分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第1页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
,,,,,,,,,,,,,
,C.4.4,,控制设备及低压电器安装,,,,,,,,,,
1,030404034001,,开关及按钮扳把开关明装,,1.名称:风扇电阻开关,个,,254,,"26,54",,"6741,16",
2,030404035001,,三相带接地明插座(15A以下),,1.规格:带保护接点暗装插座,个,,21,,"38,01",,"798,21",
3,030404035002,,三相带接地明插座(15A以下),,1.规格:单相二三眼安全型插座,个,,64,,"37,14",,"2376,96",
,,,分部小计,,,,,,,,,"9916,33",
,C.4.8,,电缆安装,,,,,,,,,,
4,030408001001,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:BYJF-3*10,m,,"25,16185",,"12,75",,"320,81",
5,030408001002,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:BYJF-3*16,m,,"51,8345",,"17,6",,"912,29",
6,030408001003,,铜芯电力电缆敷设电缆(截面35mm2以下),,1.规格:BYJF-3*6,m,,"2574,7084",,"10,09",,"25978,81",
7,030408001004,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:BYJF-5*10,m,,"24,30463",,"17,6",,"427,76",
8,030408001005,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:BYJF-5*16,m,,"31,97219",,"17,6",,"562,71",
9,030408001006,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:WDZN-YJFE-4*25+1*16,m,,"19,89165",,"17,6",,"350,09",
10,030408001007,,铜芯电力电缆敷设电缆(截面240mm2以下),,1.规格:WDZN-YJFE-4*50+1*16,m,,"8,86892",,"26,26",,"232,9",
11,030408001008,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:WDZN-YJFE-4*95+1*50,m,,"14,68646",,"17,6",,"258,48",
12,030408001009,,电力电铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:WDZN-YJFE-5*16,m,,"13,27074",,"17,6",,"233,57",
13,030408001010,,铜芯电力电缆敷设电缆(截,,1.规格:WDZ-YJFE-4*120+1*70,m,,"9,7334",,"42,31",,"411,82",
本页小计,,,,,,,,,,,,"39605,57",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第2页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
,,,面400mm2以下),,,,,,,,,,
14,030408001011,,铜芯电力电缆敷设电缆(截面400mm2以下),,1.规格:WDZ-YJFE-4*70+1*35,m,,"21,25202",,"42,31",,"899,17",
15,030408001012,,铜芯电力电缆敷设电缆(截面400mm2以下),,1.规格:WDZ-YJFE-4*120+1*70,m,,"239,59515",,"42,31",,"10137,27",
16,030408001013,,铜芯电力电缆敷设电缆(截面35mm2以下),,1.规格:BYJF-3*10,m,,"38,04672",,"10,09",,"383,89",
17,030408001014,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:BYJF-3*16,m,,"99,252",,"17,6",,"1746,84",
18,030408001015,,铜芯电力电缆敷设电缆(截面35mm2以下),,1.规格:BYJF-3*6,m,,"5437,7043",,"10,09",,"54866,44",
19,030408001016,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:BYJF-5*10,m,,"11,97027",,"17,6",,"210,68",
20,030408001017,,铜芯电力电缆敷设电缆(截面35mm2以下),,,m,,"40,39052",,"10,09",,"407,54",
21,030408001018,,铜芯电力电缆敷设电缆(截面240mm2以下),,1.规格:WDZN-YJFE-4*25+1*16,m,,"229,63943",,"26,26",,"6030,33",
22,030408001019,,铜芯电力电缆敷设电缆(截面240mm2以下),,1.规格:WDZN-YJFE-4*50+1*16,m,,"122,60038",,"26,26",,"3219,49",
23,030408001020,,铜芯电力电缆敷设电缆(截面400mm2以下),,1.规格:WDZN-YJFE-4*95+1*50,m,,"59,04383",,"42,31",,"2498,14",
