1、比泽尔机组机组型号压缩机制冷量接管规格外形尺寸()安装尺寸()型号功率KWW回气管液管ABCab2DC-2.22DC2.22.31394522129308207107307752CC-3.22CC-3.22.68492522129308207107307754FC-3.24FC-3.23.1548522129308507107308054EC-4.24EC-4.23.8685528129308507107308054DC-5.24DC-5.24.51805528129308759107308304VCS-6.24VCS-6.25.43510620281611509259109008804TCS
2、-8.24TCS-8.26.66130153516115092510109008804PCS-10.24PCS-10.27.69150953516152092591011008804NCS-12.28.9651765535221520925101011008804H-15.24H-15.211.81522775422215201000101011009554G-20.24G-20.213.975263255422162010551010120010106J-22.26J-22.215.30529500542216201055111012001010说明:1、制冷量工况:-20/50。2、冷凝器
3、风扇电机为6极电机。 &
4、#160; “比泽尔”低噪音风冷冷凝机组(中高温) 机组型号压缩机制冷量接管规格外形尺寸()安装尺寸()型号功率KWW回气管液管ABCab2GC-2.22GC2.21.75429516109307907107307452FC-3.22FC-3.22.2520516109307907107307452EC-3.22EC-3.22.486
5、16522129308207107307752DC-3.22DC-3.22.84738022129308207107307752CC-4.22CC-4.23.49912022129308508107308054FC-5.24FC-5.23.891043522129308759107308304EC-6.24EC-6.24.841285528129308759107308304DC-7.24DC-7.25.7715655281693087510107308304VCS-10.27.022072028161520925101011008804TCS-12.24TCS-12.28.612497535
6、161520925101011008804PCS-15.24PCS-15.29.92982542221620965101012009204NCS-20.211.97345754222162096511101200920说明:1、制冷量工况:-5/50。2、冷凝器风扇电机为6极电机。
7、160; “比泽尔”风冷冷凝机组(中低温)机组型号压缩机制冷量接管规格外形尺寸()安装尺寸()型号功率KW
8、W回气管液管ABCab2HC1.22HC-1.21.37188016106506005205643502FC2.22FC-2.21.85270016106506005205643502EC2.22EC-2.22.22315022106806205706403802DC2.22DC-2.22.64352022129606804709203802CC3.22CC-3.23.03445022129606805209203804FC3.24FC-3.23.649602212106068062010203804EC4.24EC-4.24.3761602212130075067012604104DC5.2
9、4DC-5.25.072802812130075077012604104CC6.24CC-6.26.283902812130075087012604104TCS8.24TCS-8.27.38118803516130084510109008004PCS10.24PCS-10.28.67138003516130084512109008004NCS12.24NCS.12210161503516130090014609008554H15.24H-15.213.921100422213501100141095010554G20.24G-20.216.424450542213501100141095010
10、556J22.26J-22.217.22735054221750950131013509056H25.26H-25.220.731700542210509507508009056G30.26G-30.224.33670054221000110075080010556F40.26F-40.229.644100542810001100800800105544H30.244H-30.226.942250542815009201300100088044G40.244G-40.23148900762815009201300100088066J44.266J-44.237.9547007628167092
11、01290100088066H50.266H-50.247.763400763516709201290100088066G60.266G-60.24973400763516709201290100088066F80.266F-80.260.8882007635167092012901000880说明:1制冷量及功率工况为: -20/50。
12、0; 2、采用FNV型冷凝器的均为分体式结构
13、160; &
14、#160; 3、当蒸发温度低于-25时压缩机必须使用CIC系统及附加冷却. “比泽尔”风冷冷凝机组(中高温) 机组型号压缩机制冷量接管规格外形尺寸()安装尺寸()型号功率KWW回气管液管ABCab2HC2.22HC-2.21.94338016106806205706403802GC2.22GC-2
15、.22.23399016106806205706403802FC3.22FC-3.22.7482016106806205706403802EC3.22EC-3.23.34567022129606804709203802DC3.22DC-3.23.88678022129606805209203802CC3.22CC-3.24.9283502212106068072010203804FC5.24FC-5.25.2196402212130075067012604104EC6.24EC-6.26.23118502812130075077012604104DC7.24DC-7.27.7214480281
