




版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1vSAN6.5TechDeckPoweredbyVMwarevSANandvSphereRunsonanystandardx86serverPoolsHDD/SSDintoashareddatastoreDeliversenterprise-gradescaleandperformanceManagedthroughper-VMstoragepoliciesDeeplyintegratedwiththeVMwarestackvSpherevSANvSANDatastore
SupportingabroadvarietyofusecasesvSANBusinessCriticalAppsVirtualDesktops(VDI)DR/DATest/DevDMZROBOManagementStagingvSANLeveragesNext-GenerationHardwarePersistenceTiervSANNVMeSSDNVDIMMvSANNVMeNVDIMMvSANleveragesnext-genhardwareRe-Platformtodeliverthelowest$/Gigand$/IOPSCachingTierNVMeAllFlashupto150KIOPSPerHostvSAN,deeperdive5vSANobjectsandcomponentsstripe-2bstripe-2aRAID-0MirrorCopystripe-1bstripe-1aRAID-0witnessMirrorCopyRAID-1ThevSANdatastoreisanObjectStoreEachObjecthasmultipleComponentsThistoallowyoutomeetAvailabilityandPerformancerequirementsDataisdistributedbasedonVMStoragePolicyFlashDevicesAll
writesandthevastmajorityofreadsareservedbyflashstorageWrite-backBuffer(30%)(or100%inall-flash)Writesacknowledgedassoonastheyarepersistedonflash(onallreplicas)ReadCache(70%)Activedatasetalwaysinflash,hotdatareplacecolddataCachemiss–readdatafromHDDandputincacheAperformancetiertunedforvirtualizedworkloadsHighIOPS,low$/IOPSLow,predictablelatency7Achievedwithmodestcapacity:~10%ofHDDdiskgroupvSANDiskGroupsvSANusestheconceptofdiskgroupstopooltogetherflashdevicesandmagneticdisksassinglemanagementconstructsDiskgroupsarecomposedofatleast1flashdeviceand1-7capacitydevicesFlashdevicesareuseforreadcache/writebufferStoragecapacitycanbeprovidedbyeithermagneticdisksorflashbaseddevicesDiskgroupscannotbecreatedwithoutaflashdeviceCanhave5diskgroupsperhost=35capacitydevicesperhost8diskgroupdiskgroupdiskgroupdiskgroupEachhost:5diskgroupsmax.Eachdiskgroup:1flashdevice+1-7capacitydevicesDefineapolicyfirst…vSANcurrentlysurfacesfiveuniquestoragecapabilitiestovCenterServer9What
If
APIsAssignittoaneworexistingVMWhenthepolicyisselected,vSANusesittoplace/distributetheVMtoguaranteeavailabilityandPerformance10NumberofFailurestoTolerateDefinesthenumberofhosts,diskornetworkfailuresastorageobjectcantolerate.For“n”failurestolerated,“n+1”copiesoftheobjectarecreatedand“2n+1”hostcontributingstoragearerequired!11esxi-01esxi-02esxi-03esxi-04vSANPolicy:“Numberoffailurestotolerate=1”~50%ofI/Ovmdkwitness~50%ofI/ORAID-1vmdkNumberofDiskStripesPerObjectThenumberofHDDsacrosswhicheachreplicaofastorageobjectisdistributed.Highervaluesmayresultinbetterperformance.12esxi-01esxi-02esxi-03esxi-04vSANPolicy:“Numberoffailurestotolerate=1”+“StripeWidth=2”stripe-1astripe-2awitnessstripe-1bstripe-2bRAID-1RAID-0RAID-0FaultDomains,increasingavailabilitythroughawarenessCreatefaultdomainstoincreaseavailabilityFourdefinedfaultdomainsFD1=esxi-01,esxi-02FD3=esxi-05,esxi-06FD2=esxi-03,esxi-04FD4=esxi-7,esxi-08Toprotectagainstonerackfailureonly2replicasarerequiredandawitnessacross3failuredomains!13FD2FD3FD4vmdkvmdkwitnessFD1RAID-1esxi-01esxi-02esxi-03esxi-04esxi-05esxi-06esxi-07esxi-08vSpherevSANAnatomyofaHybrid/FlashWriteVMrunningonhostesxi-01esxi-01isownerofvirtualdiskobjectNumberOfFailuresToTolerate=1Objecthas2replicasonesxi-01andesxi-03GuestOSissueswriteoptovirtualdiskOwnercloneswriteoperationInparallel:sends“prepare”optoesxi-01(locally)andesxi-03esxi-01,esxi-03persistoperationtoflash(log)esxi-01,esxi-03ACKprepareoperationtoownerOwnerwaitsforACKfromboth‘prepares’andcompletesI/O!Later