版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
02-10
251010-
SECTION251010
ADVANCEDUTILITYMETERINGSYSTEM
SPECWRITERNOTES:
Deletebetween//____//ifnotapplicabletoproject.Alsodeleteanyotheritemorparagraphnotapplicableinthesectionandrenumbertheparagraphs.Thisspecificationsectionappliestoandshallbeincludedwithallworktobeperformedunderthe22,23,26,32,and33DivisionsoftheMasterConstructionSpecifications.TheSectionisgeneralinnature,andshouldbeeditedtofiteachproject.
Providescheduleforeachflowmeterlistingflowmetertype,fluidtypeandcharacteristics,temperatureandpressureoffluid,flowrange(maximumandminimumflows),maximumpressureloss,minimummeteraccuracy,Englishandmetricmeasurementunits.
TheVAhasinplaceaCorporate-WideAdvancedUtilityMeteringDatabase,whichallowstheVAtoautomaticallyquerysomeofitsfacilitiesfortheirenergyandwaterusage.Thisspecificationrolls-outAdvancedUtilityMeteringSystems(AUMS)toallofitsfacilities.EachfacilityshallincludeanAUMS,periodicallytransmittinginformationinaformatcompatiblewiththeexistingVACorporate-WideAdvancedUtilityMeteringDatabase.
Thisspecificationdefinesthestructurefortheroll-outoftheAUMSs:eachVISNorVAMCshallbeprovided(bythissection,ifnotalreadyin-place)aSiteDataAggregationDevice(aPCworkstationorserver);communicationsbetweenthisSiteDataAggregationDeviceandtheVA’sCorporate-WideAdvancedUtilityMeteringDatabaseshallbeviaperiodicTCP/IPcommunications;communicationsbetweentheSiteWideAggregationDeviceandthefacility’smetersshallbeviaEthernetcabling(separatefromtheITsystem’sandtheHVACcontrolsystem’scabling),andwireless;andmetersofthefacility’senergyflowsandwaterflows.
Communications(especiallyTCP/IP)shallcomplywithNIST-recommendedsecurityprotocols.
CommunicationsbetweenmetersandtheSiteDataAggregationDeviceshallallowforreal-timeandhigh-samplingfrequencyautomaticmonitoringofenergyflowsthroughoutandwithineachfacilityaswellasless-frequentintervalor“billing”metering.TheAUMSshallincludecapacityforfutureautomaticcontrol:dispatchofloadsdependingonthresholdsbeingreached,alarmnoticesauto-sentundervariousconditions,andthelike.TheAUMSshallincludevariouslevelsofoperatorinterfaceandaccess,andshallallowforcustomizableviewportsasrequiredbytheUser.
Thisspecificationincludesmetersandcommunicationssystemswhichmaynotberelevanttotheindividualproject.Thespecifyingengineershallsurveythesiteandexaminephysicalconditionsandconstraintsrelativethefacilitybeingdesigned.ThespecifyingengineershallcoordinatethemeteringandcommunicationsscopewiththefacilityengineerandtheResidentEngineer.ThespecifyingengineershallonlytheneditthisspecificationtoincludeonlythosefeaturesrelevanttoandrequiredbytheAUMS.
Separatecablingorradiotransmission(RF)fromthemeterstotheSiteDataAggregationDeviceisrequired.Thecommunicationstransmissionshallnotberunonthefacility’sITnetwork.Ifthemetersareexistingandpartofthefacility’sdirectdigitalcontrolsystem,andifthoseexistingmetersaresufficienttothisSection’smission,theinformationmaythenbetransmittedoverthefacility’sdirectdigitalcontrolsystemnetworktothefacility’sECC,andfromtheretotheAUMS.
Showondrawingsallcommunicationscablingrouting,meterandtriminstallationdetailsandlocations,aswellasdescribingmethodsandmeanslimitationsfortheimplementationoftheAUMS.
Thespecifyingengineershallhavecompleteknowledgeofthespaceandcablepathways(i.e.equipmentrooms,TCs,conduits,wireways,etc.)oftheFacility.ThespecifyingengineershallataminimumdesignandinstalltheSystemusingthePathwayDesignHandbookH-088C3,TIA/EIATelecommunicationsBuildingWiringStandards,andVA’sFacilityChiefofInformationTechnologies(IT)instructions,asapprovedinwritingbytheVA.