16、6130075087012604104CC9.24CC-9.27.98175002816130082510109007804VCS10.27.91191902816130084510109008004TCS12.24TCS-12.29.85231503516130084512109008004OCS15.211.2277003522130090014609008554NCS20.214.132150422213501100141095010554J22.24J-22.215.436450422213501100137095010554H25.24H-25.218.142250542210509
17、107508008654G30.24G-30.221.1485005422100010007508009556J33.26J-33.223.35470054281000110075080010556H35.26H-35.226.76340054281000110075080010556G40.26G-40.2317280054281000110075080010556F50.26F-50.237.9863005435 1150110075080011058GC60.28GC-60.247.71063007635155060095010005508FC70.28FC-70.260.5121200
18、76351550600950100055044H50.244H-50.234.684500763515009201130100088044G60.244G-60.242.497000763515009201130100088066J66.266J-66.248.2109400763516709201120100088066H70.266H-70.255126800763516709201120100088066G80.266G-80.261.9145500764216709201120100088066F100.266F-100.275.7172600764216709201120100088
19、0 说明:1、制冷量及功率工况为:-5/50。2、采用FNV型冷凝器的均为分体
20、60;
21、60; “比泽尔”水冷冷凝机组(中低温)机组型号压缩机型号机组功率制冷量水流量接管规格外形尺寸()安装尺寸()KWWM3/h回气管液管ABCab2CC-3.22CC-3.22.5654001.822128303408305102904FC-3.24FC-3.22.966010222169303709406003204EC-4.24EC-4.23.6675502.522169303709456003204DC-5.24DC-5.24.3588303281610803709457103204CC-6.24CC-6.25.22102303.528161080370
22、9457103204TCS-8.24TCS-8.26.42141504.5352212504107758003204PCS-10.24PCS-10.27.42163905.3352212504107758003204NCS-12.24NCS-12.28.66191606352212904708308503904H-15.24H-15.211.22445084228129047011008503904G-20.24G-20.213.12820095428129047011008503906J-22.26J-22.214.531650105428129048010928503906H-25.26H
23、-25.216.836700125428129048010928503906G-30.26G-30.219.6423001454281650600109210005506F-40.26F-40.224.35050016.5543516906001092100055044H-30.244H-30.222.44890017543516709201300100088044G-40.244G-40.226.25640018763521009201300150088066J-44.266J-44.2296330020.3763521009201290150088066H-50.266H-50.233.6
24、7340023.5764221009201290150088066G-60.266G-60.239.28460027764224009501300130068066F-80.266F-80.248.6101100337642240095013001300680 说明:1、制冷量及功率工况为:-20/40。
25、160; 2、当蒸发温度低于-25时压缩机必须使用CIC系统及附加冷却。
26、 “比泽尔”水冷冷凝机组(中高温)机组型号压缩机型号机组功率制冷量水流量接管规格外形尺寸()安装尺寸()KWWM3/h回气管液管ABCab2FC3.22FC-3.22.055901.716127403405305102902EC3.22EC-3.22.3566602.022128303405605102902DC3.22DC-3.22.6979802.422128303405605102902CC3.22CC-3.23.3198902.922169303706206003204FC5.24FC-5.23.66112303.322161
27、0803706707103204EC6.24EC-6.24.56138604.0281610803706757103204DC7.24DC-7.25.4168304.9282212503706758003204CC9.24CC-9.26.64202505.9282212503706758003204VCS10.24VCS-10.26.61222506.4282212904707708503904TCS12.24TCS-12.28.1268007.7352212904707708503904OCS15.24OCS-15.29.35319509.0352812904707708503904NCS2
28、0.24NCS-20.211.343700010.6422812904707708503904J22.24J-22.212.254090011.7422812904708408503904H25.24H-25.214.24740013.5542812904708408503904G30.24G-30.216.85440015.7542812904708408503906J33.26J-33.218.46140017.65428165060083210005506H35.26H-35.221.37120020.45435165060083210005506G40.26G-40.225.28160
29、023.55435169060083210005506F50.26F-50.231.496500285435209060083212005508GC60.28GC-60.238.7121000357642209060098012005508FC70.28FC-70.248.313850041764223806501035130055044H50.244H-50.228.49480027763521009201130150088044G60.244G-60.233.510880031.3764221009201130150088066J66.266J-66.236.812280035764223
