1、機密等級:機密USI Controlled DocumentConfidential Level: ConfidentialDocument Title(文件名稱) :Management Procedure of Golden Sample Golden Sample管理辦法Document Number(文件編號):AT-0801-E105Revision(文件版本):A6Revise Date:11/29Prepared by(撰寫者):Jack shenCreate by which Unit(制定單位) :GRM/GME/STEAG-0801-M006-F2 Rev.:A1Amend

2、ment RecordsItem:Date:Revision:Page:Change Description:Changed by:112/07/2004A1AllFirst draft.Eden Chu201/27/2005A26,12,17,23Add red label for bad golden sample.remark MSD PD1 280 power productsgolden sample control system.Belen Chen306/30/2006A134,35All add the field for the description of theFAULT

3、 golden sample. change the Doc. No. from AG-0801-P027 to AT-0801-E105 modify the flowchart correct the formatEmmitt Lee406/20/2008A21,33,3435,36,37 define the duration and verification of Golden Samples by different products. add a notice for the products which have more than one FCT process. upgrad

4、e the table(AT-0801-E105-F11) from to .Emmitt Lee511/28/2008A326,2739 add the item . The fabrication of Golden Sample add the GRR reportEmmitt Lee604/10/2009A426, 27, 381. Modify the occasion of Golden Sample for section .2. Modify the description of fabrication of Golden Sample for section .3. Modi

5、fy the Board Assembly Manufacturing Golden Sample Label (AT-0801-E105-F11)Eden Chu712A53826 the Board Assembly Manufacturing Golden Sample Label (AT-0801-E105-F11) more explanations to for Golden Sample之製作Jackshen811A630,314049New Golden sample Label approved must achievement with in 24 hours.To pre

6、vent Golden sample escape to customer site, need lock PCBAs serial number form SFIS.PDsupervisor need Lock PCBAs serial number after Receiving and signing for Golden sample.Management Procedure of Board Assembly Manufacturing Test Golden Sample For VPD Products (AUO,CMI).Jeff TsengAG-0801-M006-F3 Re

7、v.:A1目 錄Table of Content目的 Purpose適用範圍及時機Scope and Occasion零件產品Golden Sample管理辦法 (Chinese). 適用範圍及時機 . 作業流程圖 . 作業輸入/項目. 作業規定要點. 作業輸出 . 相關文件與表單3. Control of Component parts Golden Sample (English). Scope and Occasion. Operation Flow. Operation input / item, key criteria, output. Related doc. And sheet

8、4. Management Procedure of Board Assembly Manufacturing Test Golden Sample. 使用範圍及時機 Scop and Occasion. Golden Sample之製作: The fabrication of Golden Sample. 測試治具及程式開發製作階段Golden Sample使用及管理流程圖及說明 The flow chart and descriotion of Golden Sample usage and management in the stage of test fixture developme

9、nt and fabrication. 量產階段Golden Sample使用及管理流程圖及說明 The flow chart and descriotion of Golden Sample usage and management in the mass production stage. 工程變更(EC)變更時Golden Sample使用及管理流程圖及說明The flow chart and descriotion of Golden Sample usage and management when the product has an EC. Golden Sample的使用期限與定

10、期驗證或更新流程圖及說明The flow chart and description of Golden Sample verification and replacement. 注意事項 Notice. 相關文件與表單Related doc. And sheet目的: PurposeUSI於產品製造及測試過程中,協助判斷製程或是測試時品質的參考產品樣本。 A golden Samle is the reference unit for the quality of the testing and manufacturing process In USI.適用範圍及時機Scope and Oc

11、casion凡產品進入量產階段或是sample階段時經開發工程和品保部門依實際需要,認為需有Golden Sample 做為協助製程或是測試時,產品品質判定的參考時,Golden Sample 的管理要求皆需依此辦法。 This procedure is applied for component parts, if Golden Sample is necessary, in the manufacture process to assist judgment as a reference for product quality, confirmed by R&D and QA depart

