaddressorensuresolderjointreliabilityofexternalinterconnectsforattacheddevices.
TermsandDefinitions
ActiveDesiccantDesiccantthatiseitherfresh(new)orhasbeenbakedaccordingtothemanufacturer’srecommendations
torenewittooriginalspecifications.
BarCodeLabelAlabelthatincludesinformationinacodeconsistingofparallelbarsandspacesora2-Dmatrixformat.
Note:Forthepurposeofthisstandard,thebarcodelabelisonthelowest-levelshippingcontainerandincludesinformationthat
describestheproduct,e.g.,partnumber,quantity,lotinformation,supplieridentification,andmoisture-sensitivitylevel.
BulkReflowReflowofmultipledeviceswithsimultaneousattachmentbyaninfrared(IR),convection/IR,convection,orvaporphasereflow(VPR)process.
Carrier Apockettape,tray,tube,orothercontainerusedtostoreandtransportpackageddevices.
DesiccantAnabsorbentmaterialusedtomaintainalowrelativehumidity.
FloorLifeTheallowabletimeperiodafterremovalofmoisture-sensitivedevicesfromamoisture-barrierbag,drystorage,ordrybakeandbeforethesolderprocess.
HumidityIndicatorCard(HIC)Acardonwhichamoisture-sensitivechemicalisappliedasaspotthatwillmakeasignificant,
perceptiblechangewhentheindicatedrelativehumidityisexceeded.
Note1:TwotypesofHICshavebeendefined.
Type1HIC(reversible)Forreversiblespotsthechangeistemporaryandoccursasachangeincolor(hue),typicallyfromblue(dry)topink(wet).Aperceptiblechangewillbeseenifthehumiditythresholdisonlymomentarilysurpassed.
Type2HIC(nonreversible)Fornonreversiblespotsthechangeisnottemporaryandcanbeaspotcolormigrationoutsideofthespotborderorsomeothernonreversibleindicator.AnonreversibleHICincludesatleasta60%RHindicatorspot,butcanhaveothernonreversibleRH%indicatorsthatdonotrevertafterexposuretoahumiditythreshold.
Note2:TheHICispackedinsidethemoisture-barrierbag,alongwithadesiccant,toaidindeterminingthelevelofmoisturetowhichthemoisture-sensitivedeviceshavebeensubjected.Type1andType2HICsthathavebeenexposedto60%orgreaterRHwillnolongerbeconsideredaccurate.
Manufacturer’sExposureTime(MET)Themaximumcumulativetimeafterbakethatdevicesmaybeexposedtoambientconditionspriortoshipmenttoenduser.
Moisture-BarrierBag(MBB)Abagdesignedtorestrictthetransmissionofwatervaporandusedtopackmoisture-sensitivedevices.
Moisture-SensitiveIdentification(MSID) Asymbolindicatingthatthecontentsaremoisture-sensitive.
Moisture-SensitivityLevel(MSL) Aratingindicatingadevice’ssusceptibilitytodamageduetoabsorbedmoisturewhen
subjectedtoreflowsolderingasdefinedinJ-STD-020.
ReworkTheremovalofadeviceforscrap,reuse,orfailureanalysis;thereplacementofanattacheddevice;ortheheatingandrepositioningofapreviouslyattacheddevice.
Process-SensitivityLevel(PSL)Aratingusedtoidentifyadevicethatissolder-process-sensitivebecausethedevice
cannotbeusedinoneormoreofthebasesolderprocessconditionsdefinedinJ-STD-075.
ShelfLife(ofadeviceinasealedMBB)Theallowabletimethatadry-packedmoistureorreflow-sensitivedevicecanbe
storedinanunopenedmoisture-barrierbag(MBB).
2
April2018 IPC/JEDECJ-STD-033D
SMDSurfacemountdevice.
Note:Forthepurposeofthisstandard,SMDisrestrictedtoincludeonlyplastic-encapsulatedSMDsandotherpackagesmadewithmoisture-permeablematerials.
SolderReflowAsolderattachmentprocessinwhichpreviouslyappliedsolderorsolderpasteismeltedtoattachadevicetoaprintedcircuitboard.