24,030408001021,,铜芯电力电缆敷设电缆(截面400mm2以下),,1.规格:WDZ-YJFE-4*120+1*70,m,,"112,78227",,"42,31",,"4771,82",
25,030408001022,,铜芯电力电缆敷设电缆(截面120mm2以下),,1.规格:WDZN-YJFE-5*16,m,,"81,00796",,"17,6",,"1425,74",
26,030408001023,,铜芯电力电缆敷设电缆(截面400mm2以下),,1.规格:WDZ-YJFE-4*70+1*35,m,,"136,83393",,"42,31",,"5789,44",
27,030408003001,,电缆保护管明敷塑料管(公称,,"1.名称:7CC-WL1
2.材质:硬质聚氯乙",m,,"111,76619",,"52,38",,"5854,31",
本页小计,,,,,,,,,,,,"98241,1",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第3页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
,,,直径100mm以下),,"烯管
3.规格:20",,,,,,,,
28,030408003002,,电缆保护管明敷塑料管(公称直径100mm以下),,"1.名称:7CC-WL2
2.材质:硬质聚氯乙烯管
3.规格:20",m,,"121,98517",,"52,38",,"6389,58",
,,,分部小计,,,,,,,,,"134319,92",
,C.4.11,,配管、配线,,,,,,,,,,
29,030411001001,,配管,,"1.材质:PE
2.规格:11",m,,"15,94809",,"6,26",,"99,84",
30,030411001002,,配管,,"1.材质:PE
2.规格:20",m,,"35,5104",,"14,66",,"520,58",
31,030411001003,,配管,,"1.材质:SC
2.规格:20",m,,"6323,25137",,"14,66",,"92698,87",
32,030411001004,,镀锌电线管砖、混凝土结构明配公称直径(20mm以内),,"1.材质:SC
2.规格:20",m,,"48,75625",,"14,66",,"714,77",
33,030411001005,,镀锌电线管砖、混凝土结构明配公称直径(20mm以内),,"1.材质:SC
2.规格:20",m,,"521,80887",,"14,66",,"7649,72",
34,030411003001,,钢制槽式桥架(宽+高400mm以下),,"1.名称:QJ-1
2.型号:200*100
3.规格:200*100
4.材质:钢制桥架",m,,"776,11821",,"262,54",,"203762,07",
35,030411003002,,钢制槽式桥架(宽+高800mm以下),,"1.名称:QJ-2
2.型号:600*150
3.规格:600*150
4.材质:钢制桥架",m,,"47,5",,"284,25",,"13501,88",
36,030411003003,,桥架,,"1.名称:QJ-3
2.型号:50*50
3.规格:50*50
4.材质:钢制桥架",m,,"113,28902",,"191,73",,"21720,9",
37,030411003004,,钢制槽式桥架(宽+高400mm以下),,"1.名称:QJ-4
2.型号:100*100
3.规格:100*100
4.材质:钢制桥架",m,,"28,92385",,"205,94",,"5956,58",
38,030411003005,,钢制槽式桥架(宽+高1000mm以下),,"1.名称:QJ-5
2.型号:800*150
3.规格:800*150
4.材质:钢制桥架",m,,"76,23319",,"307,06",,"23408,16",
本页小计,,,,,,,,,,,,"376422,95",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第4页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
39,030411004001,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:BYJF-2.5,m,,"449,99724",,,,,
40,030411004002,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:BYJF-2.5,m,,"1586,4265",,"1,22",,"1935,44",
41,030411004003,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:KV-BV-2.5,m,,"6255,47563",,"1,22",,"7631,68",
42,030411004004,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:KV-ZRBV-2.5,m,,"414,2248",,"1,22",,"505,35",
43,030411004005,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:NH-BV-2.5,m,,"9263,26429",,"1,22",,"11301,18",
44,030411004006,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:NHBVV-2.5,m,,"95,03816",,"1,22",,"115,95",
45,030411004007,,管内穿线动力线路(铜芯)导线截面(10mm2以内),,1.规格:WDZN-YJFE-10,m,,"100,99043",,"1,17",,"118,16",
46,030411004008,,管内穿线照明线路(铜芯)导线截面(4mm2以内),,1.规格:WDZN-YJFE-4,m,,"61,0165",,"0,92",,"56,14",
