版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、实用标准文档通风排烟设计工具箱通风管道流量阻力表1、缩伸软管摩擦阻力表圆形风管v=2 m/sv=3 m/sv=4 m/sv=5 m/sv=6 m/s150127/0.43190/0.98254/1.8318/3.23381/4.46200226/0.32339/0.73452/1.30565/2.03678/2.92250353/0.26530/0.558707/1.04883/1.621060/2.33300509/0.21764/0.951018/1.621273/2.441521/3.582、镀锌板风管摩擦阻力表矩型风管风量(m3/h)/摩擦阻力(Pa)mmv=2m/sv=3 m/sv=
2、4 m/sv=5 m/sv=6 m/s120 x120104/0.61156/1.27207/2.15259/3.25311/14.57160 x120138/0.51207/1.07277/1.8346/2.75415/3.86160 x160184/0.42277/0.78369/1.49461/2.26553/3.17200 x120173/0.46259/0.95346/1.62432/2.45734/3.44200 x160230/0.36346/0.77461/1.3576/1.79691/2.78250 x120216/0.41324/0.87432/1.47540/2.2364
3、8/250 x160288/0.32432/0.69576/1.17720/1.77864/2.48250 x200360/0.27540/0.58720/0.99900/1.501080/2.11320 x120269/0.38403/0.79537/1.34672/2.03806/2.86320 x160369/0.29553/0.61737/1.04922/1.581106/2.22320 x200461/0.25691/0.519221/0.871152/1.311382/1.85320 x250576/0.21864/0.431152/0.741440/1.121728/1.5740
4、0 x120336/0.35504/0.74673/1.25841/1.901009/2.67400 x160461/0.27691/0.56922/0.951152/1.451382/2.03400 x200576/0.22864/0.461152/0.781440/1.201728/1.68400 x250720/0.191080/0.381440/0.661800/1.002160/1.40500 x160576/ 0.25864/0.521152/0.891440/1.341728/1.89500 x200720/0.211080/0.421440/0.731800/1.12160/1
5、.54文案大全实用标准文档500 x250900/0.171350/0.351800/0.602250/0.902700/1.28500 x3201152/0.141728/0.282304/0.492880/0.753456/1.05500 x4001440/0.122160/0.252880/0.423600/0.644320/0.89630 x160726/0.221089/0.481452/0.841814/1.122177/1.98630 x200907/0.191361/0.391814/0.672268/1.022722/1.43630 x2501134/0.161701/0.3
6、22268/0.552835/0.833402/0.19630 x3201452/0.132177/0.262903/0.443629/0.674355/0.94630 x4001814/0.112722/0.223629/0.374536/0.565443/0.79630 x5002268/0.13402/0.194536/0.315670/0.486804/0.68800 x160922/0.201382/0.421843/0.672304/1.022765/2.15800 x2001152/0.181728/0.372304/0.632880/0.953456/1.34800 x2501
7、440/0.142160/0.32880/0.513600/0.774320/1.08800 x3201843/0.12765/0.233686/0.404608/0.605530/0.851000 x2001440/0.162160/0.352880/0.603600/0.904320/1.301000 x2501800/0.132700/0.283600/0.484500/0.725400/1.021000 x3202304/0.113456/0.234608/0.375760/0.576912/0.80圆形风管v=2 m/sv=3 m/sv=4 m/sv=5 m/sv=6 m/s1005
8、5/0.7683/1.58111/2.68139/4.05166/5.69140109/0.49164/1.03219/1.75273/2.64328/3.72200224/0.31336/0.66448/1.12560/1.69672/2.382503.49/0.24524/0.5698/0.85873/1.281048/1.80360727/0.151090/0.321454/0.541817/0.822180/1.15400898/0.131347/0.281796/0.472245/0.722694/1.015001405/0.12108/0.212811/0.363513/0.554