WaterVaporTransmissionRate(WVTR)Ameasureofthepermeabilityofplasticfilmormetallizedplasticfilmmaterial
tomoisture.
APPLICABLEDOCUMENTS(Normative)
AmericanSocietyforTestingandMaterials(ASTM)1
ASTMF1249StandardTestMethodforWaterVaporTransmissionRateThroughPlasticFilmandSheetingUsingaModulatedInfraredSensor.
ASTMF392StandardTestMethodforFlexDurabilityofFlexibleBarrierMaterials
ElectronicIndustriesAlliance(ECIA,ESDA,JEDEC)ANSI/ESDS541PackagingMaterialforESDSensitiveItems2
ANSI/ESDS541PackagingMaterialStandardsforESDSensitiveItems
JESD625RequirementsforHandlingElectrostaticDischargeSensitive(ESD)Devices
JEP160LongTermStorageGuidelinesforElectronicSolidStateWafers,Dice,andDevices
JESD22-A113PreconditioningofNon-hermeticSurfaceMountDevicesPriortoReliabilityTesting
JESD22-A120TestMethodfortheMeasurementofMoistureDiffusivityandWaterSolubilityinOrganicMaterialsUsedinIntegratedCircuits
IPCStandards3
IPC-7711/21Rework,ModificationandRepairofElectronicAssemblies
JointIndustryStandards4
J-STD-020Moisture/ReflowSensitivityClassificationforNon-hermeticSolidStateSurfaceMountDevicesJ-STD-075ClassificationofNon-ICElectronicComponentsforAssemblyProcesses
DepartmentofDefense5
MIL-PRF-81705TypeI-BarrierMaterialsFlexible.Electrostatic-free.HeatSealable
MIL-D-3464TypeII-Desiccant,Activated,Bagged,PackagingUseandStaticDehumidification
DRYPACKING
RequirementsDry-packingrequirementsforthevariousmoisturesensitivitylevelsareshowninTable3-1.ThelevelsaredeterminedperJ-STD-020,J-STD-075,and/orperJESD22-A113plusreliabilitytesting.AsaminimumallmaterialsusedindrypackingshouldconformtoANSI/ESDS541.
\h
;;
\h
\h
;;
\h
\h
/qsSearch.aspx
3
IPC/JEDECJ-STD-033D April2018
Table3-1Dry-PackingRequirements
Level
DryBeforeBag
MBBWithHIC
Desiccant
MSIDLabel
CautionLabel
1
Optional
Optional
Optional
NotRequired
NotRequiredifclassifiedat220ºC–225ºCRequired*ifclassifiedatotherthan220ºC–225ºC
2
Optional
Required
Required
Required
Required
2a-5a
Required
Required
Required
Required
Required
6
Optional
Optional
Optional
Required
Required
SocketOnly
NotApplicable
NotApplicable
NotApplicable
NotRequired
NotRequired
Note:*A‘‘Caution’’labelisnotrequirediflevelandreflowtemperaturearegiven,inhumanreadableform,onthebarcodelabelattachedtothelowestlevel
shippingcontainer.
DryingofSMDPackagesandCarrierMaterialsBeforeBeingSealedinMBBs
DryingRequirements-Levels2a-5aSMDpackagesclassifiedatLevels2athrough5amustbedried(seeClause4.)priortobeingsealedinMBBs.TheperiodbetweendryingandsealingmustnotexceedtheMETlessthetimeallowedfordistributorstoopenthebagsandrepackparts.Ifthesupplier’sactualMETismorethanthedefault24hours,thentheactualMETmustbeused.IfthedistributorpracticeistorepacktheMBBswithactivedesiccant,thenthistimedoesnotneedtobesubtractedfromtheMET.
DryingRequirementsforCarrierMaterialsCarriermaterials,suchastrays,tubes,reels,etc.,thatareplacedintheMBBcanaffectthemoisturelevelwithintheMBB.Therefore,theeffectofthesematerialsmustbecompensatedforbybakingor,ifrequired,addingadditionaldesiccantintheMBBtoensurethecalculatedshelflifeoftheSMDpackages.
