MaterialsSystemSpecification

34-SAMSS-634 21December2005

LocalZVControlSystems

InstrumentationStandardsCommitteeMembers

Awami,LuayHussain,ChairmanTuin,Rienk,ViceChairmanBogusz,ZbigniewJozef

Dakhil,TareqKhalilDhafeeri,FarhanTaiehEll,StevenTal

Fadley,GaryLowellFalkenberg,AntonRaymondQaffas,SalehAbdalWahabGawargy,NabilErianGrainger,JohnFrancisJumah,YousifAhmedKhalifa,AliHussain

Madhi,FawazAbdullahMahmood,Balal

Qarni,MahdiAli

SaudiAramcoDeskTopStandards

TableofContents

1 Scope. 2

2 sandDeviations. 2

References. 2

EnvironmentalConditions 3

GeneralRequirements. 5

SmartZVLocalControlSystem. 5

LocalZVShutdownCabinets. 10

Installation. 10

ElectricalInstallation. 11

Nametes. 11

Drawings. 11

OtherMiscellaneousRequirements. 12

PreviousIssue:31March2004 Next nnedUpdate:1January2011

Revisedparagraphsareindicatedintherightmargin Page1of12Primarycontact:Flanders,PatrickScotton966-3-

Copyright©SaudiAramco2005.s .

Responsibility:InstrumentationIssueDate:21December2005

34-SAMSS-634

Next

nnedUpdate:1January2011

LocalZVControlSystems

Page

PAGE

8

of

NUMPAGES

12

1 Scope

ThisspecificationcoverstheSaudiAramcorequirementsforlocalEmergencyIsolationValve(ZV)controlsystems.IncludedarerequirementsfortheESDsysteminput/outputchannels,thelocalcontrolpanel(LCP),andthesmartvalvecontrollerthatmakeupeachSmartZV.TheSmartZVassemblyprovideslocalcontrolandtestingfunctionalityforspringreturnanddoubleactingp aticvalveactuators.Functionalrequirementsareclarifiedincludingthe"partialstroke"featureprovidedforon-linetestingofZV's.

Alternativedesignsshallonlybeusedwhenpre-approvedbytheManager,ProcessandControlSystemsDepartment.

CommentaryNotes:

AllEmergencyIsolationValves(ZV's)arerequiredtobedesignedandinstalledsuchthattheycanbefunctionallytestedwhileon-line(in-service).Functionaltestingmaytaketheformofafull-stroketestora"partialstroke"test.

"Partialstroke"testingprovidesawaytoverifyZVperformancewhenfunctionaltestingisrequiredwhiletheZVison-line."PartialStroke"testingisnotintendedtotaketheceoffull-strokeZVfunctionaltests.Rather,"partialstroke"testingshouldbeperformedtomeettherequiredfunctionaltestinterval(e.g.,quarterly)betweenscheduledunitshutdownswhenfullstroketestingcanbeperformed.

2 sandDeviations

AnysbetweenthisspecificationandotherapplicableSaudiAramcoMaterialsSystemSpecifications(SAMSSs),EngineeringStandards(SAESs),EngineeringProcedures(SAEPs),StandardDrawings(SASDs)orindustrystandards,codes,andformsshallberesolvedinwritingbytheorBuyerRepresentativethroughtheManager,Process&ControlSystemsDepartmentofSaudiAramco,Dhahran.

DirectallrequeststodeviatefromthisspecificationinwritingtotheorBuyerRepresentative,whoshallfollowinternal procedureSAEP-302andforwardsuchrequeststotheManager,Process&ControlSystemsDepartmentofSaudiAramco,Dhahran.

References

ThefollowingSupplementarySpecificationsarereferencedbyandformapartofthisspecification.

SaudiAramcoReferences

SaudiAramcoEngineeringProcedure

SAEP-302 InstructionsforObtainingaWaiverofa

MandatorySaudiAramcoEngineeringRequirement

SaudiAramcoLibraryDrawings

DB-950129 LocalShut-DownCabinet(Conventional)

DA-950065 LocalShut-DownCabinet(LimitedTravelTest)DB-950106 SmartZV

SaudiAramcoInspectionRequirements

Form175-343100 InstrumentControlCabinets–Outdoor

SaudiAramcoFormsandDataSheets

FormNMR-7907 NonMaterialRequirementsforInstrumentation

(General)Form8020-634-ENG LocalZVControls

IndustryCodesandStandards

Thecabinetshallbedesignedandfabricatedinconformancewiththelatestrequirementsofthefollowing:

TheInternationalSocietyforMeasurementandControl–ISA

ISARP60.6 Nametes,LabelsandTagsforControlCenters

NationalElectricalManufacturersAssociation

NEMA250 EnclosuresforElectricalEquipment(1000Voltsum)

NEMAICS6 EnclosuresforIndustrialControlsandSystems

NationalFireProtectionAssociation

NFPA70 NationalElectricalCode

Whenlistingisavailable,allequipmentandmaterialsofconstructionshallbelistedfortheintendedservicebyUnderwritersLaboratories,Inc.(UL),FactoryMutualResearchCorporation(FM),orotherrecognizedtestinglaboratory.

EnvironmentalConditions

Temperature

ZVcabinetinstrumentsandcontrolcomponentsshalloperatecontinuously

underthefollowingambientairtemperatureswithoutanydegradationofthemanufacturer'sguaranteedperformance.

OutdoorSheltered(1)(2)(3)

OutdoorUnsheltered(2)(3)

um

55°C(131°F)

65°C(149°F)

Minimum

0°C(32°F)

0°C(32°F)

Notes:

"Sheltered"referstopermanent,ventilatedenclosuresorbuildings,orpermanentlyfixedsunshadeswithatopandthreesides.

Forinstrumentswhichdissipateinternalheatandareinstalledincustomengineeredenclosures(e.g.,enclosuresnotincludedintheoriginalmanufacturer'stemperaturecertification),anadditional15°Cshallbeaddedtotheaboveumtemperatures.Anexample,for"indoorairconditioned"installation,theequipmentmustperformat35+15=50°C.Similarly,forthe"outdoorunsheltered"case,theequipmentshallbedesignedforaumoperatingtemperatureof65+15=80°C.

Fortheoutdoorinstallationsonly,thedesignercantakecreditfordorpassivecoolingtoeliminateorreducethe15°Cheatrise.Forexample,ifvortexcoolersareused,theheatremovalcapacityofthecoolersmaybesubtractedfromthegeneratedheat.Nomorethan15°Creductionintemperaturewillbegivenascredit.Thedesignershallsubstantiatehibyprovidingthesupportdataandcalculations.

Humidity

Designbasisshallbe5%to95%relativehumidity(non-condensing).

Contaminants

Theinstrumentmanufacturershallensurethatallequipmentisdesignedtowithstandthefollowingairqualityrequirements.

CommentaryNote:

Air-bornedustconcentrationsandcontaminantlevelsareusedinmechanicalequipmentdesign,whensizingairfiltersandasameasureofpotentialdustingress.

DustConcentration

Usualairbornedustconcentrationis1mg/m³.Duringsandstorms,dustconcentrationsmayreach500mg/m³.Particlesizesareasfollows:

95%ofallparticlesarelessthan20micrometers50%ofallparticlesarelessthan1.5micrometers

Elementspresentindustincludecompoundsofcalcium,silicon,magnesium,aluminum,potassium,chloridesandsodium.Whenwetted(highhumidityconditions)thesecompoundsfunctionaselectrolytesandcanresultinseverecorrosion.

Otherpollutantspresentintheatmosphereunderthemostextremeconditionsare:

H2S 20ppm(Vol/Vol)

Hydrocarbon 150ppm(Vol/Vol)

SO2 10ppm(Vol/Vol)

CO 100ppm(Vol/Vol)

NOx 5ppm(Vol/Vol)

O3 1ppm(Vol/Vol)

Wind-borneSeaWaterSpray

Equipmentinstalledoffshoreornearshore(i.e.,within0.5kmfromshoreline),shallbesuitedfortheharshenvironment(NEMA4Xenclosure,316SSTexternals,hermiticallysealed,etc.).

GeneralRequirements

LocalZVControl

Eachp aticallyoperatedZVshallbeprovidedwithlocalcontrolsthatpermittheZVtobeoperatedintheeventofanemergencyandtobereturnedtothenormaloperatingpositionlocallywhentheemergencyconditionshavereturnedtonormal,tripinitiatorsarehealthy,andthelogicsystemhasbeenreset(ready-to-resetlightenergized).