Designanewsystemconformingtocurrentandaccepteddigitalindustrial/commercialcableandRFdistributionstandards.ThedistributioncableinstallationshallbefullycoordinatedwiththeVApriortothestartofinstallation.
Specifycableinthissystem(i.e.backbone,outsideplant,insideplant,andstationcabling)toconformtothisSectionandtoacceptedindustryandOEMstandardswithregardstosize,colorcode,andinsulation.Thepairtwistsofanypairshallnotbeexactlythesameasanyotherpairwithinanyunitorsub-unitofcablesthatarebundledintwenty-five(25)pairsorless.
TheSystemcablesshallbeprotectedconduit.ThespecifyingengineershallincludeSection260533inthespecificationsforthework.SomeareasofthisFacilitymaybeconsidered“plenum”.Ifanyofwireandcableusedinsupportoftheinstallationinthoseareasisnotinconduit(thisguidancedoesnotgrantrelieffromtheprotection):thenthecablingmustcomplywithnationalandrelevantcodespertainingtoplenumenvironments.ReviewtheVA’scableandwirerequirementswiththeVApriortoinstallationtoconfirmthetypeofenvironmentpresentateachlocation.
Designoutside-andinside-plantcablesthatfurnishthenumberofcablepairsrequiredinaccordancewiththeSystemrequirementsdescribedherein.FullycoordinateandobtainapprovalofthedesignwiththeoriginalequipmentmanufacturerandtheVApriortoinstallation.
Additionofadvancedmetersshallinnowayaffectanyexistingutilitymeteroritscomponents.
Thismetershallbeusedassupplementalinformation.
Knowthatmetersinstalledadjacentotherutilitymeterswillnotreadexactlythesame.
Thisdifferenceisduetothedifferentturn-downratios,calibrationstodifferentCT’s,andalsoduetodifferingaccuraciesofthemeters.
ExistingmetersalreadyinplacemayservethemissionofthisSection,providedthattheycomplywiththecommunicationsandaccuracyrequirementsofthisSection.Confirmthisre-usewiththeVA’sFacilityEngineerandREO.
Unlesstheconstructionisonagreenfield,mostoftheutilitiesmeteredbythisSectionarefundamentaltotheoperationofthefacility.Chooseinsertion-typemetersandusehot-tapsintoactivepipingsystemsandothermeanstoallowformeterinsertionintotheutilitydistributionsystemswithoutforcingoutagesofthosesystems.
MetermaintenanceisanimportantconcernfortheVA:wherefeasible,specifymeterswithnomovingparts,sominimizingmaintenanceofmechanicalcomponentsoverthelifeofthemeter.
PART1-ENERAL
1.1 DESCRIPTION
A. ThisSectionincludesthefollowingfortheadvancedmeteringofthesystemsofthefacility.Themeteredsystemsincludetheelectricalpower,naturalgasdistribution,fuelgasandfueloil,steam,steamcondensate,chilledwater,heatingwater,domesticwater,recoveredwaterandmakeupwatersystems.ThemeteringsystemsineachfacilityarepartofaCorporate-Wideutilitymeteringsystem,renderingtheVAaccurateandautomatedmeteringofitsfacilities’energyandwaterflows.Meteringsystemsarecomprisedof:
1. PC-basedworkstation(s)orserver(s)andsoftware.
2. Communicationnetworkandinterfacemodulesfor//RS-232,RS-485,ModbusTCP/IP,IEEE
802.3//datatransmissionprotocols.
3. Electricmeters.
4. Volumetricflowmeters,temperaturesensorsandpressuretransducers.
5. Massflowmeters.
1.2 RELATEDWORK
A. //Section130541,SEISMICRESTRAINTREQUIREMENTSFORNON-STRUCTURALCOMPONENTS:Requirementsforseismicrestraintofnonstructuralcomponents.//
B. Section220519MetersandGagesforPlumbingPiping:metersandgages.
C. Section223300ElectricDomesticWaterHeaters:referencesmeters.
D. Section223400Fuel-FiredDomesticWaterHeaters:referencesmeters.
E. Section223500DomesticWaterHeaterExchangers:referencesmeters.
F. Section230511,COMMONWORKRESULTSFORHVACANDSTEAMGENERATION:Generalmechanicalrequirements,commontomorethanonesectioninmechanical.
