版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、J I A N G S U U N I V E R S I T Y蜂巢结构仿生研究与应用 学院名称: 京江学院 专业班级: J高分子1101 学生姓名: 胡文文 学 号: 41211260 16 指导老师: 吴平 2005年 12月Estimation of human-hemoglobin using honeycomb structure:An application of photonic crystalabstract This paper proposes a method to estimate the hemoglobin concentration in human blood
2、 using 2D honeycomb photonic crystal structure. Though a few works deal with similar kind of investigation, presentresearch delivers an accurate estimation of hemoglobin as compared to previous works. The principleof investigation is based on linear variation of both photonic band gap and absorbance
3、s with respect to different concentration of hemoglobin in human blood. Aside these variations, energy transmittedthrough honeycomb photonic crystal structure is also varied linearly with respect to same concentration.In this work, photonic band gap of honeycomb structure is found using plane wave e
4、xpansion method,whereas absorbance of same structure is computed by employing Maxwell Curl equation. Finally, simulation result revealed that transmitted energy through two dimensional honeycomb photonic crystalstructure containing blood is nicely fitted with linear trend line (R2 = 1) which lead to
5、 an accurate investigation of hemoglobin in human blood. At last, this paper proposes an experimental set up to measurethe said concentrations with the help of an Arduino developmentboard(Uno)containingAtmega320microcontroller.Keywords:Honeycomb photonic crystal structurePhotonic band gapTransmitted
6、 energ1. IntroductionPhotonics crystals are made, artificially created materials inwhich refractive index is periodically modulated in a scale comparable to the scale of the wavelength. Though the concept ofphotonic crystal has originated in the year 1857 by Lord Rayleigh,the research work in the fi
7、eld of photonic crystals is realized afteralmost 100 years, when Yablonovitch and John published twomilestone papers on photonic crystals in 1987 13, since then,photonics have been progressing hastily and showing a remarkableresearch in the field of science and technology. As far as, application of
8、photonic-devices are concerned, photonic crystal play animportant role to envisage various application in modern technology 46. Though photonic crystal is used for different application,sensing application is one of the major relevance in photonics. As faras literature surveys on sensing application
9、 using photonic crystalstructure is concerned, recently few papers deal with similar typeof research 713. Considering a brief remark on above references,it is seen that reference 7 presents a novel method to find out theconcentration of sugar, salt, and alcohol in their aqueous solution.In this case
10、, the author used 2D photonic crystal structure with11 11 air holes.Also using same technique, concentration of PAMhydrogel and strength of Cygel is investigated in Refs. 8,9, respectively. Also in Refs. 10,11, the concentration of potassium chloridein their aqueous and intrallipid in human blood is
11、 estimated usingphotonic crystal fiber. Apart from these, measurement of glycerolin BHG solution and concentration of hemoglobin in humanblood is investigated using 3D photonic crystal structure in Refs.12,13, respectively. Though Ref. 13 measures the concentrationof hemoglobin in human blood using
12、3D photonic crystal structure,it is hard to fabricate 3D owing to photonic crystal structure. We inthis paper investigate the concentration of hemoglobin in humanblood using 2D honeycomb photonic crystal structure. The reasonfor choosing such structure is that it can be easily fabricated; secondly,
13、these structures predict accurate result as compared to 3Dphotonic crystal structure, which is carried out in Ref. 13.Hemoglobin is a main component of the blood, which isimportant for transportation of oxygen in blood, which leadsto circulation of blood in vein. This circulation of human bloodsyste
14、m has default functions, such as supply of oxygen to tissues, supply of nutrients such as glucose, amino acids, and fattyacids, removal of waste such as carbon dioxide, urea, lactic acid,immunological functions, including circulation of white cells, anddetection of foreign materials by antibodies, c
15、oagulation, messenger functions, regulation of body PH, regulation oh core bodytemperature hydraulic function etc. for normal human body. Adeficiency of hemoglobin in human blood creates serious problemsuch as downstream tissue dysfunction, Leukemia, iron deficiency,anemia, multiple myeloma, etc. 14
