BRITISHSTANDARD
Compressedair—
Part8:Testmethodsforsolidparticlecontentbymassconcentration
ICS71.100.20
NOCOPYINGWITHOUTBSIPERMISSIONEXCEPTASPERMITTEDBYCOPYRIGHTLAW
BSISO
8573-8:2004
Britishstandards
BSISO8573-8:2004
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
Nationalforeword
ThisBritishStandardreproducesverbatimISO8573-8:2004andimplementsitastheUKnationalstandard.
TheUKparticipationinitspreparationwasentrustedtoTechnicalCommitteeMCE/8,Compressors,pneumatictools,pneumaticmachinesandvacuum
technology,whichhastheresponsibilityto:
—aidenquirerstounderstandthetext;
—presenttotheresponsibleinternational/Europeancommitteeany
enquiriesontheinterpretation,orproposalsforchange,andkeepthe
UKinterestsinformed;
—monitorrelatedinternationalandEuropeandevelopmentsandpromulgatethemintheUK.
Alistoforganizationsrepresentedonthiscommitteecanbeobtainedonrequesttoitssecretary.
Cross-references
TheBritishStandardswhichimplementinternationalpublicationsreferredtointhisdocumentmaybefoundintheBSICatalogueunderthesectionentitled“InternationalStandardsCorrespondenceIndex”,orbyusingthe“Search”
facilityoftheBSIElectronicCatalogueorofBritishStandardsOnline.
Thispublicationdoesnotpurporttoincludeallthenecessaryprovisionsofacontract.Usersareresponsibleforitscorrectapplication.
CompliancewithaBritishStandarddoesnotofitselfconferimmunityfromlegalobligations.
Summaryofpages
Thisdocumentcomprisesafrontcover,aninsidefrontcover,theISOtitlepage,pagesiitoiv,pages1to8,aninsidebackcoverandabackcover.
TheBSIcopyrightnoticedisplayedinthisdocumentindicateswhenthedocumentwaslastissued.
ThisBritishStandardwas
publishedundertheauthorityoftheStandardsPolicyand
StrategyCommitteeon
17June2004
©BSI17June2004
ISBN0580439607
Amendmentsissuedsincepublication
Amd.No.
Date
Comments
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
INTERNATIONAL
STANDARD
ISO
8573-8
Firstedition2004-02-01
Compressedair—
Part8:
Testmethodsforsolidparticlecontentbymassconcentration
Aircomprimé—
Partie8:Méthodesd'essaipourladéterminationdelateneurenparticulessolidesparconcentrationmassique
ReferencenumberISO8573-8:2004(E)
ii
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
iii
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
Page
Contents
Foreword iv
1Scope
1
2Normativereferences
1
3Termsanddefinitions
1
4Unitsandsymbols
2
5Selectionofmethods
2
6Samplingtechniques
2
7Measurementmethods
3
8Evaluationoftestresults
6
9Uncertainty
6
10Testreport
7
AnnexA(informative)Sampletestreport
8
iv
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
Foreword
ISO(theInternationalOrganizationforStandardization)isaworldwidefederationofnationalstandardsbodies
(ISOmemberbodies).TheworkofpreparingInternationalStandardsisnormallycarriedoutthroughISO
technicalcommittees.Eachmemberbodyinterestedinasubjectforwhichatechnicalcommitteehasbeen
establishedhastherighttoberepresentedonthatcommittee.Internationalorganizations,governmentaland
non-governmental,inliaisonwithISO,alsotakepartinthework.ISOcollaboratescloselywiththe
InternationalElectrotechnicalCommission(IEC)onallmattersofelectrotechnicalstandardization.
InternationalStandardsaredraftedinaccordancewiththerulesgivenintheISO/IECDirectives,Part2.
ThemaintaskoftechnicalcommitteesistoprepareInternationalStandards.DraftInternationalStandardsadoptedbythetechnicalcommitteesarecirculatedtothememberbodiesforvoting.PublicationasanInternationalStandardrequiresapprovalbyatleast75%ofthememberbodiescastingavote.
Attentionisdrawntothepossibilitythatsomeoftheelementsofthisdocumentmaybethesubjectofpatentrights.ISOshallnotbeheldresponsibleforidentifyinganyorallsuchpatentrights.
ISO8573-8waspreparedbyTechnicalCommitteeISO/TC118,Compressors,pneumatictoolsandpneumaticmachines,SubcommitteeSC4,Qualityofcompressedair.
