PAGE空调制冷课程设计说明书二〇一五年一月目录1.工程概述 -1-2.设计依据 -1-2.1设计任务书 -1-2.2设计规范及标准 -1-3.设计范围 -1-4.设计参数 -1-4.1空调室外空气计算参数 -1-4.2室内空气设计参数及有关指标(见表2) -1-5.制冷空调方案选择 -2-5.1冷热源确定 -2-5.2空调系统方式确定 -2-6.风系统设计 -2-6.1房间气流组织方式 -3-6.2送、回风管的布置 -3-6.3风管材料和形状的确定 -3-6.4风口的选型 -3-6.4.1风机盘管加新风系统 -3-7.水系统设计 -3-7.1冷冻水系统设计 -5-7.1.1两管制系统的优点 -5-7.1.2闭式系统的优点 -5-7.1.3同程和异程系统的选择 -5-7.1.4一次泵定流量系统的选择依据 -5-7.2冷却水管路设计 -5-7.3冷凝水管路设计 -5-7.4补给水管路设计 -5-7.5定压罐设计 -6-8.管道保温设计的考虑 -6-8.1保温材料的选用 -6-8.2保温管道防结露 -6-8.3保温材料的经济厚度 -6-9.空调系统消声减振的设计方案 -6-10.设备明细表 -6-11.参考文献 -77-1.工程概述本工程地处北京,为一一般办公楼,占地面积1569.7256m2,共五层(包括一层底下室),室内地面标高±0.000,每层层高3.5m,地下室层高4.5m。市政给水干管已入户,水源充足;有380V和220V电源,且用电容量足够。拟采用风机盘管加独立新风系统,每层设有独立新风机组,主要设备放置在地下室专用机房。2.设计依据2.1设计任务书①甲方提供任务书②各房间空调系统设计③制冷机房设计2.2设计规范及标准《民用建筑供暖通风与空气调节设计规范》、《采暖通风与空气调节设计规范》、《暖通空调》(第二版)、《简明空调设计手册》、《实用供热空调设计手册》(第二版)3.设计范围①各房间空调系统设计②制冷机房设计4.设计参数4.1空调室外空气计算参数表1室外空气参数序号空气参数数值空气参数数值1夏季空调室外计算干球温度tw33.2℃夏季空调室外计算湿球温度ts26.4℃2夏季空调室外日平均温度twp28.6℃夏季通风室外计算温度29.9℃3冬季空调室外计算干球温度-12℃冬季通风室外计算温度-7.6℃4冬季室外计算相对湿度37%夏季室外计算相对湿度58%5夏季室外平均风速2.2m/s冬季室外平均风速2.7m/s6全年主导风向NNW冬季日照率14%4.2室内空气设计参数及有关指标(见表2)表2室内设计参数类型季节空调运行时间夏季新风量(m3/人.h)温度(℃)湿度(%)风速(m/s)夏季28650.3305.制冷空调方案选择选择空调系统时应根据建筑物的用途、规模、使用特点、负荷变化情况和参数要求、所在地区气象条件与能源状况等,通过技术经济比较确定。办公楼的空调形式一般采用风机盘管或风机盘管加新风系统,新风机组一般分层设置。餐厅等大空间一般采用全空气系统。风管尺寸按经济流速确定,同时考虑控制气流噪声要求。故本设计采用风机盘管加新风系统,新风机组分层设置。建筑物总冷负荷为236.54kW,总湿负荷为0.022kg/s,一层所需新风量为2640.24m3/h,二层所需新风量为2784.6m3/h,三层和四层所需新风量同为3240m3/h,总送风量为15.06kg/s。一、二层新风机组选用KG03D1Ⅱ-4Y-B,三、四层新风机组选用KG03.5D1Ⅱ-4Y-B,布置在楼道入口吊顶暗装;风机盘管选用FP系列,详细见平面图。如冷负荷、湿负荷、风量、设备型号及数量、管道尺寸和布置位置等。5.1冷热源确定螺杆式水冷冷水机组是冷凝器的冷却介质及载冷剂均为水的冷水机组,广泛应用于中央空调、工业冷却等各个领域,所以选择螺杆式水冷冷水机组。根据建筑物总冷负荷236.55kW选择两台HBW-290S型号冷水机组,其中一台备用,将其布置在地下室机房中。5.2空调系统方式确定本建筑物属于一般办公楼,而办公楼的空调形式一般采用风机盘管或风机盘管加新风系统,故选择风机盘管加新风系统,新风机组分层设置。6.风系统设计风系统设计包括新风系统和风机盘管系统,新风系统每层布置,风机盘管每间办公室布置一个,面积稍大的办公室布置两个。6.1房间气流组织方式办公室采用顶送风气流分布模式,即散流器平送,顶棚回风的气流分布模式。散流器底面与顶棚在同一平面上,送出的气流为贴附于顶棚的射流,工作区基本上处于混合空气中。6.2送、回风管的布置新风干管布置在楼道顶棚,支管由干管引出穿墙进入空调房间,送入风机盘管送风管内。风机盘管送风管布置在空调房间顶棚内。由于所选风机盘管自带回风口,故不再单独设回风管。6.3风管材料和形状的确定由于系统为低压空调系统,故采用金属矩形风管,根据技术经济比较采用镀锌钢板。6.4风口的选型6.4.1风机盘管加新风系统由于送风管道顶棚安装,所以选择顶送风口——平流型方形散流器,有多层同心的平行导向叶片,使空气流出后贴附于顶棚流动。水系统设计沿程阻力也称摩擦阻力,可按下式计算:。局部阻力。