版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
储能产品全球主要市场法规及测试认证要求Since
150yearsTÜVSÜDstaystruetoitsfounding
principlesofprotectingpeople,environmentandpropertyagainsttheadverseeffectsoftechnology.TÜV
SÜDAG
|CORPORATE
PRESENTATION18-08-01
22,4
Billion
Revenue57Countries24.000+
Employees1000+
LocationsTÜVSÜD
MissionstatementTÜV
SÜDAG
|CORPORATE
PRESENTATION18-08-013REAL
ESTATEAND
INFRASTRUCTUREHEALTHCAREAND
MEDICALDEVICESCONSUMERPRODUCTS
AND
RETAILMANUFACTURINGMOBILITYENERGYCHEMICAL
ANDPROCESSDelivering
real
business
benefitsacross
industries+4
°-6°target
+2
°-4°target
450
+2
°target
408
ppm
380450430410390370350330310290270250230210190170150
criticalco²
concentration400to450ppm
Today
2005iceage
iceage
iceageiceageTÜV
SÜDAG
|
E-Mobility2018
18-08-014DevelopmentoftheglobalCO2
concentrationintheatmosphereGlobalCO²concentrationinthelast400.000yearsco²
concentrat
ion(parts
perm
i
l
l
ion
ppm)250.000200.000150.000100.00050.0000Historic
CO2
concentration
in
ppmyear400.000300.000350.000Real
Estate0
COTransport0
COPowerSupply0
COIndustry-90%
CO2by2050
(industrialized
countries
including
China!)18-08-015Whatdoesthe
Parisclimate
protectionagreement
really
mean?222•
Heating
,Cooling•
Ventilationheat/coldexchange
•Energystoragesystems•
Efficient
householdappliances•Insulations/
Isolations/
Hi-tecwindows•
Lightweight
materials•
Batteriesandfuelcells•
Powerelectronics•
Electricengines•
PV-/windpower•Geothermal-,hydro
power18-08-01
6Relevanttechnologydirectionstriggered
bythe
ParisagreementEnergyStorageSystemTÜV
SÜDAG
|
E-Mobility2018
18-08-017PVTheelectricvehicle
isa„system“–safetyalso
needsasystemapproach!WPT(BufferBattery)
ChargingdeviceBatterySmartControlEGridconnectionPEPlugTÜV
SÜDAG
|
E-Mobility2018
18-08-018„Plus
Energy
Houses“in
AustriaandGermany5%18%33%7%13%24%EnergysourceInvestments2017
(in
billionUS$)PV151Wind117Hydro85Gas32Coal61Nuclear17TÜV
SÜDAG
|
E-Mobility2018
18-08-019„Global
Investmentsintoelectricity
productioncapacities
PV
Wind
Hydroelectric
Gas
Coal
NuclearSector/AreaAdditionalInvestment(intrillion
US$)EnergyEfficiency23RenewableEnergysupply16Buildings5T&D,
Back-up&
BatteryStorage8CCS,
materialefficiencyimprovements&
nuclear1Fossilfuel&nuclearelectricitygeneration(avoidedinvestments)-25Total29•Meeting
the
2
°C
target
requires
investing
an
additional
US$
29
trillion
between
2015
and
2050•Thetotal
investmentcost
is
reduced
by
the
avoided
investments
in
the
upstreamsector
and
in
fossil-fuelled
power
generationSource:
IRENATÜV
SÜDAG
|
E-Mobility2018
18-08-0110Totalglobal
investementsneededtomeetthe2°C
Paristarget394030,127,325,820,414,2
15,116,3
17,09,311,610,26,24,76,67,7
7,6TÜV
SÜDAG
|
E-Mobility2018
18-08-0111RenewableenergyshareofgrosselectricityconsumptionGermany1990199520002002200420062008201020122014201620182020RenewableenergysharesofgrosselectricityconsumptioninGermany454035302520151050Share
in
percent23,633,03,4TÜV
SÜDAG
|
E-Mobility2018
18-08-0112Electricitystock
marketGermany:
Lowestelectricitypricessince
adecade!24-26€
MWh2018TÜV
SÜDAG
|
E-Mobility2018
18-08-0113Spot
MarketInstantdeliveryornext
daydeliverytypicallyonhourlybasisStock
MarketforElectricityIntradayVeryshorttermcontracts,
deliverywithin5
minutes,
availabilitycanbe
tradedFutureContractsLongtermcontractsfor
base
loadand
peakdemandNext
Day
FuturesDayahead
market
Marketcloses
12:00
Basedon
prognosesChangeofintradaytradingvs.longtermfutures@theelectricity
stock
market
in
GermanyElectricity
Price(mainlyforindustrycustomersandutilities,privatecontractsare
notyetconnectedtothesystem)Germany(Austria,
Norwayandothers)wentaheadin
renewableenergies•Thereisa
big
difference
ifthere
isa
transitionfrom
central
powerto
distributed
renewables•VScountriesextendingtheirsupplies
by
renewables.The
latter
need
storage
capacity
much
earlier!•Intypical
„
industrialized
country“grids
upto
50%
share
of
renewables
no
storage
is
needed!
