已阅读5页,还剩5页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1 文章在文章在 90 年代初出现 国内年代初出现 国内 2000 年后 年后 03 年参加放疗标年参加放疗标 准化临床试验 准化临床试验 06 08 09 年还有技术改进文章年还有技术改进文章 Published Online August 21 2006 Original Article An evaluation of three tangential breast irradiation techniques in Hong Kong Maria Y Y Law a1c1 Fion W K Cheung a1 Vincent W C Wu a1 Venus W C Tsang a1 Rainnie W Y Kwan a1 Johnny Y T Cheng a1 and Fatson K F Wong a1 a1 Department of Optometry and Radiography Hong Kong Polytechnic University Hong Kong Article author query law my PubMed Google Scholar cheung fw PubMed Google Scholar wu vw PubMed Google Scholar tsang vw PubMed Google Scholar kwan rw PubMed Google Scholar cheng jy PubMed Google Scholar wong fk PubMed Google Scholar Abstract Background and Purpose Loco regional radiotherapy after breast conserving surgery significantly reduces the risk of recurrence but may induce complications in the lungs The complications are related to the lung volume irradiated and the lung dose delivered The purpose of this study was to evaluate three tangential breast irradiation techniques i e conventional technique gantry tilting technique and half beam block technique in terms of the percentage of irradiated lung volume and high dose lung volume for patients of different sizes Materials and Method Treatment planning of the three tangential breast irradiation techniques was performed using the CT scans of 20 patients with early stage breast cancer after lumpectomy Results When compared with conventional technique both half beam block technique and gantry tilting technique irradiated a significantly smaller percentage of lung volume and delivered a smaller percentage of high dose above 30 Gy volume in the lung Patients with large breasts had a significantly higher percentage of lung volume irradiated to above 30Gy than those patients with small and medium breasts The combined effect of tangential separation and technique only produced significant effect on the percentage of total lung volume irradiated but not on the high dose volume Conclusions Gantry tilting and half beam block techniques can reduce a significant amount of lung volume and high dose lung volume Half beam block technique is recommended for small and medium breast size while for large breast size gantry tilting technique is preferred 2006 online Journal of Radiotherapy in Practice 2000 2 1 9 15 Cambridge University Press Copyright 2000 Cambridge University Press doi 10 1017 S1460396900000030 Original Article An evaluation of three tangential breast irradiation techniques in Hong Kong Maria Y Y Law a1c1 Fion W K Cheung a1 Vincent W C Wu a1 Venus W C Tsang a1 Rainnie W Y Kwan a1 Johnny Y T Cheng a1 and Fatson K F Wong a1 a1 Department of Optometry and Radiography Hong Kong Polytechnic University Hong Kong Article author query law my PubMed Google Scholar cheung fw PubMed Google Scholar wu vw PubMed Google Scholar tsang vw PubMed Google Scholar kwan rw PubMed Google Scholar cheng jy PubMed Google Scholar wong fk PubMed Google Scholar Abstract Background and Purpose Loco regional radiotherapy after breast conserving surgery significantly reduces the risk of recurrence but may induce complications in the lungs The complications are related to the lung volume irradiated and the lung dose delivered The purpose of this study was to evaluate three tangential breast irradiation techniques i e conventional technique gantry tilting technique and half beam block technique in terms of the percentage of irradiated lung volume and high dose lung volume for patients of different sizes Materials and Method Treatment planning of the three tangential breast irradiation techniques was performed using the CT scans of 20 patients with early stage breast cancer after lumpectomy Results When compared with conventional technique both half beam block technique and gantry tilting technique irradiated a significantly smaller percentage of lung volume and delivered a smaller percentage of high dose above 30 Gy volume in the lung Patients with large breasts had a significantly higher percentage of lung volume irradiated to above 30Gy than those patients with small and medium breasts The combined effect of tangential separation and technique only produced significant effect on the percentage of total lung volume