版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
MaterialsSystemSpecification
34-SAMSS-634 21December2005
LocalZVControlSystems
InstrumentationStandardsCommitteeMembers
Awami,LuayHussain,ChairmanTuin,Rienk,ViceChairmanBogusz,ZbigniewJozef
Dakhil,TareqKhalilDhafeeri,FarhanTaiehEll,StevenTal
Fadley,GaryLowellFalkenberg,AntonRaymondQaffas,SalehAbdalWahabGawargy,NabilErianGrainger,JohnFrancisJumah,YousifAhmedKhalifa,AliHussain
Madhi,FawazAbdullahMahmood,Balal
Qarni,MahdiAli
SaudiAramcoDeskTopStandards
TableofContents
1 Scope. 2
2 sandDeviations. 2
References. 2
EnvironmentalConditions 3
GeneralRequirements. 5
SmartZVLocalControlSystem. 5
LocalZVShutdownCabinets. 10
Installation. 10
ElectricalInstallation. 11
Nametes. 11
Drawings. 11
OtherMiscellaneousRequirements. 12
PreviousIssue:31March2004 Next nnedUpdate:1January2011
Revisedparagraphsareindicatedintherightmargin Page1of12Primarycontact:Flanders,PatrickScotton966-3-
Copyright©SaudiAramco2005.s .
Responsibility:InstrumentationIssueDate:21December2005
34-SAMSS-634
Next
nnedUpdate:1January2011
LocalZVControlSystems
Page
PAGE
8
of
NUMPAGES
12
1 Scope
ThisspecificationcoverstheSaudiAramcorequirementsforlocalEmergencyIsolationValve(ZV)controlsystems.IncludedarerequirementsfortheESDsysteminput/outputchannels,thelocalcontrolpanel(LCP),andthesmartvalvecontrollerthatmakeupeachSmartZV.TheSmartZVassemblyprovideslocalcontrolandtestingfunctionalityforspringreturnanddoubleactingp aticvalveactuators.Functionalrequirementsareclarifiedincludingthe"partialstroke"featureprovidedforon-linetestingofZV's.
Alternativedesignsshallonlybeusedwhenpre-approvedbytheManager,ProcessandControlSystemsDepartment.
CommentaryNotes:
AllEmergencyIsolationValves(ZV's)arerequiredtobedesignedandinstalledsuchthattheycanbefunctionallytestedwhileon-line(in-service).Functionaltestingmaytaketheformofafull-stroketestora"partialstroke"test.
"Partialstroke"testingprovidesawaytoverifyZVperformancewhenfunctionaltestingisrequiredwhiletheZVison-line."PartialStroke"testingisnotintendedtotaketheceoffull-strokeZVfunctionaltests.Rather,"partialstroke"testingshouldbeperformedtomeettherequiredfunctionaltestinterval(e.g.,quarterly)betweenscheduledunitshutdownswhenfullstroketestingcanbeperformed.
2 sandDeviations
AnysbetweenthisspecificationandotherapplicableSaudiAramcoMaterialsSystemSpecifications(SAMSSs),EngineeringStandards(SAESs),EngineeringProcedures(SAEPs),StandardDrawings(SASDs)orindustrystandards,codes,andformsshallberesolvedinwritingbytheorBuyerRepresentativethroughtheManager,Process&ControlSystemsDepartmentofSaudiAramco,Dhahran.
DirectallrequeststodeviatefromthisspecificationinwritingtotheorBuyerRepresentative,whoshallfollowinternal procedureSAEP-302andforwardsuchrequeststotheManager,Process&ControlSystemsDepartmentofSaudiAramco,Dhahran.
References
ThefollowingSupplementarySpecificationsarereferencedbyandformapartofthisspecification.
