ElectricPowerIndustryStandardofthePeople'sRepubKcofChina
DL/T1341—2014
TechnicalGuideforLiveWorkingon
±660kVDCTransmissionLine
IssueDate:March18,2014
ImplementationDate:August1,2014
IssuedbyNationalEnergyAdministrationofthePeople'sRepublicofChina
setofelectrostaticprotectiveclothingorconductiveclothing.Ifitisnecessarytodisconnectthedirectlygroundedoverheadgroundwiresfromtheground,theoverheadgroundwiresshallbehungwithearthingcablesbeforemaintenance.
Beforeoverhaulinginthemiddleoftheoverheadgroundwirespan,inordertoensurehis/hersafety,theworkershallcheckwhethertheverticaldistancebetweenhim/herandtheliveconductorsbelowmeetstheminimumworkingdistancerequirementsaftertheoverheadgroundwireintheworklocationisloadedbyhim/her,andwhetherthemechanicalstrengthoftheoverheadgroundwiremeetsrelevantrequirements.
Whenworkingontheuni-polarpower-offside(theotherpoleisrunning),theworkershallwearafullsetofelectrostaticprotectiveclothingorconductiveclothing.
Whenusinginsulatingropestotransferlargemetalobjects,theworkeratgroundpotentialoronthetowershallgroundthemetalobjectsbeforetouchingthem.
Withregardtolargemetalobjects(e.g.automobiles,etc.)insulatedfromthegroundandplacednearstrongelectricfields,attentionshallbepaidtoprotectingpeoplefrominducedelectricalinjury.Themetalobjectsmustbegroundedbeforetheycanbetouched.
5.4Potentialtransfer
Theequipotentialworkershallobtainpermissionfromthepersoninchargeoftheworkbeforepotentialtransferandshallnotlosetheprotectionofthesafetybelt.
ForpotentialtransferofDCtransmissionlines,thepotentialrodshouldbeused,whichshallbeinreliablecontactwithliveconductors.Beforeenteringequipotential,theworkershallcontactthepotentialrodquicklywiththeliveconductorsatadistanceofabout0.4mfromthem.Whenleavingequipotential,theworkershallcontactthepotentialrodwiththeliveconductorsfirst,andthenwithdrawthepotentialrodquicklyafterleavingtheliveconductors0.4maway.
Duringpotentialtransfer,theactionshallbesmooth,accurateandfast.
6Enterorleaveequipotential
Enterorleaveequipotentialonasuspensiontower
Whenenteringorleavingequipotentialonasuspensiontower,theworkershallnotenterorleaveequipotentialverticallyfromthecrossarmsoralongtheinsulatorstrings.Thehangingbasket(hangingchairandhangingladder)method,theinsulatingflexibleladdermethodandothermethodsmaybeusedtoenterandleaveequipotential.
Whentheworkerentersorleavesequipotential,alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheworkerandtheearthingconductorsandtheliveconductorsshallmeettherequirementsofTables3andTable4.
Thehangingbaskets(hangingchairsandhangingladders)shallbestablysuspendedbyinsulatingslings,andthemovingspeedshallbestrictlycontrolledbyinsulatingpulleysetstoachieveauniformandslowspeed.Thelengthoftheinsulatingslingsforfixingshallbeaccuratelycalculatedoractuallymeasuredtoensurethatthehighestpartofthehumanbodyshallnotexceedtheupperedgeofthegradingringontheconductorsidewhentheworkerentersorleavesequipotential.
Enterorleaveequipotentialonatensiontower
Whenenteringorleavingequipotentialonatensiontower,theworkermayenterorleaveequipotentialalonghorizontaltensioninsulatorstringsorviaothermethods.
Whentheworkermovesalongthehorizontaltensioninsulatorstrings,thepositionsofhis/herhandsandfeetmustbekeptconsistent,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyandtoolsshallmeettherequirementsofTable5.
Theworker'ssafetyprotectionropeshallbetiedtotheinsulatorstringheldbyhis/herhandsandshallmovesynchronouslywithhim/her.