12、ment. Then the control of Golden sample should be follwed this procedure.3.零件產品Golden Sample管理辦法 (Chinese): . 適用範圍及時機: 適用於零件產品,凡經由開發工程和品保部門依實際需要,認為需有Golden Sample 做為協助製程或是測試時,產品品質判定的參考時,其Golden Sample 的管理要求皆需依此辦法。 . 作業流程圖 Dept.StepR&D Cal. UnitPDQEControl PointDocument樣品 建立 需求 判定1.經RD/QA認為需有Golden S

13、ample之產品1.經RD/QA認為需有Golden Sample之產品, RD在產品 規範中訂定產品規範2建立 樣品2.依Golden Sample 2.依Golden Sample 作業需求予以建立產品規範 3.校驗 與記 錄3.3.校驗 Golden Sample產品規範4.登錄 與建 檔、 標示4.4.建檔與 貼標籤校驗記錄與標籤&D 取回5. 5. 儀校室通知 RD取回樣品6.交給PD6.6.樣品轉交 PD使用 使用樣品不良樣品不良異常異常 7. 7.使用情形產品規範8.異常 處理系統設定不良 8.系統設定不良 8.確認問題治具不良治具不良儀器不良儀器不良正常正常8-1.8-1.問題

14、排 除與確 認8-2.8-2.儀器維 修與校 驗正常9.儀校室發 聯絡單正常9.儀校室發 聯絡單9.回校 通知異常 10.異常 10.樣品校驗 校驗 樣品1111.同8.流 程11.異常 處理112記錄與 貼標籤 12.記錄 與 識別記錄標籤. 作業輸入/項目. 作業規定要點. 作業輸出 作業輸入/項目作業規定要點作業輸出 1樣品建立 需求判定R&D/QA依需要性, 決定是否需要有Golden Sample做為該產品生產時,驗證該生產之產品是否符合規格, 或該生產量測系統、test fixture是否為符合要求之測試系統。當認為有需要時,R&D需在產品規範中訂定Golden Sample 作業

15、需求及製作樣品。 規範 樣品2建立樣品R&D依產品規範,製作Golden Sample 3校驗與記錄1. R&D做第一次的Golden Sample 校驗。2.完成履歷卡填寫、記錄Data及其他可能資料 (如相片)R&D應告知QE 校驗時間, 以便QE一同參與, 有助以後 QE 的校驗. 履歷卡 校驗記錄 4登錄與建 檔、標示R&D將Golden Sample、履歷卡及校驗Data或/和相片拿至儀校室登錄、建檔。2.儀校將資料建檔後,並在Golden Sample 貼上校驗標籤。 履歷卡 校驗記錄 標籤 5. R&D取回R&D取回 Golden Sample 或/和相片。 R&D取回Golde

16、n Sample 6. 交給PDRD轉交Golden Sample 或/和相片給予PD.。PD需在整潔、一般的作業環境 (255C ; 4575%RH)下小心使用與保存Golden Sample PD取用Golden Sample及保存 7. PD使用PD產品規範使用Golden Sample 。如果發現異常,需通知R&D確認是Golden Sample問題 或是量測系統本身問題。 8. 異常處理R&D檢測是Golden Sample問題或量測系統本身問題。如是量測系統設定或量具不良,R&D需修復它。如是Golden Sample問題,儀校人員需加貼”暫停使用”標籤以為識別,R&D則需重新製作

17、建立新Golden Sample。4.如是儀器問題,則送儀校室校驗及依”儀具校驗與維護管制 程序”處理 9. 回校通知 與校正1.儀校室發行聯絡單通知負責Golden Sample 例行校正之 QE及PD,以進行Golden Sample 校驗之作業。儀校室得協調PD,排定Golden Sample 校驗時間,並將日期通知QE。如果該Golden Sample 之產品已滿一年(含)以上未生產,則該Golden Sample 得轉存儀校室,並貼上”暫停使用”標籤。轉存儀校室之Golden Sample 第一年仍需校驗,第二、三年如有使用,則依正常校驗週期校驗,如未使用則不必校驗。若該轉存儀校室之