9、216/0.77说明(1),软管采用荷兰数据时,上述数据乘以下系数:150 x2;200 x1.8 ; 250 x1.5 ; 300 x1.3(2),局部摩擦阻力:散流器喉径(mm) P (Pa)v=2m/sv=3 m/sv=4 m/sv=5 m/sv=6m/s200 x20015.935.763.499.1142.7300 x30023.853.595.1148.7214.1400 x40029.466.0117.3183.2263.9(3)与散流器的摩擦阻力:文案大全实用标准文档接管规格 P (Pa)(mm)v=2m/sv=3 m/sv=4 m/sv=5 m/sv=6m/s镀锌管200 x
10、2002.45.39.414.721.2镀锌管400 x4006.414.3225.539.857.3软管15010.822.328.841.354.1软管35010.122.740.463.190.8(4),保持风速必须的动压:当 v=2m/s时, P=2.4Pa;当 v=3m/s 时, P=5.4Pa当 v=4m/s时, P=9.6Pa;当 v=5m/s 时, P=15Pa当 v=6m/s时, P=21PaV2(5).其他局部阻力的计算按下式2g P二 ( T:、室内送回风口尺寸表1、风口风量冷量对应表冷量风量送风口回风口RTkwm/hmmmm1.03.5750700 x150800 x1
11、501.55.3800700 x150800 x1502.071000900 x1501000 x150/800 x2002.58.714501000 x2001200 x2003.010.516001100 x2001300 x2003.512.218001250 x200/1000 x2501500 x200/1200 x2504.01419501000 x2501300 x2505.017.5830001600 x250/1360 x3002、不同送风方式的风量指标和室内平均流速ASHRAE文案大全实用标准文档送风方式单位地板面积的送风量l/sm 2工作区平均流速m/s换气次数h-1侧送
12、百叶风口3-60.13-0.187条形风口4-100.10-0.1812局部孔板送风5-150.10-0.1818顶棚散流器5-250.10-0.2530顶棚孔板送风5-500.05-0.1560、室内风管风速选择表1、低速风管系统的推荐和最大流速m/s应用场所住宅公共建筑工厂推荐最大推荐最大推荐最大室外空气入口2.54.02.54.52.58.0空气过滤器1.31.51.51.81.81.8加热排管2.32.52.53.03.03.5冷却排管2.32.32.52.53.03.0淋水室2.52.52.52.52.52.5风机出口6.08.59.011.010.014.0主风管4.06.06.0
13、8.09.011.0支风管(水平)3.05.04.06.55.09.0支风管(垂直)2.54.03.56.04.08.02、低速风管系统的最大允许速m/s应用场所以噪声控制 主风管以摩擦阻力控制送风主管回风主管送风支管回风支管住宅公寓、饭店房间3.05.04.03.03.0办公室、图书馆5.07.56.56.05.0大礼堂、戏院6.010.07.58.06.1银行、高级餐厅4.06.55.55.04.0百货店、自助餐7.510.07.58.06.0厅9.012.07.58.06.0工厂12.515.09.011.07.53、通风系统之流速m/s系统商业工业文案大全实用标准文档低送风、最大流速1
14、313送风、一般流速6-1111-13速回风、最大流速1013回风、一般流速7.5-99-13高速、一般1313-25室内允许噪声主管风速支管风速dB (A)m/sm/s25-353-447、百叶窗的推荐流速m/s位置新风回风减温器正面减温器旁通加热器旁通流速m/s2.5-44-62-47.5-125-7.58、逗留区流速与人体感觉的关系文案大全实用标准文档流速m/s人体感觉-0-0.08不舒适,停滞空气的感觉0.127理想,舒适0.127-0.25基本舒适0.38不舒适,可以吹动薄纸0.38对站立者为舒适感之上限0.38-1.52用于工厂和局部空间9、顶棚散流器送风量尺寸mm送风流速m/s1
15、.01.52.02.53.755.0250*250507095120175235300*30070100135170255340350*35090140185230350465400*400120180240295440590500*500190280380470710945600*6002704105456801020136010、侧送风口送风量送风口尺寸mm送风口流速m/s1.52.02.53.755.0250*1003040507095300*10035455585115400*100456075115150500*100557595145190600*10070901151702307
16、50*10085115145215285900*100100135170255340250*150455570105145300*150507085130170400*1507090115170230500*15085115145215285600*150100135170255340750*150130170215320430900*150155205255385515文案大全实用标准文档400*20090120150230305500*200115150190285380600*200135180230340455750*200170230285430570900*200205275340
17、415685400*250115150190285380500*250145190240355475600*250170230285430570750*250215285355535715900*2502553404306408551000*505575951451901000*75851151452152851000*1001151501902853801000*1251451902403554751000*150170230285430570&, lt;, /DIV1000*1752002653305006651000*200230305380570760五、通风系统设计1、送风口布置间距