SaudiAramcoReferences
SaudiAramcoEngineeringProcedure
SAEP-302 InstructionsforObtainingaWaiverofa
MandatorySaudiAramcoEngineeringRequirement
SaudiAramcoLibraryDrawings
DB-950129 LocalShut-DownCabinet(Conventional)
DA-950065 LocalShut-DownCabinet(LimitedTravelTest)DB-950106 SmartZV
SaudiAramcoInspectionRequirements
Form175-343100 InstrumentControlCabinets–Outdoor
SaudiAramcoFormsandDataSheets
FormNMR-7907 NonMaterialRequirementsforInstrumentation
(General)Form8020-634-ENG LocalZVControls
IndustryCodesandStandards
Thecabinetshallbedesignedandfabricatedinconformancewiththelatestrequirementsofthefollowing:
TheInternationalSocietyforMeasurementandControl–ISA
ISARP60.6 Nametes,LabelsandTagsforControlCenters
NationalElectricalManufacturersAssociation
NEMA250 EnclosuresforElectricalEquipment(1000Voltsum)
NEMAICS6 EnclosuresforIndustrialControlsandSystems
NationalFireProtectionAssociation
NFPA70 NationalElectricalCode
Whenlistingisavailable,allequipmentandmaterialsofconstructionshallbelistedfortheintendedservicebyUnderwritersLaboratories,Inc.(UL),FactoryMutualResearchCorporation(FM),orotherrecognizedtestinglaboratory.
EnvironmentalConditions
Temperature
ZVcabinetinstrumentsandcontrolcomponentsshalloperatecontinuously
underthefollowingambientairtemperatureswithoutanydegradationofthemanufacturer'sguaranteedperformance.
OutdoorSheltered(1)(2)(3)
OutdoorUnsheltered(2)(3)
um
55°C(131°F)
65°C(149°F)
Minimum
0°C(32°F)
0°C(32°F)
Notes:
"Sheltered"referstopermanent,ventilatedenclosuresorbuildings,orpermanentlyfixedsunshadeswithatopandthreesides.
Forinstrumentswhichdissipateinternalheatandareinstalledincustomengineeredenclosures(e.g.,enclosuresnotincludedintheoriginalmanufacturer'stemperaturecertification),anadditional15°Cshallbeaddedtotheaboveumtemperatures.Anexample,for"indoorairconditioned"installation,theequipmentmustperformat35+15=50°C.Similarly,forthe"outdoorunsheltered"case,theequipmentshallbedesignedforaumoperatingtemperatureof65+15=80°C.
Fortheoutdoorinstallationsonly,thedesignercantakecreditfordorpassivecoolingtoeliminateorreducethe15°Cheatrise.Forexample,ifvortexcoolersareused,theheatremovalcapacityofthecoolersmaybesubtractedfromthegeneratedheat.Nomorethan15°Creductionintemperaturewillbegivenascredit.Thedesignershallsubstantiatehibyprovidingthesupportdataandcalculations.
Humidity
Designbasisshallbe5%to95%relativehumidity(non-condensing).
Contaminants
Theinstrumentmanufacturershallensurethatallequipmentisdesignedtowithstandthefollowingairqualityrequirements.
CommentaryNote:
Air-bornedustconcentrationsandcontaminantlevelsareusedinmechanicalequipmentdesign,whensizingairfiltersandasameasureofpotentialdustingress.
DustConcentration
Usualairbornedustconcentrationis1mg/m³.Duringsandstorms,dustconcentrationsmayreach500mg/m³.Particlesizesareasfollows:
95%ofallparticlesarelessthan20micrometers50%ofallparticlesarelessthan1.5micrometers
Elementspresentindustincludecompoundsofcalcium,silicon,magnesium,aluminum,potassium,chloridesandsodium.Whenwetted(highhumidityconditions)thesecompoundsfunctionaselectrolytesandcanresultinseverecorrosion.
