CENTUMVP培训资料ppt课件_第1页
CENTUMVP培训资料ppt课件_第2页
CENTUMVP培训资料ppt课件_第3页
CENTUMVP培训资料ppt课件_第4页
CENTUMVP培训资料ppt课件_第5页
已阅读5页,还剩86页未读 继续免费阅读

下载本文档

版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领

文档简介

1、CENTUM VPMaintenance CourseDay 3Jan 2021Pro-Safe RSPage.2Table of ContentsDay 3Pro-Safe RS Maintenance Functions-Security-Forcing Function-SCS Maintenance Support Tool-SOE Viewer-Engineering Support-Network Status Display Dialog Box Overview of ProSafe-RS SecurityPage.3Page.4Overview of ProSafe-RS S

2、ecurity1.1 Database Security Management1.2 Security Management of SCS1.3 Security of SCS Maintenance Support ToolPage.5Database Security ManagementIt is possible to set a password for the SCS project so that only authorized users can make changes to the SCS project.- Password for the SCS ProjectIf y

3、ou set a password for the SCS project, users are asked to enter the password when they open the SCS project.- Accessing without a passwordIf you do not know the password, the SCS project can be opened in read-only mode without entering the password after checking Read Only.In this status, the users

4、are not allowed to edit the application logic or generate databases.Operations on the SCS, such as using the forcing function and downloading data, are possible in the read-only status.Setting a Password for the SCS ProjectPage.6Database Security ManagementHow to Set Passwords1. Select Project Prope

5、rties from the File menu of SCS Manager;2. Enter the current password in the Old: field.3. Enter a new password in the New: field, and once again in the Confirm New: field. The password consists of up to eight case-sensitive, alphanumeric characters.4. If you want to access the project but do not kn

6、ow the password, check Read Only option.5. Click the OK button.Database Security ManagementSetting Password for Each POU or FBIt is possible to set a password for each POU or Function Block so that only the authorized users can reference and change important POUs and FBs.When users attempt to edit a

7、 POU or FB for which a password is set, they are required to enter the password. If you do not know the password, you are not allowed to reference or print the POU or FB.Even when a project is opened in read-only mode, the POU or FB is readable after entering the password of the POU or FB.How to Set

8、 Passwords ?Select POU, Right Click mouse button, select property. Then you can select security and key in password, final you select OK.Forcing FunctionPage.8You can use the forcing function to lock variables and forcibly change their values. Specifically, you can lock the variables in application

9、logic, values of input and output channels of I/O modules, data of SCS Link Transmission, Inter-SCS Safety Communication, and Subsystem Communication. The forcing function can be used for SCS maintenance or application debugging.Page.9Forcing Function2.1 I/O Lock Window2.2 SCS Link Transmission Lock

10、 Window2.3 Inter-SCS Communication Lock WindowPage.10 To execute the forcing function, it is necessary to set the SCS security level to Level 1 or 0. The forcing function can be used in the target test, the SCS simulation test and the logic simulation test. However, the I/O Lock Window, SCS Link Tra

11、nsmission Window, Inter- SCS Communication Lock Window,Forcing FunctionExecute the forcing function in the following windows: I/O Lock Window SCS Link Transmission Lock Window Inter-SCS Communication Lock Window Communication I/O Lock Window Multi-Language Editor (FBD) Multi-Language Editor (LD) Dic

12、tionary View Spy List windowPage.11I/O Lock WindowIn the I/O Lock Window, you can perform locking and unlocking operations for individual input/output modules and/or input/output channels (input/output variables). Also you can set values to Input/Output variables. The I/O Lock Window allows operatio

13、n on AIO/DIO modules. In this section, input/output modules refers to AIO/DIO modules.In SCS Simulator of SCS Test Functions, multiple I/O variables can be set all together. Therefore, the initial values of all channels of I/O modules and the testing patterns can be set all together.Page.12I/O Lock

14、WindowCheck if the SCS security level is 0 or 1 using the SCS security level operation function.Put the SCS Manager into Debug mode or Editing mode. To change to Debug mode, choose Debug from Debug menu or click Debug button on the toolbar.Select Maintenance from the Tools menu of SCS Manager. The M