18、办 公 室2.5-3.5m商场、娱乐114-6m回风口应根据具体情况布置一般原则:(1)人不经常停留的地方;(2)房间的边和角;(3)有利于气流的组织。2、标准型号风盘所接散流器的尺寸表-办公室风盘型号风量方散尺寸FPm3/hmm3.5350200*2005500200*2006.3630250*2508800250*250101000300*300文案大全实用标准文档12.5162025注:办公室推荐送风口流速:2.5-4.0m/s1250160025002500300*300350*350450*450450*450风机盘管接风管的风速:通常为1.52.0m/s之间,不能大于2.5m/s
19、,否则会将冷凝水带出来3、散流器布置散流器平送时,宜按对称布置或者梅花型布置,散流器中心与侧墙的距离不宜小于1000mm圆形或方形散流器布置时,其相应送风范围(面积)的长宽比不宜大于1 : 1.5 ,送风水平射程与垂直射程(平顶至工作区上边界的距离)的比值,宜保持在0.51.5之间。实际上这要看装饰要求而定,如 250*250的散流器,间距一般在 3.5米左右,320*320在4.2米左右。4、空调房间允许最大送风温差C送风方式下列房间高度m23456侧送、大风量6.58.3101214侧送、小风量9.011131517顶棚散流器9.516171818舒适性空调的送风温差 送风高度H小于等于5
20、m,送风温差小于等于 10度;送风高度H大于5m,送风温差小于等于 15度。为防止出风口结露,应使送风干球温度高于室内空气的露点温度2-3度。5、工艺性空气调节空调房间允许最大送风温差室温允许波动范围(oC)送风温差(oC) 1.0=15+ 1.0610+ 2.036+ 1.00.223注:生活区或工作区处于下送气流的扩散区时 ,送风温差应通过计算确定。文案大全实用标准文档、厨房通风问题饮食建筑设计规范(JGJ64-89)对厨房操作间通风彳了明确规定:(1)计算排风量的65%S过排气罩排至室外,而由房间的全面换气排出35% (2)排气罩口吸气速度一般不应小于0.5 m/s,排风管内速度不应小于
21、10 m/s ; (3)热加工间补风量宜为排风量的70溢右,房间负压值不应大于5 Pa。然而,有的工程的厨房未设排气罩,仅在外墙上设几台排气扇;有的虽然设置了排气罩,但罩口吸气速度远小于0.5 m/s ,选配的排风机风量不足。大多工程未设置全面换气装置,亦未考虑补风装置,难以保证室内卫生环境要求及 负压值要求。如何确定厨房的通风量公共建筑中的厨房,是一个很重要的组成部分,但在设计上通常是一个薄弱环节,一方面,在施工图纸设 计阶段,往往得不到有关厨房的详细工艺资料,在建筑专业所提供的方案图上,一般只有厨房的面积、层 高和灶台的位置,另一方面在现有的设计参考资料中缺少有针对性的技术措施,这就给合理
22、地确定厨房通 风量带来了困难,通常同样的厨房,不同的人进行设计,其结果往往不同,甚至相差悬殊,但是依据技术 措施,又能各自找到根据。因此,厨房的通风设计形成了,因人而异,无统一标准的局面,我认为之所以 会出现这种现象,与我们常用的技术措施在厨房通风量确定上,概念不明确,要求不一致有关,为说 明问题,我们可以结合常用的建设部建筑设计院民用建筑暖通空调设计技术措施,(下简称措施一)和我院编制的暖通专业统一技术措施(下简称措施二)中的有关规定,讨论一下厨房的通风量确定问题。措施一第 4-28条规定:机械通风的换气量宜按热平衡计算,计算排风量的65%通过排气罩或屏幕等排除室外,而由房间的全面换气排出3
23、5% 另外,在第4-26条中,已规定了排气罩口的风速应控制在0.40.5m/s o措施二第5- 1-3条中规定:设有空调系统的厨房其机械通风的换气量,宜 按热平衡及风量平衡计算,当热平衡计算确有困难时,可按下述两种方法中的一种计算,并以第一种方法,为优选方法。1. L1=1800 XF1 (F1为罩口面积) L2=10XF2 ( F2为厨房面积)L=L1+L2 ( L为总排气 量)2.按6080次/时换气计算,(厨房面积小于50 m2时取上限,大于50 m2时取下限)。厨房排风中应有相当于35次/时换气次数的风量为全面换气设备排出,但不计入总风量。从措施一措施二的规定中,我们似乎得到一个左右厨房通风量计算的一个概念。那就是,在厨房的排气罩工作时,还应该 有其它的排风机在同时工作,厨房内的排风不能仅从排气罩排出,而必须留有其它排风出路,并且要有一 定的比例关系,或者占到全部排风
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年度城市更新项目门面房买卖及改造合同4篇
- 2025年度私人二手房购房定金合同及房屋装修材料品牌及质量承诺
- 2025年个人二手车辆买卖税费代缴服务合同2篇
- 二零二五年度农场农业生态修复及保护合同3篇
- 2025年度土地入股文化产业合作经营合同范本
- 2025年度环保型木工材料采购与劳务分包合同书4篇
- 2025年度农民工住宿及饮食服务合同
- 2025版木工材料供应链采购与配送合同4篇
- 二零二五年度办公楼智能化装修与系统集成合同2篇
- 二零二五年度土地租赁权居间服务合同样本
- 高中物理斜面模型大全(80个)
- 2025年高考物理复习压轴题:电磁感应综合问题(解析版)
- 012主要研究者(PI)职责药物临床试验机构GCP SOP
- 2024年个人车位租赁合同经典版(二篇)
- 农耕研学活动方案种小麦
- 2024年佛山市劳动合同条例
- 污水管网规划建设方案
- 城镇智慧排水系统技术标准
- 采购管理制度及流程采购管理制度及流程
- 五年级美术下册第9课《写意蔬果》-优秀课件4人教版
- 节能降耗课件
评论
0/150
提交评论