47,030411004009,,管内穿线动力线路(铜芯)导线截面(6mm2以内),,1.规格:WDZN-YJFE-6,m,,"199,66051",,"0,99",,"197,66",
48,030411004010,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:ZR-BV-2.5,m,,"7433,47523",,"1,22",,"9068,84",
49,030411004011,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:ZRBVV-2.5,m,,"66,98056",,"1,22",,"81,72",
本页小计,,,,,,,,,,,,"31012,12",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第5页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
50,030411004012,,管内穿线照明线路(铜芯)导线截面(2.5mm2以内),,1.规格:BYJF-2.5,m,,"76,84383",,"1,22",,"93,75",
51,030411004013,,管内穿线动力线路(铜芯)导线截面(10mm2以内),,1.规格:WDZN-YJFE-10,m,,"74,03389",,"1,17",,"86,62",
52,030411004014,,管内穿线动力线路(铜芯)导线截面(6mm2以内),,1.规格:WDZN-YJFE-6,m,,"335,66462",,"0,99",,"332,31",
53,030411006001,,接线盒,,1.名称:接线盒暗装[联塑Φ20司令盒],个,,1375,,"9,46",,"13007,5",
,,,分部小计,,,,,,,,,"414565,67",
,C.4.12,,照明器具安装,,,,,,,,,,
54,030412005001,,标志、诱导装饰灯具墙壁式,,1.名称:安全出口灯,套,,64,,"120,98",,"7742,72",
55,030412005002,,标志、诱导装饰灯具墙壁式,,1.名称:层号灯,套,,27,,"120,98",,"3266,46",
56,030412005003,,成套型荧光灯具安装吸顶式单管,,1.名称:单管日光灯,套,,152,,"117,45",,"17852,4",
57,030412005004,,标志、诱导装饰灯具墙壁式,,1.名称:单向疏散指示灯,套,,79,,"120,98",,"9557,42",
58,030412005005,,密闭灯具安装防爆灯直杆式,,1.名称:防暴单管日光灯,套,,11,,"141,89",,"1560,79",
59,030412005006,,密闭灯具安装防爆灯直杆式,,1.名称:防暴吸顶灯,套,,1,,"141,89",,"141,89",
60,030412005007,,工厂灯及防水防尘灯安装防水防尘灯吸顶式,,1.名称:防水灯,套,,12,,"126,59",,"1519,08",
61,030412005008,,其他普通灯具座灯头,,1.名称:墙上座灯,套,,38,,"106,91",,"4062,58",
62,030412005009,,成套型荧光灯具安装吸顶式双管,,1.名称:双管日光灯,套,,34,,"123,11",,"4185,74",
63,030412005010,,标志、诱导装饰灯具吊杆式,,1.名称:双向疏散指示灯,套,,13,,"129,28",,"1680,64",
64,030412005011,,半圆球吸顶灯灯罩直径(350mm,,1.名称:天棚灯,套,,53,,"118,45",,"6277,85",
本页小计,,,,,,,,,,,,"71367,75",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第6页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
,,,以内)[半圆球节能吸顶灯]楼梯照明,,,,,,,,,,
65,030412005012,,自带电源事故照明灯,,1.名称:自带电源事故照明灯,套,,13,,"117,45",,"1526,85",
66,030412005013,,自带蓄电池的筒灯,,1.名称:自带蓄电池的筒灯,套,,144,,"117,45",,"16912,8",
67,030412005014,,自带蓄电池的吸顶灯,,1.名称:自带蓄电池的吸顶灯,套,,4,,"117,45",,"469,8",
,,,分部小计,,,,,,,,,"76757,02",
,C.7.1,,通风及空调设备及部件制作安装,,,,,,,,,,
68,030701004001,,风机盘管,,1.名称:风机盘管,台,,271,,"1797,2",,"487041,2",
,,,分部小计,,,,,,,,,"487041,2",
,D.8.1,,变配电设备工程,,,,,,,,,,
69,040801029001,,开关及按钮扳式暗开关(单控)单联,,1.规格:单极开关,个,,44,,"21,41",,"942,04",
70,040801029002,,开关及按钮扳式暗开关(双控)单联,,1.规格:双控开关,个,,50,,"26,98",,1349,
71,040801029003,,声控(红外线感应)延时开关,,1.规格:延迟开关,个,,71,,"16,34",,"1160,14",
72,040801029004,,开关及按钮扳式暗开关(单控)单联,,1.规格:钥匙开关,个,,3,,"26,43",,"79,29",
73,040801029005,,开关及按钮扳式暗开关(单控)单联,,1.规格:单联单控暗开关,个,,10,,"26,43",,"264,3",
74,040801029006,,开关及按钮扳式暗开关(单控)单联,,1.规格:防爆单极开关,个,,2,,"25,59",,"51,18",
,,,分部小计,,,,,,,,,"3845,95",
,D.8.3,,电缆工程,,,,,,,,,,