ISO8573consistsofthefollowingparts,underthegeneraltitleCompressedair:
—Part1:Contaminantsandpurityclasses
—Part2:Testmethodsforaerosoloilcontent
—Part3:Testmethodsformeasurementofhumidity
—Part4:Testmethodsforsolidparticlecontent
—Part5:Testmethodsforoilvapourandorganicsolventcontent
—Part6:Testmethodsforgaseouscontaminantcontent
—Part7:Testmethodsforviablemicrobiologicalcontaminantcontent
—Part8:Testmethodsforsolidparticlecontentbymassconcentration
—Part9:Testmethodsforliquidwatercontent
Part2isunderrevision.
1
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
Compressedair—
Part8:
Testmethodsforsolidparticlecontentbymassconcentration
1Scope
ThispartofISO8573specifiestestmethodsfordeterminingthesolidparticlemassconcentrationincompressedair,expressedasthemassofsolidparticleswithmaximumparticlesizelimits.Thelimitationsofthemethodsarealsogiven.Oneofaseriesofstandardsaimedatharmonizingaircontaminationmeasurements,itidentifiessamplingtechniquesandalsogivesrequirementsforevaluation,uncertaintyconsiderationsandreportingfortheairpurityparametersolidparticlesbymassconcentration.ThetestmethodsaresuitablefordeterminingpurityclassesinaccordancewithISO8573-1.(ParticlecontentbasedoncountingparticlesisdealtwithinISO8573-4.)
2Normativereferences
Thefollowingreferenceddocumentsareindispensablefortheapplicationofthisdocument.Fordatedreferences,onlytheeditioncitedapplies.Forundatedreferences,thelatesteditionofthereferenceddocument(includinganyamendments)applies.
ISO1219-1,Fluidpowersystemsandcomponents—Graphicsymbolsandcircuitdiagrams—Part1:Graphicsymbols
ISO3857-1,Compressors,pneumatictoolsandmachines—Vocabulary—Part1:General
ISO5598,Fluidpowersystemsandcomponents—Vocabulary
ISO8573-1,Compressedair—Part1:Contaminantsandpurityclasses
ISO8573-2,Compressedair—Part2:Testmethodsforaerosoloilcontent
ISO8573-4,Compressedair—Part4:Testmethodsforsolidparticlecontent
3Termsanddefinitions
Forthepurposesofthisdocument,thetermsanddefinitionsgiveninISO3857-1,ISO5598,ISO8573-1andISO8573-4apply.
2
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
4Unitsandsymbols
ForthepurposesofthispartofISO8573,thefollowing,includingnon-SI-preferred,unitsareused:
—1bar=100000Pa;
—1l(litre)=0,001m3;
—bar(a),usedforexpressingabsolutepressure;
—bar(e),usedforexpressingeffectivepressure.
ForthegraphicsymbolsusedinFigure1,seeISO1219-1.
5Selectionofmethods
Thegravimetricmethodtobeusedissuitableformassconcentrationmeasurement,however,wherewaterandoilispresentinthecompressedair,itshallbereducedtoaminimum.
AsuitablemethodforsolidparticlediametermeasurementmaybeselectedfromthosegiveninTable1.
Table1—Solidparticlediametermeasurementmethods
Typeofmethod
Maximumsolidparticlediameter
d
µm
Liquidwaterandoilcontaminant
mg/m3
Microscopemethod
d>0,5
<20
Particlesizermethod
0,1<d<40
Notadmitted
6Samplingtechniques
Thesamplingshallbemadeatorneartheactualpressureandataconstantflowrate.
Thechoiceofsamplingmethodwilldependupontheactuallevelofcontaminationandthecompressedairflowinthecompressedairsystem.Forsamplingmethods,seeISO8573-2andISO8573-4.
Forpartialflowsampling,itshouldbenotedthat,wherelargeparticlesizesareinvolved,theeffectsofgravitycouldintroducesamplingerrors.
Compressedairsamplesmayberoutedbackintothemainpipeorventtotheatmosphereaftermeasurement.Thevalueofairsampleparameters(pressure,temperature,airvelocity,etc.)shallbewithintherangesspecifiedbythetestequipmentmanufacturer.MethodB1usesfullflowsamplingfromthemainpipeflowbymeansofaY-piece.
3
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
7Measurementmethods
7.1General
Thetestequipmentandinstrumentsshallbeingoodworkingorder.Considerationshallbegiventothecalibrationrequirementsofthemeasurementequipmentusedasgivenintheapplicableinstructions.
