版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
...2.1TransferringresultsbetweenAbaqusanalyses:overview
Products:Abaqus/StandardAbaqus/ExplicitAbaqus/CAEReferences"TransferringresultsbetweenAbaqus/ExplicitandAbaqus/Standard,""TransferringresultsfromoneAbaqus/Standardanalysistoanother,""TransferringresultsfromoneAbaqus/Explicitanalysistoanother,"\t"v610keywin"*IMPORT\t"v610keywin"*IMPORTELSET\t"v610keywin"*IMPORTNSET\t"v610keywin"*IMPORTCONTROLS\t"v610keywin"*INSTANCE\t"v610usiwin""TransferringresultsbetweenAbaqusanalyses,"Section16.6oftheAbaqus/CAEUser'sManualOverview
AbaqusprovidesthecapabilitytoimportadeformedmeshanditsassociatedmaterialstatefromAbaqus/StandardintoAbaqus/Explicitandviceversa.Thiscapabilityisparticularlyusefulinmanufacturingproblems;forexample,theentiresheetmetalformingprocess<whichrequiresaninitialpreloading,forming,andsubsequentspringback>canbeanalyzed.InthiscasetheinitialpreloadingcanbesimulatedwithAbaqus/StandardusingastaticprocedureandthesubsequentformingprocesscanbesimulatedwithAbaqus/Explicit.Finally,thespringbackanalysiscanbeperformedwithAbaqus/Standard.AbaqusalsoprovidesthecapabilitytotransferdesiredresultsandmodelinformationfromanAbaqus/StandardanalysistoanewAbaqus/StandardanalysisorfromanAbaqus/ExplicitanalysistoanewAbaqus/Explicitanalysis,whereadditionalmodeldefinitionsmaybespecifiedbeforetheanalysisiscontinued.Forexample,duringanassemblyprocessananalystmayfirstbeinterestedinthelocalbehaviorofaparticularcomponentbutlaterisconcernedwiththebehavioroftheassembledproduct.InthiscasethelocalbehaviorcanfirstbeanalyzedinanAbaqus/StandardorAbaqus/Explicitanalysis.Subsequently,themodelinformationandresultsfromthisanalysiscanbetransferredtoasecondAbaqus/StandardorAbaqus/Explicitanalysis,whereadditionalmodeldefinitionsfortheothercomponentscanbespecified,andthebehavioroftheentireproductcanthenbeanalyzed.Forthiscapabilitytowork,thesamereleaseofAbaqus/ExplicitandAbaqus/Standardmustberunoncomputersthatarebinarycompatible.ABAQUS可以从隐式计算结果到显示计算进行分析,,该问题在求解一些问题是非常有用的,例如薄钢的锻造过程〔经历预加载,成形和回弹,该分析预加载可以通过std分析,锻造过程可以通过XPT进行分析,最后回弹可以再用std进行分析。ABAQUS也提供了从隐式分析到隐式分析和从显示分析到显示分析,例如可以先对感兴趣的局部构件进行分析,分析完成后,在对整个结构作分析,前部的分析结果可以传到后面的整体分析中。Savingtheanalysisresults
TherestartfilesfromtheoriginalanalysiscontaintheanalysisresultsthataretransferredfromAbaqus/StandardorAbaqus/Explicit.Obtainingrestartfilesisdescribedinmoredetailin"Writingrestartfiles"in"Restartingananalysis,";briefsummariesareprovidedbelow.Bydefault,Abaqus/StandarddoesnotwriteanyrestartinformationandAbaqus/Explicitwritesresultsatthebeginningandendofeachstep.SavingresultsfromAbaqus/StandardIftheresultsaretobeimportedfromanAbaqus/Standardanalysis,theresultsfromtheoriginalAbaqus/Standardjobmustbewrittentotherestart<.res>,analysisdatabase<.mdland.stt>,part<.prt>,andoutputdatabase<.odb>files.Youcanspecifytheincrementsatwhichrestartinformationwillbewritten.RestartinformationisalwayswrittenattheendofastepinadditiontotherequestedincrementswheneveryourequestrestartdatainAbaqus/Standard.InputFileUsage:\t"v610keywin"*RESTART,WRITE,FREQUENCY=n保存分析结果重启动文件包含了之前分析的信息,关于重启动的描述参阅"Writingrestartfiles"in"Restartingananalysis,";下面做简要介绍,默认情况下,std不保存重启动文件,xpt在每个分析部开始和结束步保存重启动文件。