常用电力线路阻抗表_第1页
常用电力线路阻抗表_第2页
常用电力线路阻抗表_第3页
已阅读5页,还剩8页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、附录 A 架空线路每千米的电抗、电阻值导线型号6kV10kV35kV110kV220kVx ( )r( )x ( )r( )x ( )r( )x ( )r( )单导线双分裂x ( )r( )x ( )r( )LJ-160.4041.960.4041.96LJ-250.3901.270.3901.27LGJ、 LJ-350.3800.910.3800.910.4240.91LGJ、 LJ-500.3680.630.3680.630.4120.630.4420.63LGJ、 LJ-700.3580.450.3580.450.4020.450.4320.45LGJ、 LJ-950.3420.330.

2、3420.330.3860.330.4160.33LGJ、LJ-1200.3350.270.3350.270.3790.270.4090.27LGJ-1500.3730.210.4030.21LGJ-1850.3650.170.3950.170.4400.1700.3150.085LGJ-2400.3580.130.3880.130.3420.1320.3100.066LGJQ-3000.3820.110.4270.1070.3080.054LGJQ-4000.3730.080.4170.0800.3030.040LGJQ-5000.4110.0650.3000.033LGJQ-6000.40

3、50.0550.2970.028LGJQ-7000.3980.0440.2940.022附录 B 三芯电力电缆每千米的电抗、电阻值芯线截面( mm2 )6kV10kV35kVx ( )r( 铝芯 )()r( 铜芯 )()x ( )r( 铝芯 )()r( 铜芯 )()x ( )r( 铝芯 ) ()r( 铜芯 ) ()250.0851.2800.7400.0941.2800.740350.0790.9200.5400.0880.9200.540500.0760.6400.3900.0820.6400.390700.0720.4600.2800.0790.4600.2800.1320.4600.28

4、0950.0690.3400.2000.0760.3400.2000.1260.3400.2001200.0690.2700.1580.0760.2700.1580.1190.2700.1581500.0660.2100.1230.0720.2100.1230.1160.2100.1231850.0660.1700.1030.0690.1700.1030.1130.1700.103注 1.110kV 高压电缆的平均电抗: X=0.18 /km2. 表中所列为正序电抗 X1, 负序电抗 X2= X1,零序电抗 X0= 3.5X 1附录 C 各电压等级基准值表表 C.1 基准容量 Sb=1000M

5、VA时的基准值表Ub(kV)0.46.310.537115230I b( kA)144091.65515.65.022.51Zb()0.000160.03970.11031.36913.2352.9表 C.2 基准容量 Sb=100MVA时的基准值表Ub(kV)0.46.310.537115230I b( kA)1449.165.51.560.5020.251Zb()0.00160.3971.102513.69132.25529序 号 1 2 3 4 5 6 7 8 9 10附录 D 常用电缆载流量导线型号中试所实验值载流量建议值 (A)载流量原标准值 (A)YJLV22-35100123YJ

6、LV22-50115141YJLV22-70140173YJLV22-95170214YJLV22-120195246YJLV22-150220278YJLV22-185255320YJLV22-240300373YJLV22-300340428YJLV22-400400501导线型号中试所实验值载流量建议值 (A)载流量原标准值 (A)YJV22-35125159YJV22-50145182YJV22-70180223YJV22-95220276YJV22-120255317YJV22-150285359YJV22-185330413YJV22-240385481YJV22-30044055

7、2YJV22-400515646序号12345678910序号123456789导线型号JKLYJ-35JKLYJ-50JKLYJ-70JKLYJ-95JKLYJ-120JKLYJ-150JKLYJ-185JKLYJ-240JKLYJ-300中试所实验值155195239276318366436510载流量建议值 (A)150180225275320365425505载流量原标准值 (A)164198249304352403465553序号导线型号中试所实验值载流量建议值 (A)载流量原标准值 (A)1ZLQ-5065812ZLQ-70851063ZLQ-951001264ZLQ-1201151465ZLQ-1501351716ZLQ-1851551957ZLQ-2401852328ZLQ-300210260序 号导线型号中试所实验值载流量建议值 (A)载流量原标准值 (A)1LGJ-351451752LGJ-501661702103LGJ-7019621

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论