Otherpollutantspresentintheatmosphereunderthemostextremeconditionsare:
H2S 20ppm(Vol/Vol)
Hydrocarbon 150ppm(Vol/Vol)
SO2 10ppm(Vol/Vol)
CO 100ppm(Vol/Vol)
NOx 5ppm(Vol/Vol)
O3 1ppm(Vol/Vol)
Wind-borneSeaWaterSpray
Equipmentinstalledoffshoreornearshore(i.e.,within0.5kmfromshoreline),shallbesuitedfortheharshenvironment(NEMA4Xenclosure,316SSTexternals,hermiticallysealed,etc.).
GeneralRequirements
LocalZVControl
Eachp aticallyoperatedZVshallbeprovidedwithlocalcontrolsthatpermittheZVtobeoperatedintheeventofanemergencyandtobereturnedtothenormaloperatingpositionlocallywhentheemergencyconditionshavereturnedtonormal,tripinitiatorsarehealthy,andthelogicsystemhasbeenreset(ready-to-resetlightenergized).
LocalZVReset
ResettingtheESDsystemlogicviatheremotepushbuttoninthecontrolroomshallnotcausetheassociatedZV'stoautomaticallyreturntotheirnormaloperatingposition.Manual'local'operatorinterventionisrequiredtoverifyconditionsinthefieldpriortoresettingaZV,followingatrip.
Inhigh-pressureapplications(GOSPinlet,etc.),theESDsystemshallpreventtheZVfromopeninguntilthepressuredifferentialacrossthevalvehasreachedasafelevel(viadifferentialpressureESDinput).
SmartZVLocalControlSystem
TheSmartZVsystemshallbecomprisedofaLocalControlPanel(LCP),asmartvalvepositioner,solenoidvalves,anESDHARThandheldcommunicator(orequalcomputerbasedconfiguration),andassociatedESDI/Oasoutlinedinsection6.6andshowninLibraryDrawingDB-950106,Sheets1and2.Inaddition,whenrequestedbythe
proponent,HARTsignalsplitters/multiplexerswithintheESDsystemmarshallingcabinetsshallbeprovidedtofacilitateintegrationwithandvendorspecificvalvediagnosticsoftware.
LocalControlPanel(SmartZV)
EachSmartZVshallbeequippedwithalocalcontrolpanel(LCP)topermittheZVtobeoperatedlocallyintheeventofanemergency,tobereturnedtothenormaloperatingpositionwhenthetripinitiatorsarehealthy,andtofacilitatefunctionaltestingoftheZV.
SmartZVLCPPushbuttons
ASmartZVLCPshallincludethreepushbuttons:1)valveclose,
2)valveopen,and3)test.
Thelocalpushbuttonsshallbeshroudedtopreventunintendedactuation.
CommentaryNote:
TheSmartZVLCPpushbuttonsarecloselyintegratedwithESDsystemlogicandthecontrolelementsmountedonthevalve(smartvalvepositioner,solenoidvalves,andlimitswitches).
ValveClosePush-button
Amomentarycontactpushbuttontoclosethevalveshallbeprovided.ThelocalvalveclosepushbuttoncontactsshallopenonactuationandshallbehardwiredasadiscreteinputtotheESDsystem.TheESDlogicandoutputsshalldrivethevalvetotheclosedpositionwhenthelocalclosepushbuttonisactivatedattheLCP.
ValveOpenPush-button
Amomentarycontactpushbuttontoopenthevalveshallbeprovided.ThelocalvalveopenpushbuttoncontactsshallcloseonactuationandshallbehardwiredasadiscreteinputtotheESDsystem.TheESDlogicandoutputsshalldrivethevalvetotheopenpositionwhenthelocalopenpushbuttonisactivatedattheLCP.
TestPush-button
Amomentarycontactpushbuttontoinitiateapartial-stroketestshallbeprovided.Thelocaltestpushbuttonshallcloseon
actuationandshallbehardwiredfromtheLCPdirectlytothesmartvalvepositioner(shallinitiatetheuserdefinedpartialstroketestresidinginmemorywithinthesmartvalvepositioner).
