1、 毕业设计说明书(英文翻译)fire alarm systemfire control work shall follow the policy of devoting major efforts into prevention and combining fire prevention with fire fighting, and shall adhere to the principle of combining the efforts of both specialized organizations and the masses and carry out responsibilit
2、y system on fire prevention and safety. the state council shall led and the peoples governments at all levels be responsible for fire control work. the peoples government at all levels shall bring fire control work in line with the national economy and social development plan, and ensure that fire c
3、ontrol work fit in with the economic construction and social development. the public security department of the state council shall monitor and administer the nationwide fire control work; the public security organs of local peoples governments above county level shall monitor and administer the fir
4、e control work within their administrative region and the fire control institutions of public security organs of the peoples government at the same level shall be responsible for the implementation. along with the our country economic development rapid development, the lives of the people level unce
5、asing enhancement, the city uses to be day by day anxious, urges the building to face the direction is developing. this kind of high level civil construction repair needed materials and the way also more hasten the diversification, and along with uses electricity the load and coal gas consumption qu
6、antity enlarging, proposed to the fire auto-alarm system design is higher, a stricter request. in order to guarantee the people life and property the security, the fire auto-alarm system design has become in the high level civil construction design one of most important design contents. presently ba
7、sed on the author fire of auto-alarm system design overseeing work in the high level civil building experience, proposed in present national related standard and standard unclear true detail shallow opinion, by for the colleagues to discuss and to point out mistakes.automatic fire alarm system is by
8、 the trigger devices, fire alarm, fire alarm devices and other auxiliary functions of the device with the composition of the fire alarm system, automatic fire alarm system, automatic or manual fire alarm signal devices generate called trigger parts include fire detectors and manual fire alarm button
9、. fire detector fire detectors are sensing automatic fire alarm system parts, is composed of a variety of automatic fire alarm system, key components, automatic fire alarm system is a sense organ. it on the fire parameters (smoke, temperature, flame radiation, gas concentration, etc.) response, and
10、automatically generate a fire alarm signal, or to the control and indicating equipment status signals sent on-site fire equipment. fire detector is a key component in the system, his stability, reliability and sensitivity specifications are subject to many factors, so the selection and arrangement o
11、f fire detectors should be carried out strictly in accordance with specifications. classification of fire detectors currently many different types of fire detectors, there are different ways according to different classifications. 1 according to the monitoring of different fire characteristics, fire
12、 detectors can be divided into smoke, temperature, light-sensitive, complex and combustible gases such as five types, each type has its work according to different principles are divided into several. automatic reset fire detectors. can automatically return to monitoring status. remote reset fire de
13、tectors. through the remote control back to the surveillance state. manual reset fire detectors. by manually adjusting back to the surveillance state. can not reset the fire detectors. fire alarm signal in the production of the conditions no longer exist, the group can be swapped back to the monitor
14、 from the alarm state after state, or action can not be restored to the surveillance state. the choice of fire detector the choice of fire detector shall meet the following requirements: (1)early stages of the fire smoldering phase, generate a lot of smoke and a small amount of heat, little or no fl
15、ame radiation, smoke probe selection; (2) the fire developed rapidly, resulting in a lot of heat, smoke and flame radiation, smoke used probe, temperature probe, the flame sensor or a combination; (3) the fire developed rapidly, with a strong flame radiation and a small amount of smoke, heat, and us
16、e flame probe; (4)complicated or unexpected formation characteristics of fire can be simulated to fit the experimental probe used. fire alarm control fire alarm control is the heart of automatic fire alarm system has the following functions:(1) to accept the fire signal and start the fire alarms. th
17、e device can also be used to indicate fire location and recording the information. (2) start a fire through a fire alarm signal transmitting device, or through the automatic control unit activates the automatic fire extinguishing equipment and fire fighting linkage controller. (3) automatically moni
18、toring system for correct operation and failure to say anything specific, light alarm. fire alarm control classification wide variety of fire alarm controller, according to different methods can be divided into different categories. the control can be divided into: regional fire alarm control: direc
19、t connection of fire detectors, handling all kinds of alarm information. concentrated fire alarm control: it is generally not connected with the fire detector, which is connected with the regional fire alarm controller, fire alarm control of district-level alarm signal sent, often used in larger sys
20、tems. control center fire alarm control: it is both regional, centralized two or fire alarm feature of the controller, which can be used for the regional level, the connection controller; they can be used for concentration levels used to connect regional fire alarm controller. by structure type can
