全文预览已结束
下载本文档
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
Page 5of 5Understand ControlLogix Redundancy Memory UsageCreation Date:6-30-04DISCLAIMERBecause of the variety of uses for this information, the user of and those responsible for applying this information must satisfy themselves as to the acceptability of each application and use of the program. In no event will Allen-Bradley Company be responsible or liable for indirect or consequential damages resulting from the use or application of this information.The illustrations, charts and examples shown in this application note are intended solely to illustrate the principles of programmable controllers and some of the methods used to apply them. Particularly because of the many variables and requirements associated with any particular installation, Allen-Bradley Company cannot assume responsibility or liability for actual use based upon the illustrations used and applications.Allen-Bradley Company assumes no patent liability with respect to use of information, circuits, equipment, or software described in this text.Reproduction of the contents of the application note, in whole or in part, without the express written consent of the Allen-Bradley Company is prohibited.Document Purpose This document is not a manual or training material, but an Application Note, which could be useful in helping a Rockwell Automation customer with understanding ControlLogix Redundancy memory usage.Intended AudienceThis document is to be used by Rockwell Automation employees/customers supporting and selling ControlLogix Redundancy.Concept of Application NoteIn a ControlLogix controller (L55 and L6X) there are two separate areas of memory, I/O memory and data and logic memory. When Redundancy is enabled, certain areas of memory will approximately double in usage; those are I/O memory and data memory. We will discuss why these areas of memory double.First let us look at an example using an L55M13 to illustrate:Non-Redundant System:I/O memory:Total 208 KbytesUsed 75 KbytesData and Logic memory:Total 1.5 MegUsed 250 Kbytes data and 250 Kbytes logicNow when Redundancy is enabled the amount of I/O memory and data memory will double.Redundant System:I/O memory:Total 208 KbytesUsed 125 KbytesData and Logic memory:Total 1.5 MegUsed 500 Kbytes data and 250 Kbytes logicAnother example of the I/O and data memory doubling can also be shown by using V13 software and the offline memory estimation tool.First we will look at the memory estimation of a blank non-redundant controller. That is no I/O, data, or logic. This is only an estimation.BaselineThe figure above will give us a baseline from which to work. There is some memory used even if the controller program is empty.Now we will add some I/O to the program. The following I/O was added.Redundancy not enabled:Figure 1Redundancy enabled:Figure 2By subtracting the Max Used bytes under Estimated I/O Memory from figures Baseline and 1 you can see that 2256 bytes were added to memory. Then by subtracting the Max Used bytes under Estimated I/O Memory from figures Baseline and 2 you can see that 4176 bytes were added to memory, approximately double the size.Now we will now add a 10,000 element DINT array to the program.Redundancy not enabled:Figure 3Redundancy enabled:Figure 4By subtracting the Max Used bytes under Estimated Data and Logic Memory from figures 1 and 3 you can see that 39880 bytes were added to memory, approximately the size of the 10,000 element DINT array. Then by subtracting the Max Used bytes under Estimated Data and Logic Memory from figures 2 and 4 you can see that 80108 bytes were added to memory, approximately double the size of the 10,000 element dint array.The two examples above confirm that I/O and data memory are approximately doubled when redundancy is enabled. The question that comes out of all this is why is I/O and Data memory usage double when redundancy is enabled? Each section of memory will be addressed separately.Why is I/O memory doubled? Simply to have bumpless outputs for the highest priority user task. Another way to say this is it prevents a momentary reversal of outputs immediately after a switchover for outputs of the high priority user task. The basic objective of the output handling approach in the redundant Logix Controller is to ensure that no data is sent to the output modules from the primary Logix controller without the secondary Logix controller having the same values in its output image. This is accomplished via an output buffering mechanism.There are two copies of the output image:1. Program Output Image2. Output Transmit ImageThe Program Output Image (POI) is the copy of the outputs that are directly accessed by the user program. All instructions, both output (write) instructions and input (read) instructions which reference output data values, will use the POI. The second buffer, the Output Transmit Image (OTI), is the copy of the outputs that are actually sent to the output modules. If there is a qualified secondary controller in the system, then the changes in the primary controllers POI are first sent to the secondary controller. The OTI in the primary is not updated with the POIs data until the secondary controller acknowledges that it has received the data and moved the data to its own OTI. If there is no secondary controller present the data will be copied from the POI to the OTI at the end of every program.So because of the creation of the POI we double the amount of I/O memory. But you may ask youve only talked about “outputs” what about “inputs”. If outputs are the only I/O that need to be buffered then my I/O memory should only increase by the amount used for outputs. Yes that is true, but for increased performance it is easier and faster to make an exact copy of I/O memory. Then when data is moved from the POI to the OTI we only have to use a constant offset. Again, the pay off is performance over increased memory usage.Why is the data table memory doubled? As the primary contr
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- T/CEPCA 1010-2024电力建设工程绿色建造评价
- T/BDSAA 0002-2025北斗独立定位导航终端测试方法
- T/BFIA 020-2023金融数据资源目录编制指南
- 医院肿瘤护理小组工作计划(2篇)
- 《随类赋彩》教学设计-2026-2027学年沪教版(新教材)初中美术七年级上册
- 西烹基础知识试题与答案解析
- 关于全面推进全国基础教育阶段统一教材建设的社情民意信息
- T/CAPT 004-2022机器生产内容自动化分级
- 2026年秋招:福建医药集团面试题及答案
- 2026年秋招:东莞水务集团试题及答案
- 2026中国安宁疗护服务需求增长与供给缺口测算分析报告
- 2026秋小学岭南版美术六年级上册(新教材)教学计划附教学进度表
- 小学一年级语文上册《天地人》单元整体教学教案
- 2026年电梯高级工特种作业考试题库(附含答案)
- 第2课 《中国人首次进入自己的空间站》课件(内嵌视频)2026-2027学年统编版语文八年级上册
- 初级焊工理论考试题及答案
- 2026年阿里云ACP云计算工程师认证考试真题题库
- S224颍上至赛涧段道路工程K6~K9初步设计
- 物业公司与理发店合同
- 2026年4月自考02323操作系统概论试题及答案含评分参考
- 工程复工报告(完整版)
评论
0/150
提交评论