已阅读5页,还剩29页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
2017/11/3,1,HPLC Column and System Troubleshooting 色谱柱和色谱系统的故障检修,What Every HPLCUser Should Know每个HPLC使用者应该知道什么,请访问中国色谱网(www.SeP),2017/11/3,2,HPLC Components HPLC 的组成,Pump 泵 Injector/Autosampler 进样器/自动进样器 Column 色谱柱 Detector 检测器 Data System/Integrator 数据系统/积分仪表All of these components can have problems and require troubleshooting. 所有这些部件可能出现故障而需要检修。,2017/11/3,3,Categories of Column Problems 色谱柱问题的类型,A. Pressure 压力 B. Peak shape 峰形 C. Retention 保留时间,2017/11/3,4,Pressure Issues压力问题,Column Observations Potential Problems色谱柱观测 潜在的问题 High pressure Plugged frit 压力高 堵塞滤头 Column contamination 色谱柱污染 Piugged packing 堵塞填料,2017/11/3,5,Determining the Cause and Correcting High Back Pressure 查出原因 纠正压力,Check pressure with/without column - many pressure problems are due to blockages in the system or guard有无柱子时检查压力 许多压力问题是由于系统或保护柱的阻塞If Column Pressure is high 如果柱压高:Wash column - Eliminate column contamination and 冲洗柱子 plugged packing 排除柱污染和填料堵塞 - high molecular weight/adsorbed compounds 高分子量被吸附化合物 - precipitate from sample or buffer 样品或缓冲液中的沉淀物Back flush column - Clear plugged frit 反冲柱子清洁阻塞的滤头Change frit - Clear plugged frit 更换滤头,2017/11/3,6,Column Cleaning 柱子清洗,F lush with stronger solvents than your mobile phase用比你的流动相更强的溶剂冲洗 Reversed-Phase Solvent Choices in Order of Increasing Strength 为了增加强度选择反相溶剂Use at least 25 ml of each solvent for analytical columns 对于分析柱每种溶剂至少用25 ml 冲洗Mobile phase without buffer salts 没有缓冲盐的流动相100% Methanol 甲醇100% Acetonitrile 乙腈75% Acetonitrile :25% Isopropanol 75乙腈 : 25异丙醇100% Isopropanol 异丙醇100% Methylene Chloride 二氯甲烷100% Hexane 已烷 When using either Hexane or Methylene Chloride the column must be flushed with Isopropanol before returning to your resvered-phase mobile phase.当用已烷蔌二氯甲烷柱子时,必须先用异丙醇冲洗,然后再用你的反相流动相,2017/11/3,7,Column Cleaning柱子清洗,Normal Phase Solvent Choices in Order of Increasing Strength为了增加强度选用正相溶剂Use at least 50 ml of each solvent 每种溶剂至少用50 ml 50% Methanol : 50% Chloroform 50% 甲醇 : 50% 氯仿100% Ethyl Acetate 乙酸乙酯,2017/11/3,8,How to Change a Frit 怎样更换滤头,Column Inlet Frit 柱进口滤头Column Body 柱身Compression Ferrule 压缩金属套圈Wear gloves 戴手套Do not allow bed to dry 不要让底座干燥Do not touch the column-body heat will extrude packing 不要使柱身受热,否则填料会喷出Do not over tighten 不要旋得太紧Female End Fitting 旋好尾端螺母Male End Fitting 旋好尾端螺头,2017/11/3,9,Preventing Back Pressure Problems压力问题的预防,Use column protection 柱保护 - Guard columns 保护柱/预柱 - In-line filters 在线过滤器 Sample Preparation 样品预处理Appropriate column flushing 适当的柱冲洗Filter buffered mobile phase 过滤缓冲流动相,2017/11/3,10,Preventing Back Pressure Problems:In-Line Devices 压力问题的预防:在线装置,Mobile Phase Pre-Column Injector Filter GuardFrom Pump 预柱 进样器 滤头 Column从泵来的流动相 保护柱 Analytical ColumnFilter and Guard Column Act on Sample 分析柱 滤头和保护柱作用于样品 Pre-Column Acts on Mobile Phase 预柱作用于流动相 To Detector 到检测器,2017/11/3,11,Preventing Back Pressure Problems: Sample Preparation压力问题的预防:样品制备,Solvent/Chemical Environment 溶剂/化学环境Particulate/Aggregate Remove 微粒/凝聚物的除去Filter samples 过滤样品Centrifugation 离心分离Solid Phase Extraction(S.P.E.) 