SmartZVLCPIndicationLamps:
TheLCPshallincludea"ready-to-reset"indicationlamptoprovidelocalindicationwhentheZVmaybereturnedtothenormaloperatingpositionfollowinganESDsystemtrip.The"ready-to-reset"lampshallbepoweredviaadiscreteoutputfromtheESDsystem.
CommentaryNote:
Ready-to-Resetlight:ThelampshallilluminatewhenallrelevantESDinputsareinthehealthyconditionandthelogicsystemhasbeenreset.Thelampshallextinguishwhenthevalvemovesfromthefail-safeposition.
WhenspecifiedonForm8020-634-ENG,localZVopenandclosedvalvepositionindicationlampsshallbeincludedwithintheLCP.
LEDtypelightsshallbeprovided(e.g.,Stahl8010/2-01orequal).
ColorsusedshallbeOpen–Green,Closed–Red,andReadytoReset–Amber.
LightsshallberemovableandreceablewhiletheZVison-line(inservice).
LocalControlPanelTerminations
TerminalstripswithintheZVLCPshallbeadequaysizedtoalloweasyaccesstotheterminations(hinged"swing-out"spacesaver,doubleortriplegangtypeterminationsarenotallowed).
TheLCPenclosureshallbeadequaysizedtoalloweasyterminationofexternalcablesandincludespaceforthelayofconductors.
LocalControlPanelVent/Drain
Acombinationvent/drainfittingshallbeprovidedoneachLCP.
SmartValvePositioner
AZVwillbemade"smart"bytheintroductionofasmarectro-p aticvalvepositioneraspartofthevalveassembly(FisherRosemountDVC6000orapprovedequalwithexternalsolenoidvalve).
ThesmartvalvepositionershallbemountedontheZVactuatortofacilitateon-line,partialstroke(limitedtravel)testing,full-strokeout-of-servicetesting,andself-healthmonitoringviathesmartvalvepositionerdiagnosticsoftware.
Thepositionershallbeinstalledinserieswithsolenoidvalve(s).
ThesmartvalvepositionershallcommunicatewiththeESDsystemviaadedicated4-20maDC/HARThybridESDoutputchannel.Intheeventofatrip,thesolenoidvalvewillchangestate(de-energize)andthepositionersignal
(4-20mADC)shallbedriventotheuserdefinedvalue.
SmartValvePositionerMountingKit
EachSmartZVpositionershallbedwithanactuatormountingkitdesignedspecificallyforuseontheintendedactuator.Ea ountingkitshallincludeprovisionsforvalvepositionlimitswitches(valveopenandvalveclosed).Hermeticallysealedortotallyencapsulated,mechanicalswitchorproximitysensorpositionswitcheswithcontactsratedfortherequiredloadshallbespecified.
On-lineTesting
EachSmartZVshallbeequippedwithaLCPasdescribedaboveinSection6.1.Inadditiontotheopenandclosepushbuttons,a"valvetest"pushbuttonshallbeincludedtoinitiatethepredefinedpartialstroketest(residinginmemorywithinthesmartvalvepositioner).
InadditiontotheLCP"test"pushbutton,on-linetestingofaSmartZVmaybeinitiatedviaHARTprotocolusingalaptopcomputerwithvendorspecifiedvalvetestinganddiagnosticsoftware.Remotepartial-stroketestingofZVsmayalsobe plishedbyusing'HART'multiplexedexternaloutputterminationmodulesorassemblieswithanassociatedZVmaintenanceworkstation.
CommentaryNote:
TheselectionandloadingoftheMultiplexersandHARTfiltersdwithESDmarshallingterminationstointegratethehybridHART og4-20mAsignaltothesmartvalvepostioner,shallbeguaranteedbytheESDvendorforproperoperationwiththeESD ogI/Ocardandthesmartvalvepositioner.
