1、1Trouble Shooting Instruction Air ConditionerSumitomo (S.H.I.) Construction MachineryNeo Power PAX Hydraulic Excavator234Control panel for Air-Conditioner buzzed continuouslyThe blow is not coolSee the page “The blower is not COOL”Anti-Overheat Control Device is workingThe speed of blower motor is n
2、ot ChangeableControl panel for Air-Conditioner buzzed continuouslyThe AC blow mode (foot or face) and air mode (open or close) are changeableAnti-Overheat Control Device is workingWhen the speed of blower motor does not work, is the AC mode “Face”?See the page “The speed of Blower Motor is not chang
3、eable”Is the door or window opened?NoYesLimit Control is working by the Door or the front windowLimit control device is working by “COOL MAX” situationPre-Study - 1 -Pre-Study - 2 -5Control panel for Air-Conditioner buzzed continuouslyMagnet Clutch does not workDoes the Magnet Clutch work on all con
4、dition except the air mode “FOOT”?Anti-Overheat Control Device is workingSee the trouble shooting “Magnet Clutch does not work”Blow air is not changeable in fresh or recycleControl panel for Air-Conditioner buzzed continuouslyQuantity of blow can not be adjustedAnti-Overheat Control Device is workin
5、gDoor or the front window is openedLimit Control Device is working by “COOL MAX” situationSee the page ”Blow air is not changeable in fresh or recycle”Pre-Study - 3 -Pre-Study - 4 -6Control panel for Air-Conditioner buzzed continuouslyA/C Mode is not changeableAnti-Overheat Control Device is working
6、The mode “Fresh air” and “recycle air” are changeable each otherSee the page “A/C Mode is not changeable”Pre-Study - 5 -7When auto switch or A/C switch are pushed, “HL.E” is displayed on the panel. “HL.0” through “HL.9” are displayed1) Connector for Air-Mix Motor Actuator is not connected.2) Failure
7、 of Air Mix Motor Actuator.3) Electrical current failure on Harness“SNOW” mark on the panel is flashed Repair or change the parts“SNOW” mark on the panel is flashed 1) Thermocensor in the cab and themocensor on evaporator are short at the same time.2) Failure on Controller1) Thermocensor or harness
8、are cut off or be short2) Connector of thermocensor is not contactedRepair or change the partsWhen “18.0” is set as a standard temperature and blow mode is changed to bent mode, blow is cooler than usual1) Connector of thermosencor on evaporator is not connected or cut off2) Thermocensor on evaporat
9、or are cut off or be shortRepair or change the partsAir Mix Damper is located ate the “COOL MAX”Cool Air is blowing into thermocencorIf Motor actuator does not move, measure the blowing power after checking the reason. Is the blowing power less than 1.5 kgf? Repair the ON/ OFF switch of Clutch of Co
10、mpressorRepair the Power CircuitSee the trouble shooting for freezing cycleController failure and thermosencor failureCheck the duct and remove factors caused cool air enteringRepair1) Check, repair, and exchange the lever on Motor actuator2) Spread the grease over the lever after it is cleaned upMo
11、tor Actuator failure or controller failureThe Blow is not COOLRepairA Y Refer to the MonitorRefer to the MonitorRefer to the “Monitor Mode” section8The Blow is not HOT“HL.0” through “HL.9” are displayed1) Connector for Air-Mix Motor Actuator is not connected.2) Failure of Air Mix Motor Actuator.3) E
12、lectrical current failure on the main harnessRepair or change the partsRepair or change the partsAir Mix Damper is located ate the “HOT MAX”Hot Air is blowing into thermocencorIf Motor actuator does not move, measure the blowing power after checking the reason. Is the blowing power less than 1.5 kgf
13、?Check the hot water lineController failure and thermosencor failureCheck the duct and remove factors caused cool air enteringExchange the Motor Actuator 1) Check, repair, and exchange the lever on Motor actuator2) Spread the grease over the lever after it is cleaned upMotor Actuator failure or cont
14、roller failureWhen auto switch or A/C switch are pushed, “HL.E” is displayed on the panelWhen “32.0” is set as a standard temperature and blow mode is “FOOT”, blow is hotter than usualRepair1) Thermocensor or harness are cut off or be short2) Connector of thermocensor is not contactedRefer to the Mo
15、nitor9Blower Motor dose not workThe amount of blow is “HIGH” and the both terminal(+)(-) are connected to the battery. (See the “Note 1”)Red line of the blower motor (from Main Power) is grounded on the batteryExchange the blower motor1) Check the blower motor relay2) When white / green line and red
16、 line of the blower motor relay are connected to each, the blower motor start to work(See the “Note 2”)Blue / black color harness of the blower amplifier are grounded by about 10 voltage Repair or exchange the controllerBlue / black color line and black line of the blower amplifier are connectedRepa
17、ir or exchange the wire harnessWhite / green color line of the blower motor relay is connected to the groundExchange the blower amplifier after removing the failureRepair or exchange the wire harnessWhen brown / red relay line of the blower amplifier is grounded, the blower motor start to workExchan