G. Section230911,INSTRUMENTATIONANDCONTROLFORBOILERPLANT:Flowmeters
H. Section230923,DIRECT-DIGITALCONTROLSYSTEMFORHVAC:Flowmetersandcommunications
I. Section260511,REQUIREMENTSFORELECTRICALINSTALLATIONS:GeneralelectricalrequirementsanditemsthatarecommontomorethanonesectionofDivision26.
J. Section260521,LOW-VOLTAGEELECTRICALPOWERCONDUCTORSANDCABLES(600VOLTSANDBELOW):Lowvoltagecable.
K. Section260526,GROUNDINGANDBONDINGFORELECTRICALSYSTEMS:Requirementsforpersonnelsafetyandtoprovidealowimpedancepathforpossiblegroundfaultcurrents.
L. Section260533,RACEWAYANDBOXESFORELECTRICALSYSTEMS:Conduits.
M. Section261116,SECONDARYUNITSUBSTATIONS:Unitsecondarysubstation.
N. Section261300,MEDIUM-VOLTAGESWITCHGEAR:Highvoltageswitchgear.
O. Section261841,MEDIUM-VOLTAGESWITCHES:Highvoltageswitches.
p. Section262300,LOW-VOLTAGESWITCHGEAR:Secondarydistributionswitchgear.
Q. Section262411,DISTRIBUTIONSWITCHBOARDS:Secondarydistributionswitchboards.
R. Section262419,MOTOR-CONTROLCENTERS:Motorcontrolassemblies.
S. Section328400PlantingIrrigation:referencesmeters.
T. Section331000WaterUtilities:referencesmeters.
U. Section335100NaturalGasDistribution:referencesmeters.
V. Section336300SteamEnergyDistribution:referencesmeters.
1.3 definitions
A. AMR:Automaticmeterreadingisthetechnologyofautomaticallycollectingconsumption,diagnostic,andstatusdatafromwaterandenergymeteringdevices(water,gas,electric,steam)andtransferringthatdatatoacentraldatabaseforbilling,troubleshooting,andanalyzing.
B. AUMS:AdvancedUtilityMeteringSystem:thesystemdescribedbythisSection.
C BACnet:BACnetisaDataCommunicationsProtocolforBuildingAutomationandControlNetworks.ItisdefinedbyASHRAE/ANSIStandard135(ISO16484-5)standardprotocol.
D. DataOverCableServiceInterfaceSpecification(DOCSIS):aninternationalstandarddefiningcommunicationsandoperationsupportinterfacerequirementsforadataovercablesystem,bytheCableTelevisionLaboratories,Inc.consortium
E. DataHead(onmeters):convertsanalogandpulsesignalstodigitalsignalsfortransmissiontotheSiteDataAggregationDevice.Alsoprovidesforlimitedstorageofthedigitalsignals.
F. DeviceAccuracy:accuracyinthissectionisbasedonactualflow,notfullscaleorfullrange.Deviceaccuracymeasurestheconversionofflowinformationtoanalogorpulsesignals.
G. Ethernet:Localareanetwork,basedonIEEE
802.3standards.
H. Firmware:Software(programsordata)thathasbeenwrittenontoread-onlymemory(ROM).Firmwareisacombinationofsoftwareandhardware.StoragemediawithROMsthathavedataorprogramsrecordedonthemarefirmware.
I. Gateway:Bi-directionalprotocoltranslatorconnectingcontrolsystemsthatusedifferentcommunicationprotocols.
J. GB:gigabyte.Whenusedtodescribedatastorage,"GB"represents1024megabytes.
K. HTML:Hypertextmarkuplanguage.
L. I/O:Input/output.
M. KB:Shortforkilobyte.Whenusedtodescribedatastorage,"KB"represents1024bytes.
N. KYPulse:Atermusedbythemeteringindustrytodescribeamethodofmeasuringconsumptionofelectricitythatisbasedonarelaychangingstatusinresponsetotherotationofthediskinthemeter.
O. LAN:Localareanetwork.Sometimespluralas"LANs."
P. LCD:Liquidcrystaldisplay.
Q. LonMark:AnassociationcomprisingofsuppliersandinstallersofLonTalkproducts.TheAssociationprovidesguidelinesfortheimplementationoftheLonTalkprotocoltoensureinteroperabilitythroughStandardimplementation.
R. LonTalk:AnopenstandardprotocoldevelopedbytheEchelonCorporationthatusesa“NeuronChip”forcommunication.
S. LonWorks:NetworktechnologydevelopedbytheEchelonCorporation.
T. LowVoltage:AsdefinedinNFPA
70forcircuitsandequipmentoperatingatlessthat50
Vorremote-control,signalingandpower-limitedcircuits.
