版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
WATERTANKCONSTRUCTIONMETHODSTATEMENT(CIVILWORK)TABLEOFCONTENTTOC\o"1-2"\h\z\uHYPERLINK3HYPERLINK3HYPERLINK6HYPERLINK15HYPERLINK18HYPERLINKvalueofnotlessthan5tonneswhentestedinaccordancewithB.S.812Part111andmaybedepositedbelowwaterwithouttheassociateduseofcompactionplant.SeiveanalysisasperBS1377:P2methodshouldbe9.2or9.3latestedition.TABLE1FREEDRAININGMATERIALB.S.SIEEVESIIZE%BYWEIIGHTPPASSINNG10mmUpto10005mmNotmoreethann850.600mmmNotemorrethaan450.075mmmNotemorrethaan52.3PLACINGANDCOMPACTIONREQUIREMENTSOnlyapprovedmaterialsshallbeusedintheconstructionofembankmentsfoundationstandingwater.Intheformationoftheembankmentfoundationitisstrictlyforbiddentopushtheexcavatedmaterialsfromthesideoftheroadtotheembankmentfoundationbymeansofbulldozers.Thefillmaterialshallbedeliveredandspreadinlayersnotexceeding25cmcompactedthickness.Thelayersoffillshallbegraded,leveled,pulverizedandmixed,withwateraddedasnecessary,toensurehomogeneousconditionsthroughthefulldepthoftheuncompactedlayer.Forfielddensitytestingrefertospecificationsubsection2/19.Thecompacteddensityofthefillshallbeequaltoorgreaterthan95(ninetyfive)percentoftheMaximumDryDensityasdeterminedbyBS1377Part4(method3.5or3.6).Allslopes,linesandgradesshallbetrue,correct,andaccurateandaccordingtothosedirectedandapprovedbytheEngineer.The"earthworksformationlevel"inembankmentsshallbeaccuratetotheauthorisedprofilegradetoplusone(1)cmorminustwo(2)centimetresand,the'topofimprovedsubgrade'level,plusorminusone(1)centimetrefor3locationsmaximumeach100minterval.Selectedmaterialshallbeplacedwhereverrequired.WherediscrepanciesarefoundintheworkCHECshallmakenecessarycorrectionsinamannerapprovedbytheEngineer.2.4MOISTURECONTROLREQUIREMENTSWhenthemoisturecontentoftheembankmentsoildoesnotfallwithin+3%oftheoptimummoisturecontent,watershallbeaddedandthoroughlymixedintothesoil,byapprovedmethodsorthematerialshallbeaerated,whicheverisneededtoadjustthesoiltothepropermoisturecontent.Theamountofwatertobeaddedshallbeonlythatamountthatwill,asdeterminedbytheEngineerbyfieldtests,provideamoisturecontentinthesoilwithintherequiredrangeplusareasonableamounttocompensateforevaporationandotherunavoidablelosses.WateraddedinexcessofthisamountshallbeconsideredasexcesswaterandmustberemovedbyaerationorothersuitablemeansasdirectedbytheEngineer.Satisfactorymethodsandsufficientequipmentshallbeusedforthefurnishingandhandlingofthewatersothattherewillbenounduelossduetoevaporationorwaste.Ifwaterisaddedtocutareasorborrowpits,thesurfaceoftheareasorpitsshallbemaintainedinsuchamannerthatwillpreventunduelossofmoistureandsegregation.Useofsalinewaterforearthworkswillonlybepermittedifthepercentageofwatersolublesaltsinthecompactedfilldoesnotexceed3%byweightofdrysoil.Forsubgradematerialmoisturerangerefertosubclause2/ROCKFILLWhereembankmentstobecompactedareformedofmaterialconsistingpredominantlyofrockfragmentsofsuchsizethatthematerialcannotbeplacedinlayersofthethicknessprescribedwithoutcrushing,pulverisingorfurtherbreakingdownthepiecesresultingfromnormalexcavationmethods,thematerialmaybeplacedintheembankmentinlayersnotexceedingathicknesstwicetheaveragesizeofthelargerrocks,exceptthatnolayershallexceed600mmofloosemeasurement.Materialsshallbecarefullyplacedsothatalllargestoneswillbewelldistributedandthevoidscompletelyfilledwithsmallerearth,sandorgraveltoformasolidembankment.Eachlayershallbebladedorlevelledwithmotorgrader,bulldozerorsimilarequipmentcapableofshiftingandformingthelayerintoaneatandorderlycondition.No.rockslargerthaneighty(80)mminanydimensionshallbeplacedinthetoponehundredandfifty(150)mmoftheembankmentunlessotherwisenotedonthedrawings.ConformancetotheseprovisionsandcompactioninamannerandtoapointofconsolidationapprovedbytheEngineerwillbeconsideredasfulfilmentoftherequirementsforthetypeofcompactionshownonthedrawings.Normally,compactiontestswillnotbeperformedintheseareasbuttheEngineerreservestherighttocompactioninsomeothermannerifhedeemsatestnecessarytoensureconsolidation.EachlayermustbeapprovedbytheEngineerbeforethenextlayerisplaced.Embankments,whichareformedofmaterialsthatcontainrockbutalsosufficientcompatiblematerialotherthanrockorotherhardmaterialtomakerollingfeasible,shallbeplacedandcompactedinthemannerandtothepointofconsolidationapprovedbytheEngineer.MoistureshallbeaddedasdirectedbytheEngineer.CompactiontestswillbemadewherevertheEngineerdeterminestheyarefeasibleandnecessary.EachlayermustbeapprovedbytheEngineerbeforethenextlayerisplaced.2.6TESTINGTESTINGMETHODSAmoisturedensitytestinaccordancewithBS1377Part4(method3.5or3.6)willbemadeforeachtypeofsoiltobeusedintheconstructionoftheworktodeterminetheMaximumDryDensity,theOptimumMoistureContentandtheMoistureRangerequiredofthesoilforsatisfactorycompaction.TheFieldDensityandactualMoistureContentofthecompactedembankmentshallbedeterminedbyfieldtestsaccordingtoBS1377Part9(method2.1or2.2)MINIMUMTESTREQUIREMENTSForCHEC'sgeneralguidance,thefollowingtestswillberequiredpriortouse,andduringtheconstructionoftheembankmentandofthesubgrade.3.1GeneralConcreteworkwillconsistoffurnishingallmaterialsandconstructingstructuresoftheforms,shapesanddimensionsshownontheDrawingsorasdirectedinaccordancewiththedetailsshownontheDrawings.3.2MATERIALS3.2.1 CementSULPHATERESISTINGCEMENTSulphateResistingCementwillcomplywithBS4027orASTMC150Type5.Inadditionthecementwillcomplywiththefollowing:Theacidsolublealkalilevelmeasuredas(Na20+0.658K20)willnotexceed0.6%byweightdeterminedinaccordancewithBSEN196
P2(95).Theheatofhydrationwillnotexceed290KJ/Kgat7dayswhentestedinaccordancewithBS4550:Part3Section3.8.Thespecificsurfacewillbenotgreaterthan375m2/kgandnotlessthan280m2/kgwhentestedinaccordancewithBSEN196:Part6.a.Cementwillbedeliveredtositeinbulk,orwiththeEngineer'sapproval,maybesuppliedinsealedbags,whichwillbearthemanufacturer’snameandthedateofmanufacture.Acopyofthemanufacturer’sbatchtestcertificateandcertificateofguaranteewillaccompanyeachconsignment.b.Eachconsignmentofcementwillbekeptseparate,identifiedandusedinorderofdelivery.c.Anyconsignmentnotusedwithin2monthsfromthedateofmanufacturewillnotbeallowedtobeusedintheworks.d.OnebrandonlyofcementasapprovedbytheEngineerwillbeusedthroughouttheworksunlessotherwiseauthorisedbytheEngineerinwriting.FineAggregateforConcreteandMortarThegradationoffineaggregatewillbeinaccordancewithBS882latesteditionexcludinggradingdesignationF.FineAggregatewillbecleansharpnaturaland/orcrushedsandandwillbewithinBS882zonescandmonly.CHECwillmechanicallywashaggregatetoremovesaltsandotherimpuritiesinordertomeettherequirementspecified.CoarseAggregateforConcreteCoarseaggregatewillbepreparedassinglesizedaggregateandblendedtoproducenormalsizegrading.ThecombinedgradingwillbewithintheappropriategradinglimitsgiveninBS882.Aggregatesthataredeleteriouslyreactivewiththealkalisinthecementinanamountsufficienttocauseexcessiveexpansionofconcretewillnotbeused.CHECwillmechanicallywashaggregatetoremovesaltsandotherimpuritiesinordertomeettherequirementspecified.3.2.4 