1、tunnel dryer - ducting specification隧道烘干机-风管技术说明1/generality1、概述supply and installation of ventilation ducting for spooner tunnel dryer.spooner公司隧道烘干机的风管的供货和安装。the tunnel dryer is composed of 3 main parts:隧道烘干机主要由3段构成: 1 inclined part with 3 modules1个倾斜段,出3个单体构成- 1 top part with 5 modules1个上段,出5个单体构

2、成 1 bottom part with 5 modules1个下段,出5个单体构成general scope of supply:供货范围概况: supply and installation of all ducting for each part including elbows with turning vanes and support as per spooner guide drawings按照spooner公司条件图的要求,供货并安装烘干机各段的所有风管,包括弯 头、导流板和支撑;- installation and supply of all flanges and bolt

3、s供货并安装所冇的法兰和螺栓;- installation of dampers and accessories supplied by spooner安装spooner公司供应的风门和配件;- supply and installation of structure support for wash down ducts, catch basins and heat exchangers供货并安装缓清洗管、集水池,并供货并安装热交换机的支撑结构;- installation of heat exchangers supplied by spooner安装spooner公司供货的热交换机;-

4、supply and installation of exhaust chimney供货并安装排气烟囱;- supply and installation of insulation made of rock wool 75 mm thick thermal coefficient rw3 and aluminum sheet protection 0.6mm thk, installed with screws and with sealing injunction lap供货并安装75mm厚的岩棉保温层,保温系数rw3,外带0.6mm厚的铝板保护 层,使用螺丝安装,接搭处进行密封;- pa

5、inting of all part in carbon steel epoxy primer and finishing ral blue 5000所有碳钢部件喷涂坏氧底漆和面漆,劳尔色卡蓝色5000 (ralblue 5000);- supply of all sealing between flanges, dumpers and equipment. sealing rope high temperature (200°c) dia 6mm compressed to 2mm after installation供应法兰、风门和设备之间的所有密封材料。密封绳耐高温(200&#

6、176;c),直径 6mm,安装后压缩到2mmo2/ part 1 inclined part (exchanger, fresh air fan , exhaust fan and module 3 recirculation fan at +10.00m; recirculation fans for zones 1 & 2 installed at + 5.00m)2、第1段一斜坡段(热交换机、净气风扇、排气扇和位于+10.00m处的第3单体循环 风机;位于+5()()m处的第1、2单体循环风机)the part 1 is composed of第i段rti以下部分构成:a/ e

7、quipment supplied and installed by spoonera> spooner公司供货并已安装的设备 3 dryer modules3个烘干机单体 1 fresh air fan including filter1个净气风扇,带过滤器 3 exhaust fans3个排气扇 3 recirculation fans3个循环风机b/ equipment supplied by spooner but installed by the ducting companyb、spooner公司供货,但是需要风管供应商安装的设备 3 exhaust dumpers 480x

8、480mm3个排气风门,尺寸480x480mm 3 fresh air dumpers 400x400mm3个净气风门,尺寸400x400mm- 3 recirculation inlet dumpers 1600x500mm to be fine tune with the connecting flange of the dryer (no bolts)3个循坏进气风门,尺寸1600x500mm,需与烘干机连接法兰进行微调(无螺 栓)- 3 recirculation outlet dumpers 1100x 1200mm3个循环排气风门,尺寸1100x1200mm- 3 by-pass

9、dumpers 950x800mm3个旁通风门,尺寸950x800mm- 1 heat exchanger1个热交换机- 3 heating batteries3个加热器-3 filters3个过滤器c/ equipment supplied and installed by the ducting companyc、风管供应商供货并安装的设备1 fresh air transition duct to the heat exchanger1个连接到热交换机的净气过渡导管 1 exhaust air transition duct to the heat exchanger1个连接到热交换机的

10、排气过渡导管1 pre heated fresh air transition duct to the fresh air collector1个连接净气收集器的预热净气过渡导管1 wash down duct to the heat exchanger stainless steel 304l 3mm thk1个连接到热交换机的缓清洗管,304l不锈钢,厚度3mm1 catch basin pan to the heat exchanger stainless steel 304l 3mm thk1个热交换机的集水池,304l不锈钢,厚度3mm1 steel structure suppor