Whenenteringorleavingequipotential,theworkershalltransferpotentialwhenmovingtoadistanceofabout0.4m(2~3insulators)fromtheliveconductorsbeforecarryingoutsubsequentoperations.
Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheworkerandtheearthingconductorsandtheliveconductors,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyortoolsshallmeettherequirementsofTable5.
Mattersneedingattentionatwork
Theworkersshallavoidexcessivebodymovementsduringliveworking.
Insulatingtoolsshallbeusedtotransferarticlesbetweentheequipotentialworkerandthegroundpotentialworker.TheeffectivelengthoftheinsulatingtoolsshallmeettherequirementsofTable2.
Theconductiveclothingshallbefreefromdamageandholes,andallpartsofitshallbeconnectedwellandreliably.Whendamageandburrsarefound,itshallberepairedintime,anditcanbeusedonlyafterpassingthetest.
Beforetheinsulatingtoolsareused,aninsulationresistancetestershallbeusedtoconductsegmentedinsulationtests.Thewidthofthemeasuringelectrodesis2cm,anditisrequiredthattheinsulationresistancebetweenevery2cmofmeasuringelectrodesshallnotbelessthan700MQ.
Theinsulatingtoolsshallbeprotectedfrommoistureandsurfacedamageanddirtwhenused.Theinsulatingtoolstobeusedshallbeplacedonclean,dryandmoisture-proofpads.Whenfounddampenedorsurface-damagedorsurface-dirty,theyshallbehandledintimeandcanbeusedonlyafterpassingthetest.
Duringthework,bearingtoolsshallbefixedandreliableandhavebackupprotection.
Ifdeterioratedorlowresistanceinsulatorsarefoundduringlivetestingofinsulators,theyshallberetested2-3timestoavoidmisjudgment.
Whenthefirstinsulatornearthecrossarmisdismantledorinstalled,itmustbeshort-circuitedbeforeoperation.
Testoftools,devicesandequipment
Thedesignofliveworkingtools,devicesandequipmentshallconformtotherequirementsofGB/T18037.
Conductiveclothing,insulatingropes,insulatingrods,insulatorholders,etc.,shallpasstypetestsandleavingfactorytestsinaccordancewiththerequirementsofGB/T6568,GB/T13035,GB13398,DL/T463,DL/T878.
Thetools,devicesandequipmentshallbesubjectedtoelectricaltestsandmechanicaltestsonaregularbasisaccordingtothetestmethodsofDL/T976.Thetestcyclesareasfollows:
electricaltests.Preventivetestsshallbeconductedonceayear,andinspectiontestsshallbeconductedonceayear,andtheintervalbetweentwotestsshallbehalfayear.
mechanicaltests.Preventivetestsshallbeconductedonceeverytwoyearsforinsulatingtoolsandonceeveryyearformetaltools.
Preventivetests
DCwithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe4.8m;thewithstandvoltageshallbe755kV;thetimeshallbe3min.Itisqualifiedifnobreakdown,flashoveroroverheatingoccur.
Switchingimpulsewithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe4.8m;thestandardswitchingimpulsewave(+250|is/2500|is)shallbeapplied;thevoltageamplitudeshallbe1325kV;thetestsampleshallwithstand15times.Itisqualifiedifnobreakdownorflashoveroccur.
Staticloadtest:aloadof1.2timestheweightoftheratedworkingloadshallbeappliedforImin.Itisqualifiedifnodeformationordamageoccur.
Dynamicloadtest:3timesofactualoperationsshallbedonewithaloadof1.0timestheweightoftheratedworkingloadapplied.Itisqualifiedifthetoolsareflexible,portableandfreefromjamming.
Inspectiontests
Theinsulatingtoolshallbedividedintoseveralsectionsforpowerfrequencywithstandvoltagetests.Avoltageof75kVshallbeappliedacrossper300mmoftheinsulatingtoolforImin.Itisqualifiedifnobreakdown,flashoverorheatingoccur.
Thewholesetofconductiveclothingshallbefreeofdamage,holesandburrsintheappearanceinspection,andtheconnectingdevicesofallpartsshallbereliableandintact,withgoodconductionafterconnection.