,ownercommitsbatchofwritesesxi-01esxi-02esxi-03vmdkvmdkRAID-1vSpherevSANDe-stagingWritesfromFlashtoHDD(hybrid)DatafromcommittedwritesaccumulateonFlash(WriteBuffer)FromdifferentVMs/virtualdisksElevatoralgorithmflusheswrittendatatoHDDasynchronouslyPhysicallyproximalbatchesofdataperHDDforimprovedperformanceConservative:overwritesaregood;conserveHDDI/OHDDwritebuffersareflushed,beforediscardingwritesfromSSDvmdkvmdkvmdkesxi-01esxi-02esxi-03vSpherevSANDe-stagingWritesfromflashtoflash(all-flash)DatafromcommittedwritesaccumulateonFlashCache(WriteBuffer)FromdifferentVMs/virtualdisksInall-flash,blocksthatarewrittenmostoften(hot)stayinwritecache.Inall-flash,blocksthatareinfrequentlyaccessed(cold)arede-stagedtoflashcapacitylayer.vmdkvmdkvmdkesxi-01esxi-02esxi-03vSpherevSANAnatomyofaHybridReadGuestOSissuesareadonvirtualdiskOwnerchoosesreplicatoreadfromLoadbalanceacrossreplicasNotnecessarilylocalreplica(ifone)AblockalwaysreadsfromsamereplicaAtchosenreplica(esxi-03):readdatafromflashReadCache,ifpresentOtherwise,readfromHDDandplacedatainflashReadCacheReplace‘cold’dataReturndatatoownerCompletereadandreturndatatoVMvmdkvmdk123456esxi-01esxi-02esxi-03vSpherevSANAnatomyofaAll-FlashReadGuestOSissuesareadonvirtualdiskOwnerchoosesreplicatoreadfromLoadbalanceacrossreplicasNotnecessarilylocalreplica(ifone)AblockalwaysreadfromsamereplicaAtchosenreplica(esxi-03):readdatafrom(write)FlashCache,ifpresentOtherwise,readfromcapacityflashdeviceReturndatatoownerCompletereadandreturndatatoVMvmdkvmdk123456esxi-01esxi-02esxi-03vSANCachingAlgorithmvSANexploitstemporalandspatiallocalityforcachingPersistentcachebythereplica(flash)Nodatalocality?(vSANclientside)ImprovedflashutilizationinclusterAvoiddatamigrationwithVMmigrationDRS:10sofmigrationsperdayNolatencypenaltyNetworklatencies:5–50microseconds(10GbE)Flashlatencieswithrealload:~1millisecondsvSANsupportsin-memorylocalcacheMemory:verylowlatencyViewAccelerator(CBRC)Ordersperminute5-minutemovingaveragevMotionvMotionTime(seconds)OrdersperminuteConsistentperformancethroughoutButwhatisvSANreallyabout?Simplicity20ReallySimpleSetup21DeduplicationandCompressionEnable?FaultDomains,2nodeorstretchedcluster?ManualorAutomaticDiskClaiming…EaseofDay0,1and2operationsvSpherevSANvSpherevSANHealthChecksPerformanceMonitoringCapacityReportsvSphereAPIsvSphereUIConfigurationvSANHealth–ReactiveHealthChecksIntroducedwithvSAN6.0IncorporateinthevSphereWebClientvSANHealthChecktoolinclude:LimitschecksvSANHCLhealthPhysicaldiskhealthNetworkhealthStretchedclusterhealth23vSANHealth–ProactiveHealthChecksProactivetoolsrunningonvSANclusterandpre-productiontestsVMCreationtestStoragePerformanceMulticastperformancetestNicefeatureforProofofConcepts(POCs)24PerformanceServiceEnableitonceIntegratedwithvSphereSimplifiedmetricsBackend(vSAN)Frontend(VM)DistributedArchitectureNoSPOFHistoricaldataStatusmonitoredbyhealthchecks25CapacityReportsDedupeandCompressionSavingsGroupbyObjectTypeFilesystemoverheadDedupeoverheadChecksumoverheadVirtualdisksSwapHomenamespace26vSphereAlerting 70+vSANHealthAlarmsManymorevSpherealarmsAlertviaSNMP/SMTPCreatecustomalarmsUseVMwareESXiVOBsor
ObservationIDsforvSANvSANManagementAPI6.2
interfaceforbespokesolution27vRealizeOperations+LogInsightvROpshasvSANawarenessStorageManagementPackvSANDashboards
andHeatMapsHostandDeviceStatisticsHealthAlertsCanalsomakecustomdashboardsLogInsightalsohasvSANawarenessvSANcontentpackLogaggregationfromvSANnodesIntegrationwithVROPSalerting28March2015