21、be divided into: wall of fire alarm control: connect the detector circuit corresponding less, control is simple, many regional police only use this type of controller.desktop fire alarm control: a few more connections detector circuit, linkage control more complex, centralized alarm often used this
22、way. box type fire alarm control: multi-loop connection can be realized with sophisticated control linkage. the system wiring is divided into: multi-wire fire alarm control: detector and controller correspond to the connection method used. b system, fire alarm control: the controller and the detecto
23、r connected by bus, detectors parallel or series on the bus. fire alarm control functions fire alarm: when you receive the detector, manual alarm switch, fire hydrant switch and input module is connected with the equipment issued to the fire signal, the alarm may be in alarm. failure alarm: the syst
24、em time-sharing running control inspection, if an exception (equipment failure) the issue of sound, light alarm signal and displays the fault type and encoding. fire priority: the failure to deal with fire alarm or, if the fire was reported the fire, and when the fire reportedly cleared automaticall
25、y after the original failure. the time clock and the memory of the fire: when the system clock to go through the software programming, with a corresponding memory cell, memory, time of the accident. self-test function: in order to improve the reliability of alarm systems, the controller sets the che
26、cking can be regular or irregular inspections of fire-first, design basisthe fire auto-alarm system design is a specialized very strong technology work, at the same time also has the very strong policy-type. therefore, first should be clear about the following design basis:1st, must grasp the archit
27、ectural design fire protection standard, the system design standard, the equipment manufacture standard, the installment construction approval standard and the administration laws and regulations and so on five big aspects fire laws and regulations, and in practical understanding present country rel
28、ated standard and standard positive word: must, be supposed, to be suitable, may and the reverse side word: strictly prohibits, should not, not have, not to be suitable the meaning.2nd, must aim at high level civil building function, use and the protection object fire protection rank, earnestly carr
29、ies out the present national related standard, earnestly treats the public security fire prevention surveillance department the examination and approval opinion.second, fire auto-alarm system equipment establishmentfire detector establishmentopens wide either the seal or the stair hall should alone
30、divide the search coverage.room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against the front room which smoke stair hall comes in handy) and the aisle should distinguish alone to divide the search coverage, specially front t
31、he room and the lift well, the scattered stair hall and the aisle are interlinked, has time the fire haze to be easier to gather or to flow, is the personnel disperses which saves goal with the fire prevention, therefore should install the fire detector. regarding common elevator in front of room al
32、though is not the personnel disperses , but this front room and the lift well are interlinked, has time the fire haze to be also easy to gather or to flow, suitably alone divides the search coverage and installs the fire detector.the electric cable shaft therefore is easy to form pulls out the smoke
33、 inflammation the channel; has when the fire the fire intensity not easily extends along the electric cable burns, for this, the high level civil construction design fire protection standard and the civil construction electricity design standard separately proposes the detailed specific stipulation
34、in the construction and in the electric wire or on the electric cable shaping. but considered implements specifically the difficulty and the present situation, the electric cable shaft installs the fire detector is extremely essential, and coordinates the shaft the fire protection separation request
35、, each 2 3 or each level installs.the elevator machine room should install the fire detector, its elevator is the important vertical transportation vehicle. when has the fire, the lift well often becomes the fire intensity spread the channel, is easy to threaten the elevator machine room the facilit
36、y. therefore, the elevator machine room establishes the fire detector is necessary, crown of also suitable establishment fire detector lift well.2nd, the manual fire reports to the police the button establishmentroom (including guards against in front of smoke stair hall in view of various floors fr
37、ont room in front of room, fire elevator room, fire elevator with guards against which smoke stair hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, should report to the police the button first choice spot as the establishment
38、 manual fire. in addition, the room also should establish the manual fire to the common elevator in front of to report to the police the button.in the public active place (including hall, dining room, multi-purpose hall and so on) and the main thoroughfare and so on place, the personnel very is all
39、centralized, and mainly disperses the channel. therefore should report to the police the button in these public active places main access establishment manual fires; the manual fire establishes which in the main thoroughfare reports to the police the button to guarantee to a manual fire which most i
40、s close to reports to the police the button distance from a fire protection district any position not to be supposed to be bigger than 30 meters.3rd, the fire emergency broadcasts the speaker the establishmentthe aisle, the hall, the dining room and so on the public place personnel very are all cent
41、ralized, and mainly disperses the channel. therefore should press in these public places to a recent speaker distance is not bigger than 25 meters from a fire protection district any spot and in the aisle last should not be bigger than 12.5 meters the speaker to the aisle terminal distance the estab