DryingRequirementsSuppliersmayusethedryingeffectofnormalin-lineprocessessuchaspostmoldcure,markingcure,andburn-intoreducethebaketime.Anequivalencyevaluationisrecommendedtoensurethathightemperatureprocessingmaintainsmoistureweightgaintoanacceptablelevel.ThetotalweightgainfortheSMDpackageatthetimeitissealedintheMBBmustnotexceedthemoisturegainofthatpackagestartingdryandthenbeingexposedto30°C/60%RHforMEThours(lessthetimefordistributors).
ExcessTimeBetweenBakeandBagIftheallowabletimebetweenbakeandbagisexceeded,theSMDpackagesmustbedriedagainperClause4.
DryPack
J-STD-033D-3-1
MBB
DesiccantPouches
HIC
FoamEndCap
4
3
2
1
DescriptionDrypackconsistsofdesiccantmaterialandaHumidityIndicatorCard(HIC)sealedwiththeSMDpackagesinsideaMoistureBarrierBag(MBB).Arepresentativedry-packconfigurationisshowninFigure3-1.
Materials
MoistureBarrierBag(MBB)ThemoisturebarrierbagshallmeetMIL-PRF-81705,TYPEIrequirementsforflexibility,ESDprotection,mechanicalstrength,andpunctureresistance.Thebagsshallbeheatsealable.TheWaterVaporTransmissionRate(WVTR)shallbe
≤0.0310g/m2[0.002g/100in2]in24hoursat40°Cafterflextestingper
condition‘‘E’’ASTMF392.TheWVTRismeasuredusingASTMF1249.
DesiccantThedesiccantmaterialshallmeetMIL-D-3464,TYPEII.Desiccantshallbedustless,non-corrosive,andabsorbenttoamountsspecifiedinthestandard.Desiccanthasaverylimitedfloorlifeandshouldbestoredandhandledperthemanufacturer’srecommendation
priortoinsertionintheMBB.Thedesiccantmaterialshallbepackagedinmoisturepermeablebagsorpouches.Theamountofdesiccantused,permoisturebarrierbag,shallbebasedonthebagsurfaceareaandWVTRinordertolimittheinteriorrelativehumidityintheMBB,attheendofthecalculatedshelflife,tolessthan10%at25°C.
Figure3-1TypicalDry-PackConfigurationforMoisture-SensitiveSMDPackagesinShippingTubes
4
April2018 IPC/JEDECJ-STD-033D
Forcomparisonbetweenvariousdesiccanttypes,militaryspecificationsadoptedthe‘‘UNIT’’asthebasicunitofmeasureofquantityfordesiccantmaterial.AUNITofdesiccantisdefinedastheamountthatwillabsorbaminimumof2.85gofwatervaporat20%RHand25°C.
DesiccantQuantityCalculation
Whenthedesiccantcapacityat10%RHand25°Cisknown,thefollowingequationshouldbeused:
U=(0.304*M*WVTR*A)/D
Where:
U=AmountofdesiccantinUNITS
0.304=Averagenumberofdayspermonth/100in2(30.4/100)M=Shelflifedesiredinmonths(see3.3.6forshelflife)
WVTR=Watervaportransmissionrateingrams/m2[grams/100in2]in24hrsA=TotalexposedsurfaceareaoftheMBBinsquaredecimeters(squareinches)
D=Theamountofwateringrams,thataUNITofdesiccantwillabsorbat10%RHand25°C
Whenthedesiccantcapacityat10%RHand25°CisnotknownaconservativevalueofD=1.40canbeused.
Note1:Ifitisdesiredtominimizetheamountofdesiccantusedfordry-packinglevel2devicesavalueofDbasedontheamountofwateringrams,thataUNITofdesiccantwillabsorbat60%RHand25°Cmustbeusedintheformula.Thisvalueshouldtobeobtainedfromthedesiccantmanufacturer.WhenthisoptionisuseditmustbeverifiedthatwhenthedevicewasclassifiedperJ-STD-020itmusthaveachievedfullsaturationduringmoisturesoak.