固相萃取Cartridges or Plates 薄膜或薄层板Disks or Membranes 圆盘或生物膜,2017/11/3,12,Peak Shape Issues 峰形问题,Split peaks 裂峰 Peak tailing 峰拖尾 Broad peaks 宽峰Poor efficiency 低柱效Many peak shape issues also combinations-I.e. Broad and tailing or tailing with increased retention许多峰形问题是结合在一起的-例如:展宽和拖尾或拖尾和保留时间增加,2017/11/3,13,Split Peaks 裂峰,Can be caused by: 可能的原因:Column contamination 柱污染Partially plugged frit 部分阻塞滤片Column void 柱头塌陷Injection solvent effects 溶剂效应,2017/11/3,14,Split Peaks 裂峰Column Contamination 柱污染,Column: StableBond SB-C8, 4.6 250mm, 5mMobile Phase:60%25mM Na2HPO4,pH3.0 : 40%MeOHFlow Rate: 1.0 mL/min Temperature: 35CDetection: UV 254 nmSample: Filtered OTC Cold Medication: 1. Pseudoephedrine 2. APAP 3. Unknown 4. ChlorpheniramineInjection 1 峰3 峰形较好Injection 30 峰3 裂峰Injection 1 After Column Wash with 100% CAN经100%乙腈冲洗后 峰3 峰形极好,2017/11/3,15,Split Peaks 裂峰Injection Solvent Effects 溶剂化效应,Column: StableBond SB-C8, 4.6 250mm, 5mMobile Phase: 82%H2O : 18%ACNInjection Volume: 30 L Sample: 1. Caffeine 咖啡因 2. Salicylamide 水杨酰胺A. Injection Solvent B. Injection Solvent 100% Acetonitrile Mobile Phase 峰形宽拖尾 峰形尖锐对称样品溶剂尽可能与流动相匹配,2017/11/3,16,Determining the Cause of Split Peaks 裂峰原因的确定,1. Complex sample matrix or many samples analyzed- likely column contamination or partially plugged frit复杂样品的基质或分析许多样品 - 柱污染或部分阻塞滤片 2. Mobile phase pH=7 - likely column void due to silica dissolution (unless specialty column used)流动相 pH=7 - 由于硅胶溶解使柱塌陷(除非使用专门的柱子) 3. Injection solvent stronger than mobile phase - likely split and broad peaks, dependent on volume溶剂比流动相的可能性大- 裂峰和宽峰,由样品量来决定,2017/11/3,17,Peak Tailing, Broadening and Loss of Efficiency峰拖尾、变宽和柱效降低,Can be caused by: 可能的原因 Column “secondary interactions”柱“次级效应”Column void 柱塌陷Column contamination 柱污染Column aging 柱老化Column loading 柱负荷超载Extra-column effects 柱外效应,2017/11/3,18,Peak Tailing Column “Secondary Interactions”峰拖尾柱“次级效应”,Column: Alkyl-C8, 4.6 150mm, 5mMobile Phase:85%25mM Na2HPO4,pH7.0 : 15%ACNFlow Rate: 1.0 mL/min Temperature: 35CSample: 1. Phenylpropanolamine 苯丙醇胺去甲麻黄碱 2. Ephedrine 麻黄碱 3. Amphetamine 安非他明苯丙胺4. Methamphetamine 脱氧麻黄碱 5. Phenteramine 苯三胺No TEA 无三乙胺 10 mM TEA 10 mM 三乙胺USP TF(5%) 美国药典拖尾因子 USP TF(5%) 美国药典拖尾因子1. 1.29 1. 1.192. 1.91 2. 1.18 3. 1.63 3. 1.204. 2.35 4. 1.265. 1.57 5. 1.14Peak tailing eliminated with mobile phase modifier (TEA) at pH 7用流动相减尾剂(三乙胺)在pH 7 消除峰拖尾,2017/11/3,19,Peak Tailing Column “Secondary Interactions”峰拖尾柱“次级效应”,Column: Alkyl-C8, 4.6 150mm, 5mMobile Phase:85%25mM Na2HPO4,pH7.0 : 15%ACNFlow Rate: 1.0 mL/min Temperature: 35CSample: 1. Phenylpropanolamine 苯丙醇胺去甲麻黄碱 2. Ephedrine 麻黄碱 3. Amphetamine 安非他明苯丙胺4. Methamphetamine 脱氧麻黄碱 5. Phenteramine 苯三胺 pH 3.0 pH 7.0 USP TF(5%) 美国药典拖尾因子 USP TF(5%) 美国药典拖尾因子 4. 