TestReport

Client:Address:

ShanghaiHanshiMoldingShapeCo.,Ltd.

No.355,YouDongRoad,Shanghai,P.RChina

DUNS: —

TestedSample: ASSYFRONTBEAMPartNumber:55005311

SampleDescription: Model:C30

Materialandgrade:P7-GF45-0790-BK711

ReceivingDate: 2015-03-12 EvaluationType:—

TechnicalSpecification:GMW14650-2013

TestItems:

TestResults:

DimensionalStability

ResistancetoTemperature-HumidityCycle(DimensionalStability)

ResistancetoHigh-HumidityEnvironment

ImpactResistance

Accordingtoclient’srequirements,thetesthasbeenconductedonreceivedsamples.Refertopage2fordetailsofresults.

Editedby:ZhangWeiqi

Checkedby:NingWentao

Approvedby:

Signature:

Signature:

Signature:

Dateofissue:

TestSummary

SectionNo.

ClauseNo.

TestItem

Ref.Standard

Evaluation

Section001

Accordingtoclient’s

requirements

DimensionalStability

Accordingtoclient’s

requirements

Pass

Section002

GMW14650-2013

§4.3

ResistancetoTemperature-HumidityCycle(Dimensional

Stability)

GMW14650-2013

Section003

GMW14650-2013

§4.4

Resistanceto

High-HumidityEnvironment

GMW14729-2010

Pass

Section004

GMW14650-2013

§4.9

ImpactResistance

GMW14093-2013

Pass

D15009701

SamplePhotos

Section001DimensionalStability

Ref.

Standard

Client`srequirement

DateofTest

2015-03-25~2015-03-26

Tested

SampleID.

D150097010102

TestConditions

A:After8hunder110℃,theproductcontourdeformationcomparedwiththeoriginal,parts,evaluation:heightofZ5comparedwiththeinitialstateofnomorethan2mm;

B:Toputproductsatroomtemperature(23±3℃),fromAstateslowlycooledtoBstatemeasurement,evaluation:heightofZ5comparedwiththeinitialstateislessthan1mm;

A:After8hunder-40℃,theproductcontourdeformationcomparedwiththeoriginal,parts,evaluation:heightofZ5comparedwiththeinitialstateofnomorethan2mm;

B:Toputproductsatroomtemperature(23±3℃),fromAstateslowlycooledtoBstate

measurement,evaluation:heightofZ5comparedwiththeinitialstateislessthan1mm.

TestInstruments

No.

Name

Type

Number

Calibration

ValidDate

1

Highandlowtemperature

testchamber

SDJ41FD

EQ-0032

2015.09.02

Test

Requirement

SeeTestConditions(Accordingtothecustomer’srequirements)

TestResults

Sampl

No.

Condition

Change(mm)

Verdict

Z1

Z6

Z7

Z8

Z9

Z10

1#

Afterhightemp

0.07

0.04

0.66

0.21

0.47

0.66

P

Roomtemp

0.03

0.01

0.55

0.20

0.25

0.50

P

Afterlowtemp

0.58

0.34

0.74

0.41

0.45

0.40

P

Roomtemp

0.12

0.40

0.50

0.30

0.22

0.31

P

2#

Afterhightemp

0.11

0.18

0.54

0.58

0.40

0.54

P

Roomtemp

0.36

0.16

0.48

0.41

0.31

0.15

P

Afterlowtemp

0.42

0.33

0.67

0.02

0.44

0.24

P

Roomtemp

0.35

0.20

0.45

0.40

0.20

0.15

P

3#

Afterhightemp

0.08

0.07

0.74

0.14

0.45

0.75

P

Roomtemp

0.05

0.04

0.31

0.05

0.22

0.55

P

Afterlowtemp

0.12

0.02

0.41

0.20

0.35

0.45

P

Roomtemp

0.10

0.00

0.32

0.18

0.24

0.15

P

Test

Conclusions

Pass

Remark

P:Pass;F:Fail;“—”:NotApplicable

TestPictures

Testing

Testing

Section002ResistancetoTemperature-HumidityCycle(DimensionalStability)

Ref.

Standard

GMW14650-2013

DateofTest

2015-03-25~2015-04-09

Tested

SampleID.

D150097010401

Sample

Quantity

3pcs

TestConditions

Thiscycleshallbecarriedouttwotimeswithoutinterruption:

Cycle:17±0.5h,-30±3℃→72±1hat85±3℃→24±1h,38±2℃,100%RH→7h±0.5h,

-30±3℃→24±1h,38±2℃,100%RH→24±1h,22±3℃

Checktheappearanceandthedimensionscomparedwiththeoriginalparts.

TestInstruments

No.