COMBINEDAGGREGATEApprovedcoarseaggregateandfineaggregateineachbatchwillbecombinedinproportionsasspecifiedinBS882andasapprovedbytheEngineer.However,innocasewillmaterialspassingthe0.075mm,sieveexceedthree(3)percentbyweightofthecombinedaggregate.Thecombinedaggregategradationusedintheworkwillbeasspecified,exceptwhenotherwiseapprovedordirectedbytheEngineer.ChangesfromgradationtoanotherwillnotbemadeduringprogressoftheworkunlessapprovedbytheEngineer.WATERCHECwillmakehisownarrangementandobtainapprovalforthesupplyofwater.Themixingwatershouldbeclear,apparentlycleanandfreefrommatterharmfultoconcreteinitsfreshorhardenedstate.Potablewatercanbeused.Thetemperatureofwaterforconcreteshouldnotbelessthan5degreeCelsiusnormore25degreeCelsius.Watermaybecooledtonotlessthan5degreeCelsiusbythegradualadditionofchilledwateroricebutonmixing,noiceparticlesshouldbepresentinthemix.Alternatively,flakedicemaybeused.Waterforcuringconcretewillnotcontainimpuritiesinsufficientamountstocausediscolourationoftheconcrete.SourcesofWaterwillbemaintainedatsuchdepthandthewaterwillbewithdrawninsuchamannerastoexcludesilt,mud,grassandotherforeignmatter.TESTINGAllconcrete,aggregate,cementandwaterwillbesampledandtestedduringconstructionasfrequentlyasdeemednecessarybytheEngineer.AlltestsampleswillbesuppliedbyCHECathisexpense.SampleswillbeobtainedinaccordancewithBS812,BS3148,BS1881andBSEN196.TestingwillbeatthefrequenciesstatedintheSpecificationsorrelevantstandards.AllsamplingwillbecarriedoutbytheEngineer.TRIALMIXESNostructuralconcreteshallbeplacedintheworksuntiltherelevantmixhasbeenapprovedbytheengineer.CHECwill,atleast35daysbeforethecommencementofconcreting,havetrialmixesprepareandtestedinalaboratorytobeapprovedbytheengineer.Whenthemixhasbeenapproved,novariationsshallbemadeintheproportions,theoriginalsourceofthelatterwithouttheconsentoftheengineerwhomayrequirefurtherteststobemade.Theengineermayalsorequirefieldtrialstobemadeonthesitebyfillingtrialmouldstoconfirmthesuitabilityofthemixfortheworks.Inthesetest,thetypeofplantusedformixing,themethodofcompactionused,andtheformworkfacetothemouldshallbesimilarinallrespectstothoseintendedforuseintheworks.WhenCHECintendtopurchasefactorymadeprecastconcreteunits,theengineermaydispensewithtrialmixesandlaboratorytests,providedthatevidenceisgivenwhichsatisfieshimthatthefactoryregularlyproducesconcrete,whichcomplieswiththeSpecification.Theevidenceshallincludedetailofmixproportions,watercementratio,workabilityandstrengthobtainedat7and28days. WORKABILITYWorkabilitywillbeassessedbythefollowingteststherequirementsforwhichwillbeasspecifiedelsewhereinthedocuments.SlumptestwillbeperformedaccordingtoBS1881Part102CompactionfactorwillbeperformedaccordingtoBS1881Part103.VebetimewillbeperformedaccordingtoBS1881Part104FlowtestwillbeperformedaccordingtoBS1881Part105. COMPRESSIONTEST TheCompressiontestswillbeperformedoncubes150x150x150mmasdescribedinBS1881Part116.Sampling,makingtestcubesandcuringofcubeswillbeinaccordwithBS1881Parts101,108and111respectively.3.4FORMWORK3.4.1 