总阻力。但实际可用鸿业水力计算软件直接计算,计算结果见下表。水管水力计算表(一层)序号负荷(W)流量(L/s)管径管长(m)ν(m/s)R(Pa/m)△Py(Pa)ξ动压(Pa)△Pj(Pa)△Py+△Pj(Pa)157330.273925DN208.820.772590.4115207.4284298.2591193.0376400.46529007.20.430367DN253.60.752407.6711467.6162282.482564.9632032.579312377.70.591411DN323.60.589177.764639.9512173.557347.113987.064415748.20.752455DN323.60.75280.1491008.5352280.946561.8931570.428518349.20.876731DN407.90.664186.1651470.7034220.478881.912352.613657330.273925DN208.020.772590.4114735.0994298.2591193.0375928.13679007.20.430367DN253.60.752407.6711467.6162282.482564.9632032.579812330.90.589175DN323.60.587176.503635.4092172.247344.493979.902915654.60.747982DN323.60.745276.999997.1962277.617555.2331552.4291018928.80.904425DN403.650.685197.439720.6511234.626234.626955.2771121254.41.01554DN403.550.769245.939873.0834295.821183.2812056.364水管水力计算表(二层)序号负荷(W)流量(L/s)管径管长(m)ν(m/s)R(Pa/m)△Py(Pa)ξ动压(Pa)△Pj(Pa)△Py+△Pj(Pa)157330.273925DN208.820.772590.4115207.4284298.2591193.0376400.46529007.20.430367DN253.60.752407.6711467.6162282.482564.9632032.579312281.40.58681DN323.60.585175.173630.6232170.867341.733972.356415555.60.743252DN323.60.74273.686985.272274.116548.2331533.503518829.80.899695DN407.90.681195.491544.3714232.178928.7132473.08461591.20.0760281DN1550.39246.7931233.964376.137228.411462.37477324.20.349953DN2550.611275.8471379.2332186.78373.561752.793810598.40.506395DN323.60.504132.891478.4092127.245254.491732.9913922.10.665203DN323.60.663221.857798.6852219.569439.1381237.8231017245.80.82401DN403.60.624165.601596.1642194.759389.517985.68111209341.00023DN403.650.758238.947872.1551286.969286.9691159.1241222939.21.09604DN403.550.83284.3381009.4014344.5771378.3092387.71水管水力计算表(三层、四层)序号负荷(W)流量(L/s)管径管长(m)ν(m/s)R(Pa/m)△Py(Pa)ξ动压(Pa)△Pj(Pa)△Py+△Pj(Pa)157330.273925DN208.820.772590.4115207.4284298.2591193.0376400.46529007.20.430367DN253.60.752407.6711467.6162282.482564.9632032.579312281.40.58681DN323.60.585175.173630.6232170.867341.733972.356415555.60.743252DN323.60.74273.686985.272274.116548.2331533.503518829.80.899695DN403.60.681195.49703.7641232.178232.178935.942620512.80.980109DN402.510.742229.905577.0621275.537275.537852