文档简介

电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告保定四方三伊电气1/8本仪器可测量电力谐波、频率、三相不平衡度、电压偏差等电能质量各项指标。产品名称:电能质量监测仪 产品型号:SFDZ-3序列号: 检验日期:环境温度:0~40℃ 环境湿度:≤90%检验依据:GB/T19862-2023电能质量监测设备通用要求FLUKE6100A,XD-5192-6.5电压表、中国哈尔滨电表厂产D76-0.1一、 基波检验50H60V、120VZ电流输入:50mA、1A、2A、3A工频电流信号其结果如下:输入工频电压误差分析输入电压输入电压60V120V表记读数60.01120.0分析结果60.01120.0误差0.0000.000输入工频电流误差分析输入电流表记读数分析结果误差50mA0.050A0.050A0.000A1A1.0031.0020.0012A2.0042.0060.0023A3.0143.0170.003二、谐波含有率检验:〔1〕下:电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告时,允许误差为相对误差。时,允许误差为相对误差。60V谐波次数含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕20.7%0.05%0.7111%5%0.9893%5%2.9868%5%7.99830.7%0.05%0.6841%5%0.9883%5%3.0018%5%7.99440.7%0.05%0.6761%5%0.9973%5%3.0108%5%8.02550.7%0.05%0.6961%5%0.9823%5%2.9878%5%8.01460.7%0.05%0.6971%5%0.9953%5%3.0138%5%7.98770.7%0.05%0.6821%5%1.0143%5%2.9878%5%7.99180.7%0.05%0.7051%5%1.0083%5%3.0218%5%8.01290.7%0.05%0.7121%5%1.0233%5%3.0048%5%8.008100.7%0.05%0.7041%5%1.0143%5%3.0088%5%8.005110.7%0.05%0.7021%5%1.0033%5%3.0258%5%8.024120.7%0.05%0.7161%5%1.0273%5%3.0168%5%8.031130.7%0.05%0.7151%5%1.0153%5%3.0328%5%8.013140.7%0.05%0.7041%5%1.0163%5%3.0088%5%8.010150.7%0.05%0.6981%5%1.0213%5%3.0218%5%8.014160.7%0.05%0.6951%5%0.9943%5%2.9978%5%7.995170.7%0.05%0.6981%5%0.9953%5%2.9888%5%7.992180.7%0.05%0.7141%5%0.9893%5%2.9998%5%7.996190.7%0.05%0.7111%5%0.9973%5%2.9878%5%7.997200.7%0.05%0.6891%5%0.9953%5%2.9988%5%7.982210.7%0.05%0.6871%5%1.0233%5%2.8988%5%7.996220.7%0.05%0.7141%5%1.0153%5%2.9928%5%8.005230.7%0.05%0.7031%5%1.0073%5%2.8998%5%8.010240.7%0.05%0.7171%5%1.0213%5%3.0218%5%8.022250.7%0.05%0.6871%5%1.0053%5%3.0328%5%8.031由表中可以看出,实测值与输入值比较,误差满足GB/T19862-2023中规定的允许误差要求。注:表中当输入谐波电压含有率<1%时,允许误差为确定误差,当输入谐波含有率≥1%基波电压为220V谐波次数含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕20.7%0.05%0.6991%5%1.0163%5%2.9998%5%7.89530.7%0.05%0.6851%5%0.9873%5%2.9888%5%7.97640.7%0.05%0.6951%5%1.0153%5%2.9788%5%7.98250.7%0.05%0.7021%5%0.9983%5%2.9868%5%7.89660.7%0.05%0.7131%5%0.9843%5%3.0138%5%7.97570.7%0.05%0.6941%5%0.9953%5%3.0228%5%7.98980.7%0.05%0.6981%5%0.9923%5%3.0138%5%8.01390.7%0.05%0.7061%5%1.0143%5%2.9858%5%8.003100.7%0.05%0.7111%5%1.0073%5%3.0128%5%8.025110.7%0.05%0.7051%5%1.0213%5%3.0048%5%8.024120.7%0.05%0.7101%5%1.0323%5%3.0168%5%8.026130.7%0.05%0.7091%5%1.0063%5%3.0078%5%8.013140.7%0.05%0.6851%5%1.0203%5%3.0148%5%8.033150.7%0.05%0.6941%5%1.0063%5%3.0358%5%7.998160.7%0.05%0.7011%5%1.0153%5%3.0088%5%7.985170.7%0.05%0.6971%5%0.9943%5%3.0238%5%7.985180.7%0.05%0.6991%5%1.0033%5%3.0168%5%7.994190.7%0.05%0.6871%5%0.9913%5%3.0118%5%7.982200.7%0.05%0.6951%5%0.9863%5%2.9868%5%8.014210.7%0.05%0.6901%5%0.9843%5%2.9978%5%8.002220.7%0.05%0.7011%5%1.0063%5%2.9798%5%8.023230.7%0.05%0.7131%5%1.0143%5%2.9888%5%8.011240.7%0.05%0.7021%5%1.0023%5%3.0328%5%8.023250.7%0.05%0.7091%5%0.9883%5%3.0228%5%8.003由表中可以看出,实测值与输入值比较,误差满足GB/T19862-2023中规定的允许误差要求。