版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、 Ferrite For Switching Power Supplies TECHNICAL DATAEI Cores (EI12.5 to EI60 EE Cores (EE10/11 to EE62.3/62/6EER Cores (EER25.5 to EER42/42/20ETD Cores (ETD19 to ETD49PQ Cores (PQ20/16 to PQ50/50LP Cores (LP23/8 to LP32/13RM Cores (RM4 to RM14EPC Cores (EPC13 to EPC30 EI Series EI12.5 Cores(JIS FEI
2、12.5 Coil: ø0.2 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI12.5 gapped core (TypicalPC40EI12.5 core (TypicalEI12.5 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter m
3、ode100kHz, 200mT PC40EI12.5-Z2120 min. (100kHz, 200mT0.12 max.8.8W (100kHz Note: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.2 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in
4、theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EI Series EI16 Cores(JIS FEI 16 Coil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI16 gapped core (T
5、ypicalPC40EI16 core (TypicalEI16 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI16-Z1100±25% (1kHz, 0.5mA1750 min. (100kHz, 200mT0.31 max.29W (100kHz Note: NI limit shows the point where the excitingcurrent is
6、 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø
7、0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI19 gapped core (TypicalPC40EI19 core (TypicalEI19 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40
8、EI19-Z1830 min. (100kHz, 200mT0.42 max.40W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperatur
9、e and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI22 gapped core (TypicalPC40EI22 core (TypicalEI22 core (Typical Part No.A
10、 L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI22-Z3360 min. (100kHz, 200mT0.60 max.33W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0
11、.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EI Series EI22/19/6 Cores(JIS FEI 22 Coil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L
12、 -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI22/19/6 gapped core (TypicalPC40EI22/19/6 core (TypicalEI22/19/6 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI22/19/6-Z2780 min. (100kHz, 2
13、00mT0.64 max.48W (100kHz Note: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed
14、to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EI Series EI25 Cores Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI25 gapped core (TypicalPC40EI25 core (TypicalEI25 core (TypicalPart No.A L -v
15、alue (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI25-Z2950 min. (100kHz, 200mT0.79 max.68W (100kHz Note: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35
16、2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperatur
17、e rise vs. Total loss for PC40EI28 gapped core (TypicalPC40EI28 core (TypicalEI28 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI28-Z6060 min. (100kHz, 200mT1.65 max.107W (100kHzNote: NI limit shows the point wher
18、e the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300
19、×300cmCoil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI30 gapped core (TypicalPC40EI30 core (TypicalEI30 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter
20、 mode100kHz, 200mT PC40EI30-Z4690±25% (1kHz, 0.5mA6490 min. (100kHz, 200mT3.1 max.155W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The tempera
21、ture rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EI Series EI33/29/13 Cores Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC4
22、0EI33/29/13 gapped core (TypicalPC40EI33/29/13 core (TypicalEI33/29/13 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI33/29/13-Z5980 min. (100kHz, 200mT3.5 max.206W (100kHz Note: NI limit shows the point where the
23、excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×
24、300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI35 gapped core (TypicalPC40EI35 core (TypicalEI35 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode
25、100kHz, 200mT PC40EI35-Z5110 min. (100kHz, 200mT2.85 max.218W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in thero
26、om whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI40 gapped core (TypicalPC40EI40 core (TypicalEI40 core
27、 (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI40-Z6520 min. (100kHz, 200mT4.8 max.348W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring condi
28、tions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air ga
29、p length for Temperature rise vs. Total loss for PC40EI50 gapped core (TypicalPC40EI50 core (TypicalEI50 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EI50-Z8300 min. (100kHz, 200mT9.2 max.508W (100kHzNote: NI limi
30、t shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively.