16、17. Keeping the importanceof hemoglobin in human blood, this paper estimates the concentration of hemoglobin in both oxygenated and deoxygenatedblood.This paper is organized as follows: Section 2 presents the structure of the honeycomb photonic crystal structure including theprinciple of measurement
17、. Simulation result and interpretation ismade in Section 3. Section 4 proposes an experimental set up andfinally conclusions are drawn in Section 5.2. Honeycomb structure and principle of measurementAs far as measurement of hemoglobin in human blood is concerned, we use 2D honeycomb photonic crystal
18、 structure for thesame, which is shown in Fig. 1.Fig. 1 represents honeycomb photonic crystal structure having gallium Arsenide as background material containing air holes,where bloods with different percentage (g/L) of hemoglobin areinfiltrated. The proposed structure consists of 9 numbers of air h
19、olessuch that diameter of air holes is 420 nm and lattice spacing of thestructure is 1 m. The principle of measurement is based on linear variation of reflected energy and absorbance with respect toconcentration of hemoglobin in human blood. When light havingwavelength of 589 nm incident on honeycom
20、b structure containingblood with different percentage of hemoglobin then, some amountof light will get reflect and some amount of light will be absorbed bythe structure. The rest amount of light will be transmitted throughthe structure. Since the principle is based on linear variation ofboth reflect
21、ed and absorbance, intensity transmitted through honeycomb structure also varies linearly with respect to hemoglobinconcentration in the blood which is a key factor (linear variation)to realize accurate investigation of hemoglobin in human blood.We use simple mathematical equation to find out the re
22、flectedenergy, absorbance and transmitted energy for investigation ofhemoglobin. As far as, energy reflected from honeycomb structure is concerned, it is obtained from dispersion diagram, whichis carried out by employing plane wave expansion method 18In this case, we computed normalized frequency (a
23、/) fromdispersion diagram, then the values of reflected energy (ER) is calculated using following simple equation:ER=hc/R,where R is reflected wavelength, which is found from dispersion diagram.Since, wavelength 589 nm is used to investigate hemoglobinconcentration; the energy of incident light (EI)
24、 corresponding tothis wavelength is found using following expression.EI (2)where is the incident wavelength (589 nm)Using (1) and (2), the energy transmitted through the structureis written asET = E0 ER (3)Eq. (3) represents as transmitted energy without considerationof absorption loss. However, fro
25、m literature it is found that GaAsstructure and blood with different concentration of hemoglobinabsorb some light of wavelength, 589 nm. So, absorption loss shouldbe cogitated during this investigation. Using Ref. 19 and employing Maxwell curl equation, Eq. (3) is modified asET (4)From the above equ
26、ation, it is seen that absorption loss takesplace due to two factors, such as absorption loss due to backgroundmaterialand absorption loss due to blood .Where is called the absorption coefficient of gallium arsenidematerial and t is the thickness of background or substrate. is called the absorption
27、coefficient of blood at wavelength589 nm, which is expressed where is called the extinction coefficient of blood at wavelength589 nm and C is the concentration of hemoglobin in human bloodand d is the diameter of air holes, where blood samples are infiltration.Using the above equation, output energy
28、 through 2D honeycomb photonic crystal structure is obtained corresponding to eachconcentration of hemoglobin in human blood sample.3. Result and interpretation From previous section, it is seen that output energy through thephotonic crystal structure corresponding to each concentration is a functio
29、n of both reflected energy from the structure and energyabsorbed by the structure. As both reflection energy and absorption loss are important to obtain transmitted energy, we divide thissection into three sub-sections such that first sub-section discussesreflected energy, second sub-section analyse
