F24

RecordNo.44815-2014

DL

ElectricPowerIndustryStandardofthePeople'sRepubKcofChina

DL/T1341—2014

TechnicalGuideforLiveWorkingon

±660kVDCTransmissionLine

IssueDate:March18,2014

ImplementationDate:August1,2014

IssuedbyNationalEnergyAdministrationofthePeople'sRepublicofChina

setofelectrostaticprotectiveclothingorconductiveclothing.Ifitisnecessarytodisconnectthedirectlygroundedoverheadgroundwiresfromtheground,theoverheadgroundwiresshallbehungwithearthingcablesbeforemaintenance.

Beforeoverhaulinginthemiddleoftheoverheadgroundwirespan,inordertoensurehis/hersafety,theworkershallcheckwhethertheverticaldistancebetweenhim/herandtheliveconductorsbelowmeetstheminimumworkingdistancerequirementsaftertheoverheadgroundwireintheworklocationisloadedbyhim/her,andwhetherthemechanicalstrengthoftheoverheadgroundwiremeetsrelevantrequirements.

Whenworkingontheuni-polarpower-offside(theotherpoleisrunning),theworkershallwearafullsetofelectrostaticprotectiveclothingorconductiveclothing.

Whenusinginsulatingropestotransferlargemetalobjects,theworkeratgroundpotentialoronthetowershallgroundthemetalobjectsbeforetouchingthem.

Withregardtolargemetalobjects(e.g.automobiles,etc.)insulatedfromthegroundandplacednearstrongelectricfields,attentionshallbepaidtoprotectingpeoplefrominducedelectricalinjury.Themetalobjectsmustbegroundedbeforetheycanbetouched.

5.4Potentialtransfer

Theequipotentialworkershallobtainpermissionfromthepersoninchargeoftheworkbeforepotentialtransferandshallnotlosetheprotectionofthesafetybelt.

ForpotentialtransferofDCtransmissionlines,thepotentialrodshouldbeused,whichshallbeinreliablecontactwithliveconductors.Beforeenteringequipotential,theworkershallcontactthepotentialrodquicklywiththeliveconductorsatadistanceofabout0.4mfromthem.Whenleavingequipotential,theworkershallcontactthepotentialrodwiththeliveconductorsfirst,andthenwithdrawthepotentialrodquicklyafterleavingtheliveconductors0.4maway.

Duringpotentialtransfer,theactionshallbesmooth,accurateandfast.

6Enterorleaveequipotential

Enterorleaveequipotentialonasuspensiontower

Whenenteringorleavingequipotentialonasuspensiontower,theworkershallnotenterorleaveequipotentialverticallyfromthecrossarmsoralongtheinsulatorstrings.Thehangingbasket(hangingchairandhangingladder)method,theinsulatingflexibleladdermethodandothermethodsmaybeusedtoenterandleaveequipotential.

Whentheworkerentersorleavesequipotential,alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheworkerandtheearthingconductorsandtheliveconductorsshallmeettherequirementsofTables3andTable4.

Thehangingbaskets(hangingchairsandhangingladders)shallbestablysuspendedbyinsulatingslings,andthemovingspeedshallbestrictlycontrolledbyinsulatingpulleysetstoachieveauniformandslowspeed.Thelengthoftheinsulatingslingsforfixingshallbeaccuratelycalculatedoractuallymeasuredtoensurethatthehighestpartofthehumanbodyshallnotexceedtheupperedgeofthegradingringontheconductorsidewhentheworkerentersorleavesequipotential.

Enterorleaveequipotentialonatensiontower

Whenenteringorleavingequipotentialonatensiontower,theworkermayenterorleaveequipotentialalonghorizontaltensioninsulatorstringsorviaothermethods.

Whentheworkermovesalongthehorizontaltensioninsulatorstrings,thepositionsofhis/herhandsandfeetmustbekeptconsistent,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyandtoolsshallmeettherequirementsofTable5.