General Formworkwillineveryrespectbeadaptedtothestructureandtherequiredsurfacefinishoftheconcrete.Itwillincludealltemporarymouldsforformingtheconcretetotherequiredshapeandfinishandforthesupportofsuchmoulds.Itwillbefixedinperfectalignmentandsecurelyledgedandbracedsoastobeabletowithstand,withoutdisplacementdeflectionormovementofanykind,theweightoftheconstructionandthemovementofpersonsmaterialsandplant.Jointswillbecloseenoughtopreventtheleakageofliquidandfinematerialsfromtheconcrete.TheEngineer'sRepresentativemayatanytimerequirethepriorsubmissionforapprovalofCHEC'sproposalsfordesignandconstructionofformworkincludingsupports.Theformworkwillbeconstructedtopermititsremovalwithoutdamagetotheconcrete.3.4.2 SpacingBlocksandTemporaryConstructionTies Internalspacingblocksandconstructiontieswillbeavoidedasfaras,intheEngineer'sRepresentativeopinion,possibleandpracticable.Whereitisintendedthatthespacingblocksorconstructiontieswillberemovedwhetherbeforeoraftertheconcretehasset,themakinggoodoftheconcretewillbesubjecttotheEngineer'sRepresentative'sapproval.Theremovaloftheblocksortiesmustnotjeopardisethestabilityoftheconstruction.If,withtheapprovaloftheEngineer'sRepresentative,thespacingblocksandconstructiontiesareallowedtoremainintheconcretethentheywillbeofsuchmaterialandofsuchqualitythattheydonotprejudicethestrengthofthework. Concretespacingblockswillbemadeofconcreteatleastequalinqualitytothemainconcrete.Metaltieswillbepositionedsuchthattheydonotcomeintocontactwithanyofthereinforcementorfittingsandnopartofthetiewillbepermanentlyembeddedintheconcretenearerthan5cmtotheexteriorsurfaceoftheconcrete. Allholeswillbefilledwithnon-shrinkgrant.3.4.3 SlabFormsWheretimberisusedforthesoffitsofslabs,theboardswillbeplacedandlaidperfectlytruewithclosejointstopreventthepercolationofliquidorfinesfromtheconcrete.Tongueandgrooveplankswillbeusedifspecified.Allrequisitebearerandstrutswillbeadjustedinpositionandplacedwherenecessaryonbearersasspecifiedinthecaseofbeamforms.3.4.4 TypeofFormwork ExposedConcreteFacesAllconcretefaceswillbeleftasstruckwithafairface,truetolinefinish.Inordertohavethefinishasitwillbeformed,approvedbytheEngineer,testpiecesof1sq.mverticalpanel25cmthickwillbecast.AfterapprovaltheywillberetainedinpositionuntiltheconcreteworkshavebeencompletedthentheywillbedemolishedandremovedfromtheWorks.Aftercarefulinspection,allsuperfluousfinesandsimilarprojectionswillbecarefullyremoved.Norenderorotherappliedfinishwillbeusedtoobtainafairfacetotheconcrete.AllconcretefacestobeexposedinthefinishedworkswillbeadequatelyprotectedagainstdamageandsurfacestainingduringtheexecutionoftheWorks.3.4.2 PreparationofFormworkforConcretingImmediatelybeforetheconcreteisdeposited,theformworkwillbethoroughlycleanedoutandfreedfromsawdust,shavings,wirecuttings,dust,sand,clayandallotherdeleteriousandextraneousmaterials.Temporaryopeningswillbeprovidedintheformworktofacilitatethiswork.Theinsidesurfacesoftheformworkwill,immediatelypriortofinalerection,becoatedwithmouldoil.Themouldoilwillbeofapprovedtypeandwillbeapplieduniformlyandthequantitiesusedwillbetheminimumconsistentwithitspurposes.CHECwillensurethatallsteelreinforcementandadjoiningconcretesurfacesarekeptfreeofmouldoil.Allformworkandreinforcementwillbecleanandfreefromstandingwaterimmediatelybeforeplacingconcrete.3.4.3 