30、s absorption loss and then transmitted energy is given in third subsection. 3.1. Reflected energy We use dispersion diagram to compute the energy reflectedfrom honeycomb photonic crystal structure. Dispersion diagram isa graph between normalized frequency (a/) with wave vector (k),which gives an ide
31、a about the photonic band gap or reflected energyfrom same structure. So before going to compute reflected energy,we focus on dispersion diagram of 2D photonic honeycomb structure containing human blood sample with different percentageof hemoglobin. The dispersion relation (relation between normaliz
32、ed frequency and wave vector) depends on structure parameterssuch diameter of holes, lattice spacing, refractive indices of bothbackground and blood sample including the configuration of thestructure In this case, we consider honeycomb structure whose latticespacing is 1 m and diameter of air holes
33、is 420 nm. Using theabove parameters and employing plane wave expansion method,simulation is made to obtain the dispersion graph of 2D honeycomb photonic crystal structure. Though, we have made simulationfor all concentration of hemoglobin from 0 g/L to 120/g/L of oxygenated and deoxygenated, simula
34、tion result for 0 g/L and 120 g/Lof oxygenated blood is shown in Fig. 2(a) and (b), respectively.Fig. 2(a) and (b) represent the dispersion diagram of 2D honeycomb photonic crystal structure containing human blood withhemoglobin concentration of 0 g/L and 120 g/L respectively. In thesefigures, norma
35、lized frequency (a/) is taken along vertical axisand wave vector (k) in m1 is taken along horizontal axis. Fromthese graphs, it is realized that electromagnetic wave at certainwavelength range cannot be propagated through the said photonic crystal structure, which refers as forbidden gap. It is also
36、seen that red color band is represented as complete forbidden gap.From this graph, normalized frequency corresponding to 0 and120 concentration of human blood is found, and then photonicbandgap corresponding to each normalized frequency is computed.Though simulation result for 0 g/L and 120 g/L conc
37、entrations areshown here, simulation for other concentration of oxygenated anddeoxygenated blood are done but are not shown here. The photonic band gap corresponding to each normalized frequency ofoxygenated and de-oxygenated blood is investigated. The photonic band gap of said photonic crystal stru
38、cture is nothing but thereflected energy (ER) from 2D honeycomb photonic crystal structure containing both oxygenated and de-oxygenated solution withdifferent concentration of hemoglobin. After computing reflectedenergy corresponding to each concentration of hemoglobin, wemoved to calculate absorpti
39、on loss by said structure which is discussed in the next subsection.3.2. Absorption loss From Section 2, it is clear that absorption depends on bothstructure (background) of photonic crystal structure and humanblood with different concentration of hemoglobin. Since, the background material is fixed
40、for measurement of all concentrationof hemoglobin, absorption due to background material (et) issame for all concentration. However, absorbance due to blood isdiffered for different concentration of hemoglobin because theabsorbance coefficient ( = c) depends on the concentration (c),so that absorban
41、ce due to hemoglobin concentration will be eThen the resultant absorbance is e The value of and is obtained from the literature 20. By putting the value of and d in Eq. (5), we compute the resultant absorbance with respectto concentration of hemoglobin of oxygenated and de-oxygenatedhuman blood. Aft
42、er computing both reflectance and absorbance,we compute the transmitted energy through the photonic crystal structure, which is discussed in the next session.3.3. Transmitted energy Before going to discuss transmitted energy emerging from thephotonic crystal structure, we propose an experimental set
43、up bywhich one can measure the energy emerging from honeycombphotonic crystal structure. The setup is shown in Fig. 3.Fig. 3 represents a proposed experimental setup to estimatethe concentration of hemoglobin in both oxygenated and deoxygenated blood. From this figure, it is seen that light havingwa
44、velength of 589 nm incidents on 2D honeycomb photonic crystal structure, then some amount of light will be reflected and somegets absorbed by it and rest mount of light reaches at photo detectorand finally potential corresponding to such output light is collected at an Arduino development board (UNO