18、ge the relayRepair or exchange the wire harnessRepair or exchange the wire harness(Note 1) measure the voltage under every harness connected on (Note 2) For safety, A/C switch, main power switch, and light shall be off when you connect harness directly 10The speed of blower Motor does not changeable
19、“HL.0” through “HL.9” is displayed on the panelExchange the blower amplifier controller Repair or change the parts1) Thermocensor or harness are cut off or be short2) Connector of thermocensor is not contactedRefer to the Monitor11Magnet Clutch does not workWhen “AUTO” switch or “A/C” switch is on,
20、“SNOW” lamp is onThe “Snow” panel is flashed and “E” is displayed on the panelCheck the clutch fuseThe Clutch is connected with voltageHarness is connected with pressure switchExchange the compressor (Clutch failure)AC harness connector (white / red) connected to wheel is grounded to black lineFailu
21、re of pressure switch or error of refrigerant pressureA/C harness have some trouble Exchange harnessExchange controlASee the trouble shooting page “freeze cycle”12Blow air is not changeable in fresh or recycleThe indication for fresh/recycle on the control panel is flashed1) Contamination is attache
22、d to the lever of Motor actuator2) The lever of Motor actuator is broken 1) Motor Actuator connector for fresh/recycle air control is failed or not jointed2) Failure of Motor actuator3) Failure of main harnessExchange the motor actuator1) Remove the contamination2) Exchange the parts13A/C mode is no
23、t changeableThe indication of A/C mode (Human style) on the control panel is flashedThe rod of motor actuator is not released 1) Motor Actuator connector for fresh/recycle air control is failed or not jointed2) Failure of Motor actuator3) Failure of main harnessRepairAll of damper is not slippedChec
24、k or exchangeRepairAfter removing the rod, can move cam heavily (2 kgf over).Motor actuator failure or control failure1) Contamination attached on the Cum or damper2) failure of Cum or damper3) Movement failure caused by contaminationRepair1) remove the contamination2) exchange the parts3) spread th
25、e grease after washing Cum14Air conditioner does not work wellHighest pressure is not high and lowest pressure is not lowIf Compressor switch is off, the high pressure goes to the same pressure as the low pressure Failure of CompressorExchange CompressorHigh and low pressure changed at regular inter
26、vals. (When pressure is not changed, their level are normal)AC blow are not kept coolIt caused water entering to the cooler circuit Exchange the receiver dryer and add refrigerant after remove the waterTrouble Shooting for coolant circuit (1)Phenomenon and result of diagnosis Estimated reasonHow to
27、repair15Air conditioner does not work wellBoth high and low pressure are lower than usualAir balls are found on the Sight GlassOil spread into the pipe or parts (Leak Tester reacts)Gus is leaking from the combined parts with pipesBoth high and low pressure are higher than usualGo to the next page “A
28、1”Gus is leaking from hose alone caused by not adding refrigerant for a longtimeTrouble Shooting for coolant circuit (2)Phenomenon and result of diagnosis Estimated reasonHow to repairOil does not spread into the pipe or parts (Leak Tester does not reacts)Refrigerant is shortFill up refrigerant to t
29、he appropriate levelExchange the combined parts or pipesThe pipe of low pressure is not coolThe blow volume e small when A/C is working long timeGo to section “A3” on page 16Go to section “A2” on page 1516Too much of refrigerant Piping is mixed with air“A1”Failure of expansion valveTrouble Shooting
30、for coolant circuit (3)Phenomenon and result of diagnosis Estimated reasonHow to repairFailure of expansion valve (valve is not connected to thermostat pipe)Exchange the receiver dryer and add refrigerant after remove the waterRepair the thermostat pipe so that it can be connected to the valveKeep t
31、he refrigerant correct amountThe pipe of low pressure is not coolAir balls do not occur even if water is installed on the condenser (the receiver drier is still cool) When water is installed on the condenser, condenser es cooler (both low and high pressure go to the normal level)The pipe of low pressure is cool and a lot of water or frost is attached to the pipeAdjust the cork of valve or repair the valveGo to “A4” on page 1717Repair the expansion valve“A2”Trou
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年中国回形针盒市场调查研究报告
- DB3301T 1149-2024地理标志产品 临安山核桃
- 合同工程量减少补充协议
- 工地钢梯私人合同协议
- 废气处理合同协议书模板
- 设备进驻合同协议
- 小型农机买卖合同协议
- 小区小车位租赁合同协议
- 铁路监护合同协议
- 土方垃圾合同协议
- 2025至2030年中国煤气渣数据监测研究报告
- 小学STEM教育中的创新实验室建设
- 月嫂资格证考试单选题100道及答案
- 川剧 身段知到智慧树章节测试课后答案2024年秋四川艺术职业学院
- 【公开课】跨学科实践:制作简易杆秤(课件)-人教版八年级物理下册
- 2025年保密知识试题库附参考答案(精练)
- 2024年12月7日浙江省机关单位遴选笔试真题及解析(A卷)
- 2024年公司政工专业技术工作总结范例(3篇)
- 石油石化硫化氢培训
- 新生儿贫血的护理查房
- CQI-9 第四版 热处理系统审核表中文完整版-
评论
0/150
提交评论