AllFlash
64NodeCluster
2xHybridSpeedSeptember2015
StretchedCluster
Replication:5minRPO
2-nodeforROBOMarch2016
Deduplication
Compression
QualityofServicevSAN6.0vSAN6.1vSAN6.2AcceleratingInnovationvSAN5.5vSAN–StretchedCluster30Active-ActivedatacentersvSANclustersplitacross2sites!EachsiteisaFaultDomain(FD)Site-levelprotectionwithzerodatalossandnear-instantaneousrecoveryAutomatedfailoverTodayTechnicalDetailsSupportforupto5msRTTlatencybetweendatasites10GbpsbandwidthexpectationWitnessVMcanresideanywhere200msRTTlatency100MbpsbandwidthrequirementvSphereVSANvSAN–DisasterRecoveryTodayReplication
betweenvSANdatastoresenablesRPOaslowas5
minutesLeverageSiteRecoveryManagerfordisasterrecoveryorchestrationStretchedacrossmetrodistance,replicatedacrossgeo!vSpherevSANSiteRecoveryManagervSphereReplicationvSpherevSANSiteRecoveryManagervSphereReplicationasyncreplicationAnydistanceallowing>=5minRPO<=5msRTT,10GbERemoteOfficeBranchOfficeDeploymentsvSAN6.1supports2-nodeforROBOdeploymentsBothhostsonlyusedtostore“data”ExtensionofvSANStretchedClustersolutionEachhostisaFaultDomain(FD)AllsitesmanagedcentrallybyonevCenterinstance32TechnicalDetailsOnewitnesshostneededpervSANclusterWitnessnodecanbeanESXiVM500msRTTlatency1.5MbpsbandwidthrequirementvSpherevSANvSpherevSANvSpherevSANvSpherevSANvSpherevSANesxi-01esxi-02esxi-03NearlinededuplicationandcompressionperdiskgrouplevelEnabledonaclusterlevelDeduplicatedwhende-stagingfromcachetiertocapacitytierFixedblocklengthdeduplication(4KBBlocks)CompressionafterdeduplicationIfblockiscompressed<=2KBOtherwisefull4KBblockisstoredBetaDeduplicationandCompressionforSpaceEfficiencyvmdkvmdkvmdkAllFlashOnlyNewin6.2Significantspacesavingsachievable,makingtheeconomicsofanall-flashvSANveryattractive33RAID-5InlineErasureCodingWhenNumberofFailurestoTolerate=1andFailureToleranceMethod=Capacity
RAID-53+1(4hostminimum)1.33xinsteadof2xoverhead20GBdiskconsumes40GBwithRAID-1,nowconsumes~27GBwithRAID-5RAID-5ESXiHostparitydatadatadataAllFlashOnlyESXiHostdataparitydatadataESXiHostdatadataparitydataESXiHostdatadatadataparityNewin6.234RAID-6InlineErasureCodingWhenNumberofFailurestoTolerate=2andFailureToleranceMethod=Capacity
RAID-64+2(6hostminimum)1.5xinsteadof3xoverhead20GBdiskconsumes60GBwithRAID-1,nowconsumes~30GBwithRAID-6AllFlashOnlyESXiHostparitydatadataRAID-6ESXiHostparitydatadataESXiHostdataparitydataESXiHostdataparitydataESXiHostdatadataparityESXiHostdatadataparityNewin6.235IntroducingvSAN6.5Q42016iSCSIAccess
2NodeDirectConnect
ManagementvSAN6.52-nodeDirectConnectvSAN6.5vSANDatastorewitnessvsanmanagementwitnessAbilitytoconnectthetwonodesdirectlyusingcrossovercablesSeparatevSANdatatrafficfromwitnesstraffic(2nodeonly)TwocablesbetweenhostsforhigheravailabilityofnetworkAllowsforLayer-2andLayer-3topologiesandstrictseparationoftrafficstreams2-nodeDirectConnect–ConfigurationDisablevSphereHAvMotionVMkernelinterfacesettingExplicitFail-overorder=uplink1
active/uplink2standbyvSANVMkernelinterfacesettingExplicitFail-overorder=uplink2active/uplink1standbySetthedesignatedwitnessVMkernelinterfacetowitnesstraffictype:esxclivsannetworkipadd-ivmkx-T=witnessValidatethetraffictypeiswitness:“TrafficType:witness”esxclivsannetworklistContinuewith2-nodesetupThenenableHAfortheclusterNote:FromthevSphereWebClient,thevmknicinterfacewillnolongerbeselectedforvSANtraffic.