42、lishment fire emergency to broadcast the speaker; next also should establish the fire in the public bathroom place emergency to broadcast the speaker.room (including guards against in front of smoke stair hall in front of room, fire elevator room, fire elevator with guards against which smoke stair
43、hall to come in handy the front room) is has when the fire the personnel to disperse which saves goal with fire prevention, also has the fire door separation and the sounds of people is confused and noisy, therefore should establish the fire emergency to broadcast the speaker. in front of the common
44、 elevator the room also should establish the fire emergency to broadcast the speaker. disperses the stair hall also is has when the fire the personnel to disperse which saves goal with the fire prevention, also the sounds of people are confused and noisy, therefore should establish the fire emergenc
45、y to broadcast the speaker, by favors the fire emergency broadcast to disperse the instruction.4th, fire alarm installment establishmentthe establishment fire emergency broadcast fire auto-alarm system, the author thought also should install the fire alarm installment, but its control procedure shou
46、ld be: the alarm apparatus should confirm after the fire, uses manual or the automatic control mode unification to the fire correlation region transmission warning, stops the alarm apparatus work in the stipulation time, the rapid linkage fire emergency broadcast and broadcasts to the people dispers
47、es the instruction.the fire alarm establishment position, the author thought should report to the police the button position w installment ith the manual fire to be same, its wall surface installment should for be apart from the ground 1.8 meters highly5th, fire special use telephone establishmentin
48、stalls the fire special use telephone extension telephone, should be located the engine room which related also some people is on duty frequently with the fire linkage control (including fire water plant, spare electricity generation engine room, matches substation, mainly ventilates with air condit
49、ioning engine room, discharges fume engine room, fire prevention elevator machine room and other), the fire fighting control system operates the equipment place or the control room, the fire duty officers observation room, the security manages spot and so on public room. in the fire elevator and the
50、 ordinary elevator all should suppose the special use telephone, requests the elevatorm achine room and the elevator sedan theater box, the elevator machine room and the fire control room, the elevator sedan theater box and the fire control room and so on three compositions is reliable to speaks the
51、 correspondence telephone system. usually in fire control room; the establishment elevator monitoring demonstration plate (including position indicator, direction indicating lamp, to speaks correspondence telephone, trouble lamp and so on), in order to carries on the necessity to the elevator runnin
52、g status which in the surveillance and the emergency case controls.is equipped with the manual fire to report to the police position and so on button, fire hydrant button also should install the fire special use telephone receptacle.third, fire linkage control1st, the fire linkage control should inc
53、lude the control fire pump to open, to stop, also should demonstrate opens pumps the button the position and the fire pump work and the malfunction. when the fire hydrant is equipped with the fire hydrant button, its electric installation work spot also should demonstrate the fire pump the working m
54、ode active status (namely establishment fire pump work indicating lamp).2nd, the fire linkage control should include the control spraying of water and the water atomization fire fighting system opens, stops, also should demonstrate the fire pump the work and the malfunction and the fluent display, r
55、eports to the police the valve, the safety signal valve working mode active status. in addition, to the basin, the water tank water level also should carry on the demonstration monitor; in order to prevent the overhaul signal valve is shut down, the author thought should use the belt electric signal
56、 the control signal valve by to demonstrate it opens the condition.3rd, the fire linkage control other controls and the demonstration function, should carry out the present national related standard and the standard specific stipulation.fourth, fire auto-alarm system wiringin order to prevent the fi
57、re occurs when the fire control, the correspondence and the warning line severance, causes the fire fighting work to be unable to carry on, creates the bigger economic loss; also for the suppression electronmagetic interference (for example transformer, electric motor, electric cable and so on) the
58、influence which produces to the fire auto-alarm system. the fire auto-alarm system transmission line and the fire control, the correspondence and the warning line should use the being flame-resistant electric cable, and should use the metal tube or the enclosed metal trunking protection. the fire ma
59、nual positive governing installment line should use the fireproof electric cable, its electric cable also should use the metal tube or the enclosed metal trunking protection. uses ming fushi, should takes the fire protection protective measures on the metal tube or the enclosed metal trunking.fifth, concluding remark the author r
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 小学五年级数学小数乘除法竖式计算练习题
- 土方分包合同范本-合同范本
- 《美容项目专业知识》课件
- 《医院急诊科的管理》课件
- 届每日语文试题精练
- 更新采伐公路护路林许可申请表
- 《家用医疗用具使用》课件
- 金融产业电话理财顾问绩效总结
- 快递公司保安工作总结
- 医疗器械行业安全工作总结
- ASTM-A269-A269M无缝和焊接奥氏体不锈钢管
- 中、高级钳工训练图纸
- 2024-2030年中国车载动态称重行业投融资规模与发展态势展望研究报告
- 乒乓球教案完整版本
- 2024年重庆公交车从业资格证考试题库
- 银行解押合同范本
- 2024-2030年中国纹身针行业市场发展趋势与前景展望战略分析报告
- 部编版道德与法治九年级上册每课教学反思
- 2024云南保山电力股份限公司招聘(100人)(高频重点提升专题训练)共500题附带答案详解
- 人教版(2024)七年级上册英语 Unit 1 You and Me 语法知识点复习提纲与学情评估测试卷汇编(含答案)
- 六年级期末家长会课件下载
评论
0/150
提交评论