15、aintenance Launcher menu appears.Select I/O Lock Window from the Maintenance Launcher menu. The I/O Lock Window appears. It is not possible to start multiple I/O Lock Windows at the same time, for neither the same SCS project nor different SCS projects. The I/O Lock Window cannot be called up while

16、Build or Download is running. If you try to execute online change downloading, offline downloading, master offline downloading, or restarting of SCS while the I/O Lock Window is open, an error message is displayed and the downloading or restarting will not be executed.How to Call up the I/O Lock Win

17、dowPage.13I/O Lock WindowI/O Lock Window StructureThe I/O Lock Window contains the following components.Page.14SCS Link Transmission Lock WindowOn SCS Link Transmission Lock Window, the communication data of SCS Link transmission can be locked or unlocked. Also you can set values to SCS Link transmi

18、ssion data.In SCS Simulator of SCS Test Functions, it is possible to set values to multiple communication data together. Therefore, the initial values of communication data and testing patterns can be defined all together.Page.15SCS Link Transmission Lock WindowHow to Call up the SCS Link Transmissi

19、on Lock Window1. Check if the SCS security level is 0 or 1 using the SCS security level operation function.2. Put the SCS Manager into Debug mode or Editing mode. To change to Debug mode, choose Debug from Debug menu or click Debug button on the toolbar.3. Select Maintenance from the Tools menu of S

20、CS Manager. The Maintenance Launcher menu appears.4. Select SCS Link Transmission Lock Window from the Maintenance Launcher menu. The SCS Link Transmission Lock Window appears. It is not possible to start multiple SCS Link Transmission Lock Windows at the same time, for neither the same SCS project

21、nor different SCS projects. The SCS Link Transmission Lock Window cannot be called while Build or Download is running.Page.16SCS Link Transmission Lock WindowSCS Link Transmission Lock Window structureThe SCS Link Transmission Lock Window contains the following components.Page.17SCS Link Transmissio

22、n Lock WindowSet Values of SCS Link Transmission DataOn SCS Link Transmission Lock Window, communication data values of a locked station can be set one by one or all together per station.The collective setting of communication data values on a station-by-station basis is possible when using the SCS

23、Simulator during testing.This section explains the operating procedures.On the Inter-SCS Communication Lock Window, the communication data of inter-SCS safety communication can be locked or unlocked. You can also set data values to inter-SCS safety communication FBs.In SCS Simulator of SCS Test Func

24、tions, it is possible to set values to multiple communication data together. Therefore, the initial values of communication data and testing patterns can be defined all together.Page.18Inter-SCS Communication Lock WindowPage.19Inter-SCS Communication Lock Window1. Check if the SCS security level is

25、0 or 1 using the SCS security level operation function.2. Put the SCS Manager into Debug mode or Editing mode. To change to Debug mode, choose Debug from Debug menu or click Debug button on the toolbar.3. Select Maintenance from the Tools menu of SCS Manager. The Maintenance Launcher menu appears.4.

26、 Select Inter-SCS Communication Lock Window from the Maintenance Launcher menu. The Inter-SCS Communication Lock Window appears. The Inter-SCS Communication Lock Window cannot be launched while Build or Downloadis running on SCS Manager. It is not possible to start multiple Inter-SCS Communication L

27、ock Windows at the same time, for neither the same SCS project nor different SCS projects. If the SCS Manager is closed or a different SCS project is opened, the Inter-SCS CommunicationLock Window will be forcibly closed. If you try to execute online change downloading, offline downloading, master o

28、ffline downloading, or restarting of SCS while the Inter-SCS Communication Lock Window isopened, an error message is displayed and the downloading or restarting will not be executed.How to Call up the Inter-SCS Communication Lock WindowPage.20Inter-SCS Communication Lock WindowInter-SCS Communicatio

29、n Lock Window StructureThe Inter-SCS Communication Lock Window contains the following components.Page.21Inter-SCS Communication Lock WindowLocking and Unlocking All Inter-SCS Safety CommunicationFBs Associated with a StationLocking Inter-SCS Safety Communication FBs of a StationThe procedure is as f