30、809501035130068066H70.266H-70.242.614240041764223809501035130068066G80.266G-80.250.416320047765423809501035130068066F100.266F-100.262.8192900567654238095010351300680 说明:制冷量及功率工况为:-5/40。
31、160;
32、
33、
34、 蒸发风机DL型蒸发冷风机 技术参数
35、 翅片片距:4. 5mm型号Modwl制冷量t库=-25oCt=t库-to=7oKW/h冷却面积m2排管容积dm3风机融霜电热器重量kg风量M3/h直径mm射程m电机功率w功率w电压vDL-1.9/101.92101.81700330101×901.222030DL-3.2/153.21152.9340033010
36、2×901.522043DL-4.3/204.28203.93400330102×901.522050DL-5.5/255.46255.05100330103×901.822059DL-8.0/408.02408.36000400122×2502.122082DL-10.6/5510.565511.16000400122×2502.722098DL-16.3/8016.308016.512000500172×5503.6220165DL-22.4/10522.3810522.712000500172×5504.8220185
37、DL-27.4/12527.4212526.318000500173×5505.58220249DL-33.7/16033.711603318000500173×5506.78220270DL-40.4/18540.0018538.524000500174×5508.1220310DL-45.2/21044.962104424000500174×5508.7220350DL-52.9/26052.922605224000500174×55010.8220380DL-67.2/33057.2533066.224000500174×550
38、13.2220460DL-83.4/41083.4341082.330000500175×55015.6220480DD型蒸发冷风机 技术参数
39、60; 翅片片距:6mm型号制冷量t库=-25oCt=t库-to=7oKW/h冷却面积m2排管容积dm3风机融霜电热器重量kg风量M3/h直径mm射程m电机功率w功率w电压vDD-1.3/71.3071.81700330101×90
40、1.522027DD-2.2/122.23122.93400330102×901.822040DD-2.8/152.79153.93400330102×901.822046DD-3.7/223.72225.05100330103×903.622055DD-5.6/305.62308.36000400122×2504.822078DD-7.4/407.444011.16000400122×2504.822095DD-11.7/6011.726016.512000500172×2507.2220160DD-15.9/8015.888022
41、.712000500172×5509.6220180DD-18.6/10018.610026.318000500173×55011.1220240DD-23.4/12023.361203318000500173×55012220260DD-27.3/14027.2714038.524000500174×55014.4220300DD-31.1/16031.141604424000500174×55016.8220340DD-37.4/20037.422005224000500174×55024220350DD-46.8/25046.8
42、325066.224000500174×55028220400DD-56.2/31056.2131082.330000500175×55031.5220420DJ型蒸发冷风机技术参数 &
43、#160; 翅片片距:96mm型号制冷量t库=-25oCt=t库-to=7oKW/h冷却面积m2排管容积dm3风机融霜电热器重量kg风量M3/h直径mm射程m电机功率W功率w电压vDJ-14./81.398
44、2.93400330102×902.722035DJ-1.8/-121.83123.93400330102×902.722044DJ-2.5/152.49155.05100330103×90322050DJ-3.8/203.81208.36000400122×2504.222095DJ-4.8/304.893011.16000400122×2505.4220107DJ-7.7/407.674016.512000500172×2507.2220157DJ-10.4/5510.415522.712000500172×5509220177DJ-12.8/7012.847026.318000500173×55011.5220232DJ-15.8/8515.7985331800050
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025湖南建投集团春季校园招聘239人笔试参考题库附带答案详解
- 2025浙江湖州市德清国际会议中心有限公司招聘16人笔试参考题库附带答案详解
- 2025河南郑州航空港科创投资集团有限公司“领创”社会招聘40人笔试参考题库附带答案详解
- 2025年银行金融基础知识考试复习题库及答案(共700题)
- 2025春季中国科学院金属研究所职能部门岗位招聘笔试参考题库附带答案详解
- 2025年西安铁路局招聘429人即将结束笔试参考题库附带答案详解
- 2025年合肥高新国有房屋租赁经营有限公司社会招聘14人笔试参考题库附带答案详解
- 2025年福州市名城古厝设计院有限公司招聘4人笔试参考题库附带答案详解
- 2025年山东日照力诚人力资源有限公司招聘外包服务人员6人笔试参考题库附带答案详解
- 宠物行业智能宠物用品开发与营销策略
- GB/T 13384-2008机电产品包装通用技术条件
- 新教科版五年级下册科学期中测试卷(含答案)
- 员工培训请给我结果课件
- 2022年4月自考质量管理(一)试题及答案含评分标准
- 人教精通版五年级下英语unit 4 Revision优秀课件
- 思修坚定理想信念宣讲教育课件
- 两台37kW三相交流电动机的动力配电柜设计
- 拖欠房租起诉书【5篇】
- 医院临时用药申请表
- 农民合作社财务报表(专业应用)
- T∕CIS 71001-2021 化工安全仪表系统安全要求规格书编制导则
评论
0/150
提交评论