18、Golden Sample,轉存超過三年仍在”暫停使用”狀態,則儀校室得通知R&D決定該Golden Sample 報廢與否,或其他處理方式 (如不報廢,則該Golden Sample轉R&D保存)。有關產品是否已一年未生產,需QA/R&D 提供訊息給QE或/和儀校室,以便停校之處理。 聯絡單 10. QE校驗樣 品QE於第一次校驗各類Golden Sample時,R&D相關人員得陪同,以確認測試的正確。如果校驗結果為Pass,QE需將Golden Sample與Data交儀校室登錄歸檔及貼上標籤。3. 如果校驗結果為Fail,則依異常處理方式執行。校驗Data 11 異常處理如果校正結果顯示

19、不能符合規格需求,則需會同RD一起確認問題原因。如是量測系統設定或量具不良,R&D需修復它。如是Golden Sample問題,R&D需重新製作建立新Golden Sample。如是儀器問題,則送儀校室校驗及依”儀具校驗與維護管制程序”處理。 12 記錄與識 別QE將Golden Sample 測試Data或/和相片拿至儀校室,由儀校室登錄歸檔及貼上標籤別識。儀校室通知PD取回Golden Sample或/和相片 校驗記錄 標籤:1.大陸廠環旭的Golden Sample回校單位由環旭儀校室負責。2. 280 PWR產品Golden Sample的校驗, 依據客戶Golden Sample首件

20、檢查管制系統. . 相關文件與表單Golden Sample 校驗聯絡單 AT-0801-E105-F1零件產品Golden Sample 列管產品明細表 AT-0801-E105-F2零件產品Golden Sample 列管履歷卡 AT-0801-E105-F3零件產品Golden Sample 校驗記錄 AT-0801-E105-F4標籤 AT-0801-E105-F5 年 月份 處 部 課Golden SampleGolden Sample校驗聯絡單AT-0801-E105AT-0801-E105-F1 Rev: A11. 保存年限1年.2. 請將此聯絡單第一聯於QE留存, 以利QE依有

21、效日期執行校驗. 聯絡單第二聯於QE完成校驗後送儀校室歸檔. 聯絡單第三聯於FQC留存, 以防止Golden Sample超過有效日期 . 聯絡單第三聯於PD留存, 請PD針對到期之Golden Sample準備校驗.3. 有效日期如與實際使用衝突, 請PD來電或註明於此通知單上.零件產品零件產品Golden Sample 列管產品明細表所屬單位:產品編號:校驗人員:列管產品所含Golden Sample 之項目樣品別管制編號建立時間備註備註:AT-0801-E105-F2 Rev: A11. 保存年限1年。1. 保存年限1年。2. 說明: 生產單位於領用Golden Sample 後需將列管

22、履歷卡及校驗表依編號裝訂成冊, 並佐以明細表。 零件產品零件產品Golden Sample 列管履歷卡所屬單位:產品編號:管制編號:保存環境:校驗人員:建立時間:樣品編號: 校驗時間校驗項目校驗結果 ( PASS / FAIL )備註:AT-0801-E105-F3 Rev: A1保存期限保存期限: 至產品不生產後1年說明: (1)校驗Golden Sample 需使用校驗合格之儀具. (2)校驗編號由儀校室給予 (3)校驗規格需清楚填註tolerance (4)保存方式需考慮到包含保存地點, 溫濕度及如何保存 (5)校驗項目/規格如無法以上述表格描述, 得附件說明零件產品零件產品Golden

23、 Sample 校驗記錄所屬單位:產品編號:管制編號:校驗時間:校驗人員:下次校驗時間:樣品編號:校驗項目校驗步驟校驗規格校驗實得數據校驗結果(ACC/REJ)備註:AT-0801-E105-F4 Rev: A11. 1. 保存期限: 3年2. 說明: (1)校驗Golden Sample 需使用校驗合格之儀具。 (2)校驗規格需清楚填註tolerance。暫暫 停 使 用 損 壞 待 校 其 它確認人 / 日期GOLDEN SAMPLED/D:GOLDEN SAMPLED/D:USER:CHECK:P/N:標 籤 (良品 - 藍色標籤)GOLDEN SAMPLEGOLDEN SAMPLED/

24、D:USER:CHECK:P/N: (不良品 - 紅色標籤)AT-0801-E105-F5 Rev: A13. Control of Component parts Golden Sample(English):. Scope and OccasionThis procedure is applied for component parts, if Golden Sample is necessary, in the manufacture process to assist judgment as a reference for product quality, confirmed by R

