1、精选优质文档-倾情为你奉上精选优质文档-倾情为你奉上专心-专注-专业专心-专注-专业精选优质文档-倾情为你奉上专心-专注-专业plc在电网备用自动投入的应用 目录目录. . . . 1摘要. . . . 2Abstract . . . . 3 TOC o 1-3 h z u 3 PLC系统配置及程序设计. . . . .8 3.1plc的系统配置. . . . . . . . .8 3.2 程序设计. . . . . . .84结论2外文文献. . . . . 14 摘要根据备用电源自动投入装置使用的特点,将PLC芯片应用于备用电源自动投入装置用于电网设备电源自动切换,解决断电时的工作电压的消

2、失,导致用户权限问题。关键词: PLC、备用电源、自动投入 Abstract :Automatic input device used according to the standby power supply, PLC chip is used in the automatic standby power supply automatic switching device for power equipment, working voltage power of the disappearance, leading to user rights problem. Key words: PLC

3、、standby power、 automatic input 第一章 总体设计1.1系统实现功能1、在正常操作过程中,G变电站由WL1电力线,H变电站由WL2电力线,相互暗交替。当任一线路故障跳闸,重合闸装置相应的动作,如重合闸成功,备自投不行动。如果不成功,那么BZT装置,恢复工作。2、 性能参数1 动作可靠性 2 动作时间的设定 3 PLC动态响应参数4 PLC静态响应参数3、 系统采用单总线系统的性能参数,对一些重要用户供电双回路供电方式,两个变电站和电力用户,当正常运作自己的独立运作,相互暗交替。采用PLC电路简单(外围元件少),控制准确,可靠性高。4、注意事项:1工作环境2控制系统

4、中干扰及其来源3主要抗干扰措施1.2 PLC简介 1.2.1可编程控制器简介自1969以来,美国首先研制的PLC在世界各地,日本,德国,法国和其他国家已经建立了自己的公司,受到工业界的重视。十九年代中期,可编程控制器进入实用阶段。PLC PLC的微计算机技术全面的介绍,从而产生了一个飞跃,功能更加完善。基于逻辑功能,提高了数值计算,PID调节等功能,提高了计算速度。PLC的小型化,低成本,高可靠性,并确定了它在现代工业中的地位。PLC的小型化,低成本,高可靠性,并确定了它在现代工业中的地位。十九年代末和80年代初,可编程控制器已步入成熟阶段,为大规模,高速度,高性能的发展,形成了多种系列产品,

5、编程语言也发展起来。我国在上世纪十九年代开始,80年代初引入PLC,来80年代中期,PLC已广泛应用于冶金,化工,机械等工业部门。中国早期的独立研究和北京机械工业自动化研究所单位有一定的影响,上海工业自动化仪表研究所,大连组合机床研究所,成都,电气机械,对中科院北京自动化研究所长春机床,计算和蒸汽所,上海起重电器厂,上海香港电器有限公司上海自力电子设备厂,和其他单位,但单位没有形成规模生产。随着改革的过程中,PLC厂家的出现;辽宁无线电二厂德国西门子技术的引入对s5-101u生产,s5-115系列PLC;中美合资厦门A-B公司生产的plc-2,PLC-5系列PLC。据统计,1996,国内销售的

6、90000台湾(套)PLC,其中进口80000台湾(套),主要生产厂家有以下:1西门子20.83%。(2)莫迪康(施耐德),B(罗克韦尔),欧姆龙:14.58%;3三菱8.33%。通用电气(4):6.25%;富士电机(5):4.17%;(6)其他品牌:4.16%。1.2.3继电器控制: PLC的梯形图与继电器控制线路图十分相似,主要原因是PLC梯形图的注释通常遵循符号电气继电器控制,只由一个有点不同。同时,该信号与控制的功能是相同的输入/输出,但控制继电器PLC和差异,主要表现在以下几个方面。(1)控制逻辑:继电器控制逻辑采用硬接线逻辑,利用继电器机械触点的串联与并联及延时继电器的滞后动作等组

7、合成控制逻辑,其接线多而复杂,体积大,功耗大,一旦系统构成后,想再改变或增加功能都很困难。另外,继电器触点数目有限灵活性和扩展性很差。(2)工作方式:当电源接通时,继电器控制线路中各继电器都处于受约状态,既该吸合的都应吸合,不该吸合的都应受某种条件限制不能吸合。而在PLC的控制逻辑中,各继电器都处于周期性循环扫描接通之中,从宏观上看,每个继电器受制约接通的时间是短暂的。(3)控制速度:继电器控制逻辑依靠触点的机械动作实现控制,工作频率低。角点的开闭动作一般在几十毫米数量级,另外,机械触点还会出现抖动问题。而PLC是由程序指令控制半导体电阻来实现控制,速度极快,一般一条用户指令的执行时间在微秒数