Std结果保存如果想从std分析后获得结果,原始的std分析必须保留重启文件〔.res,分析数据<.mdland.stt>,PART<.prt>,和输出数据<.odb>文件,用户可以指定具体的重启位置,重启信息除了在请求的位置输出外在每一分析步的最后也将输出。InputFileUsage:\t"v610keywin"*RESTART,WRITE,FREQUENCY=nAbaqus/CAEUsage:Stepmodule:OutputRestartRequests:enternintheFrequencycolumnforeachstepXpt结果保存如果想要从某一时刻输入xpt分析的结果,则必须在原始的结果文件中保存.abq状态文件,状态文件重启文件数据文件,PART文件和结果文件共同用来从xpt分析后的结果作为输入。可以具体指定是否精确的时间输出xpt重启文件,因为xpt会在每个分析步的最后给出重启文件。InputFileUsage:Usethefollowingoptiontorequestresultsattheincrementsendingimmediatelyaftereachtimeinterval:\t"v610keywin"*RESTART,WRITE,NUMBERINTERVAL=n,TIMEMARKS=NOUsethefollowingoptiontorequestresultsattheexacttimeintervals:\t"v610keywin"*RESTART,WRITE,NUMBERINTERVAL=n,TIMEMARKS=YESAbaqus/CAEUsage:Stepmodule:OutputRestartRequests:enternintheNumberIntervalcolumn;clicktochecktheTimeMarkscolumnforeachstepifyouwanttheresultswrittenattheexacttimeintervalsSavingresultsfromAbaqus/ExplicitIftheresultsaretobeimportedfromanAbaqus/Explicitanalysis,theresultsfromtheoriginalAbaqus/Explicitjobmustbewrittentothestate<.abq>fileatthetimewhentransferofthestateofthedeformedbodyisrequired.Thestate<.abq>,restart<.res>,analysisdatabase<.stt>,package<.pac>,part<.prt>,andoutputdatabase<.odb>fileswillbeusedforimportingtheresultsfromAbaqus/Explicit.Youcanspecifywhethertheresultsaretobewrittenattheexacttimedictatedbythespecifiedtimeinterval,n,duringastepofanAbaqus/Explicitanalysisorattheincrementendingafterthetimedictatedbythespecifiedtimeinterval.Resultsarealwayswrittenattheendofastep,soitisnotnecessarytorequestresultsattheexacttimeintervalsifresultswillbereadonlyfromtheendofastep.InputFileUsage:Usethefollowingoptiontorequestresultsattheincrementsendingimmediatelyaftereachtimeinterval:\t"v610keywin"*RESTART,WRITE,NUMBERINTERVAL=n,TIMEMARKS=NOUsethefollowingoptiontorequestresultsattheexacttimeintervals:\t"v610keywin"*RESTART,WRITE,NUMBERINTERVAL=n,TIMEMARKS=YESAbaqus/CAEUsage:Stepmodule:OutputRestartRequests:enternintheNumberIntervalcolumn;clicktochecktheTimeMarkscolumnforeachstepifyouwanttheresultswrittenattheexacttimeintervals指定模型数据的传递和结果下面讲解如何指定具体的输入请求,从一个模型数据和结果输入到另一个模型数据和结果,用户可以输入从没有被定义成装配件的实例的elementset,或者可以输入part实例从已经定义成装配件实例的part实例。在CAE里面仅仅能从装配件的构件实例中输入模型。指定从elementset中输入数据和结果。输入的例子参见\t"v610exawin""Springbackoftwo-dimensionaldrawbending,"Section1.5.1oftheAbaqusExampleProblemsManual,and\t"v610exawin""Axisymmetricformingofacircularcup,"Section1.3.7oftheAbaqusExampleProblemsManual。InputFileUsage:Usethefollowingoptiontoimportelementsetsfromapreviousanalysis:\t"v610keywin"*IMPORTlistofelementsetsthataretobeimported为了阻止模棱两可的单元和节点,*import必须在定义额外模型数据前指定,另外*import只能指定一次每个elementset的名字在*import输入行必须在原始文件的截面定义中使用过,〔e.g.*solidsection,elementset仅能包含不超过三种类型的单元。在CAE里面只能从PARTINSTANCES里面输入结果和数据如果输入的超过一个partinstance,partinstance必须从一个结果文件里输入且输入的参数必须和输入文件partinstances里面的一致,每个instance的名字应该保持一致,只有importinstance里面的sets才能被输入,sets在assemblies定义的必须在import分析中重新定义,重新定义的sets不能修改输入的新截面,材料的方向,法线,和梁方向InputFileUsage:Usethefollowingoptionstoimportapartinstancefromapreviousanalysis:\t"v610keywin"*INSTANCE,INSTANCE=instance-nameAdditionalsetandsurfacedefinitions<optional>\t"v610keywin"*IMPORT\t"v610keywin"*ENDINSTANCEAbaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:selecttheinstancestowhichtheinitialstateshouldbeassignedSpecifyingthetransferofmodeldataandresults