Transportationandstorageoftools,devicesandequipment
Duringtransportation,theinsulatingtools,devicesandequipmentshallbeputintodedicatedtoolbags,toolboxesortoolvehiclestopreventmoistureanddamage.
Holdersandclampswithlowsurfacehardnessandmetaltools(suchasscrewrods)thatshouldnotbebumpedshallbetransportedwithdedicatedwoodenorleathertoolboxes.Thecapacityofeachboxshallbelimitedtoonesetoftools.Scatteredpartsshallbefixedinthebox.
Theinsulatingtools,devicesandequipmentshallbeprotectedfrommoisture,rainandblazingsunduringtransportationandmaintenance.Plasticbagsmaybeusedasinnerpackagingtransportationbags,andcanvasbagsordedicatedleather(canvas)boxesmaybeusedasouterpackagingtransportationbags.
Theliveworkingtools,devicesandequipmentshallbestoredinadedicateddepot,andthedepotforliveworkingtoolsshallmeettherequirementsofDL/T974.
TableofContents
TOC\o"1-5"\h\z
\o"CurrentDocument"
Foreword II
\o"CurrentDocument"
Scope 1
\o"CurrentDocument"
Normativereferences 1
\o"CurrentDocument"
Termsanddefinitions 2
\o"CurrentDocument"
Generalrequirements 2
\o"CurrentDocument"
Technicalrequirements 4
\o"CurrentDocument"
Enterorleaveequipotential 8
\o"CurrentDocument"
Mattersneedingattentionatwork 9
\o"CurrentDocument"
Testoftools,devicesandequipment 9
\o"CurrentDocument"
Transportationandstorageoftools,devicesandequipment 11
TableofContents
Foreword II
Scope 1
Normativereferences 1
Termsanddefinitions 2
\o"CurrentDocument"
Generalrequirements 2
Technicalrequirements 4
Enterorleaveequipotential 8
Mattersneedingattentionatwork 9
Testoftools,devicesandequipment 9
Transportationandstorageoftools,devicesandequipment 11
TableofContents
TOC\o"1-5"\h\z
Foreword II
Scope 1
Normativereferences 1
Termsanddefinitions 2
Generalrequirements 2
Technicalrequirements 4
Enterorleaveequipotential 8
Mattersneedingattentionatwork 9
Testoftools,devicesandequipment 9
Transportationandstorageoftools,devicesandequipment 11
Foreword
ThisstandardwascompiledinaccordancewiththetaskarrangedbyNoticeoftheNationalEnergyAdministrationonIssuingtheFirstBatchofIndustryStandardFormulati()n(Revisi(m)PlansintheEnergySectorin2010(No.320oftheDepartmentofScienceandTechnologyoftheNationalEnergyAdministration).
ThisstandardwasproposedbytheChinaElectricityCouncil.
ThisstandardwaspreparedbytheNationalTechnicalCommitteeofStandardizationforLiveWorking.
Maindraftingorganizationsofthisstandard:ChinaElectricPowerResearchInstitute,StateGridShandongElectricPowerCompany,andStateGridShanxiElectricPowerCompany.
Maindraftersofthisstandard:LIUKai,HUYi,XIAOBin,LIUHongzheng,LIUTing,MENGHailei,YONGJun,NIUBiao,DONGYanwu,LIUYan,PENGYong,andSUZiming.
Duringtheprocessofimplementingthisstandard,relevantopinionsoradvicecanbefedbacktotheStandardizationManagementCenteroftheChinaElectricityCouncil(No.l,Lane2,BaiguangRoad,Beijing,100761).
TechnicalGuideforLiveWorkingon±660kVDCTransmissionLine
Scope
Thisstandardspecifiesthetechnicalrequirementsandmattersneedingattentionforliveworkingon±660kVDCtransmissionlines,aswellasthetest,transportationandstorageoftheworkingtools.
Thisstandardisapplicabletoliveworkingon±660kVDCtransmissionlinesinareaswithanaltitudeof2000mandbelow.