8、量级。PLC内部还有严格的同步,不会出现抖动问题(4)可靠性和可维护性:继电器控制逻辑使用了大量的机械触点,连线也多,触点开闭合时会受到电弧的损坏,并有机械磨损,寿命短,因此可靠性和可维护性差。而PLC采用微电子技术,大量的开关动作由无触点的半导体电路来完成,它体积小、寿命长、可靠性高。PLC还配有自检和监督功能,能、检查出自身的故障,并随时显示给操作人员,还能动态的监视控制程序情况,为现场调试和维护提供了方便。 1.3电气主接线图:低压电力网供电系统被广泛应用在闭环设计,开环运行方式。对110kV电网供电局的正常运行,变电站(简称G)由WL1电源线,另一个变电站(简称H)的wl2电源线,两个

9、CD线实现相互暗备用电源结构。在正常运作,在G和H作为备用电源的同时,CD线,当其中一个变电站的功率损耗,可以通过电力变电站供电点的CD线自动恢复,电气主接线如图1-1所示。图1-1电气主接线第二章 备自投的基本要求及动作顺序逻辑2.1备自投的基本要求(1)操作电源电压无论什么原因消失后,设备将开始工作。(2)切断电源,备用电源可投入。(3)工作时间应尽可能的短。只有一次。也不允许试送。(4)在备用电源无电压和器件的两个铂不应该采取行动。(5)操作装置应灵活。而在投资到故障点的制备可以快速,选择性备用电源了。2.2变电站母联备自投动作顺序逻辑1 . 备自投逻辑动作充电条件:进线开关在合位置,备

10、自投开关打到投入位置,所在的母联在分闸位置,本段进线母线电压正常,以上条件全部满足5秒后备自投充电完成。向另外一段进线发出备自投条件满足信号。VL1 = I12 (开关合位置)AND I23(备自投开关在投入位置)AND (NOT I24 )母 联在分位置)AND P59_1_3 (本段母线有电压) VL2 = TON(VL1 ,5000 ) / bzt enable o12-I14 V1 = TOF(VL2 ,2000 )/备自投充电逻辑(此处延时的目的是防止母线电压波动,记住此处的时间必须比低电压的延时要短,否则会出现两边都失压的时候备自投跳本侧进线) VL3 = TOF(VL2 ,500

11、0 )(此处延时的目的模拟本段电压从有压到无压的过程,备自投必须失母线开始有压到后来失压,记住此处的时间必须比低电压的延时要长一点,但是不能太长,最好是比低电压长1000ms左右,否则会出现多次备自投的情况) 2 备自投逻辑非操作条件:在关闭位置线开关,由P突破压力损失,进行过电流保护动作,终端线路电压损耗开关不跳闸命令和侧BZT信号不符合。任何一个上述条件不满足的备自投是不执行的。 3 备自投逻辑动作进行过程:本段进线开关在合位置延时5秒后(即充电完成以后),低电压发生(延0.5s),没有发生PT断线。以上条件满足后备自投跳进线,同时判断本段进线跳开,没有发生过流保护动作(延长闭锁5s),另

12、段进线备自投条件满足(有压,开关在合位,自投位置);保护发出备自投合母联脉冲(保证只合闸一次)。 VL4 = TON(I12,5000 ) VL5 = P27/27S_1_3 (母线发生低电压)AND (NOT PVTS_1_3 ) (没有发生PT断 线)AND VL4(开关合位置延时5s) AND VL3(本段母线有压延时) AND I14(对侧进线满足备自投条件) AND I23(备自投开关在投入位置) V_TRIPCB = VL5/备自投跳进线 VL6 = TOF(VL5 ,500 ) VL7 = P50/51_1_1 OR P50/51_2_1 VL8 = TOF( VL7 ,1000