30、ollows:1. Choose a station for locking the communication data on the Station List View.2. In the Inter-SCS Safety Communication FB List View, check the discrepancies between the logical data and physical data of the inter-SCS safety communication FBs data values and data status, and make sure that t

31、he discrepancies are acceptable when locking the data.3. Choose Lock Inter-SCS Safety Communication FB from the Lock menu or click Lock button on the toolbar.4. On the confirmation dialog box displayed, click OK so as to lock all the inter-SCS safety communication FBs associated with the selected st

32、ation. Clicking Cancel will cancel the locking.Page.22Inter-SCS Communication Lock WindowUnlocking Inter-SCS Safety Communication FBs of a StationThe procedure is as follows:1. Choose a station to be unlocked in the Station List View.2. In the Inter-SCS Safety Communication FB List View, check the d

33、iscrepancies between the logical data and physical data of the inter-SCS safety communication FBs data values and data status, and make sure that the discrepancies are acceptable when unlocking the data.3. Choose Unlock Inter-SCS Safety Communication FB from the Lock menu or click the Unlock button

34、on the toolbar.4. On the confirmation dialog box displayed, click OK to unlock; or click Cancel if you want to cancel.5. If any inconsistency between logical data and physical data exists in the FBs to be unlocked, a reconfirmation dialog box (*1) will be displayed. Click the OK button on this dialo

35、g box to unlock all the inter-SCS safety communication FBs associated with the selected station together. Click Cancel if you want to cancel the unlocking.*1: In the case of REAL-type data, the reconfirmation dialog box will not be displayed even if inconsistency between data values exists.Page.23In

36、ter-SCS Communication Lock WindowSet Values of Inter-SCS Safety Communication FBsOn Inter-SCS Communication Lock Window, data values can be set for individual inter-SCS safety communication FBs or for all inter-SCS safety communication FBs together on a station- by-station basis.The collective setti

37、ng on a station-by-station basis is possible when using the SCS Simulator during testing.Page.24Inter-SCS Communication Lock WindowIn the Inter-SCS Safety Communication FB List View, double-clicking in a cell between L column and Physical Value column on any line will open a dialog box for setting d

38、ata values or data status of the inter-SCS safety communication FB for that line.Write Data Value Dialog Box (BOOL-type Data)Write Data Value Dialog Box (REAL/INT-type Data)Write Data Status Dialog BoxSCS Maintenance Support ToolPage.25Page.26SCS Status DisplayThe status of SCS is displayed in the f

39、ollowing windows: SCS Status Overview window SCS State Management windowPage.27SCS Status DisplaySCS Status Overview Window StructurePage.28SCS Status DisplaySystem Status List ViewPage.29SCS Status DisplayV net or Vnet/IP StatusDiagnostic Information MarkPage.30SCS Status DisplaySCS StatusCPU Statu

40、sPage.31SCS Status DisplayManagement of SCS StatesThe SCS State Management window displays detailed information about the operating status of CPU modules and input/output modules for a single SCS. If there is an error, the erroneous area is shown using a different color. It also displays whether or

41、not there are any messages that have not been acknowledged.The SCS State Management window allows you to perform the following operations: IOM Download operation, Output Enable Operation and Start Output Module operation Display of detailed information of each input/output modulePage.32SCS Status Di

42、splaySCS State Management Window StructurePage.33SCS Status DisplaySystem report includes SCS Report window and IOM Report window in the SCS State Management Window. The above two windows can be used for displaying SCS status and input/output module status respectively. When abnormality occurs, the

43、details displayed on these windows can help analyzing the causes of problems. The reports can be printed out or savedinto text files.System ReportsPage.34SCS Status DisplaySCS ReportSCS Report displays the SCS status.IOM ReportThe input/output module status or the communication module status detecte

44、d by the SCSCPU module is displayed in the IOM Report window.Page.35SCS Status DisplayPage.36Displaying I/O Channel StatusThe I/O Channel Status dialog box displays the states of channels of all input/output modules of the relevant SCS in the list format.SCS Status Display-I/O Channel Status Dialog