U. MB:megabyte.Whenusedtodescribedatastorage,"MB"represents1024kilobytes.
V. Mbps:Megabytespersecond,equalto8megabitspersecond
W. ModbusTCP/IP:Anopenprotocolforexchangeofprocessdata.
X. Monitoring:Acquisition,processing,communication,anddisplayofequipmentstatusdata,meteredelectricalparametervalues,powerqualityevaluationdata,eventandalarmsignals,tabulatedreports,andeventlogs.
Y. OTDR:OpticalTimeDomainReflectometer.Atestinstrumentthatanalyzesthelightlossinanopticalfiber.Usedtofindfaults,splicesandbendsintheline,itworksbysendingoutalightpulseandmeasuringitsreflection.Suchdevicescanmeasurefiberlinesthatarelongerthan150miles
Z. PC:Personalcomputer
AA.PICS,ProtocolImplementationConformanceStatement:AwrittendocumentthatidentifiestheparticularoptionsspecifiedbyBACnetthatareimplementedinadevice.
BB.REO:ResidentEngineerOffice:theVAofficeadministeringtheconstructioncontract.
CC.ReportingAccuracy:thisistheroot-mean-squaresumofallofthemeteringdevices’inaccuracies:measurementinaccuracy,mechanicalinaccuracy,analog-to-digitalorpulseintegrationinaccuracy,etc.,uptothemeter’sdatahead.
DD.rms:Root-mean-squarevalueofalternatingvoltage,whichisthesquarerootofthemeanvalueofthesquareofthevoltagevaluesduringacompletecycle.
EE.Router:Adevicethatconnectstwoormorenetworksatthenetworklayer.
FF.RS-232:ATelecommunicationsIndustryAssociationstandardforasynchronousserialdatacommunicationsbetweenterminaldevices.
GG.RS-485:ATelecommunicationsIndustryAssociationstandardformultipointcommunicationsusingtwotwisted-pairs.
HH.TB:terrabyte.Whenusedtodescribedatastorage,"TB"represents1024gigabytes.
II.TCP/IP:Transportcontrolprotocol/internetprotocol.
JJ.Turn-down:themaximumflowdividedbytheminimumflowthroughameter;usedalongwithaccuracyrequirements.Forexample,ametershallbeaccuratetowithin2%ofactualflowwiththroughouta20:1turndown
KK.THD:Totalharmonicdistortion.
LL.UPS:Uninterruptiblepowersupply;usedbothinsingularandpluralcontext.
MM.UTP:Unshieldedtwistedpaircabling,usedtolimitcrosstalkandelectromagneticinterferencefromtheenvironment
NN.WAN:Wideareanetwork.
1.4 qualityassurance
A. InstallerQualifications:Manufacturer'sauthorizedrepresentativewhoistrainedandapprovedforinstallationofunitsrequiredforthisProject.
B. ManufacturerQualifications:AfirmexperiencedatleastthreeyearsinmanufacturingandinstallingpowermonitoringandcontrolequipmentsimilartothatindicatedforthisProjectandwitharecordofsuccessfulin-serviceperformance.
C. ElectricalComponents,Devices,andAccessories:ListedandlabeledasdefinedinNFPA
70,Article
100,byatestingagency,andmarkedforintendeduse.
D. SystemModifications:MakerecommendationsforsystemmodificationinwritingtotheVA.NosystemmodificationsshallbemadewithoutpriorwrittenapprovaloftheVA.AnymodificationsmadetothesystemshallbeincorporatedintotheOperationsandMaintenanceInstructions,andotherdocumentationaffected.ProvidetotheVAsoftwareupdatesforallsoftwarefurnishedunderthisspecificationduringthiscontract’sconstructionandverificationperiodsandforthefirsttwoyearsaftergovernmentacceptance.Allupdatedsoftwareshallbeverifiedaspartofthiscontract.
1.5 performance
A. Theadvancedutilitymeteringsystemshallconformtothefollowing:
1. SiteDataAggregationDeviceGraphicDisplay:Thesystemshalldisplayupto4graphicsonasinglescreenwithaminimumof(20)dynamicpointspergraphic.Allcurrentdatashallbedisplayedwithin(10)secondsoftherequest.
2. SiteDataAggregationDeviceGraphicRefresh:Thesystemshallupdatealldynamicpointswithcurrentdatawithintenseconds.Datarefreshshallbeautomatic,withoutoperatorintervention.