1.33 4. 2.35Reducing the mobile phase pH reduces interactions with silanols that cause peak tailing降低流动相的pH ,减小与硅醇基作用引起的峰拖尾,2017/11/3,20,Peak Tailing 峰拖尾Column Contamination 柱污染,Column: StableBond SB-C8, 4.6 250mm, 5mMobile Phase: 20% H2O : 80% MeOH Flow Rate: 1.0 mL/min Temperature: R.T. Detection: UV 254 nmSample: 1. Uracil 尿嘧啶 2. Phenol 苯酚 3. 4-Chloronitrobenzene 4-氯硝基苯 4. Toluene 甲苯Plates TF Plates TF Plates TF理论板数 拖尾因子 理论板数 拖尾因子 理论板数 拖尾因子1. 7629 2.08 1. 7906 1.43 1. 7448 1.062. 12043 1.64 2. 12443 1.21 2. 12237 1.213. 13727 1.69 3. 17999 1.19 3. 15366 1.114. 13355 1.32 4. 17098 1.25 4. 19067 1.17QC test forward direction QC test reverse direction QC test after cleaning 100% IPA, 35C 向前方向 相反方向 100%异丙醇冲洗后,2017/11/3,21,Peak Tailing/Broadening Sample Load Effects峰拖尾/变宽样品过载效应,Column: 4.6 150mm, 5mMobile Phase:40%25mM Na2HPO4,pH7.0 : 60%ACNFlow Rate: 1.5 mL/min Temperature: 40CSample: 1. Desipramine 去郁敏/脱甲基丙米嗪 2. Nortriptyline 3. Doxepin 4. Imipramine 丙米嗪 5. Amitriptyline 阿米替林 6. TrimipramineTailing Eclipse XDB-C8 Broadening / Competitive C8USP TF 拖尾因子 Plates 理论板数 High Load / 10 Low Load High Load / 10 Low Load高载负/10倍 低载负 高载负/10倍 低载负1. 1.60 1.70 850 59412. 2.00 1.90 815 78423. 1.56 1.56 2776 6231 4. 2.13 1.70 2539 8359 5. 2.15 1.86 2735 10022 6. 1.25 1.25 5189 10725,2017/11/3,22,Peak Broadening,Splitting Column Void 峰变宽,裂开 柱塌陷,Mobile Phase:流动相:50%CAN : 50%Water : 0.2%TEA (pH 11)50乙腈 : 50水 : 0。2三乙胺 (pH 11) After 30 injections Initial 开始时 进样30次后Multiple peak shape changes can be caused by the same column problem. In the case a void resulted from silica dissolved at high pH.多数峰形改变可能是同一柱问题引起的。在这个例子中,高pH溶解硅胶导致塌陷,2017/11/3,23,Broad Peaks Unknown “Phantom” Peaks,Column: Extend-C18, 4.6 150 mm, 5 mMobile Phase: 40% 10 mM TEA, pH 11 : 60% MeOHFlow Rate: 1.0 mL/min Temperature: R.T. Detection: UV 254Sample: 1. Maleat 顺丁烯二酸 2. Pseudeophedrine 伪麻黄碱 3. Chlorphenniramine 氯非尼拉明Plates 理论板数1. 5922 2. 98793. 779 “Phantom” peak from first injection 前次进样未出完的峰The extremely low plates are an indication of an extremely late eluting peak from the preceding run.极低的理论板数表明这是一个前面进样极迟洗脱出来的峰,2017/11/3,24,Peak Tailing峰拖尾 Injector Seal Failure进样器密封性差,Column: Bonus-RP, 4.6 75mm, 3.5mMobile Phase: 30% H2O : 70% MeOH Flow Rate: 1.0 mL/min Temperature: R.T. Detection: UV 254 nmSample: 1. Uracil 尿嘧啶 2. Phenol 苯酚 3. N,N-Dimethylaniline N,N-二甲苯胺Plates TF Plates TF 理论板数 拖尾因子 理论板数 拖尾因子 1. 2235 1.72 1. 3670 1.452. 3491 1.48 2. 10457 1.09 3. 5432 1.15 3. 10085 1.00 Before After replacing rotor seal and isolation seal之前 转动杆和隔离密封垫检修后Overdue instrument maintenance can cause peak shape problems.