13、0 ) VL9 = VL6(进线发出跳自身信号)AND ( NOT VL8) (过流动作闭锁备自投) AND I11(确认开关分位置) AND I14(对侧进线满足备自投条件) V2 = TOF(VL9 ,500 ) / CLOSE BUSBAR O13-I14 向母联发出备自投合母联 信号 4母联收到备自投合闸信号后发出合母联命令。整个备自投过程完成。 2.3抗干扰的主要措施: 1.输入信号电缆、输出信号电缆和电力电缆都要分开敷设,不能扎在一起。 2.必要时需选用带有屏蔽层的输入和输出信号电缆,并注意一端接地。3.多芯电缆中的备用芯线也要一端接地,一则扩大屏蔽作用,二则抑制芯 线间的信号串扰

14、及外部干扰。4.避免干扰,同一电平等级的信号才能用一条多芯电缆传输。所以,对 数字信号和模拟信号,在任何情况下,都必须分开电缆进行传翰。低电平信号线 应与其它信号线分开尽量缩短模拟量IO信号线的长度,并采用双芯屏蔽线作为 信号线。 5.PLC电柜应有独立的接地线,接地电阻小于lO欧姆。 6.引至PLC柜的电缆要尽缆远离那些会产生电磁干扰的装置。 7.一般要将PLC装于专门的电柜中,要注意PLC四周留有50mm以上的净空 间,保证良好的通风环境。在设备现场,要充分考虑周围环境的影响,尽量不要 将PLC安装在多尘、有油烟、有导电灰尘、有腐蚀性气体、振动、热源或潮湿的 地方。第三章 PLC系统配置及

15、程序设计3.1 PLC的系统配置由于时间继电器延时误差和随机性,在传统的,上、下层之间不能及时做好继电保护,容易造成超级跳闸或误跳闸的现象;另外,由于该装置的动作值差异较大,有很多不便,继电保护调试设置。基于多种原因,为了保证供电的可靠性,采用S7系列PLC在BZT装置的控制。具体的配置:PLC CPU226,24输入/ 16输出,总共40个数字I / O,和两个RS485接口,可以很容易地进行数据交换和人机接口,并提供了多种功能,与各种基本的操作指令,一般的计算机编程,控制灵活、方便,其外部接线如图3-1所示。图3-1PLC外部接线3.2程序设计 1、 在PLC通常提供了编程语言梯形图,功能

16、图、语句表等。梯形图编程是一种最广泛使用的编程方法。本实用新型具有易于理解的优点。根据系统的需求分析,采用梯形图编程可以发挥其优势。控制系统的梯形图是借助计算机辅助设计程序图3-2显示系统,利用添加剂winv3.2专为S7-200系列设计编程软件包,梯形图和语句表可以相互转化。图3-2系统控制的梯形2、程序设计本系统设计分别将进线的PLC控制的跳闸信号引入断路器控制回路中,为防止手动对进线断路器进行分闸操作时引起母联自动投入控制回路误动作,在进线手动分闸回路中转入1对转换开关接点,设定为手动操作时该接点接通,同时在PLC控制的母联自动投入回路断路器合闸回路中也串入1对接点,设定为非手动操作时该

17、接点接通, 继电保护装置也已改为微机保护装置,母联的继电保护在母联合闸后经延时一段时间后取消保护。如果母联继电保护动作,则自动投入装置将不能再进行母联合闸操作,2条进线的微机保护出口接点分别引入PLC内,进线在过流跳闸时,母联不会自动投入。PLC控制梯形图如下:结 论本文介绍了备用电源线两站在本文中PLC自动输入装置中的应用。该系统的应用使110kV电网两个变电站备自投下很好的控制装置,供电可靠性有了很大的提高。设计结果表明,该系统解决了传统的时间继电器延时误差和同哭装置操作值之间的差异问题,方便了继电保护整定和调试。本论文得到了很大的收获:第一个大学两年所学过的知识进行了总结和应用的综合,在

18、写作过程中,我进一步了解PLC系统中的应用。PLC控制系统和变电设备的开关装置的相关知识也有了更深刻的理解。 参考文献:1 耿红旗,吕冬梅,可编程序控制器应用教程M,北京:中国水利水电出版社, 2001年。2 弭洪涛,可编程序控制器(PLC)原理及应用M,北京:中国水利水电出版社, 1998年。3 何衍庆,可编程序控制器原理及应用技巧M,北京:化工业出版社, 1998年。4 于庆广,可编程序控制器原理及系统设计,北京:清华大学出版社, 2005年。5 张桂香,电气控制与PLC应用,北京:化学工业出版社,2001年。英文资料: Central Processing Unit (CPU) is t