irradiated but not on the high dose volume Conclusions Gantry tilting and half beam block techniques can reduce a significant amount of lung volume and high dose lung volume Half beam block technique is recommended for small and medium breast size while for large breast size gantry tilting technique is preferred Published Online August 21 2006 Key Words Breast cancer radiotherapy technique tangential irradiation Correspondence c1 Correspondence to Maria Law Department of Optometry and Radiography Hong Kong Polytechnic University Hung Hom Kowloon Hong Kong E mail ormaria polyu edu hk PreviousNext International Journal of Radiation Oncology Biology Physics Volume 19 Issue 4 Pages 1037 1040 October 1990 A nondivergent three field matching technique for breast irradiation James C H Chu Ph D AFFILIATIONS Reprint requests to James C H Chu Ph D Department of Radiation Oncology Fox Chase Cancer Center 7701 Burholme Ave Philadelphia PA 19111 Lawrence J Solin M D Chin Chang Hwang M S Barbara Fowble M D Gerald E Hanks M D Robert L Goodman M D Accepted 26 April 1990 Abstract Abstract References PDF References Abstract Effective radiation therapy to intact breasts requires the delivery of adequate dose to a large target volume using complex beam arrangements A semi empirical method is described to determine the correct gantry collimator and couch positions for a geometrically accurate field match among adjoining radiation beams The technique uses a metal rod and chain combination to aid determination of the proper couch setting under remote fluoroscopy control A couch position error of more than half a degree is easily detectable by this technique Keywords Breast irradiation Field matching TECHNICAL NOTE A virtual matching technique for three field breast irradiation using 3 D planning Purchase 31 50 Jonathan B Straussa Michael C Kirka 1 Sea S Chena Anand P Shaha Benjamin T Gieldaa James C Chua Julius V Turiana and Adam Dicklerb aRush University Medical Center Department of Radiation Oncology Chicago IL 60612 USA bLittle Company of Mary Hospital Department of Radiation Oncology Evergreen Park IL 60805 USA Received 1 August 2008 revised 10 January 2009 accepted 3 March 2009 Available online 3 April 2009 Abstract Patients with breast cancer are often treated with radiation to the breast or chest wall and draining regional lymph nodes This is typically performed with a three field technique in which an anterior supraclavicular field is matched to opposed tangent fields A single isocenter technique is not always possible Several techniques have been described to create a perfect match using a conventional simulator We describe and test a simple fast and accurate technique to estimate the couch and collimator angles required for a perfect geometric match using 3 D treatment planning software This method requires no mathematical formulae and is verifiable relative to patient anatomy An external skin contour is created on the axial slice at the match line and displayed with a 3 D representation Using a beam s eye view BEV of a tangent field small couch and collimator rotation adjustments are made sequentially until the contour edges are superimposed The virtual external contour technique was easy to use gave verification of the match in the BEV and yielded estimates of couch and collimator rotations very close to those calculated using published formulae Keywords Breast cancer Radiation Field matching Three field technique Article Outline Introduction Technique Simulation Treatment planning Example Results Discussion References 2 四分之一野的剂量匹配好四分之一野的剂量匹配好 而转床的剂量匹配差些 定位要求高 胶片剂量验证 1 Int J Radiat Oncol Biol Phys 1994 Feb 1 28 3 753 60 Links A mono isocentric technique for breast and regional nodal therapy using dual asymmetric jaws 单个等中心及不对称野的乳腺及区域淋巴结治疗技术单个等中心及不对称野的乳腺及区域淋巴结治疗技术 Klein EE Taylor M Michaletz Lorenz M Zoeller D Umfleet W Washington University School of Medicine Mallinckrodt Institute of Radiology St Louis MO 63110 PURPOSE Definitive radiation therapy for breast cancer with regional nodal involvement often introduces treatment of adjacent abutted regions Many methods describe techniques to achieve an effective transverse plane match Our facility recently adopted a matching technique using asymmetric jaws to beam split all portals along the central axis plane Our