25、&D and QA department. Then the control of Golden sample should be follwed this procedure. Operation Flow Dept.StepRD Cal. UnitPDQEControl PointDocument request1. R1. R&D/QA Confirm Golden Sample request and Spec. defined by R&DProduct Spec. set up up Golden Sample up Golden Sample Product Spec. and

26、Record3.3. Golden Sample being calibrated4. Filing &4. Filing & Stick LabelProduct Spec.4. Register,Filing , marking5. Cal. Room inform R&D 5. Cal. Room inform R&D to get back sampleCal. Record and Label get back66 .Sample deliver to PD for using. PD使用 over to PDSample failSample failNonconformingNo

27、nconforming 7 7.usedusedProduct Spec.8.Dispose ofNoncon-formingParameter fail 8Parameter fail 8.Problem ConfirmEquip. failEquip. failGoodGoodTooling fail & confirmedTooling fail & confirmed and calibrated and calibrated. Recall9. Release Cal.9. Release Cal. notice10Sample cal. by QEGoodGood 10. 10.S

28、ample11.DisposeofNoncon-forming Fail process as item 8 Fail process as item 8 12Record & idendi-fication112 Record & stick labelRecordLabel. Operation input / item, key criteria, output Operation input / itemOperation key criteriaOperation output1 Judge request of golden sampleQA depend on the requi

29、rements to judge if it is necessary to make Golden Samples to qualify product quality, measuring system, or test fixture is matched to its criteria。2. If it is needed to set up Golden Sample, R&D will define this Golden Sample operation process on the product specification and make Golden Sample. Sp

30、ecification Sample2 Set up Golden SampleRD depends on product specification to make Golden Samples 3 Cal. & record1. RD takes the first Golden Sample calibration。2. Complete Curriculum vitae, record data and other possible information (such as photo)3. RD informs QE to join the calibration to helpfu

31、l QE cal. in later. Curriculum vitae Cal. Record 4. Register, filing, marking takes Golden Sample、vitae and cal. data or/and photo to Cal. Room for register, filing, marking.2. After filing data, Cal. Room stick the cal. label on the Golden Sample Curriculum vitae Cal. RecordLabel5. RD take back1. R

32、D takes back Golden Sample or/and photo RD takes back Golden Sample6. Deliver to PD1. RD delivers Golden Sample or/and photo to PD.2. PD should be careful to use and preserve Golden Sample under cleaning and operation ambient is 255C ; 4575%RH PD takes and preserves Golden Samples7. PD utilizing1. P

33、D utilize Golden Samples product specification accordingly2. if nonconforming happened, PD Inform R&D to find out the problem is Golden Sample or measuring system. 8. Dispose of nonconforming1. RD checks problem happen in Golden Sample or measuring system.2. If measuring system or tooling fail,R&D s

34、hould recover it.3. If it is Golden Sample problem, Cal. Room shall identify it by stick ”stopped usage” label on it. R&D needs to re-make new samples.4. If it is instrument problem, checked by Cal. Room and handled it “Instrument calibration and maintenance procedure” accordingly.9. Recall and cali

35、bration1. Cal. Room release recall sheet to owner, QE and PD, to do the Golden Sample calibration by regularly 2. Cal. Room coordinates PD to arrange cal. time and inform QE.If product has stopped production more than one year, the Golden Sample will be delivered to Cal. Room to be stuck “stopped us

36、age” label and stored. The fist year after delivered shall be calibrated, and it cant be calibrated if not being used in 2nd, 3rd year. If Golden Sample stored Cal. Room has been over 3 years on “stopped usage” status, Cal. Room inform R&D to scrap it or to dispose of any other ways (If not be scrap

37、ped, deliver to R&D stored)4. QA/R&D shall inform message to QE or/and Cal. Room to stop calibration of Golden Sample for product has one year not been manufactured. Recall sheet 10. QE cal. Sample 1. R&D people should accompany QE to do Golden Sample of each type to ensure its accuracy for the firs