仪器保养超期可能引起峰形问题/进样器划痕,2017/11/3,25,Peak Tailing 峰拖尾Extra-Column Volume 柱外死体积效应,Column: StableBond SB-C18, 4.6 30mm, 3.5mMobile Phase: 85% H2Owith 0.1% TFA : 15% CANFlow Rate: 1.0 mL/min Temperature: 35C Sample: 1. Phenylalanine 2. 5-benzyl-3,6-dioxo-2-piperazine 3. Asp-phe 4. Aspartame10 l extra-column volume 50 l extra-column volume,2017/11/3,26,Determining the Cause of Peak Tailing峰拖尾原因的确定,Evaluate mobile phase effects - alter mobile phase pH and additives to eliminate secondary interactions 评价流动相效果 - 改变流动相pH和添加剂消除次级效应/流动相中组份与柱子相互作用Evaluate column choice - try column with high purity silica or different bonding technology 评价柱选择 - 试用高纯度硅胶柱或不同键合技术柱Reduce sample load 减小进样量Eliminate extra-column effects 消除柱外效应Flush column and check for aging/void 冲洗柱子检查柱子老化/塌陷,2017/11/3,27,Retention Issues保留时间问题,Retention time changes(tr) 保留时间改变Capacity factor (retention) changes (k) 容量因子改变Selectivity changes () 选择性改变,2017/11/3,28,Changes in Retention Same Column, Over Time相同柱子上保留时间改变,超时,May be cause by: 可能的原因:Column aging 柱老化Column contamination 柱污染Insufficient equilibration 不够平衡Poor column/mobile phase combination 柱/流动相组成差Change in mobile phase 改变流动相Change in flow rate 改变流速other instrument issues 其他仪器问题,2017/11/3,29,Mobile phase Change Causes Change in Retention流动相改变引起保留时间改变,60%MeOH:40% 0.1% TFA Fresh TFA Added to Mobile PhaseVolatile TFA evaporated/degassed from mobile phase. 易挥发的三氟乙酸从流动相中蒸发/挥发。Replacing it solved problem. 换用新的流动相就解决问题。使用有机挥发性酸时,流动相应新配。,2017/11/3,30,Column Aging/Equilibration Causes Retention/Selectivity Changes柱老化平衡不够引起保留时间选择性改变,Column 1 - Initial 1 号柱 开始时Column 1 - Next Day 1 号柱 第二天 Column 1 - After Cleaning with 1% H3PO4 1 号柱用 1% H3PO4 清洗 The primary analyte was sensitive to mobile phase aging of the column. 最初的分析对流动相老化柱子是灵敏的The peak shape was a secondary issue resolved by flushing the column. 冲洗柱子第二要解决的问题是峰形Retention and peak shape were as expected after cleaning. 清洗后保留时间和峰形都达到了预期效果,2017/11/3,31,Determining the Cause of Retention Changes on the same Column同一柱上保留时间改变原因的确定,1. Determine K, , and tr for suspect peaks 对怀疑峰K, 和tr的确定 2. Wash column 冲洗柱子3. Test new column - note lot number 试验新柱- 记录一批数据4. Rev
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 第24课《三顾茅庐》课件+2024-2025学年统编版语文九年级上册
- 石河子大学《学前教育学》2022-2023学年第一学期期末试卷
- 社区精神卫生服务与护理
- 石河子大学《社会统计学》2022-2023学年第一学期期末试卷
- 石河子大学《机械设计》2023-2024学年第一学期期末试卷
- 沈阳理工大学《中外建筑史》2021-2022学年第一学期期末试卷
- 沈阳理工大学《现代应用光学》2022-2023学年第一学期期末试卷
- 沈阳理工大学《计算机网络技术基础》2021-2022学年期末试卷
- 沈阳理工大学《光电检测技术》2023-2024学年期末试卷
- 沈阳理工大学《单片机原理与接口技术》2023-2024学年期末试卷
- 有机磷农药中毒课件-整理
- 轮对故障发生的原因和危害分析及其防范措施
- 汽修厂搞个优惠活动
- 底栖生物调查方法与分类鉴定
- GNSS定位测量-GNSS定位原理(工程测量)
- 雨污分流管网施工组织设计方案
- 喷口送风计算
- 2023年土石方运输车队合同(4份范本)
- 连续性肾脏替代治疗CRRT血液净化常见报警及对策
- 地铁工程机电安装施工组织设计
- 三极管课件完整版
评论
0/150
提交评论