45、BoxClick I/O Channel Status button on the toolbar of the SCS State Management window. The I/O Channels Status dialog box appears.Page.37Display of Input/Output Channel StatusSCS Status DisplayThe error status indicates that the single channel is faulty and/or the error that activates the Output Shut

46、off switch inside the output module has occurred.The output disabled status indicates that the channel is normal, but the output from the application logic to the field is disabled.Operations in the I/O Channel Status Dialog BoxPage.38SCS Status DisplaySetting System TimeThe system date and time can

47、 be set using the Adjust Time dialog box. The date and time specified in the Adjust Time dialog box are reflected on the SCS connected to the same domain and other SENGs. In the case of the CENTUM integration structure, the set date and time are also reflected on its FCS and HIS. Moreover, when mult

48、iple domains are connected through BCV or CGW and it so specified by the builder, the same date and time can be applied to the stations in the connected domains too.The set date and time is applied to the following connected stations: Date/time of the local SENG (Windows date/time) Date/time of all

49、SCS, FCS and HIS Date/time of other SENGsIf an HIS is connected, the time settings made on the HIS are applied to these stations as well.Page.39SCS Status DisplayAdjust Time Dialog BoxClick Time Setup button on the toolbar of the SCS Status Overview window or the SCSState Management window. The Adju

50、st Time dialog box appears.The following items are displayed in the Adjust Time dialog box: CurrentThe current system time is displayed in this area. SettingThe system time can be set in this area.Page.40SCS Status DisplayHow to Set the Date/TimeThe system date and time can be adjusted using the spi

51、n boxes in the dialog box and thenclick the OK button. Click the Cancel button if you want to cancel the setting.If you set the date/time, the date/time of the stations connected to the system are changed.Note that the date/time format conforms to the Windows standard. If Vnet/IP is applied as the c

52、ontrol bus, using SNTP server standard time for time synchronization cannot change the system time from SENG and HIS. If V net is applied as the control bus, the Adjust Time dialog box should be used to settime regardless of what type of time synchronization is applied. When a V net networkand a Vne

53、t/IP network are connected through a V net router that is earlier than style S3, ifthe V net router system time transfer is set to Transfer lower, the system time cannot bechanged from an SENG or HIS on the V net. Moreover, if multiple domains are connected together through BCV or CGW, and if the BC

54、V system time transfer is set to Transfer lower, or the CGW is set to Receive System Time, the system time cannot be changed from an SENG or HIS in the lower level domain.Page.41SCS Status DisplayOutput Enable Operation Overview on Output Enable OperationWhen the operating mode of SCS is Waiting mod

55、e, some output channels are in Output Disable status, so that they cannot output the application logic results. Moreover, after SCS is started, the inter-SCS safety communication cannot send data to consumer side, the SCS Link Transmission and the subsystem communication cannot function either.The O

56、utput Enable Operation will enable the output channels to output the application logicresults, will start the inter-SCS safety communication, the SCS link transmission and the subsystem communications.Output Enable operation can be performed for the whole SCS only. The output channel cannot be speci

57、fied individually. Therefore, you cannot enable only one of the inter-SCS safety communication, SCS Link Transmission or subsystem communication.Page.42SCS Status Display Start Output Module OperationSelect the output module whose output is stopped in Hardware Configuration Tree View of the SCS Stat

58、e Management window. Click Start output module button on the toolbar. After this is confirmed using the Confirmation dialog box, the selected output module starts up.The output from all channels will continue to be 0 even after the output module starts up.Perform the Output Enable Operation. The out

59、put module is connected to the output of application logic and the result of the application logic is output from the module.Note that this Start Output Module operation does not influence the output modules of which the Output Shutoff switch has not been actuated.Page.43SCS Status DisplayIOM Downlo

60、ad ToolIOM Download tool is used to download the input/output configuration information stored in the master database of an SCS project to input/output modules that have been replaced due to a malfunction, etc.After installing an input/output module in a node, or replacing it, it is necessary to per

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论