38、t calibration. 2. If cal. result is Pass,QE shall pass Golden Sample and data to Cal. Room for register, filing and sticking label.3. If cal. result is fail,Nonconforming process is accordingly.Cal. Data11 Dispose of nonconforming 1. If cal. result shows it cant comply with the criteria, it should b

39、e confirmed the reason jointly with R&D. 2. If it is settled problem of measuring system or failed to measuring tooling, R&D should recover it.3. If it is Golden Sample problem, RD should remake a new Golden Sample.4. If it is instrument problem, send it to Cal. Room for calibration and “instrument

40、calibration and maintenance procedure” is followed. 12 Record and identification1. QE will deliver the Golden Sample, test data or/and photo to Cal. Room to be Registered, filed and identified by label.2. Cal. Room informs PD to take back Golden Sample or/and photo. Cal. Record Label:1. For SZ plant

41、, Cal. Room is in charge of the job of Golden Sample recall calibration.2. For 280 power products, Golden Sample follows customers first article checking control system. . Related doc. And sheetGolden Sample Recall Sheet AT-0801-E105-F6Control list of component parts Golden Sample AT-0801-E105-F7Cur

42、riculum vitae of component parts Golden Sample AT-0801-E105-F8Calibration record of component parts Golden Sample AT-0801-E105-F9Label AT-0801-E105-F10Golden SampleGolden Sample recall sheetThe first copy for the user unitThe first copy for the user unitAT-0801-E105-F6 AT-0801-E105-F6 Rev: A11. To b

43、e reserved for 1 years.2. Please reserve the page 1 of this recall sheet for QE department, in favor of QE to track the controlled due 2 of Recall sheet, to keep on the file at Calibration Room after QE finished the 3 of this recall sheet, preserve on the FQC, to prevent the Golden Sample over the c

44、ontrolled due 4 of recall sheet, preserve on the PD, PD prepare the Golden Sample calibration before expire date. 3. Any conflict between Control due date and actual application, feedback to Calibr. Room or remark on this recall list.Control list of component parts Golden SampleControl list of compo

45、nent parts Golden Sample USER :Product no.:Performed by: Product of itemsample listcontrol no.set up timeremarkremark:AT-0801-E105-F7 Rev: A1 1.1. To be reserved for 1 years.2. Illustration: After received the Golden Sample, need to wrap the equipment curriculum vitae and calibration list with a boo

46、k, and attached the classification list.Curriculum vitae of component parts Golden Sample Curriculum vitae of component parts Golden Sample user:product no.:control no.:preserve environment:performed by:set up time:Sample no.: Set up timeItem Result ( PASS / FAIL )remark:AT-0801-E105-F8 Rev: A11. Re

47、servation Deadline: Wait one year after product halted or stopped to run.1. Reservation Deadline: Wait one year after product halted or stopped to run.2. Illustration: (1). Need to use calibrated equipment to calibrate the Golden Sample.(2). Calibration series number provide by Calibration Room.(3).

48、 Calibration criteria need to write the tolerance obviously.(4). Reservation method need to consider the reservation place, reservation temp./humidity and reservation handling procedure(5). Any Calibration item/criteria avoid above list, need to illustrate with the other attachment.Calibration recor

49、d of component parts Golden Sample Calibration record of component parts Golden Sample user:product no.:control no.:set up time:performed by:last set up time:Sample no.:ItemStepsToleranceDataResult(ACC/REJ)Remark:AT-0801-E105-F9 Rev: A11. To be reserved for 3 years.1. To be reserved for 3 years.2. I

50、llustration:Need to use calibrated equipment to calibrate the Golden Sample.Calibration criteria need to write the tolerance obviously.LabelLabelGOLDEN SAMPLED/D:GOLDEN SAMPLED/D:USER:CHECK:P/N:Stopped usage Damage Waiting OthersVerifier/date (PASS - Blue Label) GOLDEN SAMPLEGOLDEN SAMPLED/D:USER:CH

51、ECK:P/N: (BAD - Red Label)AT-0801-E105-F10 Rev: A14. Management Procedure of Board Assembly Manufacturing Test Golden Sample:. 使用範圍及時機:Scop and Occasion: 範圍:本管理程序適用於Board Assembly Manufacturing Test。Board Assembly Manufacturing Test Golden Sample是一個用來開發、製作和驗證測試程式及治具的產品樣本。其型態可分為兩種:PASS Golden Sample

