1、一、铝合金绞线的规格及主要技术参数标称截面(mm2)结构根数直径(mm)外径(mm)直流电阻(20)(Km)计算拉断力(Kn)计算重量(Kg/Km)计 算 载 流 量(A)7080901016253550709512015018521024030040050063080010007/1.357/1.717/2.137/2.527/3.027/3.577/4.1619/2.8419/3.1719/3.5219/3.7519/4.0137/3.2137/3.7137/4.1561/3.6361/4.0961/4.574.055.136.397.569.0610.7112.1814.2015.851
2、7.6018.7520.0522.4725.9729.0532.6736.8141.133.315962.066731.332040.951650.662620.474180.349210.277450.222690.180610.159130.139170.111810.083700.066890.053100.041830.033512.804.496.979.7514.0019.5726.5733.6241.8851.6458.6167.0283.63111.71139.78176.32223.84279.4627.444.068.295.5137.1191.6260.2330.9412
3、.2508.3576.8659.6825.21102.31379.21742.22211.72761.3597910412715919523427030835037740946655363172182693370941241521912352853303784314665075816957989191061120979106140173218269326379436497539587675810933107812491429注:除载流量计算值外,均摘自GB9329二、钢芯铝绞线的规格及主要技术参数标称截面(mm2)铝钢钢比(S)()结构根数直径(mm)外径(mm)计算拉断力(Kn)计算重量(K
4、g/Km)直流电阻(20)(Km)计 算 载 流 量(A)铝钢70809010/216/325/435/650/850/3070/1070/4095/1595/2095/55120/7120/20120/25120/70150/8150/20150/25150/35185/10185/25185/30185/45210/10210/25210/35210/50240/30240/40240/55300/15300/20300/25300/40300/50300/70400/20400/25400/35400/50400/65400/95500/35500/45500/65630/45630/5
5、5630/80800/55800/70800/1001400/13517171717175817581620586162058613162361316236131623131623579131623579131623791379137913106/1.506/1.856/2.326/2.726/3.2012/2.326/3.8012/2.7226/2.157/4.1612/3.2018/2.9026/2.387/4.7212/3.6018/3.2024/2.7826/2.7030/2.5018/3.6024/3.1526/2.9830/2.8018/3.8024/3.3326/3.2230/2
6、.9824/3.6020/3.4230/3.2042/3.0045/2.9348/2.8524/3.9926/3.8330/3.6042/3.5145/3.3348/3.2254/3.0726/4.4230/4.1645/3.7548/3.6054/3.4445/4.2048/4.1254/3.8745/4.8048/4.6354/4.3388/4.501/1.501/1.851/2.321/2.721/3.207/2.321/3.807/2.727/1.677/1.857/3.201/2.907/1.857/2.107/3.601/3.207/1.857/2.107/2.501/3.607/
7、2.107/2.327/2.801/3.807/2.227/2.507/2.987/2.407/2.667/3.207/1.677/1.957/2.227/2.667/2.987/3.607/1.957/2.227/2.507/3.077/3.4419/2.507/2.507/2.807/3.447/2.807/3.2019/2.327/3.207/3.6019/2.6019/3.004.505.556.968.169.6011.6011.4013.6013.6113.8716.0014.5015.0715.7418.0016.0016.6717.1017.5018.0018.9018.881
8、9.6019.0019.9820.3820.8621.6021.6622.4023.0123.4323.7623.9424.2625.2026.9126.6426.8227.6328.0029.1430.0030.0030.9633.6034.3234.8238.4038.5838.9851.004.1206.1309.29012.63016.87042.62023.39058.30035.00037.20078.11027.57041.00047.88098.37032.86046.63054.11065.02040.88059.42064.32080.19045.14065.99074.2
9、5090.83075.02083.370102.10068.06075.68083.41092.220103.400128.00088.85095.940103.900123.400135.200171.300119.500128.100154.000148.700164.400192.900191.500207.000241.100329.50042.965.2102.6141.0195.1372.0275.2511.3380.8408.9707.7379.0466.8526.6895.6461.4549.4601.0676.2584.0706.1732.6848.2650.7789.185
10、3.9960.8922.2964.31108939.81002105811331210140212861295134915111611186016421688189720602209238826902791299149622.7061.7791.1310.8230.59460.56920.42170.41410.30580.30190.29920.24220.24960.23450.23640.19890.19800.19390.19620.15720.15420.15920.15640.14110.13800.13630.13810.11810.12090.11980.097240.0952