ApprovalofFormworkbeforeConcretingCHECwillinallcasesrequesttheapprovaloftheformworkbytheEngineer'sRepresentativeinsufficienttimetoallowaninspectiontobemadeandwillnotcommenceconcretinguntilsuchapprovalisobtained.TheperiodbetweenCHEC'srequestforapprovalandhisintentiontocommenceconcretingwillbenotlessthanoneclearnormalworkingdayandtheEngineer'sRepresentativemayrequirealongerperiodif,inhisopinion,theformworkisofsuchcomplexityastorequireit.SuchapprovalwillnotabsolveCHECofhisresponsibilitiesundertheContract.3.4.4 RemovalofFormwork Allformworkswillbestruckwithoutjarringtheconcreteorsubjectingthesametosuddenshock. Beforestrikinganyformwork,CHECwillsatisfyhimselfthattheconcreteissufficientlyhardenedtobearitsownloadandanyotherloadsthatmaybeplacedonit. Noformworkistoberemoved,ifintheopinionoftheEngineer'sRepresentative,theconcretehasnotsetsufficiently. ApprovaloftheEngineer'sRepresentativewillnotabsolveCHECofhisresponsibilitiesundertheContract.Subjecttotheaboveandtheconcretetestcuberesults,theminimumperiodsfortheremovalofformworkgenerallyareasfollows: Sidesofbeams,wallsandcolumns - 2days Soffitsofbeamsandslabs(propsleftin) - 7days Removalofprops(beamsandslabs) -14days Soffitsofprecastbeams - 7days (ThesetimesmaybereducedonlywiththewrittenapprovaloftheEngineer) Inthecaseofthespecialtypesofformwork,strikingtimesaretobeapprovedbytheEngineer.Ifabeamslabisrequiredtosupportaconstructionloadinexcessofitsdesignload,thebeamorslabistobeproppeduntilthesupportedconstructionhasreachedtheagewhentheproppingmayberemoved.NosupportsfortheshutteringmaybeleftinthefinishedconcretewithoutthewrittenpermissionoftheEngineer.3.4.5 ConcreteBelowGround AllconcreteplacedbelowgroundlevelwillhaveaminimumprotectiontoitsoutsidefaceswithabituminousmembraneasperClauseofthisSpecification.3.5REINFFORCEMMENTSSTEEL3.5.1 GGeneraalALLREINNFORCEEMENT(BARTYPEDESIGGNATIOON'T'')WILLLBEEPOXYYCOATTEDHIIGHYIIELDDDEFORMMEDTYYPE2GRADEE460NN/mm²BARSTOBSS4449..CHECwilllberespoonsiblleforrfurnnishinngreiinforccingssteelinsuufficiientqquantiityanndofthepproperrsizees,leengthssandshapeesshoownonntheDrawiingsfforannygivvensttructuure.3.5.2 MaateriaalSpeecificcationns AllreinnforceementbarswillbbeofadefformeddtypeeinaaccorddancewithBS44449,eexcepttthattplaiinbarrsmayybeuusedwwherespeciificalllyinndicattedonntheDrawiings.PlaiinbarrswilllbeinacccordaancewwithBBS44449. AllsteeelreiinforccementtwilllconfformttotheerequuiremeentsooftheeSpeccificaationssforDeforrmedHHighYYieldSteellBarss,Graade4660Typpe2,unlesssothherwisseshoownonntheDrawiingsoorspeecifieedbytheEEngineeer.EithermmildssteelwhereespeccifieddorccalleddforwillbedeeformeedorplainnbarsscompplyinggwithhASTMMA6155struucturralgrradeoorBS4449orannyequuivaleentNaationaalStaandarddasddirecttedanndappproveddbyttheEnngineeer. TyingwiirewiillbeeNo.116gauugesooftannnealeediroonwirreorNo.118gauugesttainleessstteelwwireoortheeequiivalenntBSspeciificattionffortyyingwwireaandUPPVCcooatedsuitaablefforeppoxyccoateddrebaar. WeldedwwireffabriccwilllbeuusedaasreiinforccementtforconcrretewwhereshownnonttheDrrawinggsanddasddirectted.WWeldeddwireefabrricwiillcoonformmtotthereequireementssofBBS44883. Allreinnforceementwillbbeprootecteedagaainstcorroosionwithafussion-bbondeddepoxxycoaatinginacccordaancewwithtthereequireementssofAASTMAA775/AA775MaandBSS72955.CHECwilllberespoonsiblleforrobtaaininggtheEnginneer’sappprovalltotthestteelbbarsppriortocooatinggcommmencinng.SSuchaapprovvalwiillinnnowwayreelieveeCHECCofhiisressponsiibilittiesuundertheCContraact.CHECwilllfurrnishtothheEnggineerraceertifiicateofcoompliaancefforeaachshhipmenntofcoateedsteeelbaars.TheccertifficateeofccompliiancewillsstatethatrepreesentaativesampllesoffthecoateedbarrshavvebeeentesstedaandthhatthhetesstressultscompllywitththeerequuiremeentsooftheeSpeccificaationss.3.5.3 CConstrructioonofReinfforcemment Steelreeinforrcingwillbbestooredoontimmberppackinngcleearoffthegrounnd.Thhesteeelbaarswiillbeefreeefrommsharrpdefformattions,,rollled-innsilvvers,deeprecesssesoorsurrfacefaultts/bleemisheeswhiichcoouldrresulttiniineffiicienttoriinadeqquatecoatiing.WWhenffixedinthheworrkanddimmeediateelyprriorttoconncretiing,ssteelreinfforcinngwilllbeentirrelyffreeffromlloosemillscalee,loooseruust,ooil,ggreasee,paiint,mmouldoil,andaallottherddeleteerioussandextraaneoussmateerial..Allhookss,bennds,eetc.,unlesssothherwisseshoownonntheDrawiingswwillbbetoBS44466. Beforeoorderiingreeinforrcingsteell,CHEECwilllpreeparebarbbendinngschheduleesathisoowncoostanndsubbmittthemttotheeEngiineerforhhisappprovaal.Baarschheduleeswilllshoowtheeweigghtoffeachhbar,,thetotallweigghtoffeachhbarsizeandtthetootalwweighttofbbars,andbbendinngdiaagramssforbarsinacccordaancewwithBBS44666.TTheleengthofeaachbaarwilllbecalcuulateddinaaccorddancewithBS44466exxceptthatthemminimuumintternallbenddingrradiusswilllbeffourttimesthebbardiiameteer.CHHECwiillallsoprrovideeandsubmiittotheEEngineeerfoorappprovallanyworkiingdrrawinggsaddditionnaltootheContrractDDrawinngswhhichmmaybeefounndneccessarryforrtheproduuctionnofbbarbeendinggscheedulessorfforthhecommpletiionofftheWorkss. TheEngiineer’sappprovallofCCHEC’sworrkingdrawiingsaandbaarbenndingschedduleswilliinnowayrrelievveCHEECofrresponnsibillityfforthhecorrrectnnessoofsucchdraawingssorsscheduules. Steelreeinforrcemenntwilllbebentaccurratelyytottheshhapesandddimenssionsshownnonttheappproveedbarrbenddingllistsordrrawinggs.Baarswiillbeebenttrounndmanndrelssoftthereequisiitediiameteer. SteelreeinforrcemenntwilllbecutaandbeentinnaccoordanccewitthBS4466..Cutttingorbeendinggbyttheappplicaationofheeatissnotpermiitted..WelldingofreeinforrcemenntwilllonllybepermiittedwhenapproovediinwriitingbythheEnggineerr. IfsuchapproovaliisgivventhhenthheworrkmansshipwwillbbeinaccorrdanceewithhBS55135.CHECCwilllsubmmitfuullteechniccaldeetailssofhhisprroposeedproocedurresprriorttoseeekingapprooval. Hotrollledhiighyiieldbbarswwillnnotbeestraaighteenedoorbenntagaain,hhavinggonceebeennbentt.IftheEEngineeergiivesaapprovvaltoobenddmilddsteeelreiinforccementtprojjectinngfroomtheeconccrete,
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025版简易工伤赔偿协议书范本-娱乐行业工伤赔偿3篇
- 2025版跨区域货运风险分担货物运输保险协议3篇
- 2024年物联网农业技术开发与合作协议
- 2024年经销商协作协议范本版B版
- 2024年版无财产有未成年子女离婚合同模板一
- 2025版现代办公场所厂房租赁合作协议书
- 2025年度智慧农业设施包清工承包合同范本3篇
- 2025版投标报价咨询与评估合同3篇
- 2025年抗阿米巴病药合作协议书
- 2025版设备购买合同标的及交付期限3篇
- 吉林大学药学导论期末考试高分题库全集含答案
- 2023-2024学年河北省唐山市滦州市数学七年级第一学期期末教学质量检测模拟试题含解析
- 高考语文新题型+“文学短评”相关写作(真题+技法+练习)
- 2023年小学五年级数学上学期期末水平测试试卷(天河区)
- 中考数学计算题100道
- 集团资产重组实施方案
- GB/T 33195-2016道路交通事故车辆速度鉴定
- (职高)高一语文期末测试题及答案解析
- GB/T 14383-2008锻制承插焊和螺纹管件
- 红色简约大气年会晚会节目单
- 李孟潮个体心理咨询的操作
评论
0/150
提交评论