19、he brain of a PLC controller. CPU itself is usually one of the microcontrollers. Aforetime these were 8-bit microcontrollers such as 8051, and now these are 16-and 32-bit microcontrollers. Unspoken rule is that youll find mostly Hitachi and Fujicu microcontrollers in PLC controllers by Japanese make

20、rs, Siemens in European controllers, and Motorola microcontrollers in American ones. CPU also takes care of communication, interconnectedness among other parts of PLC controllers, program execution, memory operation, overseeing input and setting up of an output. PLC controllers have complex routines

21、 for memory checkup in order to ensure that PLC memory was not damaged (memory checkup is done for safety reasons).Generally speaking, CPU unit makes a great number of check-ups of the PLC controller itself so eventual errors would be discovered early. You can simply look at any PLC controller and s

22、ee that there are several indicators in the form. of light diodes for error signalization.System memory (today mostly implemented in FLASH technology) is used by a PLC for a process control system. Aside form. this operating system it also contains a user program translated forma ladder diagram to a

23、 binary form. FLASH memory contents can be changed only in case where user program is being changed. PLC controllers were used earlier instead of PLASH memory and have had EPROM memory instead of FLASH memory which had to be erased with UV lamp and programmed on programmers. With the use of FLASH te

24、chnology this process was greatly shortened. Reprogramming a program memory is done through a serial cable in a program for application development.User memory is divided into blocks having special functions. Some parts of a memory are used for storing input and output status. The real status of an

25、input is stored either as “1”or as “0”in a specific memory bit/ each input or output has one corresponding bit in memory. Other parts of memory are used to store variable contents for variables used in used program. For example, time value, or counter value would be stored in this part of the memory

26、.PLC controller can be reprogrammed through a computer (usual way), but also through manual programmers (consoles). This practically means that each PLC controller can programmed through a computer if you have the software needed for programming. Todays transmission computers are ideal for reprogram

27、ming a PLC controller in factory itself. This is of great importance to industry. Once the system is corrected, it is also important to read the right program into a PLC again. It is also good to check from time to time whether program in a PLC has not changed. This helps to avoid hazardous situatio

28、ns in factory rooms (some automakers have established communication networks which regularly check programs in PLC controllers to ensure execution only of good programs).Almost every program for programming a PLC controller possesses various useful options such as: forced switching on and off of the

29、 system input/outputs (I/O lines), program follow up in real time as well as documenting a diagram. This documenting is necessary to understand and define failures and malfunctions. Programmer can add remarks, names of input or output devices, and comments that can be useful when finding errors, or

30、with system maintenance. Adding comments and remarks enables any technician (and not just a person who developed the system) to understand a ladder diagram right away. Comments and remarks can even quote precisely part numbers if replacements would be needed. This would speed up a repair of any prob

31、lems that come up due to bad parts. The old way was such that a person who developed a system had protection on the program, so nobody aside from this person could understand how it was done. Correctly documented ladder diagram allows any technician to understand thoroughly how system functions.Elec

32、trical supply is used in bringing electrical energy to central processing unit. Most PLC controllers work either at 24 VDC or 220 VAC. On some PLC controllers youll find electrical supply as a separate module. Those are usually bigger PLC controllers, while small and medium series already contain th

33、e supply module. User has to determine how much current to take from I/O module to ensure that electrical supply provides appropriate amount of current. Different types of modules use different amounts of electrical current.This electrical supply is usually not used to start external input or output

34、. User has to provide separate supplies in starting PLC controller inputs because then you can ensure so called “pure” supply for the PLC controller. With pure supply we mean supply where industrial environment can not affect it damagingly. Some of the smaller PLC controllers supply their inputs wit

35、h voltage from a small supply source already incorporated into a PLC. 译文从结构上分,PLC分为固定式和组合式(模块式)两种。固定式PLC包括CPU板、I/O板、显示面板、内存块、电源等,这些元素组合成一个不可拆卸的整体。模块式PLC包括CPU模块、I/O模块、内存、电源模块、底板或机架,这些模块可以按照一定规则组合配置。在使用者看来,不必要详细分析CPU的内部电路,但对各部分的工作机制还是应有足够的理解。CPU的控制器控制CPU工作,由它读取指令、解释指令及执行指令。但工作节奏由震荡信号控制。运算器用于进行数字或逻辑运算,在控制器指挥下工作。寄存器参与运算,并存储运算的中间结果,它也是在控制器指挥下工作。CPU速度和内存容量是PLC的重要参数,它们决定着PLC的工作速度,IO数量及软件容量等,因此限制着控制规模。PLC使用

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论