Normativereferences
Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.
GB/T2900.55ElectrotechnicalTerminology一LiveWorking(eqvIEC60050—651)
GB/T6568ScreenClothesforLiveWorking(GB/T6568—2008,IEC60895:2002,MOD)
GB/T13035LiveWorking一InsulatingRopes
GB13398InsulatingHollowTubesandFoam-FilledTubesandSolidRodsforLiveWorking
GB/T14286LiveWorking—TerminologyforTools,EquipmentandDevices(GB/T14286—2008,IEC60743:2001,MOD)
GB/T18037TechnicalRequirementsandDesignGuideforLiveWorkingTools
GB26859SafetyCodeofElectricPowerIndustry-PartofElectricLines
DL/T463InsulatorHolderforLiveWorking
DL/T876GuideofInsulationCoordinationforLiveWorking
DL/T878TestGuideoftheInsulatingToolforLiveWorking
DL/T966TechnicalGuideforLiveWorkinginTransmissionLine
DL/T974DepotofToolsforLive-Working
DL/T976PreventiveTestCodeofTools,DevicesandEquipmentforLiveWorking
Termsanddefinitions
Forthepurposesofthisstandard,thetermsanddefinitionsgiveninGB/T2900.55andGB/T14286aswellasthefollowingapply.
liveworkingonDCtransmissionline
live-linerepair,maintenance,andreplacementofpartscarriedoutonDCtransmissionlines
potentialrod
metaltoolusedbyanequipotentialworkerwhenenteringorleavingequipotential,inordertoreducetheimpactofdischargearconthehumanbodyandavoidpossibledamagetoconductiveclothingcausedbypulsedcurrent
electricfieldshieldmask
maskmadeofconductivematerials,usedforelectricfieldprotectionoftheworker'sface,andconnectedwithotherscreentoolsforintegraluse
Generalrequirements
Personnelrequirements
Liveworkingworkersshallbeingoodhealthandfreefromphysicalandpsychologicalobstaclesthathinderwork.Theyshallhaveabasicknowledgeofelectricalprinciplesandpowerlines,masterthebasicprinciplesandoperatingmethodsofliveworking,andbefamiliarwiththescopeofapplicationandusingmethodsoftheworkingtools.TheyshallbefamiliarwithGB26859,DL/T966andthisstandard.Theyshallmasteremergencyrescuemethods,especiallytheelectricshockrescue.Theyshallreceivetheoreticalandoperationaltrainingfromspecializedtraininginstitutions,passrelevantexaminationsandholdrelevantcertificates.
Thepersoninchargeofthework(orthesafetyguardian)shallhaveatleast3yearsofactualworkingexperienceinliveworkingonpowertransmissionlines,befamiliarwithequipmentconditions,havecertainorganizationalcapabilityandaccidenthandlingability,andpasstheexaminationafterspecialtraining.
Institutionalrequirements
AccordingtoGB26859andthisstandard.
Meteorologicalrequirements
Liveworkingshallbecarriedoutingoodweather.Incaseofthunder,rain,snowandfog,liveworkingshallnotbecarriedout.Whenthewindforceisgreaterthanlevel5(lOm/s),liveworkingshouldnotbecarriedout.
Ifliveworkingisrequiredinweatherwithrelativehumiditygreaterthan80%,insulatingtoolswithmoisture-proofperformanceshallbeadopted,andthepossibilityofinsulationdegradationoftheinsulatingtoolsunderhighhumidityshallbeconsidered.
Underspecialoremergentconditions,whenemergentlive-linerepairmustbecarriedoutinharshclimate,relevantengineeringandtechnicalpersonnelandallworkingpersonnelshallbeorganizedtofullydiscussandformulatereliablesafetymeasuresaccordingtothesiteclimateandworkingconditions,andtheemergentlive-linerepaircanbecarriedoutonlyaftertheapprovalofthechiefengineeroftheunitortheleaderinchargeofproductionoftheunit.Sufficientlightingfacilitiesshallbeprovidedfornightwork.