SolenoidValve(s)
ThesolenoidvalvesutilizedwithSmartZV'sshallbeelectro-p aticdirectoperatingorexternalpilottype(capableofoperatingwithoutapplieddifferentialpressure).Theyshallbeusedtopressurize/venttheactuatorinresponsetoanESDtripinafail-safearrangementwiththesmartvalvepositioner.AllsolenoidvalvesshallbespecifiedwithVitoninternals.
ReferenceLibraryDrawingDB-950106,Sheet1and2fortheEmerson/FisherDVCbasedSmartZVarchitecture.
ESDI/O
TheSmartZVisanintegrationoflocalcontrolsmountedontheZV(smartvalvepositioner,solenoidvalves,limitswitches,etc.),theLCP,andESDsystemI/Oandlogic.TheESDI/OrequiredtointegrateaSmartZVissummarizedinthetablebelow.
SmartZVESDI/ORequirements
ESDInputs/Outputs
Type
Description
DiscreteInput-1
LimitSwitch-ZVvalveopen
UsedwithinESDlogictomonitorZVposition.
DiscreteInput-2
LimitSwitch-ZVvalveclosed
UsedwithinESDlogictomonitorZVposition.
DiscreteInput-3
Pushbutton–ZVvalveopen
ThispushbuttonislocatedontheLCP.
DiscreteInput-4
Pushbutton–ZVvalveclose
ThispushbuttonislocatedontheLCP.
DiscreteOutput-1
SolenoidValve(s)
Provideshighvalveflowcoefficient(Cv)tomeetZVclosuretimerequirementandprovidestheprimaryESDfunction.
Note:ThesmartvalvepositionerwillalsomovethevalvetothefailsafepositionshouldthesolenoidfailtooperateduringanESDtrip.
OndoubleactingZV'swheretwosolenoidsareused,andtheyarebothcontrolledbythisone(1)ESDoutput.
DiscreteOutput-2
IndicationLamp-ReadytoReset(Ambercolor)
ThisIndicationLampislocatedinthelocalcontrolpanel(LCP).
ProvideslocalindicationattheZVwhentheESDhasbeenresetinthecontrolroomandallpermissivesaremet.OnlythenmaytheZVbesafelyreturnedtothe"normaloperatingposition."
DiscreteOutput–3OPTIONAL
IndicationLamp–ValveOpen(Greencolor)
ThisindicationLampislocatedinthelocalcontrolpanel(LCP).
ProvideslocalindicationattheZVwhenthevalveisfullyopen(viahardwiredlimitswitchtoESDdiscreteinput).
Responsibility:InstrumentationIssueDate:21December2005
34-SAMSS-634
Next
nnedUpdate:1January2011
LocalZVControlSystems
Page
PAGE
10
of
NUMPAGES
12
ESDInputs/Outputs
Type
Description
DiscreteOutput–3OPTIONAL
IndicationLamp–ValveClosed(Redcolor)
ThisindicationLampislocatedinthelocalcontrolpanel(LCP).
ProvideslocalindicationattheZVwhenthevalveisfullyclosed(viahardwiredlimitswitchtoESDdiscreteinput).
ogOutput–1
ZVpositioner
ogoutput(4-20mA)toSmartValvePositioner.
ThissignalprovidesabackupmeanstodrivetheZVtothefail-safepositionshouldtheprimaryESDdevice(solenoidvalve)failtofunction.
MultiplexedESDI/OisrequiredtoutilizeHARTdiagnosticinformationavailabletoaValvLinkworkstation.
Field'Test'Pushbutton
Type
Description
LocalControlPanelZV"Test"Pushbutton
Pushbutton–InitiatePartialStrokeTest
LCPZVTestpushbuttonishardwireddirectlytothesmartvalvepositioner.
LocalTestpushbuttoninitiatesthepredefined"partialstroke"test.Thesmartvalvepositionersavesthemostrecentvalvetestsignature.