Theindicatedmethodsmaybeusedatanypointinacompressedairsystemusingportableinstrumentswhereconditionsofmeasurementaresatisfiedandavailableconnectorsandshut-offvalvesexistforconnectiontothecompressedairsystem.
Inordertoguaranteetherequiredaccuracyofdeterminationofsolidparticlecontentbythegravimetricmethod,thetotalcontentofwaterandoilaerosolsinthecompressedairsamplingshallbelessthan20mg/m3forsamplingMethodAandlessthan5mg/m3forsamplingMethodsB1andB2.
Referenceshouldbemadetothemeasurementequipmentmanufacturerinrespectoftheapplicabilityoftheequipment.
Thegravimetricmethoddealswiththeseparationandtheweighingofsolidparticlesthatarepresentinacompressedairsample.Theinfluenceoftemperature,pressure,humidityandothercontaminantsofcompressedairshallbetakenintoconsideration.
7.2Testequipment
7.2.1General
Airflowispassedthroughthetestequipmentviasuitablein-linevalveswhichhavebeenpreviouslycheckedtoensuretheydonotcontributetothelevelofcontaminationalreadypresent.
ThegeneralarrangementofthetestequipmentforthegravimetricmethodshallbeinaccordancewithFigure1.
NOTEThenumbersgivenbetweenparenthesesinthesubclausetitlesrefertothenumberingoftheelementsin
Figure1.
Forsymbols,seeISO1219-1.
Key
1samplingpoint
2shut-offvalve
3heater(ifrequired)
4membraneholder
5pressuregauge
6
7
8
910
thermometer
flowcontrolvalve
airflowmeter
shut-offvalve
dischargeoutlet
Figure1—Circuitdiagramoftestequipmentforgravimetricmethod
4
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
7.2.2Membraneholder(4)
Themembraneshallbemanufacturedfromhydrophobichigh-efficiencymaterial.
NOTEForadescriptionofatypicalmembraneanditsholder,seeISO8573-2.
7.2.3Flowcontrolvalve(7)
Inordertoadjusttheflowaccurately,useavalvewithfineadjustment.
7.2.4Pressuregauge(5)
Thepressurevaluesshallberecordedduringtheentireperiodofthetest.
Theaccuracyofmeasurementofthepressureshallbebetterthan±2%ofreading.
7.2.5Thermometer(6)
Thetemperaturevaluesshallberecordedduringtheentireperiodofthetest.
Theaccuracyofmeasurementofthetemperatureshallbebetterthan±1°C.
7.2.6Airflowmeter(8)
Theflowratevaluesshallberecordedduringtheentireperiodofthetest.
Theaccuracyofmeasurementoftheflowrateshallbebetterthan±5%.
7.2.7Pipes,connectors,shut-offvalves(2and9)
Therequirementsforpipes,connectorsandshut-offvalvesshallbeaccordingtoISO8573-2.
7.2.8Heater(3)
Theheatermaybeusedtodecreasethelevelofliquidwaterandoilcontaminantcontentinthecompressedairsampletothevaluespecifiedin7.1.Reducingtheamountofliquidwaterandoilcontentbyheatingand/orthereductionofthepressureofthecompressedairshallnothaveaninfluenceonsolidparticlecontentinthecompressedairsample.
7.3Testprocedure
7.3.1Preparationformeasuring
TheproceduresforpreparationformeasuringshallbeinaccordancewithISO8573-2.Theweightofthedrymembraneshallbedeterminedbeforethesampleistaken.
7.3.2Durationoftest
Theoptimumdurationofthecompressedairsamplingmaybedeterminedafterthefirstproofmeasurementtodeterminethetentativesolidparticleconcentration.
Approximatedurationoftest,t,inminutescanalsobedeterminedbythefollowinginequality:
<t<
mmin
cplimq
m
max
cplimq
(1)
5
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
where
mministheminimumrequiredamountofsolidparticlecontentonthemembrane,inmilligrams;
mmaxisthemaximumpermittedamountofsolidparticlecontentonthemembrane,inmilligrams;
Cplimistheassumedormaximumpermittedamountofsolidparticlecontentinthecompressedair,inmilligramspercubicmetre;
qisthecompressedairdischargethroughthemembrane,incubicmetresperminute.
Themassofsolidparticlescollectedonthemembraneshallbeinrange1mg<m<5mgon1cm2ofthemembranesurface.