Incaseofasuddenchangeofweatherduringliveworking,whichcanendangerpersonalorequipmentsafety,theworkshallbestoppedimmediately.Undertheconditionofensuringpersonalsafety,thenormalworkingconditionsoftheequipmentshallberestoredassoonaspossibleorotherprotectivemeasuresshallbetaken.
Otherrequirements
Fornewliveworkingprojectsthataremorecomplicatedandmoredifficultandnewdevelopedtools,scientifictestsshallbeconductedtoconfirmsafetyandreliability,andsafetymeasuresandoperationprocessplansshallbeestablished,andthetoolscanbeoperatedonequipmentonlyaftertheapprovalofthechiefengineeroftheunitortheleaderinchargeofproductionoftheunit.
Thepersoninchargeofliveworkingshallcontactthedispatcherbeforetheworkstarts,andtheworkcanbestartedonlyaftercontacting.WhenitisnecessarytodisableDCrestartprotectiondevices,thelicenseformalitiesshallbeperformed.Aftertheworkisfinished,reportingtothedispatchershallbedoneintime.Itisstrictlyprohibitedtostoporresumetherestartprotectiondevicesatanappointedtime.
Technicalrequirements
Groundpotentialworking
Whentheworkerworksatgroundpotential,theminimumworkingdistancebetweentheworkeratgroundpotentialonthetowerandtheliveconductorsshallmeettheprovisionsofTable1.
Table1Minimumworkingdistanceofgroundpotentialworking
Altitude/m
Minimumworkingdistance/m
<500
4.2
500~1000
4.5
1000~1500
4.7
1500~2000
5.0
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.
Theminimumeffectiveinsulationlengthofinsulatingtools,devicesandequipmentshallmeettheprovisionsofTable2.
Table2Minimumeffectiveinsulationlengthofinsulatingtools,devicesandequipment
Altitude/m
Minimumworkingdistance/m
<500
5.0
500—1000
5.3
1000~1500
5.6
1500~2000
5.9
Barehandworking
Duringbarehandworking,theminimumworkingdistancebetweentheequipotentialworkerandtheearthingconductorsshallmeettheprovisionsofTable3.
Table3Minimumworkingdistanceofbarehandworking
Altitude/m
Minimumworkingdistance/m
Distancebetweentheequipotentialworkerandthesidetowerframe
Distancebetweentheequipotentialworkerandthetopcrossarmorthetopframe
<500
4.2
4.8
500~1000
4.5
5.1
1000~1500
4.7
5.3
1500~2000
5.0
5.6
Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbeless
than0.5mandshallbeconsideredatwork.
Whentheworkerentersorleavesequipotentialviainsulatingtoolsoralonginsulatorstrings,theminimumcombinedgapshallmeettheprovisionsofTable4.
Table4Minimumcombinedgap
Altitude/m
Minimumcombinedgap/m
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024年度年福建省高校教师资格证之高等教育心理学考前冲刺模拟试卷A卷含答案
- 2024年度年福建省高校教师资格证之高校教师职业道德综合检测试卷B卷含答案
- 2024年闸机系统投资申请报告
- 一年级数学计算题专项练习汇编
- 湖南省永州市高一上学期期末历史试题及解答参考
- 2024商用中央空调全面检修协议
- 2024年临时租车服务协议详案
- 2024年度代理服务协议样本
- 2024年劳动协议格式大全
- 2024老年公寓长期照护服务协议
- 苏教版五年级上册数学试题-第一、二单元 测试卷【含答案】
- 发挥产业工会作用的实施方案
- 科捷物流介绍(中文版)ppt课件
- 军事地形学地形图基本知识
- 2022版义务教育(生物学)课程标准(含2022年修订和新增部分)
- 六年级综合实践活动课件-珍爱生命远离毒品 全国通用(共24张PPT)
- 建设工程竣工消防验收记录表(DOC36页)
- 沉井专项施工方案DOC
- 切削力计算参考模板
- 一年级海洋教育教案
- 聚氨酯硬泡沫配方及计算
评论
0/150
提交评论