11、t for exchanger, wash down , and catch basin carbon steel epoxy primer + finishing ral blue 50001个热交换机、缓清洗管和集水池的钢结构支撑,碳钢刷环氧底漆+面漆,劳尔 色卡蓝色 5000 (ralblue 5000)1 fresh air collector to the inlet recirculation fans1个连接循环风机进气口的净气收集器1 exhaust air collector from the recirculation fan to the exhaust fan inle

12、t1个排气收集器,连接循环风机和排气风扇进气口3 sets of ducting from the recirculation fans to the inlet of the dryer and from the outlet to the fan, including 3 by pass3组管道,连接循环风机和烘干机的进气口,以及烘干机的出气口与循环风机, 包括3个旁路1 exhaust chimney through the mezzanine roof1个穿过夹层屋顶的排气烟囱all ducting (not included wash down and catch basin) wi

13、ll be made of carbon steel thickness 2mm coated with aluminum thickness 300 microns (0.3mm) on each side, coating done after welding and finishing (cleaning, rust brushing .) application by thermally sprayed coating or aludip (option 1 with hot deep galvanized steel) air temperature maxi 200°c所

14、有管道(不包括缓清洗管和集水池)可选用碳钢材质,厚度2mm,双而涂铝 层,厚度300微米(0.3mm),焊接和精整(清洁、除锈等等)后再热喷涂铝 层,或者可选用aludip镀铝钢板(另一种可选材料为热浸镀锌板)。内部气体 最高温度200°co3/ part 2 一 top part (all fans are installed on the mezzanine floor at + 10.00 m)3、第2段一上段(所有风扇都装于夹层+ 10.00 m处)the part 2 is composed of第2段由以下部分构成:a/ equipment supplied and in

15、stalled by spoonera、spooner公司供货并已安装的设备- 5 dryer modules5个烘干机单体- 1 fresh air fan including filteri个净气风扇,带过滤器- 5 exhaust fans5个排气扇- 5 recirculation fans5个循环风机b/ equipment supplied by spooner but installed by the ducting companyb、spooner公司供货,但是需要风管供应商安装的设备- 5 exhaust dumpers 480x480mm5个排气风门,尺寸480x480mm

16、 5 fresh air dumpers 400x400mm5个净气风门,尺寸400x400mm- 5 recirculation inlet dumpers 1600x500mm to be fine tune with the connecting flange of the dryer (no bolts)5个循环进气风门,尺寸1600x500mm,需与烘干机连接法兰进行微调(无螺 栓)- 5 recirculation outlet dumpers 1100x1200mm5个循环排气风门,尺寸1100x1200mm- 5 by-pass dumpers 950x800mm5个旁通风门,

17、尺寸950x800mm- 1 heat exchanger1个热交换机- 5 heating batteries5个加热器-5 filters5个过滤器c/ equipment supplied and installed by the ducting companyc、风管供应商供货并安装的设备- 1 fresh air transition duct to the heat exchanger1个连接到热交换机的净气过渡导管- 1 exhaust air transition duct to the heat exchanger1个连接到热交换机的排气过渡导管- 1 pre heated

18、fresh air transition duct to the fresh air collector1个连接净气收集器的预热净气过渡导管- 1 wash down duct to the heat exchanger stainless steel 304l 3mm thk1个连接热交换机的缓清洗管,304l不锈钢,厚度3mm- 1 catch basin pan to the heat exchanger stainless steel 304l 3mm thk1个热交换机的集水池,304l不锈钢,厚度3mm1 steel structure support for exchanger

19、, wash down , and catch basin carbon steel epoxy primer + finishing ral blue 50001个热交换机、缓清洗管和集水池的钢结构支撑,碳钢刷环氧底漆+面漆,劳尔 色卡蓝色 5000 (ral blue 5000)- 1 fresh air collector to the inlet recirculation fans1个连接进气循环风机的净气收集器1 exhaust air collector from the recirculation fan to the exhaust fan inlet1个排气收集器,连接循环