technique uses one isocenter to treat the opposed tangential breast fields the supraclavicular port and the posterior axillary field METHODS AND MATERIALS Our linear accelerator has four collimator jaws capable of being set independently The longitudinal Y jaws beam split all the portals at the match plane namely the upper border of the tangential beams and the bottom border of the nodal fields The transverse X jaws define the lateral borders of the nodal fields and in a near beam split fashion in conjunction with customized Cerrobend block the lung for the tangential beams The unique isocenter is chosen along the mid bridge through the tangential match plane Dosimetric qualities and calculational techniques of the asymmetric beams were analyzed with ionimetric water scans ion chamber studies and film The match line is clinically confirmed with composite port films RESULTS 1 Our dosimetric studies show asymmetric jaws provide nearly equivalent field edge definition and superior absorption in comparison with Cerrobend blocks The use of one isocenter results in a reduction of in room treatment time by a factor of two The burden of lifting heavy Cerrobend blocks has been removed A composite port film which includes the medial tangential and supraclavicular ports shows a perfect match line in all cases 胶片剂量测量表明切线野与锁骨上野得到完全匹配 胶片剂量测量表明切线野与锁骨上野得到完全匹配 2 Similar composite port films taken with our previous technique of geometric matching with collimator and table angulation exhibit slight overlap or underdose regions in many cases 转床的剂量匹配略差 常有些过或欠剂量 转床的剂量匹配略差 常有些过或欠剂量 CONCLUSION Our treatment technique takes full advantage of dual asymmetric jaws 四分之一野 to achieve a perfect match line necessitates only one isocenter and set up point and supplies more absorption in reference to lung and contralateral breast dose The pure match line is accompanied by the fact that the patient does not have to move in any direction 理想 理想 的匹配线要求病人不得移动 的匹配线要求病人不得移动 PMID 8113122 PubMed indexed for MEDLINE 3 找原文 找原文 四分之一野 1 Int J Radiat Oncol Biol Phys 1990 Jul 19 1 183 8 A technique for treating local breast cancer using a single set up point and asymmetric collimation Rosenow UF Valentine ES Davis LW Department of Radiation Oncology Albert Einstein College of Medicine NY NY Using both pairs of asymmetric jaws of a linear accelerator local regional breast cancer may be treated from a single set up point This point 是位于匹配线处 is placed at the abutment of the supraclavicular fields with the medial and lateral tangential fields Positioning the jaws to create a half beam superiorly permits treatment of the supraclavicular field Positioning both jaws asymmetrically at midline to define a single beam in the inferoanterior quadrant 四分之一野 permits treatment of the breast from medial and lateral tangents The highest possible matching accuracy 最高的匹配精度 最高的匹配精度 between the supraclavicular and tangential fields is inherently provided by this technique For treatment of all fields at 100 cm source to axis distance SAD the lateral placement and depth of the set up point may be determined by simulation and simple trigonometry We elaborate on the clinical procedure For the technologists treatment of all fields from a single set up point is simple and efficient 对技术员而言 所有野只用一个等中心更简单有效 对技术员而言 所有野只用一个等中心更简单有效 Since the tissue at the superior border of the tangential fields is generally firmer than in mid breast 由于切线野的上边界与中部乳房相比是更固定 由于切线野的上边界与中部乳房相比是更固定 greater accuracy in day to day set up is permitted 重复定位更准确 重复定位更准确 This technique eliminates the need for table angles even when tangential fields only are planned 无需转床 无需转床 Because of half beam collimation the limit to the tangential field length is 20 cm Means will be suggested to overcome this limitation in the few cases where it occurs Another modification is suggested for linear accelerators with only one independent pair of jaws PMID 2380084 PubMed indexed for MEDLINE 4 1 Med Dosim 1994 Summer 19 2 107 10 Links Three field breast irradiation technique using tangential quarter fields Li C Torigoe EW Dunning A Halberg F Evans R Radiation Oncology Department Marin General Hospital Greenbrae CA 94904 We have developed and implemented in clinical practice an isocentric three field breast irradiation technique using tangential quarter fields In this