LocalZVShutdownCabinets
WhenSmartZVlocalcontrolsarenotsuitedtotheapplication(e.g.,gasoperatedvalves),localZVshutdowncabinetsshallmeetthedesignrequirementsofthisspecification,SaudiAramcoForm8020-634-ENG,andtheapplicableSaudiAramcoLibraryDrawing(DB-950129orDA-950065).
Alternativedesignsshallonlybeusedwhenpre-approvedbytheManager,ProcessandControlSystemsDepartment.
Installation
Tubingshallbeseamless,316stainlesssteel.Theminimumtubesizeshallbe½inch(12.7mm)O.D.andhaveaminimumwallthicknessof0.03inch(0.75mm).
Exception:
Non-flowingp atictubingsuchaspilotoperatedsolenoidvalveimpulselinesmaybe¼inch(6.35mm)O.D.
Fittingsshallbe316stainlesssteelcompressiontypeSwagelok,Parker,orequal.Threadedconnectionsshallbesealedusingpaste.
Tubingshallbebentusingatubingbender,reamedandinternallycleanedpriortoinstallation.
Pressuregaugesindicating ingsupplypressureandoperatingpressuretothevalveactuator(openandclosedsideofdualactingandopensideofsingleactingactuators)shallbeprovidedinSIorEnglishunitsconsistentwiththeunitconventionusedintheintendedntlocation.
ElectricalInstallation
AllmaterialsandequipmentshallmeetNFPA70,NationalElectricalCoderequirementsfortheintendedhazardousareas.
Allcomponents(solenoidvalves,limitswitches,indicationlights,etc.,shallbecertifiedforuseintheintendedhazardousareabyanapprovedtestingagencywithouttheneedforanyadditionalexternalprotection.BothEExandAExCertifieddevicesareacceptable.
ElectricalwiringandinstallationshallconformtotherequirementsoftheNFPA70,NationalElectricalCode,latestedition.WiringinternaltotheLCPandlocalZVshutdowncabinetshallbe18AWGminimum.
Wireendsshallconnecttopolyamideterminalswithinthecabinet.TerminalmakeshallbeKlippon,Weidmuller,orequal.
Nametes
NametesshallfollowISARP60.6guidelines.
AllinstrumentsmountedinsidelocalZVshutdowncabinetsorassociatedwithSmartZVsystems,shallbeidentifiedbyanameteincludingthetagnumberandservicedescription.
Thenametesshallbeattachedwithstainlesssteelscrewsorstainlesssteelwire.
Nametesshallbem
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024打磨岗位全职员工协议样本
- 2024年房产建筑项目总承包协议示例
- 2024年重型挂车所有权转移协议
- 2024年高端别墅买卖协议范本
- 2024年顾问协作劳动协议正式样本
- 2024年篮球场馆施工项目协议细则
- 数字化转型背景下的研究生教育治理重构研究
- 教师教育转型发展实施方案:为教育强国奠定基础
- 高低压开关柜市场需求变化及行业趋势分析
- 低空经济产业分析:趋势、市场与需求
- 2024年公路标识安装合同
- 印刷排版岗位招聘笔试题与参考答案(某大型央企)2025年
- 【餐饮店铺管理系统设计与实现(论文)15000字】
- 2.1充分发挥市场在资源配置中的决定性作用(课件) 2024-2025学年高中政治 必修2 经济与社会
- 2024年秋季新人教PEP版3年级上册英语全册课件(新版教材)
- 2024年菱角项目可行性研究报告
- 农产品质量追溯系统操作手册
- 道法珍惜师生情谊教学课件 2024-2025学年统编版道德与法治七年级上册
- 2024年高考真题-化学(贵州卷) 含答案
- 2024-2030年中国线束行业市场发展趋势与前景展望战略分析报告
- 居间战略合作协议书范本
评论
0/150
提交评论