Theworker'ssafetyprotectionropeshallbetiedtotheinsulatorstringheldbyhis/herhandsandshallmovesynchronouslywithhim/her.

Whenenteringorleavingequipotential,theworkershalltransferpotentialwhenmovingtoadistanceofabout0.4m(2~3insulators)fromtheliveconductorsbeforecarryingoutsubsequentoperations.

Alltheelectricalgapdistances(includingtheworkingdistancesandthecombinedgaps)betweentheworkerandtheearthingconductorsandtheliveconductors,andthenumberofgoodinsulatorsshort-circuitedbythehumanbodyortoolsshallmeettherequirementsofTable5.

Mattersneedingattentionatwork

Theworkersshallavoidexcessivebodymovementsduringliveworking.

Insulatingtoolsshallbeusedtotransferarticlesbetweentheequipotentialworkerandthegroundpotentialworker.TheeffectivelengthoftheinsulatingtoolsshallmeettherequirementsofTable2.

Theconductiveclothingshallbefreefromdamageandholes,andallpartsofitshallbeconnectedwellandreliably.Whendamageandburrsarefound,itshallberepairedintime,anditcanbeusedonlyafterpassingthetest.

Beforetheinsulatingtoolsareused,aninsulationresistancetestershallbeusedtoconductsegmentedinsulationtests.Thewidthofthemeasuringelectrodesis2cm,anditisrequiredthattheinsulationresistancebetweenevery2cmofmeasuringelectrodesshallnotbelessthan700MQ.

Theinsulatingtoolsshallbeprotectedfrommoistureandsurfacedamageanddirtwhenused.Theinsulatingtoolstobeusedshallbeplacedonclean,dryandmoisture-proofpads.Whenfounddampenedorsurface-damagedorsurface-dirty,theyshallbehandledintimeandcanbeusedonlyafterpassingthetest.

Duringthework,bearingtoolsshallbefixedandreliableandhavebackupprotection.

Ifdeterioratedorlowresistanceinsulatorsarefoundduringlivetestingofinsulators,theyshallberetested2-3timestoavoidmisjudgment.

Whenthefirstinsulatornearthecrossarmisdismantledorinstalled,itmustbeshort-circuitedbeforeoperation.

Testoftools,devicesandequipment

Thedesignofliveworkingtools,devicesandequipmentshallconformtotherequirementsofGB/T18037.

Conductiveclothing,insulatingropes,insulatingrods,insulatorholders,etc.,shallpasstypetestsandleavingfactorytestsinaccordancewiththerequirementsofGB/T6568,GB/T13035,GB13398,DL/T463,DL/T878.

Thetools,devicesandequipmentshallbesubjectedtoelectricaltestsandmechanicaltestsonaregularbasisaccordingtothetestmethodsofDL/T976.Thetestcyclesareasfollows:

electricaltests.Preventivetestsshallbeconductedonceayear,andinspectiontestsshallbeconductedonceayear,andtheintervalbetweentwotestsshallbehalfayear.

mechanicaltests.Preventivetestsshallbeconductedonceeverytwoyearsforinsulatingtoolsandonceeveryyearformetaltools.

Preventivetests

DCwithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe4.8m;thewithstandvoltageshallbe755kV;thetimeshallbe3min.Itisqualifiedifnobreakdown,flashoveroroverheatingoccur.

Switchingimpulsewithstandvoltagetest:theinsulationlengthofthetestsamplebetweenthetestelectrodesshallbe4.8m;thestandardswitchingimpulsewave(+250|is/2500|is)shallbeapplied;thevoltageamplitudeshallbe1325kV;thetestsampleshallwithstand15times.Itisqualifiedifnobreakdownorflashoveroccur.

Staticloadtest:aloadof1.2timestheweightoftheratedworkingloadshallbeappliedforImin.Itisqualifiedifnodeformationordamageoccur.