31、 (approx. 400×300×300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EI60 gapped core (TypicalPC40EI60 core (TypicalEI60 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output p
32、ower (forward converter mode100kHz, 200mT PC40EI60-Z7690 min. (100kHz, 200mT12.5 max.618W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperatu
33、re rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EE Series EE10/11 Cores(JIS FEE 10.2 Coil: ø0.18 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss
34、 for PC40EE10/11 gapped core (TypicalPC40EE10/11 core (TypicalEE10/11 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE10/11-Z1450 min. (100kHz, 200mT0.14 max.9.4W (100kHz Note: NI limit shows the point where the exc
35、itingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.18 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300
36、cm Coil: ø0.18 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EE13 gapped core (TypicalPC40EE13 core (TypicalEE13 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100
37、kHz, 200mT PC40EE13-Z1770 min. (100kHz, 200mT0.235 max.17W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.18 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom
38、whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40SEE16 gapped core (TypicalPC40SEE16 core (TypicalSEE16 core
39、 (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40SEE16-Z1850 min. (100kHz, 200mT0.37 max.32W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring cond
40、itions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EE Series EE20/20/5 Cores(DIN 41295 Coil: ø0.23 2UEW 100TsNI limit vs
41、. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EE20/20/5 gapped core (TypicalPC40EE20/20/5 core (TypicalEE20/20/5 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE20/20/5-Z2
42、270 min. (100kHz, 200mT0.51 max.41W (100kHz Note: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and
43、humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EE Series EE25/19 Cores Coil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EE25/19 gapped core (TypicalPC40EE25/19 core (TypicalEE25
44、/19 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE25/19-Z2570 min. (100kHz, 200mT0.86 max.70W (100kHz Note: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Meas
45、uring conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EE Series EE30/30/7 Cores(DIN 41295 Coil: ø0.35 2UEW 100TsN
46、I limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EE30/30/7 gapped core (TypicalPC40EE30/30/7 core (TypicalEE30/30/7 core (TypicalPart No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE
47、30/30/7-Z3030 min. (100kHz, 200mT1.51 max.133W (100kHz Note: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose tempe
48、rature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EE42/42/15 gapped core (TypicalPC40EE42/42/15 core (TypicalEE42/42/15
49、core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE42/42/15-Z7050 min. (100kHz, 200mT8.0 max.419W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measu
50、ring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm Coil: ø0.35 2UEW 100TsNI limit vs. A L -value forA L -value
51、vs. Air gap length for Temperature rise vs. Total loss for PC40EE55/55/21 gapped core (TypicalPC40EE55/55/21 core (TypicalEE55/55/21 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE55/55/21-Z10830 min. (100kHz, 200
52、mT11.0 max.814W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.35 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to
53、 25°C and 45(%RH. respectively. (approx. 400×300×300cmCoil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs. Air gap length for Temperature rise vs. Total loss for PC40EE50.3/51/6 gapped core (TypicalPC40EE50.3/51/6 core (TypicalEE50.3/51/6 core (Typical Part No.A L -val
54、ue (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE50.3/51/6-Z2900±25% (1kHz, 0.5mA3950 min. (100kHz, 200mT5.83 max.213W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuri
55、ng conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cmCoil: ø0.23 2UEW 100TsNI limit vs. A L -value forA L -value vs.
56、 Air gap length for Temperature rise vs. Total loss for PC40EE62.3/62/6 gapped core (TypicalPC40EE62.3/62/6 core (TypicalEE62.3/62/6 core (Typical Part No.A L -value (nH/N 2Core loss (W at 100°C Calculated output power (forward converter mode100kHz, 200mT PC40EE62.3/62/6-Z3100±25% (1kHz, 0
57、.5mA4150 min. (100kHz, 200mT8.85 max.250W (100kHzNote: NI limit shows the point where the excitingcurrent is 20% and 40% away from its extended linear part.Measuring conditions Coil: ø0.23 2UEW 100Ts Frequency: 1kHz Level: 0.5mANote: The temperature rise is measured in theroom whose temperature
58、 and humidity are fixed to 25°C and 45(%RH. respectively. (approx. 400×300×300cm EER Series EER25.5 Cores(JIS FEER 25.5A Coil: ø0.35 2UEW 100TsNI limit vs. A L-value for A L-value vs. Air gap length for Temperature rise vs. Total loss for PC40EER25.5 gapped core (TypicalPC40EER25.5 core (TypicalEER25.5 core (Typical Part No.A L-value (nH/N2Core loss (W at 100°C Calculated output power(forward converter mode100kHz, 200mTPC40EER25.5-Z2910 min. (100kHz, 200mT0.98 max.87W (100kHzNote: NI limit shows the point where the excitingcurrent
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年度土地使用权开发合作协议(综合交通枢纽)3篇
- 二零二五年度反担保抵押合同诉讼仲裁合同
- 2024施工现场环境风险应急预案编制合同3篇
- 2024年货物买卖承包合同模板3篇
- 2025年落水管安装承包合同范文处理
- 房屋工程风险评估报告范文
- 液压升降平台课程设计
- 二零二五年度原料供应商与某建筑公司砂石料采购合同2篇
- 2024版标识标牌制作合同
- 2024年离婚协议书(双方年龄不足30岁)
- 小学语文课堂提问有效性策略研究方案
- 物业上门维修收费标准
- ATS技术交流(新型发动机智能恒温节能冷却系统)100318
- 手术区皮肤的消毒和铺巾ppt课件
- 日有所诵(二年级)
- 2022年度培训工作总结
- 应急照明装置安装施工方法
- 静力触探技术标准
- 钢结构、膜结构安全技术交底
- DB34∕T 4057-2021 中小河流防汛特征水位分析规程
- 单肺通气技术
评论
0/150
提交评论