(stillavailablefossil
reserve
plusconnectedgrids)•But:@shares
>50%to
over
80%
storage
is
increasingly
needed!
Simulation
study
Germany*:
@90%
renewable
energies
about220TWh/astorageis
needed!(outof700TWh/aconsumption).This
ratio
might
apply
similar
to
every
industrialized
countrycomingfromatransition!*ZSWand
DLRTÜV
SÜDAG
|
E-Mobility2018
18-08-0114TÜV
SÜDAG
|
E-Mobility2018
18-08-0115highenergystoragesystems•
pumpedhydro•
hydrogen-systems•
hydrogen-gas-caverns•
air-pressurestorage•
flow-batteries
•
P2G•
others...residentialstoragesystems•
Li-Ion-systems•
Lead-acid-systems•
others...•
Thermal-systems(water,
noelectricity)back-uppowersystems•
Li-Ion-systems•
hydrogen-systems•
flow-batteries•
others...highpowersystems•
Li-Ion-systems•
flywheels•
supercapacitors•
others...Whatkindofenergystoragesystemsare
needed?TÜV
SÜDAG
|
E-Mobility2018
18-08-0116•
10
kWhsystem,3
kWp•3500
US$•7
kWhsystem,
3
kWp•3000
US$AndTeslaeven
thinks
big:100
kWhsystem–25k
US$Isthere
a
market?38,000
pre-orders
afterthreedays!Elon
Muskchangedthepowerstoragemarket4
years
ago!Teslabatterysystem
Australia(7
MW/
729
MWh)TÜV
SÜDAG
|
E-Mobility2018
18-08-0117TÜV
SÜDAG
|
E-Mobility2018
18-08-0118Second
Life
Batteryproject
Lünen(40Smart
Electric
Batteries)•
Economicsuccessdepends
on
lifetime
performance–
10years
plus!•
Localenvironmental
conditions
must
bespecifiedandtestet–
inside/outside
operation•
Sytems
installed
inthe
house
have
morestabilconditions
butsaftety
requirements
and
proofofproductsafety
is
key
toinsurancecompanies–
fire
insurance!•Therearealmost
no
existing
safety
regulations
for
inhouse
installations
of
RESS•Serveralcountries
(e.g.
Japan,
Germany)
issued
guidelines
for
RESS•Standards
are
evolving
–
dynamic
environmentTÜV
SÜDAG
|
E-Mobility2018
18-08-0119Challengesof(residential)storagesystems:TÜV
SÜDAG
|
E-Mobility2018
18-08-0120(d)
Explosivegas
hazard.(e)Chemical
hazard.(a)
Electrical
hazard(c)
Fire
hazard.(f)
Mechanical
hazard.Possible
HazardsofBatteriesand
EnergyStorageSystem6mainhazardtypesassociatedwithbatteryenergy
storagesystems(b)
Energy
hazard.TÜV
SÜDAG
|
E-Mobility2018
18-08-0121Electromagnetic
compatibility(EMC)Certificationforrisk
mitigationFunctionalSafetyCommunication/Cyber
securitySafetyofInstallationProductSafetyRecyclingTransportationSafetyGridConnectionCodeMeetthe
following
Standards/
CodesMinimizerisks
of
ESSTÜV
SÜDAG
|
E-Mobility2018
18-08-0122(d)
Explosivegas
hazard.(e)Chemical
hazard.(a)
Electrical
hazard(c)
Fire
hazard.(f)
Mechanical
hazard.Possible
HazardsofBatteriesand
EnergyStorageSystem6mainhazardtypesassociatedwithbatteryenergy
storagesystems(b)
Energy
hazard.•eliminate
orminimize
risks–
Immunity
residential,
commercialand
light-industrial
environments
industrialenvironments–
Emission
residential,
commercialand
light-industrial
environments
industrialenvironments–Immunity
requirementsfor
functional
safetyTÜV
SÜDAG
|
E-Mobility2018
18-08-0123
eliminateorminimize
risks–
Powerquality–
Reactive/Activepowercontrol–Voltage/Frequencyregulation–
Islandingprotection–Voltageandfrequencyprotection–
DemandresponseMinimizetherisks
bytestingandcertification
GridConnectionElectromagneticcompatibility(EMC)•eliminate
orminimize
risks–Safety
lifecycle–Hardware
fault
behaviour–Softwarefault
avoidance
andfault
control–Safety-related
clauses
ofthe
user
manualFunctionalSafetyStoragesystems
mustcomplyinthe
EuropeanUnionwiththeCE
marking
regulationandrelateddirectives,inNorth
Americawiththe
listingrequirementsandthenationalcodesWiththeCE-markorlisting
mark,the
manufacturer,hisauthorizedrepresentativeorthe
importerstatesthatthe
productmeetsthelegal
requirements.Helpfulforthe
manufacturersarethe
harmonizedproductstandards.