20、风机和排气风扇进气口- 5 sets of ducting from the recirculation fans to the inlet of the dryer and from the outlet to the fan , including 5 by pass5纽管道,连接循环风机和烘干机的进气口口,以及烘干机的出气口与循环风 机,包括5个旁路 1 exhaust chimney through the mezzanine roof1个穿过夹层屋顶的排气烟囱 all ducting (not included wash down and catch basin) will be m

21、ade of carbon steel 2mm thick coated with aluminum thickness 300 microns on each side , coating done after welding and finishing (cleaning , rust brushing )application by thermally sprayed coating or aludip (option 1 with hot deep galvanized steel) air temperature maxi 200°c所有管道(不包括缓清管和集水池)可选用碳

22、钢材质,厚度2nwi,双面涂铝 层,厚度300微米(0.3mm),焊接和精整(清洁、除锈等等)后再热喷涂铝 层,或者可选用aludip镀铝钢板(另一种可选材料为热浸镀锌板)。内部气体 最高温度200°co4/ part 3 一 bottom part (all fans are installed on the machine floor at + 5.00 m)4、第3段一下段(所有风扇都装于纸机层+ 5.00 m处)the part 3 is composed of第3段由以下部分构成:a/ equipment supplied and installed by spoonera

23、> spooner公司供货并已安装的设备-5 dryer modules5个烘干机单体- 1 fresh air fan including filter1个净气风扇,带过滤器 5 exhaust fans5个排气扇 5 recirculation fans5个循环风机b/ equipment supplied by spooner but installed by the ducting companyb、 spooner公司供货,但是需耍风管供应商安装的设备- 5 exhaust dumpers 430x430mm5个排气风门,尺寸430x430mm- 5 fresh air dum

24、pers 325x325mm5个净气风门,尺寸325x325mm- 5 recirculation inlet dumpers 1600x500mm to be fine tune with the connecting flange of the dryer (no bolts)5个循环进气风门,尺寸1600x500mm,需与烘干机连接法兰进行微调(无螺 栓)- 5 recirculation outlet dumpers 1100x1200mm5个循环排气风门,尺寸1100x1200mm- 5 by-pass dumpers 950x800mm5个旁通风门,尺寸950x800mm- 1 h

25、eat exchanger1个热交换机-5 heating batteries5个加热器 5 filters5个过滤器c/ equipment supplied and installed by the ducting companyc、风管供应商供货并安装的设备- 1 fresh air transition duct to the heat exchanger1个连接到热交换机的净气过渡导管 1 exhaust air transition duct to the heat exchanger1个连接到热交换机的排气过渡导管 1 pre heated fresh air transitio

26、n duct to the fresh air collector1个连接净气收集器的预热净气过渡导管 1 wash down duct to the heat exchanger stainless steel 304l 3mm thk1个连接热交换机的缓清洗管,304l不锈钢,厚度3mm 1 catch basin pan to the heat exchanger stainless steel 304l 3mm thk1个热交换机的集水池,304l不锈钢,厚度3mm- 1 steel structure support for exchanger , wash down , and c

27、atch basin carbon steel epoxy primer + finishing ral blue 50001个热交换机、缓清洗管和集水池的钢结构支撑,碳钢刷环氧底漆+面漆,劳尔 色卡蓝色 5000 (ral blue 5000)- 1 fresh air collector to the inlet recirculation fans1个连接进气循环风机的净气收集器 1 exhaust air collector from the recirculation fan to the exhaust fan inlet1个排气收集器,连接循环风机和排气风扇进气口 5 sets

28、of ducting from the recirculation fans to the inlet of the dryer and from the outlet to the fan、including 5 by pass5组管道,连接循环风机和烘干机的进气口口,以及烘干机的出气口与循环风 机,包括5个旁路- 1 exhaust ducting connected to the exhaust chimney of zone 2, passing through the floor at + 10.00m 1个连接第2段排气烟囱的排气管道,穿过+ 10.00m处楼层all ducting (not included wash down and catch basin) will be made of carbon steel 2mm thick coated with aluminum thickness 300 microns on each side,coating done after welding and finishing (cleaning , rust brushing )application by thermally sprayed coating or aludip (option 1 w

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论