版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、Procedure Number程序编号HY-MP-COP-002Rev. No版本1Page页码1 of 6Document Status:文件状态: PRE/准备 CFC/执行Reference procedure No./Rev./参考程序编号/版本: N/A不适用Document Title文件名称:Procedure for Calibration of Electrode Portable Oven焊条保温桶检定程序Document Type/文件类型 :Management Procedure管理程序Name &Title姓名及职务Signature/Date签名及日期A
2、pproved by批准Prepared by编制职务:Title:Reviewed by审核Signature/Date:签名及日期QA ReviewerQA审核Translator翻译Translation reviewer译审Copyright Declaration:版权声明 :This document is the property of the SNPEMC. It must not be used, reproduced, transmitted or disclosed without the prior written permission of SNPEMC。本程序未经山
3、东核电设备制造有限公司书面批准不得外用、复制和泄露 Procedure for Calibration of Electrode Portable Oven Procedure No.:HY-MP-COP-002Revision:1Historical Records of Modification修改历史记录版本Rev.发布日期Issue date修改范围及依据Scope and Basis of the Modification1Table of Contents目 录1.Purpose目的32.Scope范围33.Reference Documents参考文件34.Responsibil
4、ities职责34.1Engineering Department工程部34.2Material Section物资组34.3QC Section QC部35.Calibration steps标定步骤45.1Check of prerequisites/检查先决条件45.2Temperature measuring method/温度测量方法45.3Disposal of results/结果处理46.Regular Inspection of Portable Oven During Construction焊条保温桶在使用过程中的检查7.Applicable forms适用表格51. P
5、urpose目的This procedure defines the calibration method and management requirements for electrode portable oven to CV assembly and erection at HaiYang site.本程序叙述了焊条保温筒的检定方法和使用管理要求。2. Scope范围This procedure is applicable for the calibration, using and managing of electrode portable oven of HaiYang CV Pr
6、oject of SNPEMC.本程序适用于SNPEMC海阳CV项目焊接生产过程中焊条保温筒的检定、使用和管理工作。3. Reference Documents参考文件Quality Assurance Manual for Haiyang Project HY-QAM海阳项目质量保证手册 HY-QAM4. Responsibilities职责4.1 Engineering Department工程部4.1.1 Shall prepare electrode portable oven requirements planning according to production demands;
7、根据生产需要,编制焊条保温筒需求计划;4.1.2 Use electrode portable oven correctly.正确使用焊条保温筒。4.2 Material Section物资组4.2.1 Be responsible for procure electrode portable oven and build up calibration records for portable oven.采购焊条保温筒,并建立焊条保温筒标定状态台帐。4.2.2 Be responsible for the periodical calibration, management and maint
8、enance of electrode portable oven.负责焊条保温筒进行定期的标定、管理和维护。4.2.3 Be responsible for pasting right qualification label on portable oven according to appendix 6 in Procedure for Welding Material Control.按焊接材料控制程序附录6的要求在保温桶上粘贴正确的标签。4.3 QC Section QC部4.3.1 Sign off the calibration records of electrode porta
9、ble oven.对焊条保温筒检定记录签字确认;4.3.2 Be responsible for inspection of the qualification labels; supervise the usage of electrode portable oven.检查焊条保温筒上粘贴合格证,对焊条保温筒的使用情况进行监督。5. Calibration steps标定步骤5.1 Check of prerequisites/检查先决条件5.1.1 Power supply(24V or 36V), calibrated thermometer, record form;电源(24V或36
10、V)、标定合格的温度计,记录表格;5.1.2 Qualified operator and QC personnel;合格的操作人员和质检人员。5.2 Temperature measuring method/温度测量方法5.2.1 Switch on power supply for electrode portable oven(24V或36V);接通保温筒电源(24V或36V);5.2.2 The total measuring time is 1 hour, filling in the records every 20 minutes;测量时间为1小时,每间隔20分钟记录;5.2.3
11、 The readings of measured temperature shall be within the range of 80150,the tolerance is ±10.所测温度读数应在80150范围内,温度范围±10.。5.3 Disposal of results/结果处理5.3.1 The electrode thermostats shall be replaced or repaired if they are disabled.在检定过程中,如发现保温筒不能达到使用要求应及时更换、修理;5.3.2 QC shall sing on the el
12、igible calibrated portable oven, and confirm the acceptance label has been pasted on portable oven.QC在检定合格的保温筒标定记录上签字,并监督物资组在标定合格的保温筒外壁贴上合格标签。6. Regular Inspection of Portable Oven During Construction焊条保温桶在使用过程中的检查6.1 General Requirement通用要求6.1.1 Electrode portable oven will be inspected during weld
13、ing construction.焊条保温桶在焊接施工的全过程中要对其温度进行检查。6.1.2 Portable oven shall be inspected prior to putting electrodes into it. These electrodes can only be put into it after the temperature are confirmed.在焊条放入保温桶时应第一次对保温桶进行温度检查。确保温度在规定范围后方可将焊条放入。6.1.3 Temperature after electrodes placed into portable oven sh
14、all be spot-checked every two hour by QC inspector, and results shall be recorded. See section 7 for record sheet.焊条放入保温桶后每隔2小时由QC人员对其温度进行一次抽查。抽查个数应占总使用个数的50%或以上。检查结果形成记录,记录表格见第7部分。6.1.4 After construction, if there are some left electrodes, then the internal temperature of portable oven shall be checked before return.焊接施工结束后,如果保温桶还有剩余未用完的焊条,则应在归还前对内部温度进行一次检查。7. Applicable forms适用表格Inspection Record for Electrode Portable Oven/焊条保温桶温度检查记录(Sam
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2025年攀枝花货运从业资格证试题库及答案
- 《万象城商业模式》课件
- 2024年渔场水产品购销合同
- 2024年度土地平整工程与生态农业合作合同3篇
- 2024塔吊二手买卖合同附带用户培训与认证协议3篇
- 2024年度文化产业投资股权转移及合作开发合同3篇
- 2024年某小区住宅楼建设项目施工合同版B版
- 2024年甲乙丙三方关于联合研发的协议
- 2024年版5G移动通信设备采购合同
- 2024年度无保险劳务派遣劳动派遣服务合作协议书3篇
- 钢中夹杂物控制原理
- 代扣服务协议
- DG∕TJ 08-2255-2018 节段预制拼装预应力混凝土桥梁设计标准
- 办公室租赁合同(英文)_范本范文
- 开姆洛克指南
- 2国家电网公司营配贯通营销数据采录工具业务模型说明书
- 中心试验室标准化管理办法
- 管桩水平承载力计算
- 煤矿运输专业危险源识别、风险评价表(一)
- 库存盘点盈亏处理申请表xls
- 35kV及以下架空电力线路施工及验收规范
评论
0/150
提交评论