75,040803005011,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(35截面mm2,,1.名称:线缆端头BYJF-3*10,个,,4,,"222,88",,"891,52",
本页小计,,,,,,,,,,,,"510688,12",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第7页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
,,,以下),,,,,,,,,,
76,040803005012,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(35截面mm2以下),,1.名称:线缆端头BYJF-3*16,个,,8,,"222,88",,"1783,04",
77,040803005013,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(35截面mm2以下),,1.名称:线缆端头BYJF-3*6,个,,426,,"222,88",,"94946,88",
78,040803005014,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(120截面mm2以下),,1.名称:线缆端头BYJF-5*10,个,,4,,"425,56",,"1702,24",
79,040803005015,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(120截面mm2以下),,1.名称:线缆端头BYJF-5*16,个,,4,,"425,56",,"1702,24",
80,040803005016,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(240截面mm2以下),,1.名称:线缆端头WDZN-YJFE-4*25+1*16,个,,2,,"658,12",,"1316,24",
81,040803005017,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(240截面mm2以下),,1.名称:线缆端头WDZN-YJFE-4*50+1*16,个,,1,,"658,12",,"658,12",
82,040803005018,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(400截面mm2以下),,1.名称:线缆端头WDZN-YJFE-4*95+1*50,个,,2,,"1155,71",,"2311,42",
83,040803005019,,1kV以下户内,,1.名称:线缆端,个,,2,,"425,56",,"851,12",
本页小计,,,,,,,,,,,,"105271,3",
注:为计取规费等的使用,可在表中增设其中:“定额人工费”。,,,,,,,,,,,,,
,,,,,,,,,,,表—08,,
,,,,,,,,,,,,,
分部分项工程和单价措施项目清单与计价表,,,,,,,,,,,,,
工程名称:电气工程,,,,,,,标段:,,,,第8页共9页,,
序号,项目编码,,项目名称,,项目特征描述,计量单位,,工程量,,金额(元),,,
,,,,,,,,,,综合单价,,合价,其中
,,,,,,,,,,,,,暂估价
,,,浇注式铜芯电力电缆终端头制作、安装铜芯终端头(120截面mm2以下),,头WDZN-YJFE-5*16,,,,,,,,
84,040803005020,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(400截面mm2以下),,1.名称:线缆端头WDZ-YJFE-4*120+1*70,个,,1,,"1155,71",,"1155,71",
85,040803005021,,1kV以下户内浇注式铜芯电力电缆终端头制作、安装铜芯终端头(400截面mm2以下),,1.名称:线缆端头WDZ-YJFE-4*70+1*35,个,,3,,"1155,71",,"3467,13",
,,,分部小计,,,,,,,,,"110785,66",
,C.2.2,,C.2.2配电装置安装,,,,,,,,,,
86,030202017001,,低压成套配电柜,,1.规格:1000*1000*800,台,,4,,"14150,38",,"56601,52",
,,,分部小计,,,,,,,,,"56601,52",
,C.2.4,,C.2.4控制设备及低压电器安装,,,,,,,,,,
87,030204018003,,配电箱,,1.规格:1125*1000*450,台,,8,,"281,47",,"2251,76",
88,030204018004,,配电箱,,1.规格:750*1000*300,台,,249,,"281,47",,"70086,03",
,,,分部小计,,,,,,,,,"72337,79",
,,,分部小计,,,,,,,,,"1366171,06",
,,,分部小计,,,,,,,,,"1366171,06",
,,,措施项目,,,,,,,,,,
89,0313010
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 腮腺肿物护理问题
- 护理教育学翻转课堂
- 《新人培训证券分析》课件
- 《工程质量通病防治》课件
- 红十字会艾滋病日
- 网络安全管理中心
- 《道路勘测设计》课件-2-9道路的平面图识读
- 胰腺药物损伤治疗方案
- 社会活动中班垃圾分类
- 社会活动介绍我自己
- GB∕T 36655-2018 电子封装用球形二氧化硅微粉中α态晶体二氧化硅含量的测试方法
- 新部编(统编)人教版六年级上册语文期末复习全册分单元知识考点梳理
- 大马大马告诉我
- 电感耦合等离子体质谱仪分析(水质)原始记录
- 高考冲刺主题班会——勇往直前无畏风雨课件(17张PPT)
- 融优学堂人工智能(北京大学)章节测验答案
- 植物源农药的提取分离和结构鉴定基础
- 银行年度金融消费者权益保护工作自评报告
- (项目管理)项目管理硕士(MPM)项目
- 输尿管结石病人护理查房
- 田间管理记录表
评论
0/150
提交评论