力士乐泵课件_第1页
力士乐泵课件_第2页
力士乐泵课件_第3页
力士乐泵课件_第4页
力士乐泵课件_第5页
已阅读5页,还剩23页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、A10V(S)O Pressure/Flow control DFR(1) PortsPressure control DRStandard setting:A10VODFR/31: 280 barA10VODFR/52: 250 barFlow control FR(Dp = 10 - 22 bar)Standard setting: Dp = 14 bar X - Pilot pressure portPressure port BCase drain port LSuction port S(viewed A10VO, BR 31, clockwise)A10V(S)O Pressure

2、/Flow controlDamping orificePressure springControl piston (8)Flow control(Standard:Dp = 14 bar);Spring force (5)DecompressionorificeAdjustable orifice, (6) res.Mobile valve block (not included in supply)X - portA10V(S)O Pressure/Flow control DFR(1) Circuit diagram(Circuit diagram viewed for A10VO, s

3、eries 31)432791DRFRA10 146.1.e/VST6/H 01.AKBias piston and springDamping orificePressure springDamping orificePressure portControl pistonCounter balance piston and mechanical springFlow control(Standard:Dp = 14 bar);DecompressionorificeAdjustable orifice, res.Mobile valve block (not included in supp

4、ly)X - portA10V(S)O Pressure/Flow control DFR(1) Circuit diagram(Circuit diagram viewed for A10VO, series 31)DRFRA10 146.2.e/VST6/H 01.AKDamping orificePressure portCoA10V(S)O Pressure/Flow control DFR(1)Function and circuit diagramDRFRXOrifice res. Mobile valve blockDR - axisFR - axisLS - pilot pre

5、ssureXA10 146.3.e/VST6/H 01.AKA10V(S)O Pressure/Flow controlA10V(S)O Pressure/Flow control DFR(1) p - control characteristic f (x) = (px, Vg)A10 VO 74 DFR(1)Mode of experimental procedure:n = 1500 rpmp = 15 barStand by = 20 barp = 15 barHigh pressure: p HDSimulated load pressure: p XA10V(S)O Pressur

6、e/Flow controlA10V(S)O Pressure/Flow control DFR(1)Decompression orifice and damping orificeDFR with decompression orifice:(DFR: Standard: 0,35 mm)(DFR1: closed, without drilling)Damping orifice DR - FR(Standard: 0,6 mm,Slit in longitudinal direction: orifice opened Slit in cross direction : orifice

7、 closed, SO 74)FR - axisDR - axisDRFRXA10V(S)O Pressure/Flow controlA10V(S)O Pressure/Flow control DFR(1)Damping orificeDamping orifice DR - FR(Standard: 0,6 mm, Slit in longitudinal direction: orifice opened Slit in cross direction : orifice closed, (SO 74)A10V(S)O Pressure/Flow controlA10V(S)O Pre

8、ssure/Flow control DFR(1)Measurement of high pressureMeasurement high pressure:At this particular spot, the existing plugs (M8 x 1) canbe replaced by mini measure-ment connectionsAttention:The mini - measurement connection have to be shortened according to the original lenght of the plug(reach of a

9、screw 7 mm).A10 146.7.e/VST6/H 01.AKA10V(S)O Pressure/Flow controlA10V(S)O Pressure/Flow control DFR(1)Adjustment for pressure- res. flow controlValve axis:Flow controlAdjustment of flow control: Stand - by“ pressuremeasurementorDifferential pressuremeasurement with swivel angle !Adjustment of press

10、ure controlValve axis:Pressure controlA10V(S)O Pressure/Flow controlMeasuring - point 1: High pressure(measurable at plug of DR valve axis)A10V(S)O Pressure/Flow control DFR(1)Adjustment of pressure control DRDRFRProcedure: FR - flow control blocked ! High pressure line closed ! Adjusting of DR pres

11、sure control with setting value !XAdjustment DR : each rotation app. 50 bar ! - 50 bar + 50 barA10 146.9.e/VST6/H 01.AKMeasuring - point 1: High presMeasuring - point 1: zero stroke pressure(measurable at plug of valve axis)1. Stand by“ pressure measurement: A10V(S)O Pressure/Flow control DFR(1)Adju

