1、HIMOD模块化机房专用空调(风冷)技术参数下送风型号 20U24U28U34U40U26U32U42U46U55U65U81U制冷系统 单单单单单双双双双双双双风量m/h58006600998011040125109980110401251013500145601568020450最大风压Pa450400430400370430400370320100100200风机输入功率KW1.01.32.22.42.72.22.42.73.03.74.15.6总冷量KW20.125.330.535.444.329.035.542.553.758.766.684.1显冷量KW19.324.129.934
2、.742.929.034.141.751.654.260.676.5噪音DB(A)51.354.656.557.659.256.557.659.060.862.663.863压缩机输入功率KW4.35.86.27.18.95.87.28.711.716.218.318.0显热比SHR 0.960.950.980.980.971.000.960.980.960.920.910.91能效比EER 3.813.533.633.733.813.623.713.743.663.233.343.28上送风型号 20O24 O28 O34 O40 O26 O32 O42 O46 O55 O65 O 制冷系统
3、 单单单单单双双双双双双 风量m/h57806690982010790124709820107901247013200 最大风压Pa450380430370330430370330280 风机输入功率KW1.11.42.42.93.22.42.93.23.5 总冷量KW19.925.030.435.143.529.135.041.752.7 显冷量KW19.123.329.534.442.628.233.641.752.7 噪音DB(A)52.555.957.860.061.857.860.060.861.9 压缩机输入功率KW4.35.86.27.18.95.87.28.711.6 显热比S
4、HR 0.960.930.970.980.980.970.961.000.96 能效比EER 3.643.493.543.503.643.543.473.513.49 加湿器最大加湿量Kg/h9.89.89.89.89.89.89.89.89.89.89.89.8额定功率KW7.37.37.37.37.37.37.37.37.37.37.37.3电加热器额定功率KW5.855.8511.711.711.711.711.711.711.711.711.711.7室内风机离心式可调速数量n112222222222电机额定功率KW2.52.52.52.52.52.52.52.52.53.74.24.
5、2压缩机涡旋式数量n111112222222蒸发器数量n111111111111管材翼片材质 铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝铜/铝迎风面积074074149149149149149149149149149149过滤器高效等级 G4G4G4G4G4G4G4G4G4G4G4G4外形尺(LWH)mm1000890195017501890195025508901950重量KG380385580585590580585590605630630940HIMOD模块化机房专用空调(水冷)技术参数下送风 20U24U28U34U40U26U32U42U46U55U65U制冷
6、系统 单单单单单双双双双双双风量m/h580066009980110401251099801104012510135001456015680最大风压Pa450400420400370430400370320100100风机输入功率kW1.01.32.22.42.72.22.42.73.03.74.1噪音dB(A)51.354.656.557.659.256.557.659.060.862.864.8冷凝器入口水温为15冷凝温度为40总冷量kW20.927.331.636.645.830.036.543.755.558.766.6显冷量kW19.726.230.035.243.529.134.3
7、42.053.354.061.3压缩机输入功率kW3.95.35.56.37.95.26.57.810.612.613.9显热比SHR 0.960.950.950.960.950.970.940.960.960.920.92能效比EER 4.274.004.114.224.324.064.124.214.113.633.68水流量1/h9001152133215481908612756900118844944976水端压降kPa2+33+42+12+22+31+11+10+11+13+43+4冷凝器入口水温为30冷凝温度为45总冷量kW20.125.230.535.444.329.135.04
8、2.553.757.264.5显冷量kW19.324.029.934.742.929.133.941.751.654.359.3压缩机输入功率kW4.25.86.27.18.95.87.28.711.713.915.4显热比SHR 0.960.950.980.980.971.000.970.980.960.950.92能效比EER 3.883.643.643.743.823.643.663.733.653.253.30水流量1/h1692280828443096410424123240360057961292014306水端压降kPa6+918+2511+68+810+1310+1217+22
9、7+1019+2732+3339+41上送风 20O 24O28O34O40O26O32O42O46O 制冷系统 单单单单单双双双双 风量m/h57856690982010790124709820107901247013200 最大风压Pa450380430370330430370330280 风机输入功率kW1.11.42.42.93.22.42.93.23.5 噪音dB(A)52.555.957.860.061.857.860.060.861.9 冷凝器入口水温为15冷凝温度为40总冷量kW20.626.231.336.345.429.936.143.354.4 显冷量kW19.325.0
10、29.834.843.229.034.042.052.2 压缩机输入功率kW3.95.35.56.37.95.26.57.810.6 显热比SHR 0.940.920.950.960.950.970.940.970.96 能效比EER 4.123.954.013.964.093.953.853.943.86 水流量1/h86411161332151219086127569001152 水端压降kPa2+23+42+12+22+31+11+10+11+1 冷凝器入口水温为30冷凝温度为45总冷量kW19.925.230.435.144.128.735.041.752.7 显冷量kW19.123.729.534.442.828.733.641.750.6 压缩机输入功率kW4.35.86.27.28.95.87.28.711.6 显热比SHR 0.960.940.970.980.971.000.961.000.96 能效比EER 3.643.483.543.493.643.493.483.503.49 水流量1
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 关于空调合同标准文本
- 主机备件采购合同标准文本
- 入股汽修店合同样本
- 会展合同标准文本分析
- 业务鉴定合同样本
- 企业股东合作合同标准文本
- 供货合同与买卖合同样本
- 买卖个人房产合同范例
- ppp医院合作合同样本
- 2025前期物业管理合同(版)《物业管理合同》
- GB/T 22163-2008腧穴定位图
- GB/T 12603-2005金属热处理工艺分类及代号
- 船舶发展史课件
- 2022统计执法资格考试题库(含答案)
- 天然药物研究的回顾与展望课件
- 通信线路工程施工技术规范(新)
- Unit15-The-necklace-reading-公开课一等奖课件-高中英语
- 《贝叶斯统计》课程教学大纲
- Q∕GDW 10202-2021 国家电网有限公司应急指挥中心建设规范
- 审计实施方案模板格式
- 工程测量报价单
评论
0/150
提交评论