Thisshouldnotbere-enabledinthevSphereWebClient!vSAN6.5vSANDatastorewitnessvsanmanagementwitnessProvideblockstoragethroughvSANiSCSIvSANiSCSITargetServiceenablesBlockStorage!SupportforPhysicalOracleRACClustersStorageforphysicalworkloads
ConfigurationdetailsMaxLUNsizeof62TBSupportsCHAPUniformconfigurationofVMkernelsProvidesallcorevSANfunctionalityfortheiSCSItargetDedupeandCompression,RAID-1,RAID-5,RAID-6iSCSITargetiSCSIInitiatoriSCSIInitiatoriSCSINetworkiSCSIObjectiSCSIObjectvSAN6.5vSAN
DatastoreEasyiSCSIconfigurationthroughWebClientEnableCreateMonitorvSAN6.5HighAvailability(HA)KeytechnologiesforHAiSCSIredirectMulti-pathIO(MPIO)EverytargethasanownerInitiatorcanconnecttoanyhostsActive/PassiveHATargetownerXIwanttoaccesstarget1.Target1isonesxi-02Target1isonesxi-03iSCSIXiSCSIesxi-01esxi-02esxi-03vSAN6.5vSAN6.5iSCSI:InitialSetup42vSAN6.5iSCSI:TargetsandLUNsViewvSAN6.5iSCSI:Creating/ManagingTargetsandLUNs44vSAN6.5iSCSI:InitiatorGroupViewandEdit45vSAN6.5CaveatsiSCSII/OoperationmightbeinterruptedduringiSCSItargetfailover(TransparentFailoverandclustervirtualIPisnotsupportedcurrently)AnyiSCSIinitiatorcandiscoveriSCSItargetsMCS(Multi-ConnectionperSession)isnotsupportedALUAisnotsupportediSNSisnotsupportedOnlineresizingofLUNisnotsupportedcurrentlyIntegrationwithVSANperformanceserviceisnotavailableMonitoringofactiveiSCSIclientsessionstoaLUNisnotavailable.HardwareHBA’snotsupportedvSAN6.5SupportlatesthardwareinnovationsvSpherevSANvSANDatastore
512evSAN6.5SupportforNVMeforworkloadsrequiringhighperformance512edrivesupporttoenablelargercapacitydrivesLatestnetworkingtechnologieslike25/40/100GbpsSupportforworkloadsthatarehighlytransactionalwithlowlatencyusingin-memorytechnologiesNewPowerCLISupportvSAN6.5HealthCheckandremediationCapacityandResyncMonitoring
Proactivetesting2nodeandstretchedclustersupportExtendVSANtoContainersandCNAPhotonControllerClusterManagersvSphereWorksoff-the-shelfwithDocker,Swarm,Kubernetes,…PersistentDockerVolumeDrivervSphereIntegratedContainersDockerAPICompatibilityPersistentVolumeDriverVM-likecontainerisolationPhotonPlatformVSANprovenstorageservicesavailablewithPhoton100%APImanagedVSANDesignedforDevOps
VMvCenterServerPrimaryClusterPhotonVSANforPhotonPrimaryClustervSphereVSAN6.5VIC
cnewvSAN6.5vSANBeta:AdvancedHCIsecurityandprotectionSECURESoftwareEncryptionforDataatRestPROTECTNestedFaultDomainsForStretchedClustersMANAGEEnhancedStorageandNetworkMonitoringThispresentationcontainsproductfeaturesthatarecurrentlyunderdevelopment.Featuresaresubjecttochange,andmustnotbeincludedincontracts,purchaseorders,orsalesagreementsofanykind.