注:表中当输入谐波电压含有率<1%时,允许误差为确定误差,当输入谐波含有率≥1%时,允许误差为相对误差。〔2〕谐波电流检测:用谐波电流发生器为仪器输入信号,仪器显示谐波电流与输入值比较结果如下:电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告时,允许误差为相对误差。时,允许误差为相对误差。1A谐波次数含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕21%0.15%0.9963%5%2.9898%5%7.99720%5%19.9231%0.15%0.9973%5%2.9958%5%7.98820%5%19.8841%0.15%1.0173%5%2.9888%5%7.99520%5%19.8751%0.15%0.9853%5%2.9978%5%7.98920%5%19.9861%0.15%0.9863%5%3.0158%5%7.98320%5%20.0871%0.15%0.9843%5%2.9868%5%8.01520%5%19.9681%0.15%1.0213%5%2.9848%5%7.98420%5%19.9791%0.15%0.9953%5%2.9918%5%8.01620%5%20.12101%0.15%0.9883%5%3.0248%5%8.02420%5%20.23111%0.15%1.0133%5%3.0118%5%8.03520%5%20.05121%0.15%1.0023%5%3.0248%5%8.02120%5%20.08131%0.15%1.0143%5%3.0168%5%8.03420%5%20.30141%0.15%1.0213%5%3.0138%5%7.99220%5%20.23151%0.15%1.0153%5%3.0258%5%7.98620%5%20.15161%0.15%1.0163%5%3.0088%5%8.01220%5%20.02171%0.15%1.0213%5%3.0128%5%8.03520%5%20.27181%0.15%1.0143%5%3.0258%5%8.02720%5%20.18191%0.15%0.9873%5%3.0168%5%7.98820%5%19.84201%0.15%1.0203%5%2.9948%5%7.98920%5%19.96211%0.15%0.9983%5%2.9878%5%7.98920%5%19.95221%0.15%1.0143%5%3.0158%5%8.02720%5%20.08231%0.15%1.0123%5%3.0238%5%8.00320%5%20.07241%0.15%1.0033%5%3.0318%5%8.01820%5%20.12251%0.15%1.0213%5%3.0148%5%8.01220%5%20.23由表中可以看出,实测值与输入值比较,误差满足GB/T19862-2023中规定的允许误差要求。3%时,允许误差为确定误差,当输入谐波含有率≥3%5A谐波次数含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕含有率输允许误差实测值〔%〕21%0.15%0.9973%5%2.9878%5%7.98520%5%20.0431%0.15%0.9883%5%2.9958%5%7.99620%5%19.8941%0.15%0.9853%5%2.9888%5%7.98820%5%20.0751%0.15%0.9953%5%2.9958%5%7.98720%5%19.8761%0.15%1.0113%5%3.0018%5%8.02920%5%19.9871%0.15%0.9973%5%2.9838%5%7.98820%5%19.8981%0.15%1.0113%5%2.9898%5%7.99720%5%20.1591%0.15%1.0143%5%3.0148%5%8.01320%5%20.04101%0.15%1.0073%5%3.0158%5%8.00720%5%20.12111%0.15%1.0183%5%3.0228%5%8.02620%5%19.93121%0.15%1.0213%5%3.0048%5%8.00520%5%20.16131%0.15%1.0353%5%3.0278%5%8.01920%5%20.01141%0.15%1.0083%5%3.0158%5%8.02720%5%20.22151%0.15%1.0123%5%2.9978%5%8.03620%5%20.15161%0.15%0.9873%5%2.9828%5%8.01420%5%20.24171%0.15%1.0093%5%3.0018%5%8.02920%5%19.89181%0.15%0.9973%5%3.0138%5%8.01120%5%19.95191%0.15%1.0143%5%2.9988%5%7.99620%5%19.96201%0.15%0.9983%5%3.0088%5%8.01320%5%20.14211%0.15%0.9953%5%2.9878%5%8.00820%5%20.05221%0.15%1.0113%5%3.0158%5%8.01020%5%20.13231%0.15%1.0203%5%3.0238%5%8.02120%5%19.87241%0.15%1.0153%5%3.0018%5%8.02120%5%19.95251%0.15%1.0333%5%3.0298%5%8.01920%5%20.24由表中可以看出,实测值与输入值比较,误差满足GB/T19862-2023中规定的允许误差要求。3%时,允许误差为确定误差,当输入谐波含有率≥3%时,允许误差为相对误差。电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告电能质量监测仪检验报告三、频率偏差输入额定值输入额定值显示值220V的沟通额定电压,误差≤±0.01HZ检测结果49HZ50HZ51HZ49.0150.0051.00误差范围满足GB/T19862-20235.2.2准确度要求四、三相不平衡度输入额定值显示值%输入额定值显示值%10%10.1230%30.06检测结果1%〕误差范围满足GB/T19862-20235.2.2度要求输入额定值输入额定值显示值%2%2.0114%4.024误差范围满足检测结果 GB/T19862-2023准确度要求五、电气性能检验检验工程电压拉偏

检测方法180V-264V2

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论