Theimportcapabilityisusedtotransfermodeldataandresultsfromoneanalysistoanother.Thefollowingsectionsdescribehowtospecifytheimportrequest.Youcanimportelementsetsfrommodelsthatarenotdefinedasassembliesofpartinstances,oryoucanimportpartinstancesfrommodelsthataredefinedasassembliesofpartinstances.InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.SpecifyingthetransferofmodeldataandresultsformodelsthatarenotdefinedasassembliesofpartinstancesYoucanimportelementsetsfromapreviousanalysistospecifythetransferofmodeldataandresultsformodelsthatarenotdefinedasassembliesofpartinstances.Thisimportcapabilityisillustratedin\t"v610exawin""Springbackoftwo-dimensionaldrawbending,"Section1.5.1oftheAbaqusExampleProblemsManual,and\t"v610exawin""Axisymmetricformingofacircularcup,"Section1.3.7oftheAbaqusExampleProblemsManual.InputFileUsage:Usethefollowingoptiontoimportelementsetsfromapreviousanalysis:\t"v610keywin"*IMPORTlistofelementsetsthataretobeimportedTopreventanyambiguityregardingelementandnodedefinitions,the\t"v610keywin"*IMPORToptionmustbespecifiedbeforeanyoptionsthatdefineadditionalmodeldataintheinputfile.Inaddition,the\t"v610keywin"*IMPORToptioncanbespecifiedonlyonce.Eachelementsetnamespecifiedonthedatalineofthe\t"v610keywin"*IMPORToptionmusthavebeenusedinasectiondefinitionoption<e.g.,\t"v610keywin"*SOLIDSECTION>intheoriginalanalysis.Anelementsetcancontainnomorethanthreedifferenttypesofelements.Abaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.SpecifyingthetransferofmodeldataandresultsformodelsthataredefinedasassembliesofpartinstancesYoucanimportpartinstancesfromapreviousanalysistospecifythetransferofmodeldataandresultsformodelsthataredefinedasassembliesofpartinstances.Ifyouimportmorethanonepartinstance,thepartinstancesmustbefromthesameoutputdatabase<.odb>fileandallimportparametersmustbethesameforeachimportedpartinstance.Eachinstancenamethatyouspecifymustbethesameastheinstancenameintheoriginalanalysis.Onlysetsthataredefinedwithintheimportedinstancewillbeimported.Setsdefinedattheassemblylevelmustberedefinedintheimportanalysis.Newsetdefinitionsandsurfacedefinitionscanbeaddeduponimport.Youcannotassignnewsections,materialorientations,normals,orbeamorientationstotheimportedpartinstance.InputFileUsage:Usethefollowingoptionstoimportapartinstancefromapreviousanalysis:\t"v610keywin"*INSTANCE,INSTANCE=instance-nameAdditionalsetandsurfacedefinitions<optional>\t"v610keywin"*IMPORT\t"v610keywin"*ENDINSTANCEAbaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:selecttheinstancestowhichtheinitialstateshouldbeassignedIdentifyingtheanalysisfromwhichthedatawillbeobtainedYoumustspecifythenameofthejobfromwhichthemodelandresultsdatawillbeobtained.InputFileUsage:Forallmodelsyoucanenterthefollowinginputonthecommandline:abaqusjob=job-nameoldjob=oldjob-nameIftheoldjobparameterisomitted,Abaquswillpromptforthejobname<see"Abaqus/Standard,Abaqus/Explicit,andAbaqus/CFDexecution,">.Alternatively,formodelsdefinedasassembliesofpartinstances,youcanusethefollowingoption:\t"v610keywin"*INSTANCE,LIBRARY=oldjob