3. MeterScan:Allchangesofmeteredvaluesshallbetransmittedoverthehigh-speednetworksuchthatanydatausedordisplayedatacontrollerorSiteDataAggregationDevicewillbecurrent,withinthepriortenseconds.
4. AlarmResponseTime:Themaximumtimefromwhenmetergoesintoalarmtowhenitisannunciatedattheworkstationshallnotexceedtenseconds.
5. ReportingAccuracy:Listedbelowareminimumacceptablereportingaccuraciesforallvalueswithinthebelowminimumturn-downenvelopereportedbythemeters:
MeasuredVariable
UnitsMeasured
MinimumTurn-DownofMeter
ReportingAccuracy(Note1)
Electricity
V,A,W,etc.
n/a
±0.5%ofmeasuredvalue
NaturalGas
l/s(CFH)
10:1
±2%
LiquefiedPetroleumGas
l/s(CFH)
10:1
±2%
Steam
kW(MBH)
20:1
±2%
Condensate
kW(MBH)
20:1
±2%
DomesticWaterflow
l/s(GPH)
20:1
±2%
ReclaimedWaterflow
l/s(GPH)
20:1
±2%
Make-upWatertoBoilersflow
l/s(GPH)
10:1
±2%
Make-upWatertoCoolingTowersflow
l/s(GPH)
10:1
±2%
No.2HeatingOil
l/s(GPH)
10:1
±2%
No.6HeatingOil
l/s(GPH)
10:1
±2%
HeatingWater
kW(MBH)
20:1
±2%
ChilledWater
kW(MBH)
20:1
±2%
OutsideAirTemperature
°C(°F)
n/a
±2%
OutsideAirRelativeHumidity
%rh
n/a
±2.5%
Table1.5:MeterPerformanceCriteria
TableNotes:
Thistableshowsreportingaccuracy,notmerelythemeter’saccuracy.Reportingaccuracyincludesmeteraccuracyanddataconversionaccuracy.SeeArticle1.3inthisSectionfordefinition.Accuracyisshownagainstthemeasuredvalue,notagainstthefullrangeofthemeter.
l/s:literpersecond
CFH:cubicfeetperhour
kW:kilowatt
MBH:1000’sBritishThermalUnitsperhour
GPH:gallonsperhour
1.6 WARRANTY
A. LaborandmaterialsforadvancedutilitymeteringsystemsshallbewarrantedforaperiodasspecifiedunderWarrantyinFARclause52.246-21.
B. Advanceutilitymeteringsystemfailuresduringthewarrantyperiodshallbeadjusted,repaired,orreplacedatnocostorreductioninservicetotheowner.Thesystemincludesallcomputerequipment,transmissionequipment,andallsensorsandmeteringdevices.
1.7 submittals
A. ProductData:foreachtypeofproductindicated,AttachcopiesofapprovedProductDatasubmittalsforproducts(suchasflowmeters,temperaturesensorsandpressuretransmitters,switchboardsandswitchgear)thatdescribeadvanceutilitymeteringfeaturestoillustratecoordinationamongrelatedequipmentandutilitymeteringandcontrol.
B. ShopDrawings:includeplans,elevations,sections,details,andattachmentstootherwork.
1. OutlineDrawings:Indicatearrangementofmeters,componentsandclearanceandaccessrequirements.Clearlyidentifysystemcomponents,internalconnections,andallfieldconnections.
2. BlockDiagram:ShowinterconnectionsbetweencomponentsspecifiedinthisSectionanddevicesfurnishedwithpowerdistributionsystemcomponents.Indicatedatacommunicationpathsandidentifynetworks,databuses,datagateways,concentrators,andotherdevicestobeused.Describecharacteristicsofnetworkandotherdatacommunicationlines.
3. Detailequipmentassembliesandindicatedimensions,weights,loads,requiredclearances,methodoffieldassembly,components,andlocationandsizeofeachfieldconnection.
4. WiringDiagrams:Power,signal,andcommunicationswiring.Coordinatenomenclatureandpresentationwithablockdiagram.Showallcommunicationsnetworkcomponentsandincludeacommunicationssingle-linediagramindicatingdeviceinterconnectionandaddressinginformationforallsystemdevices.Identifyterminalblocksusedforinterconnectionsandwiretypetobeused.