45、) with an LCD display.Here, Arduino UNO is a development board containing Atmega 320with an LCD interfaced which is used to display both potentialcoming from photo detector corresponding to the concentrationof hemoglobin in human blood. Since, reflected energy as well asabsorbance is different for d
46、ifferent concentration of hemoglobin,transmitted energy as well as potential corresponding to transmitted energy is differed from different concentration. Since, thispaper emphasizes on simulation work, the transmitted energy iscomputed using Eq. (4). After calculating the transmitted energy,a graph
47、 is plotted between transmitted energy with respect to different percentages of hemoglobin which is shown in Fig. 4.ent percentages of hemoglobin which is shown in Fig. 4.Fig. 4 provides the information regarding the variation of transmitting energy emerging from 2D honeycomb photonic crystalstructu
48、re with respect to concentration of hemoglobin in oxygenated and de-oxygenated blood. From Fig. 4, it is seen thatthe concentration of hemoglobin (g/L) is taken along primaryx-axis, where transmitting energy in eV for oxygenated and deoxygenated blood sample is taken along primary and secondary y-ax
49、isrespectively. From above graph, it is observed that the transmittedenergy decreases linearly with respect to hemoglobin concentration, which varies from 0 g/L to 120 g/L for both oxygenated andde-oxygenated blood. For example, transmitted energy decreases from 0.460 eV to 0.4596 eV for oxygenated
50、and 0.460eV to0.4434 eV for de-oxygenated blood with respect to hemoglobinestimation of hemoglobin. The simulation for reflected energy ismade by employing the plane wave expansion method, whereabsorption loss is computed using Maxwell equation. An experimental setup is also proposed to obtain hemog
51、lobin in human bloodsample. Simulation result revealed that transmitted energy varieslinearly and also these variationsare an excellently fitted withlinear shift, which gives an accurate investigation of hemoglobin inboth oxygenated and de-oxygenated human blood sample. Finally,Ardunio UNO divulged
52、the concentration of human hemoglobinwith potential emerging from photonic crystal structure.4. Conclusion Estimation of hemoglobin in oxygenated and de-oxygenatedhuman blood sample is thoroughly investigated in this paper.Both absorption and reflection losses are cogitated during theestimation of h
53、emoglobin. The simulation for reflected energy ismade by employing the plane wave expansion method, whereabsorption loss is computed using Maxwell equation. An experimental setup is also proposed to obtain hemoglobin in human bloodsample. Simulation result revealed that transmitted energy variesline
54、arly and also these variationsare an excellently fitted withlinear shift, which gives an accurate investigation of hemoglobin inboth oxygenated and de-oxygenated human blood sample. Finally,Ardunio UNO divulged the concentration of human hemoglobinwith potential emerging from photonic crystal struct
55、ure.References1 J.W.S. Rayleigh, On the remarkable phenomenon of crystalline reflexiondescribed by Prof. Stokes, Philos. Mag. 26 (1988) 256265.2 E. Yablonovitch, Inhibited spontaneous emission in solid-state physics andelectronics, Phys. Rev. Lett. 58 (1987) 20592062.3 S. John, Strong localization o
56、f photons in certain disordered dielectric superlattices, Phys. Rev. Lett. 58 (1987) 24862489.4 M.D. Turner, M. Saba, Q. Zhang, B.P. Cumming, G.E. Schrder-Turk, M. Gu, Miniature chiral beamsplitter based on gyroid photonic crystals, Nat. Photonics 7(2013) 801.5 J.D. Joannopoulos, S.G. Johnson, J.N.
57、Winn, R.D. Meade, Photonic Crystals: Molding the Flow of Light, second ed., Princeton University Press, Princeton, NJ,2008.6 K.V. Pravdin, I.Yu. Popov, Photonic crystal with negative index material layers,Nanosyst.: Phys. Chem. Math. 5 (2014) 626643.7 G. Palai, S.K. Tripathy, A novel method for measurement of concentrationusing two dimensional photonic crystal structures, Opt. Commun. 285 (2012)27652768.8 G. Pa
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024it公司合作合同:网络安全防护系统设计与实施2篇
- 2024年度教育服务合同:国际学校合作办学协议3篇
- 2024年度软件开发与定制合同标的详细2篇
- 2024年安全生产技术转让合同3篇
- 2024年度重型机械融资租赁合同担保书3篇
- 2024年农业科技合作合伙协议书3篇
- 2024年度不良资产投资与处置联合体合作协议3篇
- 2024全新农业项目对赌协议范文下载3篇
- 2024年绿色建筑安置住房买卖合同范本2篇
- 2024年代持股份权益转让书3篇
- 食品安全知识培训
- 期末试题-2024-2025学年语文六年级上册统编版
- 狼蛛课件教学课件
- 成品油运输 投标方案(技术方案)
- 2024-2030年中国水利工程行业发展规划投资战略分析报告
- 常见消防安全隐患图解精美
- 企业劳动人事合规的法律咨询与服务行业市场调研分析报告
- 餐饮服务电子教案 学习任务4 摆台技能(4)-西餐宴会餐台摆台
- 中国电建在线测评题
- 安徽社区食堂投标方案
- 不良行为学生教育转化工作实施方案
评论
0/150
提交评论