LocalZVReset

ResettingtheESDsystemlogicviatheremotepushbuttoninthecontrolroomshallnotcausetheassociatedZV'stoautomaticallyreturntotheirnormaloperatingposition.Manual'local'operatorinterventionisrequiredtoverifyconditionsinthefieldpriortoresettingaZV,followingatrip.

Inhigh-pressureapplications(GOSPinlet,etc.),theESDsystemshallpreventtheZVfromopeninguntilthepressuredifferentialacrossthevalvehasreachedasafelevel(viadifferentialpressureESDinput).

SmartZVLocalControlSystem

TheSmartZVsystemshallbecomprisedofaLocalControlPanel(LCP),asmartvalvepositioner,solenoidvalves,anESDHARThandheldcommunicator(orequalcomputerbasedconfiguration),andassociatedESDI/Oasoutlinedinsection6.6andshowninLibraryDrawingDB-950106,Sheets1and2.Inaddition,whenrequestedbythe

proponent,HARTsignalsplitters/multiplexerswithintheESDsystemmarshallingcabinetsshallbeprovidedtofacilitateintegrationwithandvendorspecificvalvediagnosticsoftware.

LocalControlPanel(SmartZV)

EachSmartZVshallbeequippedwithalocalcontrolpanel(LCP)topermittheZVtobeoperatedlocallyintheeventofanemergency,tobereturnedtothenormaloperatingpositionwhenthetripinitiatorsarehealthy,andtofacilitatefunctionaltestingoftheZV.

SmartZVLCPPushbuttons

ASmartZVLCPshallincludethreepushbuttons:1)valveclose,

2)valveopen,and3)test.

Thelocalpushbuttonsshallbeshroudedtopreventunintendedactuation.

CommentaryNote:

TheSmartZVLCPpushbuttonsarecloselyintegratedwithESDsystemlogicandthecontrolelementsmountedonthevalve(smartvalvepositioner,solenoidvalves,andlimitswitches).

ValveClosePush-button

Amomentarycontactpushbuttontoclosethevalveshallbeprovided.ThelocalvalveclosepushbuttoncontactsshallopenonactuationandshallbehardwiredasadiscreteinputtotheESDsystem.TheESDlogicandoutputsshalldrivethevalvetotheclosedpositionwhenthelocalclosepushbuttonisactivatedattheLCP.

ValveOpenPush-button

Amomentarycontactpushbuttontoopenthevalveshallbeprovided.ThelocalvalveopenpushbuttoncontactsshallcloseonactuationandshallbehardwiredasadiscreteinputtotheESDsystem.TheESDlogicandoutputsshalldrivethevalvetotheopenpositionwhenthelocalopenpushbuttonisactivatedattheLCP.

TestPush-button

Amomentarycontactpushbuttontoinitiateapartial-stroketestshallbeprovided.Thelocaltestpushbuttonshallcloseon

actuationandshallbehardwiredfromtheLCPdirectlytothesmartvalvepositioner(shallinitiatetheuserdefinedpartialstroketestresidinginmemorywithinthesmartvalvepositioner).

SmartZVLCPIndicationLamps:

TheLCPshallincludea"ready-to-reset"indicationlamptoprovidelocalindicationwhentheZVmaybereturnedtothenormaloperatingpositionfollowinganESDsystemtrip.The"ready-to-reset"lampshallbepoweredviaadiscreteoutputfromtheESDsystem.

CommentaryNote:

Ready-to-Resetlight:ThelampshallilluminatewhenallrelevantESDinputsareinthehealthyconditionandthelogicsystemhasbeenreset.Thelampshallextinguishwhenthevalvemovesfromthefail-safeposition.

WhenspecifiedonForm8020-634-ENG,localZVopenandclosedvalvepositionindicationlampsshallbeincludedwithintheLCP.

LEDtypelightsshallbeprovided(e.g.,Stahl8010/2-01orequal).

ColorsusedshallbeOpen–Green,Closed–Red,andReadytoReset–Amber.

LightsshallberemovableandreceablewhiletheZVison-line(inservice).

LocalControlPanelTerminations

TerminalstripswithintheZVLCPshallbeadequaysizedtoalloweasyaccesstotheterminations(hinged"swing-out"spacesaver,doubleortriplegangtypeterminationsarenotallowed).

TheLCPenclosureshallbeadequaysizedtoalloweasyterminationofexternalcablesandincludespaceforthelayofconductors.

LocalControlPanelVent/Drain

Acombinationvent/drainfittingshallbeprovidedoneachLCP.

