1、CFX-PreBoundary Conditions,Lecture 4,Boundary Condition Types,Required on all regions at the outer extremities of the domain to be simulated (bound the problem) There are 5 basic flow boundary conditions,Inlet,Opening,Outlet,Wall,Symmetry,as shown earlier,How to Create a Boundary Condition,Defining
2、a Boundary ConditionBasic Settings,Boundary Type Inlet, Outlet, Opening, Wall, Symmetry Location select from composite regions in drop down menu or from all 2D primitives by clicking Coord Frame if more than one exists, select the appropriate frame Frame Type available only in a rotating domain. All
3、ows you to specify quantities based on a rotating or stationary (absolute) frame of reference. Profile Boundary Conditions Discussed in upcoming slides,Inlet Velocity Components-Static Temperature (Heat Transfer) Normal Speed-Total Temperature (Heat Transfer) Mass Flow Rate-Total Enthalpy (Heat Tran
4、sfer) Total Pressure (stable)-Relative Static Pressure (Supersonic) Static Pressure-Inlet Turbulent conditions Outlet Average Static Pressure-Normal Speed Velocity Components-Mass Flow Rate Static Pressure Opening Opening Pressure and Direction-Opening Temperature (Heat Transfer) Opening Pressure (E
5、ntrainment)-Opening Static Temperature (Heat Transfer) Static Pressure and Direction-Inflow Turbulent conditions Static Pressure (Entrainment) Velocity Components Wall No Slip / Free Slip-Adiabatic (Heat Transfer) Roughness Parameters-Fixed Temperature (Heat Transfer) Heat Flux (Heat Transfer)-Heat
6、Transfer Coefficient (Heat Transfer) Symmetry No details (only specify region which corresponds to the symmetry plane,Covered in Theory Section at end of lecture,Defining a Boundary ConditionBoundary Details,Boundary ConditionsSpecifying Well Posed Boundary Conditions,The boundary settings have a st
7、rong effect on the convergence rate and on the accuracy of the results,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Inflow (Inlet) Inlet normal velocity 50 m/s Outflow (Outlet) static pressure 0 Pa,Mass flow,Mass flow,Inflow (Inlet) Inlet normal velocity 50 m/s Outflow (Opening) Aver
8、age pressure 0 Pa,Example 1,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Mass flow diverges,Outlet,Mass flow,Fast convergence of mass flow,restart,Inflow (Inlet) Inlet normal velocity 25 m/s Outflow (Outlet) Static Pressure,Inflow (Inlet) Static Pressure Outflow (Opening) Static Pres
9、sure,Example 2,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Do not set boundary conditions that over-specify or under specify the problem Over Specifying Not giving the solver the freedom to approach the correct answer Difficulty converging Under Specifying Not giving the solver enou
10、gh information to calculate values Non physical solution,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Example,Governing Equations 1) Mass conservation 2) X-momentum conservation,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Example,Case 1: Incompressible Fluid 1) Mass
11、conservation IMPOSSIBLE CRASH 2) X-momentum conservation,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Example,Case 2: Compressible Fluid 1) Mass conservation OVER-SPECIFIED 2) X-momentum conservation UNDER-SPECIFIED,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Example
12、,Case 3: Most Robust Setting 1) Mass conservation WELL DEFINED 2) X-momentum conservation WELL DEFINED,or,5 kg/s,Pstatic = 150 kPa,5 m/s,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Recommended Configurations Most Robust: Velocity/Mass Flow at an Inlet; Static Pressure at an Outlet.
13、The Inlet total pressure is an implicit result of the prediction. Robust: Total Pressure at an Inlet; Velocity/Mass Flow at an Outlet. The static pressure at the Outlet and the velocity at the Inlet are part of the solution. Sensitive to Initial Guess: Total Pressure at an Inlet; Static Pressure at
14、an Outlet. The system mass flow is part of the solution Very Unreliable: Static Pressure at an Inlet; Static Pressure at an Outlet. This combination is not recommended, as the inlet total pressure level and the mass flow are both an implicit result of the prediction (the boundary condition combinati
15、on is a very weak constraint on the system,Boundary ConditionsSpecifying Well Posed Boundary Conditions,From the numerical point of view, it is often very useful to extend the location of inlets and/or outlets,Use care; symmetric geometry does not necessarily mean symmetric flow Example: The coanda
16、effect. A jet entering at the center of a symmetrical duct will tend to flow along one side above a certain certain Reynolds number,No Symmetry Plane,Symmetry Plane,Boundary ConditionsSpecifying Well Posed Boundary Conditions,Boundary ConditionsKey Points,Specify boundary conditions that define but
17、do not over-specify the problem Choose the domain bounds which allow for the most accurate boundary conditions,Boundary Conditions Theory,Inlet Turbulence Conditions,Unless turbulence is being simulated, it is accounted for by modeling the transport of turbulence properties for example k and (Domain
18、s Theory) Similar to momentum and mass, turbulence variables require boundary condition specifications,Inlet Turbulence Conditions,Several options exist for the specification of turbulence quantities at inlets (details on next slide) Unless you have absolutely no idea of the turbulence levels in you
19、r simulation (in which case, you can use the Medium (Intensity = 5%) option), you should use well chosen values of turbulence intensities and length scales Nominal turbulence intensities range from 1% to 5% but will depend on your specific application The default turbulence intensity value of 0.037
20、(that is, 3.7%) is sufficient for nominal turbulence through a circular inlet, and is a good estimate in the absence of experimental data,Inlet Turbulence Conditions,Default Intensity and Autocompute Length Scale The default turbulence intensity of 0.037 (3.7%) is used together with a computed lengt
21、h scale to approximate inlet values of k and . The length scale is calculated to take into account varying levels of turbulence. In general, the autocomputed length scale is not suitable for external flows. Intensity and Autocompute Length Scale This option allows you to specify a value of turbulenc
22、e intensity but the length scale is still automatically computed. The allowable range of turbulence intensities is restricted to 0.1%-10.0% to correspond to very low and very high levels of turbulence accordingly. In general, the autocomputed length scale is not suitable for external flows. Intensity and
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 19.3 课题学习 选择方案课件
- 城市公共厕所建设方案
- 施工现场标识与指示系统方案
- 防火隔离带施工方案
- 《腹腔镜胆囊癌根治性切除专家共识(2023)》解读
- 砌体工程施工团队绩效管理方案
- 桥梁设计标准化研究
- 《Unity引擎》-第11章教学材料
- 质量控制技术组织措施课件
- 《aoouiu》课件语文一年级上册统编版
- 高标准农田建设培训课件
- 体检中心收费与财务一体化管理方案
- 解答题 概率与统计(专项训练12大题型+高分必刷)(原卷版)2026年高考数学一轮复习讲练测
- 2024-2025学年北京市海淀区第二十中学高二上学期期末物理试题(含答案)
- 金属加工工艺规划
- 四川省内江市2024-2025学年高二上学期期末检测化学试题
- 送你一朵小红花评语
- 广东省深圳市龙岗区2024-2025学年二年级上学期学科素养期末综合数学试卷(含答案)
- 临床成人吞咽障碍患者口服给药护理
- (16)普通高中体育与健康课程标准日常修订版(2017年版2025年修订)
- 2025至2030中国IT培训行业项目调研及市场前景预测评估报告
评论
0/150
提交评论