Dynamicloadtest:3timesofactualoperationsshallbedonewithaloadof1.0timestheweightoftheratedworkingloadapplied.Itisqualifiedifthetoolsareflexible,portableandfreefromjamming.

Inspectiontests

Theinsulatingtoolshallbedividedintoseveralsectionsforpowerfrequencywithstandvoltagetests.Avoltageof75kVshallbeappliedacrossper300mmoftheinsulatingtoolforImin.Itisqualifiedifnobreakdown,flashoverorheatingoccur.

Thewholesetofconductiveclothingshallbefreeofdamage,holesandburrsintheappearanceinspection,andtheconnectingdevicesofallpartsshallbereliableandintact,withgoodconductionafterconnection.

Transportationandstorageoftools,devicesandequipment

Duringtransportation,theinsulatingtools,devicesandequipmentshallbeputintodedicatedtoolbags,toolboxesortoolvehiclestopreventmoistureanddamage.

Holdersandclampswithlowsurfacehardnessandmetaltools(suchasscrewrods)thatshouldnotbebumpedshallbetransportedwithdedicatedwoodenorleathertoolboxes.Thecapacityofeachboxshallbelimitedtoonesetoftools.Scatteredpartsshallbefixedinthebox.

Theinsulatingtools,devicesandequipmentshallbeprotectedfrommoisture,rainandblazingsunduringtransportationandmaintenance.Plasticbagsmaybeusedasinnerpackagingtransportationbags,andcanvasbagsordedicatedleather(canvas)boxesmaybeusedasouterpackagingtransportationbags.

Theliveworkingtools,devicesandequipmentshallbestoredinadedicateddepot,andthedepotforliveworkingtoolsshallmeettherequirementsofDL/T974.

TableofContents

TOC\o"1-5"\h\z

\o"CurrentDocument"

Foreword II

\o"CurrentDocument"

Scope 1

\o"CurrentDocument"

Normativereferences 1

\o"CurrentDocument"

Termsanddefinitions 2

\o"CurrentDocument"

Generalrequirements 2

\o"CurrentDocument"

Technicalrequirements 4

\o"CurrentDocument"

Enterorleaveequipotential 8

\o"CurrentDocument"

Mattersneedingattentionatwork 9

\o"CurrentDocument"

Testoftools,devicesandequipment 9

\o"CurrentDocument"

Transportationandstorageoftools,devicesandequipment 11

TableofContents

Foreword II

Scope 1

Normativereferences 1

Termsanddefinitions 2

\o"CurrentDocument"

Generalrequirements 2

Technicalrequirements 4

Enterorleaveequipotential 8

Mattersneedingattentionatwork 9

Testoftools,devicesandequipment 9

Transportationandstorageoftools,devicesandequipment 11

TableofContents

TOC\o"1-5"\h\z

Foreword II

Scope 1

Normativereferences 1

Termsanddefinitions 2

Generalrequirements 2

Technicalrequirements 4

Enterorleaveequipotential 8

Mattersneedingattentionatwork 9

Testoftools,devicesandequipment 9

Transportationandstorageoftools,devicesandequipment 11

Foreword

ThisstandardwascompiledinaccordancewiththetaskarrangedbyNoticeoftheNationalEnergyAdministrationonIssuingtheFirstBatchofIndustryStandardFormulati()n(Revisi(m)PlansintheEnergySectorin2010(No.320oftheDepartmentofScienceandTechnologyoftheNationalEnergyAdministration).

ThisstandardwasproposedbytheChinaElectricityCouncil.

ThisstandardwaspreparedbytheNationalTechnicalCommitteeofStandardizationforLiveWorking.

Maindraftingorganizationsofthisstandard:ChinaElectricPowerResearchInstitute,StateGridShandongElectricPowerCompany,andStateGridShanxiElectricPowerCompany.