5. UPSsizingcalculationsforworkstation.
C. SoftwareandFirmwareOperationalDocumentation:
1. Self-studyguidedescribingtheprocessforsettingequipment'snetworkaddress;settingOwner'soptions;procedurestoensuredataaccessfromanyPConthenetwork,usingastandardWebbrowser;andrecommendedfirewallsetup.
2. Softwareoperatingandupgrademanuals.
3. SoftwareBackup:Onacompactdisc,completewithOwner-selectedoptions.
4. Deviceaddresslistandthesetpointofeachdeviceandoperatoroption,assetinapplicationssoftware.
5. Graphicfileandprintoutofgraphicscreensandrelatedicons,withlegend.
6. "Quick-Start"guidetodescribeasimple,three-stepcommissioningprocessforsettingtheequipment’sEthernetaddress,andensuringtrouble-freedataaccessfromanyPConthenetwork,usingastandardwebbrowser.
D. SoftwareUpgradeKit:ForOwnertouseinmodifyingsoftwaretosuitfutureutilitymeteringsystemrevisions.
E. FirmwareUpgradeKit:ForOwnertouseinmodifyingfirmwaretosuitfuturepowersystemrevisionsoradvancedutilitymeteringsystemrevisions.Firmwareupdates,andnecessarysoftwaretoolsforfirmwareupdates,shallbedownloadablefromtheinternet.VAshallbeabletoupdatefirmware,inequipment,withoutremovingdevicefromtheequipment.VAshallbecapableofupdatingfirmwareovertheutilitymeteringcommunicationnetworkorthroughlocalcommunicationportsonthedevice.
F. Softwarelicensesandupgradesrequiredbyandinstalledforoperatingandprogrammingdigitalandanalogdevices.
G. QualificationData:Forinstallerandmanufacturer
H. OtherInformationalSubmittals:
1. Systeminstallationandsetupguides,withdataformstoplanandrecordoptionsandsetupdecisions.
I. ReviseandupdatetheContractDrawingstoincludedetailsofthesystemdesign.Drawingsshallbeon17by11inchessheets.DetailstobeshownontheDesignDrawinginclude:
1. Detailsonlogicalstructureofthenetwork.Thisincludeslogicallocationofallnetworkhardware.
2. Manufacturerandmodelnumberforeachpieceofcomputerandnetworkhardware.
3. Physicallocationforeachpieceofnetworkorcomputerhardware.
4. PhysicalroutingofLANcabling.
5. Physicalandqualitativedescriptionsofconnectivities.
1.8 CLOSEOUTSUBMITTALS
A. OperationandMaintenanceData:Foradvancedutilitymeteringsystemcomponentsandmeters,toincludeinemergency,operation,andmaintenancemanuals.Includethefollowing:
1. Operatingandapplicationssoftwaredocumentation.
2. Softwarelicenses.
3. Softwareserviceagreement.
4. PCinstallationandoperatingdocumentation,manuals,andsoftwareforthePCandallinstalledperipherals.Softwareshallincludesystemrestore,emergencybootcompactdisks,anddriversforallinstalledhardware.ProvideseparatelyforeachPC.
5. Hardcopiesofmanufacturer'sspecificationsheets,operatingspecifications,designguides,user'sguidesforsoftwareandhardware,andPDFfilesonCD-ROMofthehard-copysubmittal.
6. Inadditiontothecopiesrequiredby010000,provide5boundpapercopiesoftheOperationandMaintenanceDataandtwocompactdisks(CD),withallInstructionsasAcrobatPDFfiles.ThepdffilesshallidenticaltothepapercopiesandshallAcrobatnavigationtoolsincludingBookmarksforeachChapter.
7. TheadvancedutilitymeteringsystemOperationandMaintenanceInstructionsshallinclude:
a. ProceduresfortheAUMSsystemstart-up,operationandshut-down.
b. FinalAs-Builtdrawings,includingactualLANcablingroutingshownonarchitecturalbackgrounds.
1) IPaddress(es)asapplicableforeachpieceofnetworkhardware.
2) IPaddressforeachcomputerserver,workstationandnetworkedprinter.
3) Networkidentifier(name)foreachprinter,computerserverandcomputerworkstation.