technique the same isocenter is used for the supraclavicular and the tangential breast fields The superior posterior corner of the tangential breast fields is placed at the central axis by asymmetric collimation of both the length and the width of the field Consequently the beam divergence at both the superior and posterior edges is eliminated allowing a perfect geometric match between the posterior borders of both tangential breast fields and the supraclavicular field without table rotation Compared to conventional techniques requiring table rotations the present method produces a more uniform dose distribution in the target volume and requires significantly less simulation time 此技术在靶 此技术在靶 体积内产生更均匀的剂量体积内产生更均匀的剂量 模拟定位的时间减少 模拟定位的时间减少 PMID 7916976 PubMed indexed for MEDLINE 5 四分之一野 四分之一野 1 Radiother Oncol 1993 Sep 28 3 228 32 Links Three field isocentric breast irradiation using asymmetric jaws and a tilt board Marshall MG Department of Radiology Bowman Gray School of Medicine Wake Forest University Winston Salem NC 27157 1088 Perfect abutment of medial and lateral tangential breast portals with the adjacent supraclavicular field may be achieved with ease A simple and safe approach was developed using a tilt board and new technology that is standard on a popular linear accelerator The patient is secured on a tilt board as a means to level the chest wall Isocenter is placed at depth on the matchline where asymmetric jaws are used to produce non divergent field edges and a perfect abutment This is done without the need for table or collimator rotations beam splitters or vertical cephalad blocks The dorsal beam edge of the tangents is made coplanar by rotating the gantry more than 180 degrees This procedure produces a dosimetrically sharp field edge 在剂量上得到清晰的野边界 在剂量上得到清晰的野边界 and eliminates concern about block transmission and excess dose to the contralateral breast Set up is fast and the steps involved are simple and few Advantages and limitations of this technique are presented PMID 8256000 PubMed indexed for MEDLINE 5 1 Int J Radiat Oncol Biol Phys 2000 Aug 1 48 1 139 46 Links Internal mammary node coverage an investigation of presently accepted techniques Arthur DW Arnfield MR Warwicke LA Morris MM Zwicker RD Department of Radiation Oncology Medical College of Virginia Hospitals of Virginia Commonwealth University Richmond VA USA dwarthur hsc vcu edu PURPOSE Recent publications have generated a renewed interest in regional nodal treatment to include the ipsilateral supraclavicular and internal mammary nodes IMN The purpose of this study is to evaluate three presently accepted treatment techniques for coverage of the intact breast and ipsilateral lymph node regions and to construct recommendations regarding the utilization of these techniques METHODS AND MATERIALS Anatomic data were obtained from five randomly selected patients with computerized tomography CT in treatment position Three patients presented with cancer of the left breast and two with cancer of the right Using the Pinnacle 3 D planning system normal tissue volumes of breast ipsilateral lung heart sternum and the IMN target were delineated for each patient Three accepted techniques used to treat ipsilateral breast internal mammary and supraclavicular nodes extended tangents 5 field partly wide tangents were configured and compared to a supraclavicular field matched to standard tangential fields A dosage of 50 Gy in 25 fractions was prescribed to the target volume Dose volume histograms DVH were generated and analyzed with regard to target volume coverage and lung heart volumes treated RESULTS All of the treatment techniques covering IMN include at least 10 more lung and heart volume than that covered by standard tangential fields The relative lung and heart volumes treated with each technique were consistent from p
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 高安市九年级上学期语文期中考试卷
- 二年级数学计算题专项练习集锦
- 脱硫废水零排放技术协议书(2篇)
- 高中技术学业水平测试试卷
- 南京工业大学浦江学院《食品标准与法规》2022-2023学年第一学期期末试卷
- 翰林国际(原曹妃甸科教城共享居住及配套)土地固化施工组织设计
- 多种多样的生态系统说课稿
- gkh说课稿第课时
- 《小数的性质》说课稿
- 租地合同范本(2篇)
- 【参考】华为腾讯职位管理0506
- 五年级英语上册Unit1Getupontime!教案陕旅版
- 风机安装工程质量通病及预防措施
- 三角形钢管悬挑斜撑脚手架计算书
- 文件和文件夹的基本操作教案
- 剪纸教学课件53489.ppt
- 旅游业与公共关系PPT课件
- 劳动法讲解PPT-定稿..完整版
- 彩色的翅膀_《彩色的翅膀》课堂实录
- 假如你爱我的正谱
- 铜芯聚氯乙烯绝缘聚氯乙烯护套控制电缆检测报告可修改
评论
0/150
提交评论