11、00.094330.096140.096360.094630.071040.073700.073890.072320.072360.070870.058120.059120.057600.046330.045140.045510.035470.035740.036350.02138668511113416116619419625223323028728526525832332633133137237937337939740540940944544044549550250550350451259558458359259760867066467676377577488788187812727810
12、013115819119523223030627727035034831530139540040740745846846046949050150750755254655461562462862862964174673072974175276784283485096497997711261121111315638711314918021821826625735131930140139936533545446146946952854053154156557958658663963364171172272672873074586484584485787689597796798311201136113
13、11310130112881808注:除载流量计算值外,均摘自GB1179三、常用钢芯铝合金绞线的规格及技术参数标称截面(mm2)铝钢钢 比结构根数直径(mm)外 径(mm)计算拉断力(Kn)计算重量(Kg/Km)直流电阻(20)(Km)计 算 载 流 量(A)铝铝70809070/1070/4095/1595/55120/7120/20120/70150/8150/25185/10185/30210/10210/35240/30240/40300/20300/50300/70400/25400/50400/951758165861658616616616131671623713236/3.8
14、012/2.7226/2.1512/3.2018/2.9026/2.3812/3.6018/3.2026/2.7018/3.6026/2.9818/3.8026/3.2224/3.6026/3.4245/2.9326/3.8330/3.6045/3.3354/3.0730/4.161/3.807/2.727/1.677/3.201/2.907/1.857/3.601/3.207/2.101/3.607/2.321/3.807/2.507/2.407/2.667/1.957/2.987/3.607/2.227/3.0719/2.5011.4013.6013.6116.0014.5015.0718
15、.0016.0017.1018.0018.8819.0020.3821.6021.6623.4324.2625.2026.6427.6329.1432.5166.7845.7290.4642.4756.05114.5051.4372.0865.0986.9872.52101.35107.85114.48113.70143.62168.36146.97174.67226.01274.7510.1380.2706.0378.5466.1893.6460.9600.1583.3731.5649.9852.5921.0962.91001.01207.91400.01293.71509.61857.40
16、.489300.480580.355080.347220.281140.289710.274350.230900.225150.182440.184380.163740.158300.137120.140330.110540.111890.109870.085580.083990.082281861882372242692682523033113493513733854184144024734815495575722222212892643293282973723834314344614775205155895936046897007232542483312963793773324294424
17、98501533553603597683689703800813845注:除载流量计算值外,均摘自GB9329四、铝绞线规格及主要技术参数标称截面(mm2)结构根数直径(mm)计 算 载 流 量(A)7070701625355070951201501852102403004005006308007/1.707/2.157/2.507/3.007/3.607/4.1619/2.8519/3.1519/3.5019/3.7519/4.0037/3.2037/3.7037/4.1661/3.6361/4.108411213516821025028932737140343549658867476888
18、0100133161202253304353400456497538617738852977112911215118323028934740546052657462271585999511451328 注:除载流量计算值外,均摘自GB11790.6/1kv聚氯乙烯绝缘电力电缆载流量阻燃耐火型亦参照此表适用型号vv.vLv导电线芯最高工作温度70空气温度30土攘温度25土壤热阻系数1。2.m/w 1000/m标称截面2在空气中在地下一芯二芯三芯一芯二芯三芯铜铝铜铝铜铝铜铝铜铝铜铝1.524-20-17-34-27-22-2.532252821231846353528302344534362931
19、246147473639316564347363931755858454938108061665156431058180626852161068389697659138106105828969251431111179110278180138133104107833517513314311112294218169164127131101502231701801381541222651962011591591237026520721717019114831023924418619515095329254238182233180369283280210231178120382297273211270
20、207416323320238262201150445339325242313244474364355272300231185519392370298360281530408407322337262240609472-429334617474-390301300705546-477376700530-451355400832641-820629-500965753-929710-6301134880-1060813-8001351049-1223938-0.6/1kv3+1芯或4芯聚氯乙烯绝缘及护套电力电缆的载流量2适用型号vv.vLv导电线芯最高工温度70l 空气温度30。土壤温度25土壤热