SmartValvePositioner

AZVwillbemade"smart"bytheintroductionofasmarectro-p aticvalvepositioneraspartofthevalveassembly(FisherRosemountDVC6000orapprovedequalwithexternalsolenoidvalve).

ThesmartvalvepositionershallbemountedontheZVactuatortofacilitateon-line,partialstroke(limitedtravel)testing,full-strokeout-of-servicetesting,andself-healthmonitoringviathesmartvalvepositionerdiagnosticsoftware.

Thepositionershallbeinstalledinserieswithsolenoidvalve(s).

ThesmartvalvepositionershallcommunicatewiththeESDsystemviaadedicated4-20maDC/HARThybridESDoutputchannel.Intheeventofatrip,thesolenoidvalvewillchangestate(de-energize)andthepositionersignal

(4-20mADC)shallbedriventotheuserdefinedvalue.

SmartValvePositionerMountingKit

EachSmartZVpositionershallbedwithanactuatormountingkitdesignedspecificallyforuseontheintendedactuator.Ea ountingkitshallincludeprovisionsforvalvepositionlimitswitches(valveopenandvalveclosed).Hermeticallysealedortotallyencapsulated,mechanicalswitchorproximitysensorpositionswitcheswithcontactsratedfortherequiredloadshallbespecified.

On-lineTesting

EachSmartZVshallbeequippedwithaLCPasdescribedaboveinSection6.1.Inadditiontotheopenandclosepushbuttons,a"valvetest"pushbuttonshallbeincludedtoinitiatethepredefinedpartialstroketest(residinginmemorywithinthesmartvalvepositioner).

InadditiontotheLCP"test"pushbutton,on-linetestingofaSmartZVmaybeinitiatedviaHARTprotocolusingalaptopcomputerwithvendorspecifiedvalvetestinganddiagnosticsoftware.Remotepartial-stroketestingofZVsmayalsobe plishedbyusing'HART'multiplexedexternaloutputterminationmodulesorassemblieswithanassociatedZVmaintenanceworkstation.

CommentaryNote:

TheselectionandloadingoftheMultiplexersandHARTfiltersdwithESDmarshallingterminationstointegratethehybridHART og4-20mAsignaltothesmartvalvepostioner,shallbeguaranteedbytheESDvendorforproperoperationwiththeESD ogI/Ocardandthesmartvalvepositioner.

SolenoidValve(s)

ThesolenoidvalvesutilizedwithSmartZV'sshallbeelectro-p aticdirectoperatingorexternalpilottype(capableofoperatingwithoutapplieddifferentialpressure).Theyshallbeusedtopressurize/venttheactuatorinresponsetoanESDtripinafail-safearrangementwiththesmartvalvepositioner.AllsolenoidvalvesshallbespecifiedwithVitoninternals.

ReferenceLibraryDrawingDB-950106,Sheet1and2fortheEmerson/FisherDVCbasedSmartZVarchitecture.

ESDI/O

TheSmartZVisanintegrationoflocalcontrolsmountedontheZV(smartvalvepositioner,solenoidvalves,limitswitches,etc.),theLCP,andESDsystemI/Oandlogic.TheESDI/OrequiredtointegrateaSmartZVissummarizedinthetablebelow.

SmartZVESDI/ORequirements

ESDInputs/Outputs

Type

Description

DiscreteInput-1

LimitSwitch-ZVvalveopen

UsedwithinESDlogictomonitorZVposition.

DiscreteInput-2

LimitSwitch-ZVvalveclosed

UsedwithinESDlogictomonitorZVposition.

DiscreteInput-3

Pushbutton–ZVvalveopen

ThispushbuttonislocatedontheLCP.

DiscreteInput-4

Pushbutton–ZVvalveclose

ThispushbuttonislocatedontheLCP.

DiscreteOutput-1

SolenoidValve(s)

Provideshighvalveflowcoefficient(Cv)tomeetZVclosuretimerequirementandprovidestheprimaryESDfunction.

Note:ThesmartvalvepositionerwillalsomovethevalvetothefailsafepositionshouldthesolenoidfailtooperateduringanESDtrip.

OndoubleactingZV'swheretwosolenoidsareused,andtheyarebothcontrolledbythisone(1)ESDoutput.

DiscreteOutput-2

IndicationLamp-ReadytoReset(Ambercolor)

ThisIndicationLampislocatedinthelocalcontrolpanel(LCP).