7.3.3Measurementofsolidparticlemassconcentration
Ifliquidwaterandoilcontaminantsareabsentinthecompressedairflow,thesolidparticlemassconcentrationforeachsampleisdeterminedasadifferencebetweenmassesofthetestmembranebeforeandafterairsampling,dividedbythetotalvolumeofairpassedthroughthemembrane.Afterairsamplingandbeforeweighing,thetestmembraneshouldbeplacedinadesiccatoroverasuitabledesiccant,e.g.silicagel,for10-15minoruntilthemassofmembraneisstable.
Ifthereareliquidwaterandoilcontaminantsinthecompressedairflow,theyshallberemovedafterairsamplingandbeforeweighingofthetestmembrane.Forthispurpose,thetestmembraneshallbeplacedinthedesiccatoroversulphuricacidfor2h.Then,thetestmembraneiscarriedinthechemicalfunnelontheconicalwall(thefiltrateisoverthemembrane),pressedtotheconicwallwiththeglassstickandtreatedseveraltimesbysmallportionsofasuitablesolventoftotalvolume10-15mlfordissolvingandremovingoftheoil.Afterthat,thetestmembraneshallbemaintainedfor2-3minatatemperatureof20-30°Candthenweighed.
Othermethodsforremovalofwaterandoilfromthetestmembranearepermittediftheyhavenoinfluenceonsolidparticlecontentofthetestmembraneaftersamplingthecompressedair.
Themaximumuncertaintyofmeasurementofmassshallbebetterthan±2%.
7.4Calculationofresults
Itisnecessarytoensurethatresultsarestable,repeatableandpresentedinaformthatshowsthattheyareso.Thesolidparticlemassconcentrationcpninmg/m3foreachmeasurementshallbedeterminedbytheformula:
pn
c=
mn−m0
qntn
(2)
where
m0isthemassoftestmembranebeforesampling,inmilligrams;
mnisthemassoftestmembraneaftersampling,inmilligrams;
qnistheflowrateofsamplingairthroughthemembrane,incubicmetresperminute;
tnisthesamplingtime,inminutes.
7.5Determinationofmaximumdiameterofsolidparticles
ThemeasurementmethodsofmaximumdiameterofsolidparticlesidentifiedinTable1shallbecarriedoutinaccordancewithISO8573-4.
6
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
8Evaluationoftestresults
8.1Referenceconditions
Thereferenceconditionsforsolidparticlemassconcentrationvolumestatementsareasfollows:
—Airtemperature:20°C;
—Airpressure:1bar(a);
—Relativewatervapourpressure:0%.
8.2Influenceofhumidity
Themeasuredsolidparticlemassconcentrationshallberecalculatedtorefertothedryairvolumeasgivenbythepartialpressureoftheairatthesamplingpoint.Undernormalconditions,theeffectofhumidityonvolumecanbesmallandtherequirementtocalculateitseffectisusuallynotrequired.
8.3Influenceofpressure
Thesolidparticlemassconcentrationshallberecalculatedtoreferencepressureconditions.
Thesolidparticlemassconcentrationwillvaryindirectproportionintheratioofsystemtosampleabsolutepressure.
8.4Influenceoftemperature
Thesolidparticlemassconcentrationshallberecalculatedtoreferencetemperatureconditions.
Temperaturecouldalsoaffectsolidparticlemeasurementresultsifthetemperatureexceedsthestabilityoftheparticlesmeasuredortheratingofthesamplingequipment.
8.5Averagevalues
Dependingonthereproducibilityofthemethod,themeasurementfacilityandtheexperienceofthepartiesinvolvedintheprovisionofthemeasurementfacility,theaverageofseveralconsecutivemeasurementsatthesamplepointshallbeused.
Theaveragesolidparticlesmassconcentrationcpinmilligramspercubicmetreshallbedeterminedbythe
resultsofnolessthanthreemeasurementsusingtheformula:
(3)
c=
p
cp1t1+cp2t2+...+cpntn
t1+t2+...+tn
where
cp1,cp2,…,cpn
t1,t2,…,tn
arethesolidparticlecontentintheairsamples,inmilligramspercubicmetre;
arethesamplingtimes,inminutes.
9Uncertainty
Theuncertaintyofthemethoddependsontheequipmentusedandtheaccuracyoftheresultcalculation.Thetotaluncertaintyoftheauthorizedresultsofthetestshallbe±10%.
7
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
10Testreport
10.1Statements
StatementsofthesolidparticlemassconcentrationandthemaximumsolidparticlediameterinthecompressedairshallbemadesuchthatthevaluescanbeverifiedinaccordancewiththeproceduresofthispartofISO8573.
Theinfluenceofanyfactors—e.g.oilcontaminantsorsamplepipe—presentinthesamplethatcouldaffecttheresultofparticleconcentrationmeasurementshallberecorded.