Maindraftersofthisstandard:LIUKai,HUYi,XIAOBin,LIUHongzheng,LIUTing,MENGHailei,YONGJun,NIUBiao,DONGYanwu,LIUYan,PENGYong,andSUZiming.

Duringtheprocessofimplementingthisstandard,relevantopinionsoradvicecanbefedbacktotheStandardizationManagementCenteroftheChinaElectricityCouncil(No.l,Lane2,BaiguangRoad,Beijing,100761).

TechnicalGuideforLiveWorkingon±660kVDCTransmissionLine

Scope

Thisstandardspecifiesthetechnicalrequirementsandmattersneedingattentionforliveworkingon±660kVDCtransmissionlines,aswellasthetest,transportationandstorageoftheworkingtools.

Thisstandardisapplicabletoliveworkingon±660kVDCtransmissionlinesinareaswithanaltitudeof2000mandbelow.

Normativereferences

Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.

GB/T2900.55ElectrotechnicalTerminology一LiveWorking(eqvIEC60050—651)

GB/T6568ScreenClothesforLiveWorking(GB/T6568—2008,IEC60895:2002,MOD)

GB/T13035LiveWorking一InsulatingRopes

GB13398InsulatingHollowTubesandFoam-FilledTubesandSolidRodsforLiveWorking

GB/T14286LiveWorking—TerminologyforTools,EquipmentandDevices(GB/T14286—2008,IEC60743:2001,MOD)

GB/T18037TechnicalRequirementsandDesignGuideforLiveWorkingTools

GB26859SafetyCodeofElectricPowerIndustry-PartofElectricLines

DL/T463InsulatorHolderforLiveWorking

DL/T876GuideofInsulationCoordinationforLiveWorking

DL/T878TestGuideoftheInsulatingToolforLiveWorking

DL/T966TechnicalGuideforLiveWorkinginTransmissionLine

DL/T974DepotofToolsforLive-Working

DL/T976PreventiveTestCodeofTools,DevicesandEquipmentforLiveWorking

Termsanddefinitions

Forthepurposesofthisstandard,thetermsanddefinitionsgiveninGB/T2900.55andGB/T14286aswellasthefollowingapply.

liveworkingonDCtransmissionline

live-linerepair,maintenance,andreplacementofpartscarriedoutonDCtransmissionlines

potentialrod

metaltoolusedbyanequipotentialworkerwhenenteringorleavingequipotential,inordertoreducetheimpactofdischargearconthehumanbodyandavoidpossibledamagetoconductiveclothingcausedbypulsedcurrent

electricfieldshieldmask

maskmadeofconductivematerials,usedforelectricfieldprotectionoftheworker'sface,andconnectedwithotherscreentoolsforintegraluse

Generalrequirements

Personnelrequirements

Liveworkingworkersshallbeingoodhealthandfreefromphysicalandpsychologicalobstaclesthathinderwork.Theyshallhaveabasicknowledgeofelectricalprinciplesandpowerlines,masterthebasicprinciplesandoperatingmethodsofliveworking,andbefamiliarwiththescopeofapplicationandusingmethodsoftheworkingtools.TheyshallbefamiliarwithGB26859,DL/T966andthisstandard.Theyshallmasteremergencyrescuemethods,especiallytheelectricshockrescue.Theyshallreceivetheoreticalandoperationaltrainingfromspecializedtraininginstitutions,passrelevantexaminationsandholdrelevantcertificates.

Thepersoninchargeofthework(orthesafetyguardian)shallhaveatleast3yearsofactualworkingexperienceinliveworkingonpowertransmissionlines,befamiliarwithequipmentconditions,havecertainorganizationalcapabilityandaccidenthandlingability,andpasstheexaminationafterspecialtraining.

Institutionalrequirements

AccordingtoGB26859andthisstandard.

Meteorologicalrequirements

Liveworkingshallbecarriedoutingoodweather.Incaseofthunder,rain,snowandfog,liveworkingshallnotbecarriedout.Whenthewindforceisgreaterthanlevel5(lOm/s),liveworkingshouldnotbecarriedout.