52、and Fault Golden Sample.The management procedure is applied to Board Assembly Manufacturing Test. Board Assembly Manufacturing Test Golden Sample is a sample of product used to develop, fabricate and certify the test program and fixture. There are two types: PASS Golden Sample and Fault Golden Sampl

53、e. 使用時機:EVT、DVT 及 MVT 等樣品製作階段,Goldden Sample視各測試站的需求,由 PE 提供Golden Sample,以利 TE 開發、製作與驗證測試程式和治具。量產階段,Golden Sample為各測試站之必備工具,以利 PD 定期地驗證測試程式與治具。 Occasion:In the EVT, DVT and MVT sample build phases, Golden Samples are provided by PE or PjM according to the requirement of each test station so that TE

54、 can develop, fabricate and verify the test programs and fixtures.In the MP phase, Golden Sample is a necessary tool for each test station so that PD can verify the test programs and fixtures regularly. . Golden Sample之製作: The fabrication of Golden Sample EVT、 DVT 及 MVT階段,因產品仍未開發完成,需經由 PE 提供設計者驗證過的

55、Golden Sample。Golden Sample須附上 PE 簽核的Board Assembly Manufacturing Golden Sample標籤 (AT-0801-E105-F11)。 量產階段之 Golden sample 可延續 NPI phase 保留之 Golden sample 繼續使用 , 若因故而必須重新製作 Golden sample時 , 應由生產線提供產品由 TE 或 TD 根據PE 提供的產品規格書,依照下列方法製作,並附上 TE, PE, QA 簽核的Board Assembly Manufacturing Golden Sample標籤 (AT-08

56、01-E105-F11)。如產品生命周期將結束(EOL)造成爭議,則由 TE召集相關單位(PD, PE, BD)共同討論解決之. 該產品之所有測試項目皆為邏輯性判斷項目(如MOB, POS.etc),由 TE 挑選現行生產版本之產品,實際安裝測試時所需之所有週邊,並經由 GR&R之驗證程序後,如果GRR值 10%,則該挑選之產品得視為 Golden Sample。該GR&R驗證結果應填寫於表格(AT-0801-E105-F12),並隨附於該產品之Golden Sample標籤以為證明。. 該產品之測試項目有一個(含)測試項目以上有量測值方可判斷Pass或是Fail:.1. 該量測項目可以不透過

57、治具而直接由儀器實際量測:由 TE 挑選現行生產版本之產品,依照產品規格書之需求安裝所需之週邊,以校驗期限內合格之儀器 (電表、示波器、分析儀etc) 量測該產品,所有量測項目及量測值均符合產品規格書所定義之規格,可視為Golden Sample。該量測值並需記錄於表AT-0801-E105-F11中以為驗證之標準。.2 該量測項目必須透過治具量測:治具製作 (DVT 或 MVT 階段) 是以 PE 提供設計者驗證過的 Golden Sample 為標準。故透過治具的實際量測值 (A) 減掉產品規格書定義的值 (B),即為治具的補償值 (C=A-B)。量產階段,由 TE 挑選現行生產版本之產品

58、,依照產品規格書之需求安裝所需之週邊,以治具實際量測值 (A) 減掉治具補償值 (C) 後,若所得到的值 (B=A-C) 符合產品規格書所定義之規格 (B=B),可視為Golden Sample。 PE must provide the Golden Sample verified by designer in the EVT, DVT and MVT phases because the product is not completed. The Golden Samples must attach the label Board Assembly Manufacturing Golden

59、Sample (AT-0801-E105-F11) signed by PE. Golden Sample that reservation from NPI phase can be kept using in MP phase. If failures that the Golden Sample has to be rebuilt, PD should provide the sample product for TE(TD). TE(TD) follows the rules below to fabricate the Golden Sample based on the produ

60、ct specification provided by PE. The Golden Samples must attach the label Board Assembly Manufacturing Golden Sample (AT-0801-E105-F11) signed by TE, PE and QA. If some issues due to a product will end of life (EOL), TE convene relevant units(PD,PE,BD) to discuss the solution. . If all the test item

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论