-nameIfyouimportmorethanonepartinstance,theoldjob-namespecifiedbytheLIBRARYparametermustbethesameforeachimportedpartinstance.Ifthejobnameisspecifiedonthecommandlineusingtheoldjoboption,thecommandlinespecificationwilltakeprecedenceovertheLIBRARYparameter.Abaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:Jobname:output-database-name从包含的数据文件中指定分析数据必须具体制定包含数据和结果文件的名字InputFileUsage:Forallmodelsyoucanenterthefollowinginputonthecommandline:ImportingmodeldataElementpropertydefinitionsofimportedelementscanberedefinedonlyifthereferenceconfigurationisupdated<see"Updatingtheimportedconfiguration">andthematerialstateisnotimported<see"Importingthematerialstate">.Inthiscasethematerialorientationdefinitions<"Orientations,">,hourglassstiffnessbutnothourglasscontroldefinitions,andtransverseshearstiffnessdefinitions<inthecaseofshellelements>oftheimportedelementscanalsoberedefined.Forotherreferenceconfigurationandmaterialstatecombinations,theinformationrequiredtodefinethesectionforeachimportedelementwillbeimportedfromtheoriginalanalysis.Materialorientationscannotberedefinedintheimportanalysis;orientationnamescannotbereusedintheimportanalysis.Forimportedelements,thematerialorientationswillbetransferredfromtheoriginalanalysis.Transverseshearstiffnessforimportedshellelementscannotberedefined;thevalueswillbetransferredfromtheoriginalanalysis.HourglassstiffnessfortheimportedelementscannotberedefinedinanAbaqus/Standardimportanalysis;thedefaultvalueswillbeused.Thesectioncontroldefinitions<kinematicformulation,orderofaccuracyintheelementformulation,andhourglasscontrolapproach>tobeusedforimportedelementscannotberedefined<see"TransferringresultsbetweenAbaqus/ExplicitandAbaqus/Standard,",fordetails>.Onlynodesassociatedwiththeimportedelementsareimported.Newnodescanbedefinedintheimportanalysis.Nodesorelementsthatusethesamenumbersasnodesorelementsbeingimportedcanbedefinedprovidedthatthereferenceconfigurationisupdated,thematerialstateisnotimported,andtheimportisnotdonefromaninstancelibrary.Thenewdefinitionswilloverwritetheimporteddefinitions.Ifthereferenceconfigurationisnotupdated,newnodesorelementscannotusetheimportednodeandelementnumbersirrespectiveofwhetherornotthematerialstateisimported.DuringresultstransferfromanAbaqus/StandardanalysistoanotherAbaqus/StandardanalysisorfromanAbaqus/ExplicittoanotherAbaqus/Explicitanalysis,thecoordinatesofimportednodescanbemodifiedfromtheirimportedvaluesbyrespecifyingthenodaldefinitionsifthereferenceconfigurationisupdatedandthematerialstateisnotimported.ThismodificationofthecoordinatesofimportednodesisnotallowedduringtransferofresultsfromAbaqus/ExplicittoAbaqus/Standardorviceversa.ImportingmodeldatadefinedbyadistributionWhiletransferringresultsfromoneAbaqus/StandardanalysistoanotherAbaqus/Standardanalysis,mostelementormaterialpropertiesdefinedbyadistribution<see"Distributiondefinition,">areimportedalongwiththeelements.Theonlyexceptionsarespatiallyvaryingthicknessesandorientationanglesdefinedonthelayersofcompositeshellsandsolids;inthiscaseAbaqusissuesanerrormessageduringinputfilepreprocessing.WhiletransferringresultsfromanAbaqus/ExplicitanalysistoanAbaqus/Standardanalysis,theonlyspatiallyvaryingelementpropertiesdefinedbyadistributionthatcanbeimportedareshellthicknessesandsectionorientationsforshellandsolidelements.Ifanyotherelementormaterialpropertiesaredefinedwithadistribution,Abaqusissuesanerrormessageduringinputfilepreprocessing.WhiletransferringresultsfromanAbaqus/StandardanalysistoanAbaqus/ExplicitanalysisorfromanAbaqus/ExplicitanalysistoanotherAbaqus/Explicitanalysis,theonlyspatiallyvaryingelementpropertiesdefinedbyadistributionthatcanbeimportedareshellthicknesses,sectionorientationsforshellandsolidelements,orientationanglesdefinedonthelayersofcompositeshells,andsectionstiffnessmatricesspecifieddirectlyforgeneralshellsections.Ifanyotherelementormaterialpropertiesaredefinedwithadistribution,Abaqusissuesanerrormessageduringinputfilepreprocessing.ImportingresultsfromanAbaqus/Standardanalysis<otherthanadirectcyclicanalysis>IftheresultsareimportedfromanAbaqus/Standardanalysis,youcanspecifythestepandincrementintherestartfileforwhichtheresultsaretobeimported.Bydefault,theresultswrittenattheendoftheanalysisareimported.InputFileUsage:\t"v610keywin"*IMPORT,STEP=step,INCREMENT=increment
Formodelsthataredefinedasassembliesofpartinstances,the\t"v610keywin"*IMPORToptionmustappearwithinapartinstancedefinition.Abaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:selectinstances:Step:selectSpecify:stepandFrame:selectSpecify:incrementImportingresultsfromanAbaqus/StandarddirectcyclicanalysisIftheresultsareimportedfromadirectcyclicanalysis,youcanspecifythestepanditerationnumberintherestartfileforwhichtheresultsaretobeimported.Bydefault,theresultswrittenattheendoftheanalysisareimported.InputFileUsage:\t"v610keywin"*IMPORT,STEP=step,ITERATION=iteration
Formodelsthataredefinedasassembliesofpartinstances,the\t"v610keywin"*IMPORToptionmustappearwithinapartinstancedefinition.Abaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:selectinstances:Step:selectSpecify:stepandFrame:selectSpecify:iterationImportingresultsfromanAbaqus/ExplicitanalysisIftheresultsareimportedfromanAbaqus/Explicitanalysis,youcanspecifythestepandintervalinthestatefileforwhichtheresultsaretobeimported.Bydefault,theresultswrittenattheendoftheanalysisareimported.InputFileUsage:\t"v610keywin"*IMPORT,STEP=step,INTERVAL=interval
Formodelsthataredefinedasassembliesofpartinstances,the\t"v610keywin"*IMPORToptionmustappearwithinapartinstancedefinition.Abaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:selectinstances:Step:selectSpecify:stepandFrame:selectSpecify:intervalUpdatingtheimportedconfigurationOncethecurrentmodelconfigurationofanAbaqusanalysisisimportedintoAbaqus/ExplicitorAbaqus/Standard,theanalysiscanbecontinuedwithorwithoutupdatingthereferenceconfigurationtobetheimportedconfiguration.Ifthereferenceconfigurationisnotupdatedtobetheimportedconfiguration,thedisplacementsandstrainsarereportedastotalvaluesrelativetotheoriginalreferenceconfigurationandwill,hence,becontinuous.Ifthereferenceconfigurationisupdatedtobetheimportedconfiguration,displacementsandstrainsreportedintheimportanalysisarethetotalvaluesrelativetotheupdatedreferenceconfiguration.Thischoiceisusefulifresultsneedtobedisplayedrelativetotheimportedconfiguration,suchasmaybedesirableinspringbackanalysis.Thereferenceconfigurationcannotbeupdatediftheimportedanalysisisgeometricallylinear.Ifconnectorelementsareimported,theconfigurationcanbeupdatedprovidedthatthestateisnotimported.InputFileUsage:Usethefollowingoptiontospecifythatthereferenceconfigurationistobeupdatedtotheimportedconfiguration:\t"v610keywin"*IMPORT,STEP=step,UPDATE=YESUsethefollowingoptiontospecifythatthereferenceconfigurationshouldnotbeupdatedtotheimportedconfiguration:\t"v610keywin"*IMPORT,STEP=step,UPDATE=NOFormodelsthataredefinedasassembliesofpartinstances,the\t"v610keywin"*IMPORToptionmustappearwithinapartinstancedefinition.Abaqus/CAEUsage:InAbaqus/CAEyoucanimportmodeldataandresultsonlyfrommodelsthataredefinedasassembliesofpartinstances.Loadmodule:CreatePredefinedField:Step:Initial:chooseOtherfortheCategoryandInitialStatefortheTypesforSelectedStep:toggleUpdatereferenceconfigurationonoroffImportingthematerialstateYoucanspecifywhetherornottheassociatedmaterialstateshouldbeimported.Ifyouchoosetoimportthematerialstate,thefollowingareimported:stresses;equivalentplasticstrains;backstressesforthekinematichardeningmodels;user-definedstatevariables;damage-relatedstatevariablesfortheconcretedamagedplasticitymodel;damage-relatedstate-variablesfortraction-separationresponsewithcohesiveelements;damage-relatedstatevariablesforductilemetals;damage-relatedstatevariablesforfiber-reinforcedcomposites;maximumdeviatoricstrainenergydensityduringdeformationhistoryforMullinseffect;internalstrainsandstressesforviscoelasticmaterialmodels;andconnectorstatevariablessuchasplasticstrains,frictionalslip,anddamagestate.Thus,thestateisimportedcorrectlyforfurtheranalysisonlyforthefollowing:linearelasticity,Misesplasticity<includingthekinematichardeningmodels>,extendedDrucker-Pragerplasticity,crushablefoamplasticity,Mohr-Coulombplasticity,criticalstate<clay>plasticity,castironplasticity,concretedamagedplasticity,hyperelasticity<includingMullinseffect>,hyperfoam,viscoelasticity,traction-separationresponsewithdamageforcohesiveelements,damageforductilemetals,damageforfiber-reinforcedcomposites,connectorbehavior,andmaterialsdefinedinusersubroutines\t"v610subwin"UMATand\t"v610subwin"VUMAT.Forallothermaterialmodelsonlystresseswillbeimported.Nootherstatevariableswillbeimported.Ifthematerialbehaviorisdefinedinausersubroutine,youmustensurethatthe\t"v610subwin"UMATand\t"v610subwin"VUMATareconsistent.Ifconnectorelementsareimported,thestatecanbeimportedprovidedthattheconfigurationisnotupdated.InputFileUsage:Usethefollowingoptiontospecifythatthematerialstateshouldbeimported:\t"v610keywin"*IMPORT,STATE=YESUsethefollowingoptiontospecifythatthematerialstateshouldnotbeimported:\t"v610keywin"*IMPORT,STATE=NOFormodelsthataredefinedasassembliesof
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 第十八章 医疗与护理文件课件
- 休学典礼发言稿
- 建设项目审计调查实施方案
- 维修协议劳务合同
- 第二章 抗体课件
- 第二章 光检基本原则课件
- Methyl-6-gingerol-生命科学试剂-MCE
- (新)换填土施工方案
- 教材编制与课程设计
- 教材同步书写课程设计
- 设备维保的现场维修与故障处理
- 平面镜成像-说课课件
- 宋代诗人苏轼的艺术心态与文学成就
- 虫害分析分析报告
- 湘少版五年级下册英语全期教案
- 中国的时尚与时尚产业
- 炊事基础理论知识
- 颅内占位性的病变护理查房课件
- 山东省烟台市芝罘区(五四制)2023-2024学年九年级上学期期末考试物理试题
- 女职工权益维护知识讲座
- DB14∕T 1851-2019 中华鼢鼠防治技术规程
评论
0/150
提交评论