4) CEA-709.1Baddress(domain,subnet,nodeaddress)foreachCEA-709.1BTP/FT-10toIPRouter.
c. Routinemaintenancechecklist,renderedinaMicrosoftExcelformat.Theroutinemaintenancechecklistshallbearrangedinacolumnarformat.Thefirstcolumnshalllistallinstalleddevices,thesecondcolumnshalllisteachdevice’snodeidentifier/address,thethirdcolumnshalldescribeeachdevice’sphysicallocation,thefourthcolumnshallstatethemaintenanceactivityorstatenomaintenancerequired,thefifthcolumnshallstatethefrequencyofthemaintenanceactivity,frequencyofcalibrationandthesixthcolumnforadditionalcommentsorreference.
d. Qualifiedserviceorganizationlist.
e. InadditiontotherequirementsinSection013323,thesubmittalshallincludemanufacturerInstallationRequirements.
f. Includecompleteinstructionsforcalibrationofeachmetertypeandmodel.
g. Start-UpandStart-UpTestingReport.
h. Performanceverificationtestproceduresandreports.
i. PreventiveMaintenanceWorkPlan.
j. Inadditiontofactorytrainedmanufacturers'representativesrequirementsin010000,providesignedletterbyfactorytrainedmanufacturers'representativesstatingthatthesystemandcomponentsareinstalledinstrictaccordancewiththemanufacturers’recommendations.
B. Fieldquality-controltestreports.
1.9 LICENSINGAGREEMENT
A. Licensesprocuredaspartofthisworkbecomethepropertyofthegovernmentuponacceptanceofthework.Licensesshallhavenoexpiration.
B. TechnicalSupport:BeginningwithGovernmentAcceptance,providesoftwaresupportfor//one//two////Insertnumber//years.
C. UpgradeService:UpdatesoftwaretolatestversionatProjectcompletion.InstallandprogramsoftwareupgradesthatbecomeavailablewithintwoyearsfromdateofGovernmentAcceptance.Upgradingsoftwareshallincludetheoperatingsystems.Upgradeshallincludeneworrevisedlicensesforuseofsoftware.
1. Provide30-daynoticetoOwnertoallowschedulingandaccesstosystemandtoallowOwnertoupgradecomputerequipmentifnecessary.
1.10 MAINTENANCEANDSERVICE
A. PreventiveMaintenanceRequirements:provideapreventativemaintenanceplanwithattachedproceduresindicatedbymeterandcomponentmanufacturers.Performmaintenanceproceduresforaperiodof1yearaftergovernmentacceptance,atfrequenciesandusingproceduresrequiredbythemeterandcomponentmanufacturers.Ataminimumandifthemanufacturerissilentonitspreventativemaintenancerequirements,frequencies,deliverablesandactivitiesshallcomplywiththefollowing:
1. PreventiveMaintenanceWorkPlan:prepareaPreventiveMaintenanceWorkPlantoscheduleallrequiredpreventivemaintenance.VAapprovaloftheWorkPlanshallbeobtained.AdheretotheapprovedworkplantofacilitateVAverificationofwork.IftheContractorfindsitnecessarytoreschedulemaintenance,awrittenrequestshallbemadetotheVAdetailingthereasonsfortheproposedchangeatleastfivedayspriortotheoriginallys
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 围术期心肌损伤
- 2023-2024学年山西省大同市平城区三校联考七年级(上)月考数学试卷(10月份)
- 沪科版八年级数学上册第14章全等三角形14-2三角形全等的判定第2课时三角形全等的判定“角边角”课件
- 苏教版八年级生物上册期中素养综合测试课件
- 浙教版八年级数学上册期中考试卷带答案
- 江苏省镇江市2024年中考语文真题试卷(含答案)
- 内蒙古呼伦贝尔市、兴安盟重点名校2024年中考押题数学预测卷含解析
- 化 学物质的变化和性质:化学变化和物理变化课件-2024-2025学年九年级化学人教版(2024)上册
- 哥特式教学课件
- 六年级科学下册让身体热起来教案青岛版
- 《燕歌行(并序)》课件
- 2023年辽宁石化职业技术学院高职单招(数学)试题库含答案解析
- GB/T 2312-1980信息交换用汉字编码字符集基本集
- FZ/T 73001-2016袜子
- 5月30日中国科技工作者日-大力弘扬科学家精神课件(带内容)
- 国家开放大学-《中国古代教育哲学》形成性考核作业作业册解答
- 教育学课件王道俊6版
- 数学组备课组期末成绩分析
- 量化研究课件
- 国家开放大学-操作系统(本)章节测试参考答案(整理版)
- 列那狐的故事习题及答案
评论
0/150
提交评论