Followingthisstandards,complianceis
presumed.(e.g.
IEC63056)Forthe
USAa
productstandardisavailable(UL9540),butfurther
requirementsneedto
be
metLegal
requirements!
are
defined
bythe
legislation,
e.g.
European
Commission
or
USauthorities
and
regional/local
requirements
likefrom“FireSafety
Authorites”
and
Address
products
produced
inorimportedtothe
marketsthat
cancausethreadstohealth
and
environmental.TÜV
SÜDAG
|
E-Mobility2018
18-08-0124Step
1:Findtheapplicable
directives,
standards
and
regulationsStep2:Determinetheapplicable
conformity
assessment
moduleStep3:Carryoutariskassessment,
define
measures
based
on
harmonizedstandards(FMEA,SIL,
FUSI…)Step4:Implementthe
measures
defined
at
the
risk
assessmentStep5:
Createthetechnicalfile
(TF)Step6:Declareconformity
and
do
the
CE-marking/
apply
for
UL
9540
complianceTÜV
SÜDAG
|
E-Mobility2018
18-08-0125Globalmarketaccess,
recommendedstrategy•thegeneraldescriptionofthe
product;•generalarrangementdrawing•the
listofstandardsandessential
requirementsthatare
met•the
risk(matrix,
FMEA)assessmentto
identify
healthand
safety
requirements•thedesignandfabrication
drawings•detailedtechnical
informationon
keyaspectsofthe
product;•reportingofcalculations
andtests•descriptionofcontrol
philosophy/logicwiring,circuitdiagrams,
partslist•certificatesandtest
reports•manualsfor
installation,
user,
maintenance,•forseries
production,the
internal
rulesthatareadhered
to
ensure
accordancewith
the
Directive(s)•specifications,datasheetsforsub-assembliesandtheir
DoC`s•qualitycontrol&commissioning
procedures•DeclarationofConformity
(DoC)TÜV
SÜDAG
|
E-Mobility2018
18-08-0126TheTFincludesthefollowingreportsanddocuments:TCAspectPublishedStandardsTC8SystemsaspectsofelectricalenergysupplyIECTS62786
Distributedenergy
resources
connectionwiththegridIEC62934Grid
integrationofrenewable
energygenerationTC21SafetyofBatterySystemIEC62619Safetyrequirementsforsecondary
lithiumcellsand
batteries,for
use
in
industrial
applicationsTC22TC82SafetyofPCSIEC62477-1Safety
requirements
for
power
electronic
converter
systems
and
equipment
-Part
1:
GeneralIEC62109-1
Safety
of
power
converters
for
use
in
photovoltaic
power
systems
-
Part
1:
General
requirementsIEC62109-2Safety
of
power
converters
for
use
in
photovoltaic
power
systems
-Part2:Particular
requirementsTC64SafetyofLowvoltageelectricalinstallationsIEC60364-4-XX
series
Part4-XX:Protection
for
safety-
Protection
against
electric
shock;
thermal
effects;
overcurrentIEC60364-5-XX
series
Part5-XX:Selection
and
erection
of
electrical
equipment
-Wiring
systems;Isolation,
switching
and
control;Earthing
arrangements
andprotectiveconductorsIEC60364-6
Part6:VerificationSC65AFunctionalsafetyIEC61508
Functionalsafetyofelectrical/electronic/programmable
electronicsafety-relatedsystemsTC77EMCIEC61000-6-x
series;-1
Immunitystandardforresidential,commercialand
light-industrial
environments;
environments-3
Emissionstandardforresidential,commercialand
light-industrialenvironments;environments-7
Immunityrequirementsforfunctionalsafety
inindustrial
locations-2
Immunitystandardforindustrial-4
EmissionstandardforindustrialTC120ElectricalEnergyStorage
(EES)SystemsIEC62933-1:2018Electrical
energy
storage
(EES)systems-
Part
1:
VocabularyIEC62933-2-1:2017Electrical
energy
storage
(EES)systems
-
Part
2-1:
Unit
parameters
and
testing
methods
-
General
specificationIEC
TS62933-4-1:2017Electrical
energy
storage
(EES)systems-
Part
4-1:
Guidance
on
environmental
issues
-General
specificationIEC
TS62933-5-1:2017Electrical