ProvideslocalindicationattheZVwhentheESDhasbeenresetinthecontrolroomandallpermissivesaremet.OnlythenmaytheZVbesafelyreturnedtothe"normaloperatingposition."

DiscreteOutput–3OPTIONAL

IndicationLamp–ValveOpen(Greencolor)

ThisindicationLampislocatedinthelocalcontrolpanel(LCP).

ProvideslocalindicationattheZVwhenthevalveisfullyopen(viahardwiredlimitswitchtoESDdiscreteinput).

Responsibility:InstrumentationIssueDate:21December2005

34-SAMSS-634

Next

nnedUpdate:1January2011

LocalZVControlSystems

Page

PAGE

10

of

NUMPAGES

12

ESDInputs/Outputs

Type

Description

DiscreteOutput–3OPTIONAL

IndicationLamp–ValveClosed(Redcolor)

ThisindicationLampislocatedinthelocalcontrolpanel(LCP).

ProvideslocalindicationattheZVwhenthevalveisfullyclosed(viahardwiredlimitswitchtoESDdiscreteinput).

ogOutput–1

ZVpositioner

ogoutput(4-20mA)toSmartValvePositioner.

ThissignalprovidesabackupmeanstodrivetheZVtothefail-safepositionshouldtheprimaryESDdevice(solenoidvalve)failtofunction.

MultiplexedESDI/OisrequiredtoutilizeHARTdiagnosticinformationavailabletoaValvLinkworkstation.

Field'Test'Pushbutton

Type

Description

LocalControlPanelZV"Test"Pushbutton

Pushbutton–InitiatePartialStrokeTest

LCPZVTestpushbuttonishardwireddirectlytothesmartvalvepositioner.

LocalTestpushbuttoninitiatesthepredefined"partialstroke"test.Thesmartvalvepositionersavesthemostrecentvalvetestsignature.

LocalZVShutdownCabinets

WhenSmartZVlocalcontrolsarenotsuitedtotheapplication(e.g.,gasoperatedvalves),localZVshutdowncabinetsshallmeetthedesignrequirementsofthisspecification,SaudiAramcoForm8020-634-ENG,andtheapplicableSaudiAramcoLibraryDrawing(DB-950129orDA-950065).

Alternativedesignsshallonlybeusedwhenpre-approvedbytheManager,ProcessandControlSystemsDepartment.

Installation

Tubingshallbeseamless,316stainlesssteel.Theminimumtubesizeshallbe½inch(12.7mm)O.D.andhaveaminimumwallthicknessof0.03inch(0.75mm).

Exception:

Non-flowingp atictubingsuchaspilotoperatedsolenoidvalveimpulselinesmaybe¼inch(6.35mm)O.D.

Fittingsshallbe316stainlesssteelcompressiontypeSwagelok,Parker,orequal.Threadedconnectionsshallbesealedusingpaste.

Tubingshallbebentusingatubingbender,reamedandinternallycleanedpriortoinstallation.

Pressuregaugesindicating ingsupplypressureandoperatingpressuretothevalveactuator(openandclosedsideofdualactingandopensideofsingleactingactuators)shallbeprovidedinSIorEnglishunitsconsistentwiththeunitconventionusedintheintendedntlocation.

ElectricalInstallation

AllmaterialsandequipmentshallmeetNFPA70,NationalElectricalCoderequirementsfortheintendedhazardousareas.

Allcomponents(solenoidvalves,limitswitches,indicationlights,etc.,shallbecertifiedforuseintheintendedhazardousareabyanapprovedtestingagencywithouttheneedforanyadditionalexternalprotection.BothEExandAExCertifieddevicesareacceptable.

ElectricalwiringandinstallationshallconformtotherequirementsoftheNFPA70,NationalElectricalCode,latestedition.WiringinternaltotheLCPandlocalZVshutdowncabinetshallbe18AWGminimum.

Wireendsshallconnecttopolyamideterminalswithinthecabinet.TerminalmakeshallbeKlippon,Weidmuller,orequal.

Nametes

NametesshallfollowISARP60.6guidelines.

AllinstrumentsmountedinsidelocalZVshutdowncabinetsorassociatedwithSmartZVsystems,shallbeidentifiedbyanameteincludingthetagnumberandservicedescription.

Thenametesshallbeattachedwithstainlesssteelscrewsorstainlesssteelwire.

Nametesshallbem

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论