Name

Type

Number

Calibration

ValidDate

1

Highandlow

temperaturetestchamber

SDJ610A

EQ-0069

2015.12.14

TestRequirement

Appearance:Testpiecesshallshownocracking,crazing,appreciablecolorchanges,discoloration,cloudiness,blistering,objectionableshrinkage,anddeformation,lossofadhesiontothesubstratebetweenlayersofthecompositeorotherchangesdetrimentalto

serviceability.

TestResults

SampleNo.

Result

Verdict

Appearance

Dimension

1#

Shownocracking,crazing,appreciablecolor

changes,discoloration,cloudiness,blistering,objectionableshrinkage,anddeformation,

Seethenextpage

2#

Shownocracking,crazing,appreciablecolorchanges,discoloration,cloudiness,blistering,

objectionableshrinkage,anddeformation,

3#

Shownocracking,crazing,appreciablecolor

changes,discoloration,cloudiness,blistering,objectionableshrinkage,anddeformation,

Test

Conclusions

Remark

P:Pass;F:Fail;“—”:NotApplicable

SampleNo.

Condition

Result(mm)

1#

Change

Z1

Z6

Z7

Z8

Z9

Z10

-0.11

-0.41

-0.05

-1.31

-1.46

-0.86

2#

Z1

Z6

Z7

Z8

Z9

Z10

-0.57

-1.47

-2.03

-1.41

-1.32

2.25

3#

Z1

Z6

Z7

Z8

Z9

Z10

-1.10

-1.97

-2.65

-1.32

-1.32

-1.87

Section002ResistancetoTemperature-HumidityCycle(DimensionalStability)

TestPictures

Pre-test1#

Pre-test1#

Pre-test2#

Pre-test2#

Pre-test3#

Pre-test3#

Testing

Post-test1#

Post-test1#

Post-test2#

Post-test2#

Post-test3#

Post-test3#

Section003ResistancetoHigh-HumidityEnvironment

Ref.

Standard

GMW14729-2010

DateofTest

2015-03-20~2015-03-27

Tested

SampleID.

D150097010104

TestConditions

Measurethedimensionsoftestpiecesbeforetest;

Placetestpiecesat(40±3)℃,~100%RHfor(168±2)hand(22±3)℃,(50±5)%RHfor24h;

Evaluatethesurfacevisuallyandmeasurethedimensionsoftestpiecesaftertest.

TestInstruments

No.

Name

Type

Number

Calibration

ValidDate

1

Highandlowtemperature

testchamber

SDJ610A

EQ-0069

2015.12.14

TestRequirement

Testpiecesshallshownosignificantsurfacechanges,particularlychangesincolororgloss,orotherchangesdetrimentaltoserviceability.Thedimensionsshouldbeno

significantchanges.

TestResults

Seethenextpage.

Test

Conclusions

Pass

Remark

P:Pass;F:Fail;“—”:NotApplicable

SampleNo.

Result

Verdict

Appearance

1#

Shownosignificantsurfacechanges

P

2#

Shownosignificantsurfacechanges

P

3#

Shownosignificantsurfacechanges

P

SampleNo.

Change(mm)

Z1

Z6

Z7

Z8

Z9

Z10

1#

0.24

0.77

0.04

0.41

0.22

0.07

2#

0.15

0.61

0.23

0.11

0.06

0.14

3#

0.04

0.54

0.14

0.05

0.21

0.91

Section003ResistancetoHigh-HumidityEnvironment

TestPictures

Testing

Testing

1#Pre-test

1#Post-test

2#Pre-test

2#Post-test

3#Pre-test

3#Post-test

Section004ImpactResistance

Ref.

Standard

GMW14093-2013

DateofTest

2015-04-13~2015-04-14

Tested

SampleID.

D150097010501

TestConditions

Testintheas-receivedcondition,afterheatagingandaftertemperaturecycling;

Conditioning:(22±3)°C&(50±5)%RHfor24h;

Freezertemperature:-30°C;Freezingtime:4h;Impactenergy:5J.

TestInstruments

No.

Name

Type

Number

Calibration

ValidDate

1

Lowtemperature

freezingfreezer

DW-FW251

EQ-0101

2015.07.21

2

Fallingballimpact

tester

LQ-001

YQ-0069

2015.12.15

Test

Requirement

Nocracksorbreakage.

TestResults

SampleNo.

Result

Verdict

As-received

1#

Nocracksorbreakage

P

2#

Nocracksorbreakage

P

3#

Nocracksorbreakage

P

Afterheataging

4#

Nocracksorbreakage

P

5#

Nocracksorbreakage

P

6#

Nocracksorbreakage

P

After

temperaturecycling

7#

Nocracksorbreakage

P

8#

Nocracksorbreakage

P

9#

Nocracksorbreakage

P

Test

Conclusions

Pass

Remark

P:Pass;F:Fail;“—”:Notapplicable;

Wedirectlyusedthesamplesthathadbeentreatedintheagingtestandtemperaturecyclingtesttoperformimpacttest.

Section004ImpactResistance

TestPictures

Testing

Testi

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论