.59971732.50.0827795DN154.020.425288.7081160.606290.259180.5181341.124822245.31.06289DN401.80.805268.191482.7442324.046648.0921130.83691951.20.093229DN1550.479359.8351799.1733114.485343.4542142.627107324.20.349953DN2550.611275.8471379.2332186.78373.561752.7931110598.40.506395DN323.60.504132.891478.4092127.245254.491732.91213922.10.665203DN323.60.663221.857798.6852219.569439.1381237.8231317245.80.82401DN403.60.624165.601596.1642194.759389.517985.68114209341.00023DN403.650.758238.947872.1552286.969573.9381446.0931524622.21.17646DN401.750.891325.432569.5051396.994396.994966.499161732.50.0827795DN154.730.425288.7081365.589290.259180.5181546.1071726354.71.25924DN501.80.571100.234180.4212162.884325.768506.1897.1冷冻水系统设计7.1.1两管制系统的优点管网系统简单,占用空间少,初投资低。7.1.2闭式系统的优点闭式水系统不与大气相接触,仅在系统最高点设置膨胀水箱。管路系统不易产生污垢和腐蚀,不需克服系统静水压头,水泵耗电较小。7.1.3同程和异程系统的选择选择异程式水系统。异程式水系统管路简单,不需采用同程管,水系统投资较少,但水量分配、调节较难,如果系统较小,适当减小公共管路的阻力,增加并联支管阻力,并在所有盘管连接支管上安装流量调节阀平衡阻力,则亦可用异程式布置。7.1.4一次泵定流量系统的选择依据一次泵定流量系统的特点:是通过蒸发器的冷水流量不变,因此蒸发器不存在发生结冰的危险。当系统中负荷侧冷负荷减少时,通过减少冷水的供、回水温差来适应负荷的变化,所以在绝大部分运行时间内,空调水系统处于大流量、小温差的状态,不利于节约水泵的能耗。7.2冷却水管路设计压力回流式:水泵设置在冷水机组冷却水的入口管路上,经冷却塔冷却后的冷却水借水泵压力流经冷水机组,然后再进入冷却塔进行再冷却。冷凝器的承压为系统静水压力和水泵全压之和。7.3冷凝水管路设计①每层冷凝水集中回收后就近排至卫生间。②水平干管必须沿水流方向保持不小于2/1000的坡度;连接设备的水平支管,应保持不小于1/100的坡度。③冷凝水立管的顶部,应设置通向大气的透气管。④通常,根据冷负荷(kW)选择确定冷凝水管的公称直径DN(mm)。7.4补给水管路设计①空调水系统的补水,应经软化处理。补水软化处理系统宜设软化水箱,补水箱的贮水容积,可按补水泵小时流量的0.5~1.0配置。②循环水系统的补水点,宜设在循环水泵的吸入侧;当补水压力低于补水点的压力时,应设置补水泵。7.5定压罐设计可更换隔膜定压罐是稳定的供水系统中所必须的,特别是在平面面积和有限的供水网路中发挥不可替代的作用。定压罐的用途是在供水系统中在系统压力降低时补充一定的压力,使系统维持恒定的压力,同时减少水泵启动次数,延长设备使用寿命,降低电功耗。因此选择定压罐定压。8.管道保温设计的考虑8.1保温材料的选用
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年度文化旅游项目勘察施工与文化遗产保护合同
- 2025年度二零二五版开盘活动专业摄影摄像合同
- 二零二五年度女方离婚后共同债务分担合同
- 二零二五年度服务器租赁与数据中心安全评估协议3篇
- 二零二五年度林业产业项目融资合作协议3篇
- 现代服务业中企业社会责任的实践与价值
- 2025年新乡货运资格证培训考试题
- 2025年临沂考货运资格证考试内容
- 2025年西安货运资格证模拟考试卷
- 2025年福州货运从业资格证模拟考试下载什么软件
- 2025年湖南九嶷职业技术学院高职单招职业技能测试近5年常考版参考题库含答案解析
- 农产品贮运与加工考试题(附答案)
- 幼儿园开学教职工安全教育培训
- 学校财务年终工作总结4
- 钢铁是怎样炼成的钢铁读书笔记
- 2025年汽车加气站作业人员安全全国考试题库(含答案)
- 化工过程安全管理导则安全仪表管理课件
- 【化学】高中化学手写笔记
- 中国高血压防治指南-解读全篇
- 2024年监控安装合同范文6篇
- 2024年山东省高考政治试卷真题(含答案逐题解析)
评论
0/150
提交评论