21、阻系数1。2m/w标称截面2在空气中在地下标称截面在空气中在地下铜铝铜铝mm2铜铝铜铝42822372870178136194148638284636952181682311771051406147120253195263204166853806115029822830323325927110682185344263340263351158913010124039029139729850144111161124300438342448356二0.6/1kv聚氯乙烯绝缘及护套电力电缆载流量适用型号vv22VLV22导导电线芯最高准许工作温度70。空气温30。土壤温度25土壤热阻系数;1.2标称截
22、面mm2在空气中在地下一芯二芯三芯一芯二芯三芯铜铝铜铝铜铝铜铝铜铝铜铝4-37293224-453538296-48374032-5643473710826467525745101787759655016111859170776013210410279876625143111122921028017513212597109842517513814311112295212164148115130100502231751801381541222602011811401601237027621221717019114830723822017019515095334260240185233180371
23、286278208229176120387297278215270207424339320229262201150445345319254313244483375361270299229185509398368292360281541419405310334257240615477-424334636493-386298300700541-477371721557-445350400832641-838647-500970747-955743-6301124875-1093849-80013461039-1284987-20.6/1kv3+1芯或4芯聚氯乙烯绝缘及护套电力电缆载流量适用型号vv
24、22,vlv22导电线芯最高准许工作温度70空气温度30,土壤温度25土壤热阻系数;1。2标称截面mm2在空气中在地下标称截面mm2在空气中在地下铜铝铜铝铜铝铜铝42923362770184141196151639294636952261742341811052406147120260201267206167054816215030123130123125947310682185345266338261351199213410324039029438929050149115163125300447345440340三,06/1kv3+2芯4+1芯5芯聚氯乙烯绝缘电力电缆载流量1,适用型号VV,
25、VLV,VV22,VLV22,导电线芯最高工作温度702,空气温度30,土壤温度25土壤热阻系数;1。2标称截面mm2非铠装铠装在空中在地下在空气中在地下铜铝铜铝铜铝铜铝1515-20-2521162821-4262134272521332663725453336254432104636564345345441166047725558457053258264957580629574351088412396107821219450134100151113132981491107016512418113616212218013595203156216165200152212161120236183
26、246192230180241187150281214287219275208280212185328246334251318236324241240367268374275352253360261300418330428341401314412325四,单芯铜导体交联聚乙烯绝缘电力电缆载流量适用型号,YJV,YJV22,YJY,YjV32,YJV33,42,43电缆电压等级,3.6/6kv电压等级3.6/6kv电压等级36/6kv标称截面mm2单芯标称截面mm2单芯在土壤中在空气中在土壤中在空气中251601422405405503518717530060164650220206400680
27、75770276260500772857953303206308619701203703618009601103150410471100010391237185456475120011171321五,06/1kv.-1.8/3kv硅烷交联聚乙烯绝缘电力电缆载流量,该产品的阻燃,耐火产品的载流量参照此计算徝选择1,1-3芯电缆的载流量见表7适用型号;YJV,YJLV,YJY,包括钢带凯装导体最高准许工作温度90空气温度30,土壤温度25土壤热阻系数;1.2标称截面mm2非铠装铠装在空气中在地下在空气中在地下一芯二芯三芯一芯二芯三芯一芯二芯三芯一芯二芯三芯铜铜铜铜铜铜铜铜铜铜铜铜153126224
28、43528-25413630594538-40584640786050-4640-574860726050967463-6051-7160101028572134102871058572129988316136114971771341141421169816813011125183150131230170137183156130225160131352241501562792101682241831562711891625028518319733925720428523019733223120470339230244397312250353277245392281249954212782984
29、72358296428307298464355293120489305346532410335495355345524400355150570350401607454384569408400608438382185664416461678512431651471457662502427240745474549760-499768-542764-494300902-611896-577896-610882-569400995-678990-642991-670987-6385001135-1089-1130-1022-6301352-1257-1350-1239-8001637-1465-163