Technicalfeasibilityandmarketdemandwillaffectfinaldelivery.Pricingandpackagingforanynewtechnologiesorfeaturesdiscussedorpresentedhavenotbeendetermined.
BETA3waystofindoutforyourselfhow
VMware-poweredHCIcanhelpyourorganizationSTRESSRELIEFHCIPOWEREDBYVIRTUALSAN53@vmwarevsanvSAN6.1and6.2Features54vSAN–StretchedCluster55Active-ActivedatacentersvSANclustersplitacross2sites!EachsiteisaFaultDomain(FD)Site-levelprotectionwithzerodatalossandnear-instantaneousrecoveryAutomatedfailover5msRTT,10GbETodayVMwarevSphere&vSANvSphere
witnessTechnicalDetailsSupportforupto5msRTTlatencybetweendatasites10GbpsbandwidthexpectationWitnessVMcanresideanywhere200msRTTlatency100MbpsbandwidthrequirementvSAN–DisasterRecovery56Today5msRTT,10GbEVMwarevSphere&vSANAnydistance>5minRPOSiteRecoveryManagervSphere&vSANSiteRecoveryManagerReplication
betweenvSANdatastoresenablesRPOaslowas5
minutesExclusivelyavailabletovSAN6.x,leveragesvSphereReplicationLeverageSiteRecoveryManagerfordisasterrecoveryorchestrationStretchedacrossmetrodistance,replicatedacrossgeo!vSphere
witnessROBODeploymentsvSAN6.1supports2-node(ROBO)deploymentsBothhostsonlyusedtostore“data”ExtensionofvSANStretchedClustersolutionEachhostisaFaultDomain(FD)AllsitesmanagedcentrallybyonevCenterinstance57witnesswitnesswitnessvSphere&vSANvSphere&vSANvSphere&vSANvSphere&vSANTechnicalDetailsOnewitnesshostneededpervSANclusterWitnessnodecanbeanESXiVM500msRTTlatency1.5MbpsbandwidthrequirementDeduplicationandCompressionforSpaceEfficiencyNearlinededuplicationandcompressionperdiskgrouplevelEnabledonaclusterlevelDeduplicatedwhende-stagingfromcachetiertocapacitytierFixedblocklengthdeduplication(4KBBlocks)CompressionafterdeduplicationIfblockiscompressed<=2KBOtherwisefull4KBblockisstoredBetaesxi-01esxi-02esxi-03vmdkvmdkvSphere&vSANvmdkAllFlashOnlyNewin6.2Significantspacesavingsachievable,makingtheeconomicsofanall-flashvSANveryattractive58RAID-5InlineErasureCodingWhenNumberofFailurestoTolerate=1andFailureToleranceMethod=Capacity
RAID-53+1(
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025房地产项目认筹营销推广服务合作协议
- 2025版借调员工知识产权保护与保密协议
- 二零二五版高标准临时商业空间租赁合同样本
- 2025年度市政公用工程施工合同履行与纠纷解决论文
- 2025年度厨房电器销售与安装服务合同
- 2025年【中式面点师(中级)】模拟试题及答案
- 2025春部编新人教版九年级下册语文课题研究计划
- 三年级上册语文培优辅差学困生帮扶计划
- 二零二五年破产重整法律服务合同规范指南
- 二零二五年度建筑安全生产责任保险合同
- 2023年度湖北省政府采购评审专家资格高分通关题型题库附解析答案
- 老旧小区PE管道改造方案
- 2024北京西城初二(上)期末语文试卷及答案
- 《城市轨道交通不间断电源(UPS)整合设计规范》
- 2025高考数学专项复习:马尔科夫链(含答案)
- 管廊钢结构防火涂料施工方案
- 不窜货保证书
- 《提高利润的78个方法》
- DB34T 3663-2020 植保无人飞机农田施药作业技术规范
- 2025年全国计算机二级考试模拟考试题库及答案(共290题)
- 2024-2030年中国螺旋藻市场投资效益及运行趋势预测分析报告
评论
0/150
提交评论