10.2Statementformat
ThetestreportusedtodeclaresolidparticlemassconcentrationaccordingtothispartofISO8573shallcontainthefollowing:
a)Adescriptionofthecompressedairsystemanditsworkingconditions,withsufficientdetailforthedeterminationofthevalidityofthedeclaredmassconcentrationvalue:
1)volumeflowrate;
2)samplingtime;
3)pressure;
4)temperature;
5)othercontaminants(includingwaterandoil).
b)Adescriptionofthesamplingpointwherethesamplesweretaken.
c)Adescriptionofthesamplingandmeasurementsystemused,inparticularthematerialsandequipmentused,anddetailsofitscalibrationrecord.
d)Thephrase“DeclaredsolidparticlemassconcentrationinaccordancewithISO8573-8”,followedby
1)thefigurefortheactual,averagemeasuredvalueevaluatedinaccordancewithClause8andcalculatedtorefertothereferenceconditions;
2)thefigurefortheactual,averagemeasuredvalueevaluatedinaccordancewithClause8,referringtotheactualconditions;
3)thesolidparticleconcentration,expressedinmilligramspercubicmetreatactualandreferenceconditions;
4)thepressureandtemperaturetowhichthemeasurementrefers;
5)thefigurefollowedbyastatementregardingtheapplicableuncertainty;and
6)thedateofthecalibrationrecord.
e)Thedateofthesamplingandmeasurements.
AsampletestreportispresentedinAnnexA.
8
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO8573−8:2004
AnnexA
(informative)
Sampletestreport
Contentofsolidparticlesincompressedairbymassconcentration
Generaldescriptionofcompressedairsystem,testcondition,samplepoint:
____________________________________________________________________________________________
Testmethodapplied:
Samplingmethodapplied:
Listoftestequipmentusedandrespectivecalibrationdates:
____________________________________________________________________________________________
TestresultsofsolidparticlesmassconcentrationinaccordancewithISO8573-8
Test
No.
Testdateandtime
Compressedairparameters
Maximum
solid
particles
diameter
µm
Solidparticlesmassconcentration
mg/m3
Temperature
°C
Pressure
bar(e)
Totalsamplevolume
m3
Actual
condition
Referencecondition
1
2
3
...
...
...
...
Averagevalue:
Reportedby:
Date:
Authorizedby:
Date:
Ifthemeasurementisoutsideaparticularrange,thenidentifyasbeing“notmeasured”.
blank
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
LicensedCopy:LondonSouthBankUniversity,LondonSouthBankUniversity,FriDec2217:28:23GMT+00:002006,UncontrolledCopy,(c)BSI
BSISO
8573-8:2004
BSI
389ChiswickHighRoadLondon
W44AL
BSI—BritishStandardsInstitution
BSIistheindependentnationalbodyresponsibleforpreparing
BritishStandards.ItpresentstheUKviewonstandardsinEuropeandattheinternationallevel.ItisincorporatedbyRoyalCharter.
Revisions
BritishStandardsareupdatedbyamendmentorrevision.Usersof
BritishStandardsshouldmakesurethattheypossessthelatestamendmentsoreditions.
ItistheconstantaimofBSItoimprovethequalityofourproductsandservices.
Wewould
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 《ZnO纳米棒@碳纤维复合材料的制备以及发电性能研究》
- 《《礼记·乐记》与《诗学》和谐思想比较研究》
- 《上品尚城房地产公司涉税业务内部控制研究》
- 2024年石材工程承揽协议
- 2024年度单位公共场所装修及设施配置合同3篇
- 2024年度金融机构委托担保消费借款协议3篇
- 2024年版艺术展览场地租赁合同3篇
- 新建打孔机项目可行性研究报告
- 皮棉清理机项目立项申请报告
- 新建锌锰电池项目立项申请报告
- 2024年1月浙江省普通高校招生选考科目考试思想政治试题(含答案)
- 造纸行业岗位安全操作规程
- 律师事务所人员管理制度
- 带封面的新员工入职登记表
- 20以内的加法口算练习题4000题 205
- 玻璃打胶记录
- 《全媒体营销与运营(微课版)》-教学大纲
- Module3 Unit2 Do they like apples?(教学设计)-2024-2025学年外研版(一起)英语二年级上册
- 医院教学工作汇报
- 篮球球星姚明课件
- 2024-2030年中国计算机视觉行业市场发展趋势与前景展望战略分析报告
评论
0/150
提交评论