30、3-1440-注;表中计算值为铜芯载流量。铝芯载流量为铜芯的1/1。29倍六,3+1,3+2,4+1,4芯,5芯电缆载流量,适用型号;yjv,yjy,yjlv,yjly(包括钢带,铠装)导体最高准许工作温度;90空气温度;30土壤温度;25土壤热阻系数;1.2标称截面mm23+1。或,4芯3+2,或,4+1,或5心非铠装铠装非铠装铠装在空气中在地下在空气气在地下在空气中在地下在空气中在地下铝铝铝铝铝铝铝铝2.52226-2026428352834273463646364632421051605160465516687869796070259110493104829635114129117131
31、108122501421581471601281447017418918019015917495215226222231200211120250261257262234245150292298295295274280185337338340334315321240372382376371343352300438456441435422436注,表中给出计算值是铝芯载流量,铜芯栽流量为铝芯的1.29倍,七,单芯铜导体交联聚氯乙烯绝缘电力电缆载流量,适用型号,YJV,YJY,YJV22,电压等级,6/6,6/10kv电压等级6/6,6/10kv电压等级6/6,6/10kv标称截面mm2单芯标称截面
32、mm2单芯在土壤中在空气中在土壤中在空气中25161142240538550351881753006006475022120740068178570287260500770857953313206308629701203673608009571103150400412100010401237185456475120011481319八,单芯铜导体交联聚氯乙烯绝缘电力电缆栽流量,适用型号,yjv,yjy,yjv22,电压等级,8。7/10,8。7/15kv电压等级87/10,8。7/15kv电压等级8.7/10,8.7/15kv标称截面mm2单芯标称截面mm2单芯在土壤中在空气中在土壤中在空气中
33、25160142240540557351871753006006485022720640068275570278260500772856953313206308619701203803608009601103150412417100010091237185457480120010391321九,单芯铝导体交联聚氯乙烯绝缘电力电缆载流量,适用型号,YJLV,YJLY,JLV22,YJLY22,电压等级,3。6/6kv,电压等级3.6/6kv电压等级3.6/6kv标称截面mm2单芯标称截面mm2单芯在土壤中在空气中在土壤中在空气中2512912524041744135140138300469508
34、5018216940053058770207207500601687952492486306978021202892908007719271503213411000867104018536037512009171127十,单芯铝导体交联聚氯乙烯绝缘电力电缆载流量,适用型号,YJLV,YJLY,YJLV22,YJLY22电压等级,6/6KV,6/10KV,电压等级6/6kv,6/10,kv电压等级6/6kv,6/10kv标称截面mm2单芯标称截面mm2单芯在土壤中在空气中在土壤中在空气中2513012724042044035141139300467508501831674005325877020
35、62005006006879525024963069680012029029080077092615032034010008671038185361376120091711217十一,单芯铝导体交联聚氯乙烯绝缘电力电缆栽流量,适用型号,YJLV,YJLY,YJLV22,YJLY22,电压等级,8。7/10,8。7/15,电压等级8.7/10KV,.8.7/15KV电压等级8.7/10KV.,8.7/15KV标称截面mm2单芯标称截面mm2单芯在土壤中在空气中在土壤中在空气中2513012524042044735142138300469507501811694005315867020520550
36、0600687952482466306978021202892918007729261503203421000867104118536138112009171128十二,三芯铜导体交联聚乙烯绝电力电缆载流量,适用型号,YJV,YJY,YJV22,YJY22电压等级6/6KV电压等级6/6KV标称截面mm2三芯标称截面mm22三芯在土壤中在空气中在土壤中在空气中2515013624053052035184167300600594502212004007025925250095320299630120360341800150413395100018548543361200电压等级,3。6/6KV十
37、三,三芯铜导体交联聚乙烯绝缘电力电缆载流量,适用型号,YJV,YJY,YJV22,YJY22电压等级,6/6KV,6/10KV电压等级6/6KV,6/10KV电压等级6/6KV,6/10KV标称截面mm2三芯标称截面mm2三芯在土壤中在空气中在土壤中在空气中25150137240532520351841683006055935022020070260252953232981203643401504143951854594368十四,三芯铜导体交联绝缘电力电缆载流量,适用型号,YJV,YJY,YJV22,YJY22,电压等级,8。7/10KV,8.7/15KV,电压等级8.7/10KV,8.7/15KV电压等级8.7/10KV,8.7/15KV标称截面mm2三芯标称截面mm2三芯在土壤中在空气中在土壤中在空气中2515113712036435935184168150416390502232001854564477026925024053252095325299300600584十五,三芯铝导体交联聚乙烯绝缘电力电缆载流量,适用型号,YJLV,YJLY,YJLV22,YJLY22电压等级,3.6/6KV电压等级3.6/6KV电压等级3.6/6KV标称
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 项目评审真实性保证
- 网络服务合同的社会责任
- 环保服务技术合作合作协议
- 招标文件简化版本解析
- 经销商提成激励购销合同
- 礼品订购合同
- 合同违约责任详尽版
- 机床采购合同签订步骤与注意事项
- 宣传品选购协议
- 网上打车应用合同
- 2022届高考英语写作之读后续写三篇(素材)
- 湘教版数学八上2.6.2用尺规作三角形 教案
- 《全球贸易安全与便利标准框架》中文版
- 亚朵酒店集团 员工入职培训计划
- 受限空间安全作业票填写模板(2022年更新)
- ASPEN-培训教材 13-ASPEN-MTBE装置
- IPD 新产品开发流程
- YZP系列冶金及起重用变频调速三相异步电动机
- 《中国音乐分类》PPT课件
- 第7章墨水中的流变特性及流变调节剂
- 抽凝机组原则性热力系统计算
评论
0/150
提交评论