12、stment of flow control FRDRFRProcedure: X - port unloaded to tank ! close high pressure port !XStandard adjustment FR Dp = 14 bar (When port X is unloaded to tank, a zero stroke pressure of p = 16 1 bar stand by“results. - 16 bar + 16 barMeasuring - point 1: zero stroMeasuring - point 1: load pressu

13、re corresponding to pressure of port X !( LS - signal )Measuring - point 2: High pressure(measureable at plug of valve axis)2. Possibility: Differential pressure measurement : A10V(S)O Pressure/Flow control DFR(1)Adjustment of flow control FRDRFRX - 16 bar + 16 barMeasuring - point 1: load presA10V(

14、S)O Pressure/Flow control DFR(1)Differences between DFR and DFR1DFR - designWith decompression orifice !(DFR: Standard: 0,35 mm glued in place, fastened with Loctide)DFR1 - designWithout decompression orifice !(DFR1: closed, without drilling)A10 146.12.e/VST6/H 01.AKA10V(S)O Pressure/Flow controlA10

15、V(S)O Pressure/Flow control DFR(1)Usage DFR(1) for series 31 and 52 !DRFRA10 - series 31:DFR(1) - without return line orifice !A10 - series 52:DFR(1) - with return line orifice (Standard: 2,2 mm !)Special design (Stabilization):SO 116: Return line orifice 1,3 mmSO 229: Return line orifice 1,5 mm SO

16、231: Return line orifice 2,2 mm SO 277: Return line orifice 1,0 mm SO 381: Return line orifice 0,8 mmSO 617: Return line orifice 0,6 mmXA10V(S)O Pressure/Flow controlA10V(S)O Pressure/Flow control DFR(1)Mounting of DFR(1) control (series 31)Mounting of DFR(1) - control (A10V(S)O series 31) depends o

17、ndirection of rotation (Direction of rotation by view on drive shaft) !A10V(S)O Pressure/Flow controlA10V(S)O Pressure/Flow control DFR(1)Different designsDFR(1) for A10V(S)OSize 18 - 100Standard design !DFR(1) for A10V(S)OSize 140Design in sandwich - platedesign !A10 146.15.e/VST6/H 01.AKA10V(S)O P

18、ressure/Flow controlPressure control DRStandard setting:A10V(S)O DFLR/31: 280 barFlow control FR(Dp = 10 - 22 bar)Standard setting: Dp = 14 bar X - Port(With integrated orifice (in adap-ter): 0,8 mm)Pressure port BCase drain port LSuction port S(viewed A10VO, series 31, clockwise)Power-control LRPor

19、tsA10V(S)O pressure, flow and power control DFLRPressure control DRFlow controA10V(S)O pressure, flow and power control DFLR Circuit diagramA10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Function and circuit diagramA10V(S)O pressure, flow and poA10V(S)O pressure, flow a

20、nd power control DFLR Function and circuit diagramA10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Function power controlAdjustable spring package of power control valveEccenter cradle position (i.e. displaced volume) will be restored by the eccenter prestress of the spri

21、ng package will be changed by the eccenter Thereby the opening pressure of the power control valve has been changed small swivel angle = high pressure large swivel angle = low pressureA10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Integrated orifice and damping orificeA

22、10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Measurement of high pressureMeasurement of high pressure:At this particular spot, the existing plugs (M8 x 1) canbe replaced by mini measure-ment connections.Attention:The mini - measurement connection have to be shortened a

23、ccording to the original lenght of the plug(reach of a screw 7 mm).A10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Adjustment of DR, FR and LR - controlValve axis:flow controlAdjustment ofpressure controlAdjustment offlow control: stand-by“ pres-sure measurementordiffere

24、ntial pressuremeasurement with semi swivel angle !Adjustment of power controlValve axis:pressure controlA10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Adjustment of power controlStart of control !Start of control is adjustable bythe first outer spring, prestressed at fu

25、lly displaced volume (100% Vg)End of control is adjustable by the second inner spring,clearance at fully displaced volume (100% Vg)torque04060802050100150200250280501001502000Q l/min pressure pHD bar drive torque Nm 00,40,61,00,2Vg / Vgmax0,8Point of action of thesecond inner springA10V(S)O pressure, flow and poA10V(S)O pressure, flow and power control DFLR Hints for assembling/disassembling of the LR valve1. : loosening the plugEccenter pin2. : by pushing the spring, the eccenter wil

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论