energy
storage
(EES)systems-
Part
5-1:Safety
considerations
for
grid-integrated
EES
systems
-General
specificationTÜV
SÜDAG
|
E-Mobility2018
18-08-0127
IECTechnicalcommitteesforBattery
EnergyStorageSystemIECschemeStandardsforBatteryEnergy
Storage
SystemAspectPublishedStandardsSafety
and
InstallationVDE-AR-E2510-50Stationary
battery
energy
storage
systems
with
lithium
batteries-
SafetyVDE-AR-E2510-2Stationary
electrical
energy
storage
systems
intended
for
connection
to
the
low
voltage
gridSafety
of
Battery
SystemIEC62619Safety
requirements
for
secondary
lithium
cells
and
batteries,for
use
in
industrial
applicationsVDE-AR-E2510-50Stationary
battery
energy
storage
systems
with
lithium
batteries-
SafetySafety
of
PCSIEC62477-1Safety
requirements
for
power
electronic
converter
systemsandequipment-
Part
1:
GeneralIEC62109-1Safetyofpowerconvertersforuseinphotovoltaic
powersystems
-
Part
1:
General
requirementsIEC62109-2Safety
of
power
converters
foruseinphotovoltaic
powersystems
-
Part
2:
Particular
requirementssafetyofLowvoltageelectricalinstallationsIEC60364-4-XXseriesIEC60364-5-XXseriesIEC60364-6Grid
IntegrationVDE-AR-E2510-2Stationary
electrical
energy
storage
systems
intended
for
connection
to
the
low
voltage
gridVDE-AR-N4105Technical
requirements
for
the
connection
to
and
parallel
operation
with
low-voltage
distribution
networksBDEW
Guideline
for
generating
plants’
connection
to
and
parallel
operation
with
the
medium-voltage
networkEMCIEC61000-6-xseriesTransportationUN38.3United
Nations
Recommendations
On
The
Transport
Of
Dangerous
GoodsADR
EuropeanConventiononthe
InternationalCarriageofDangerousGoodsby
RoadFunctional
safetyVDE-AR-E2510-50Stationary
battery
energy
storage
systems
with
lithium
batteries-
SafetyIEC61508Functional
safety
of
electrical/electronic/programmable
electronic
safety-related
systemsTÜV
SÜDAG
|
E-Mobility2018
18-08-0128RESSCompliantStandardsofGermanyAspectPublishedStandardsSafety
and
InstallationAS
DR5139(Draft)
Electrical
installations-Safety
of
battery
systems
for
use
with
power
conversion
equipmentSafety
of
Battery
SystemIEC62619Safety
requirements
for
secondary
lithium
cells
and
batteries,for
use
in
industrial
applicationsSafety
of
PCSIEC62109-1Safetyofpowerconvertersforuseinphotovoltaic
powersystems
-
Part
1:
General
requirementsIEC62109-2Safety
of
power
converters
foruseinphotovoltaic
powersystems
-
Part
2:
Particular
requirementsAS62040.1.1Uninterruptible
power
systems
(UPS)
Part
1.1:GeneralandsafetyrequirementforUPS
used
in
operatoraccess
areassafetyofLowvoltageelectricalinstallationsIEC60364-4-XXseriesIEC60364-5-XXseriesIEC60364-6Grid
IntegrationAS/NZS4777.1Grid
connection
of
energy
systems
via
inverters–Part
1:
Installation
requirementsAS/NZS4777.2Grid
connection
of
energy
systems
via
inverters
Inverter
requirementsAS/NZS4755.3.5Demand
response
capabilities
and
supporting
technologies
for
electrical
products-
Interaction
of
demand
response
enabling
devicesand
electrical
products-Operati
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025届河北省唐山市高三下学期第一次模拟考试政治试题(原卷版+解析版)
- 2025年空调箱总成合作协议书
- 5.5显微镜和望远镜 说课稿 2025年初中人教版物理八年级上册
- 晚上打瞌睡检讨书
- 关于志愿者的活动方案
- 证监局回复函立案
- 《商业插画创意与表现》课件-【5】商业插画的材料与表现技法
- 一体化污水处理设备采购安装及运维 投标方案(技术方案)
- 三农村基层教育资源配置与优化方案
- 教育行业教师培训与成长计划
- FZ∕T 01085-2018 粘合衬剥离强力试验方法
- 白龙江引水工程环境影响报告书(公示版)
- 《短视频拍摄与制作》课件-3短视频中期拍摄
- 浏阳烟花术语大全
- 五星级酒店前厅管理常用表格
- 居民心理健康知识讲座课件
- 《养老护理员》-课件:老年人安全防范及相关知识
- 2024年英语专业四级考试真题及详细答案
- 成语故事叶公好龙
- MHT:中小学生心理健康检测(含量表与评分说明)
- 制度修订培训课件
评论
0/150
提交评论