Note2:Nomoisture-absorbingmaterial(e.g.,trays,tubes,reels,foamendcaps)shouldbeplacedinthedrybagwithoutlowtemperaturebaking.Anysuchmaterialthatisincludedincreasestheamountofdesiccantneededtomeetthecalculatedshelflife(see5.3.1)byanamountbasedonthemoisturecontentofthematerial.Thiscanbedeterminedbyweighingarepresentativequantityofmaterialknowntobeatequilibriumwiththemanufacturingenvironment,bakingtoanewconstantweight,andsubtractingthefinalfromtheinitialweight.
J-STD-033D-3-2B
J-STD-033D-3-2A
Donotputthiscardintoabagif60%isoverrun
5%
10%
PARTS
Bakepartsif10%isNOT
blueand5%ispink
Bakeparts
if60%overrunborder
REVERSIBLESPOTS
LEVEL2A-5A
60%
2PARTS
HUMIDITYINDICATOR
ComplieswithIPC/JEDECJ-STD-033
TYPE2NONREVERSIBLESPOT
LEVEL
Donotputthiscardintoabagif60%ispink
5%
10%
PARTS
Bakepartsif10%isNOT
blueand5%ispink
Bakeparts
if60%NOTblue
REVERSIBLESPOTS
LEVEL2A-5A
60%
2PARTS
HUMIDITYINDICATOR
ComplieswithIPC/JEDECJ-STD-033
TYPE1REVERSIBLESPOTS
LEVEL
LotNumber
LotNumber
AdditionalUNIT(s)ofdesiccant,basedon10%RH@25°C,mustbeaddedtoabsorbtheamountofwater,ingrams,egressedfromthepackingmaterials(dunnage)afterbaking.
ManufacturerIdentification
ManufacturerIdentification
Figure3-2AHumidityIndicatorCard(HIC)–Type1 Figure3-2BHumidityIndicatorCard(HIC)–Type2
5
IPC/JEDECJ-STD-033D April2018
DesiccantHandlingandStorageDesiccantcapacitydecreasesrapidlywhenexposedto30°C/60%RH.Thereforethedesiccantshouldremaininthemanufacturer’scontainerorstoredinadrycabinetat<5%RHuntiluse.Whendrypacking,thedesiccantshallberemovedfromthestoragecontainerjustpriortoplacingitintotheMBBandsealingtheMBB.AppendixCprovidesamethodtovalidatethedesiccantunitabsorptioncapacity.
HumidityIndicatorCards(HIC)Type1(Reversible)andType2(Nonreversible)Ataminimum,theHICshallhavethree
(3)colorspotswithsensitivityvaluesof5%,10%RHand60%RH.AnexampleType1HICiss
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 文化活动的保安工作探讨计划
- 基于项目的美术教学计划
- 西南医科大学《灾害卫生学》2022-2023学年第一学期期末试卷
- 西南交通大学《数据结构与算法》2022-2023学年第一学期期末试卷
- 西华师范大学《日语二外》2021-2022学年第一学期期末试卷
- 2024年01月11141工程经济与管理期末试题答案
- 西昌学院《规划设计》2023-2024学年第一学期期末试卷
- 西北大学《网页设计》2023-2024学年第一学期期末试卷
- 西北大学《近代物理实验》2022-2023学年第一学期期末试卷
- 探究暖宝宝的发热原理说课稿-2023-2024学年九年级化学人教版下册
- 2024全球体育行业调研报告(第八期)-渐入佳境
- 事业单位考试职业能力倾向测验(综合管理类A类)试题与参考答案(2024年)
- 血液透析室医院感染控制与管理
- 换热站维保合同范例
- 急诊与灾难医学(广西中医药大学)知到智慧树章节答案
- 2024-2025学年上海市普陀区六年级(上)期中语文试卷
- 2024年新款消防灭火器购销协议
- 深圳大学《计算机网络与应用》2022-2023学年期末试卷
- 职业培训师教学技能手册
- 南京信息工程大学《自然语言处理》2023-2024学年期末试卷
- 临沂大学《信息可视化设计》2021-2022学年第一学期期末试卷
评论
0/150
提交评论