Ifliveworkingisrequiredinweatherwithrelativehumiditygreaterthan80%,insulatingtoolswithmoisture-proofperformanceshallbeadopted,andthepossibilityofinsulationdegradationoftheinsulatingtoolsunderhighhumidityshallbeconsidered.

Underspecialoremergentconditions,whenemergentlive-linerepairmustbecarriedoutinharshclimate,relevantengineeringandtechnicalpersonnelandallworkingpersonnelshallbeorganizedtofullydiscussandformulatereliablesafetymeasuresaccordingtothesiteclimateandworkingconditions,andtheemergentlive-linerepaircanbecarriedoutonlyaftertheapprovalofthechiefengineeroftheunitortheleaderinchargeofproductionoftheunit.Sufficientlightingfacilitiesshallbeprovidedfornightwork.

Incaseofasuddenchangeofweatherduringliveworking,whichcanendangerpersonalorequipmentsafety,theworkshallbestoppedimmediately.Undertheconditionofensuringpersonalsafety,thenormalworkingconditionsoftheequipmentshallberestoredassoonaspossibleorotherprotectivemeasuresshallbetaken.

Otherrequirements

Fornewliveworkingprojectsthataremorecomplicatedandmoredifficultandnewdevelopedtools,scientifictestsshallbeconductedtoconfirmsafetyandreliability,andsafetymeasuresandoperationprocessplansshallbeestablished,andthetoolscanbeoperatedonequipmentonlyaftertheapprovalofthechiefengineeroftheunitortheleaderinchargeofproductionoftheunit.

Thepersoninchargeofliveworkingshallcontactthedispatcherbeforetheworkstarts,andtheworkcanbestartedonlyaftercontacting.WhenitisnecessarytodisableDCrestartprotectiondevices,thelicenseformalitiesshallbeperformed.Aftertheworkisfinished,reportingtothedispatchershallbedoneintime.Itisstrictlyprohibitedtostoporresumetherestartprotectiondevicesatanappointedtime.

Technicalrequirements

Groundpotentialworking

Whentheworkerworksatgroundpotential,theminimumworkingdistancebetweentheworkeratgroundpotentialonthetowerandtheliveconductorsshallmeettheprovisionsofTable1.

Table1Minimumworkingdistanceofgroundpotentialworking

Altitude/m

Minimumworkingdistance/m

<500

4.2

500~1000

4.5

1000~1500

4.7

1500~2000

5.0

Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbelessthan0.5mandshallbeconsideredatwork.

Theminimumeffectiveinsulationlengthofinsulatingtools,devicesandequipmentshallmeettheprovisionsofTable2.

Table2Minimumeffectiveinsulationlengthofinsulatingtools,devicesandequipment

Altitude/m

Minimumworkingdistance/m

<500

5.0

500—1000

5.3

1000~1500

5.6

1500~2000

5.9

Barehandworking

Duringbarehandworking,theminimumworkingdistancebetweentheequipotentialworkerandtheearthingconductorsshallmeettheprovisionsofTable3.

Table3Minimumworkingdistanceofbarehandworking

Altitude/m

Minimumworkingdistance/m

Distancebetweentheequipotentialworkerandthesidetowerframe

Distancebetweentheequipotentialworkerandthetopcrossarmorthetopframe

<500

4.2

4.8

500~1000

4.5

5.1

1000~1500

4.7

5.3

1500~2000

5.0

5.6

Note:Thevaluesinthetabledonotincludethespaceoccupiedbythehumanbody,whichshallnotbeless

than0.5mandshallbeconsideredatwork.

Whentheworkerentersorleavesequipotentialviainsulatingtoolsoralonginsulatorstrings,theminimumcombinedgapshallmeettheprovisionsofTable4.

Table4Minimumcombinedgap

Altitude/m

Minimumcombinedgap/m

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论