1、房间编号房间编号:面积(m2设计单位冷量w/m2设计总冷量kw设计单位热量设计总热量国祥型号首层:型号单位冷量kw数量(台 1厨房233002ST 6.51200.78700.455KCR-200C 2.151 3ST7.041200.8448700.4928KCR-200C 2.151 4ST14.5120 1.7470 1.015KCR-200C 2.151 5宴会厅7203502527050.4KDC120-469.34 6办公室7150 1.05700.49KCR-200C 2.151 7行李房71000.7700.49KCR-200C 2.151 8电梯厅551508.2570 3.

2、85KCR-1000C9.481 9酒店大堂21320042.67014.91KCR-1200C11.54 10商务中心20150370 1.4KCR-300C 3.261 11电梯厅42150 6.370 2.94KCR-800C7.321 12茶餐厅10930032.7707.63KCR-1200C11.53 13便利店23.5250 5.87570 1.645KCR-600C 5.81 14CD/文具店23.5250 5.87570 1.645KCR-600C 5.81 15面包店36250970 2.52KCR-1000C9.481 16厨房300070 2.117特色餐饮18250

3、4.570 1.26KCR-500C 4.851 18甜品店26250 6.570 1.82KCR-800C7.321 19西药房20250570 1.4KCR-600C 5.81 20茶/烟/酒店20250570 1.4KCR-600C 5.81 21超市12625031.5708.82KCR-1200C11.53 22外廊234新风降温至24度,餐厅的新风直接引入吊柜30二层2_1A中餐包房015830017.470 4.06KCR-1000C9.482 2_2B中餐包房02273008.170 1.89KCR-1000C9.481 2_3B中餐包房03273008.170 1.89KCR

4、-1000C9.481 2_4B中餐包房04273008.170 1.89KCR-1000C9.4812_5B中餐包房05273008.170 1.89KCR-1000C9.481 2_6B中餐包房0632.283009.68470 2.2596KCR-1200C11.51 2_7A中餐包房0767.3230020.19670 4.7124KCR-1200C11.52 2_8C中餐包房0840.0730012.02170 2.8049KCR-1200C11.51 2_9A中餐包房097830023.470 5.46KCR-1400C12.92 2_10B中餐包房107830023.470 5.

5、46KCR-1400C12.92 2_11B中餐包房11293008.770 2.03KCR-1000C9.481 2_12B中餐包房12293008.770 2.03KCR-1000C9.481 2_13B中餐包房13293008.770 2.03KCR-1000C9.481 2_14B中餐包房14293008.770 2.03KCR-1000C9.481 2_15A中餐包房156* 4.2KCR-1000C9.482 2_16D小宴会厅269.3130080.7937018.8517KDC070-4422 2_17A沐足房0113.64200 2.728700.9548KCR-300C 3

6、.261 2_18B沐足房0223.66200 4.73270 1.6562KCR-500C 4.851 2_19C沐足房0325.67200 5.13470 1.7969KCR-600C 5.81 2_20C沐足房0424.23200 4.84670 1.6961KCR-500C 4.851 2_21C沐足房0520.03200 4.00670 1.4021KCR-400C41 2_22C沐足房0637.112007.42270 2.5977KCR-800C7.321 2_23A沐足房0717.44200 3.48870 1.2208KCR-400C41 2_24A沐足房088.76200

7、1.752700.6132KCR-200C 2.151 2_25A沐足房098.8200 1.76700.616KCR-200C 2.151 2_26A沐足房1012.46200 2.492700.8722KCR-300C 3.261 2_27A沐足房1113.6200 2.72700.952KCR-300C 3.261 2_28A沐足房1212.45200 2.49700.8715KCR-300C 3.261 2_29A沐足房1313.62200 2.724700.9534KCR-300C 3.261 2_30A沐足房1410.29200 2.058700.7203KCR-200C 2.15

8、1 2_31A沐足房1511.53200 2.306700.8071KCR-300C 3.261 2_32A沐足房1610.69200 2.138700.7483KCR-200C 2.151 2_33A沐足房1711.9200 2.38700.833KCR-300C 3.261 2_34A沐足房1817.78200 3.55670 1.2446KCR-400C412_35A沐足房1913.12200 2.624700.9184KCR-300C 3.261 2_36A沐足房2017.78200 3.55670 1.2446KCR-400C41 2_37A沐足房2113.12200 2.62470

9、0.9184KCR-300C 3.261 2_38A沐足房2217.82200 3.56470 1.2474KCR-400C41 2_39A沐足房2312.94200 2.588700.9058KCR-300C 3.261 2_40A沐足房2412.42200 2.484700.8694KCR-300C 3.261 2_41A沐足房2512.94200 2.588700.9058KCR-300C 3.261外廊398新风降温至24度24三层KTV:3_1C型R3.01432309.8970 3.01KCR-1200C11.51 3_2C型R3.0230230 6.970 2.1KCR-800C

10、7.321 3_3C型R3.0330230 6.970 2.1KCR-800C7.321 3_4C型R3.0430230 6.970 2.1KCR-800C7.321 3_5C型R3.0530230 6.970 2.1KCR-800C7.321 3_6C型R3.0630230 6.970 2.1KCR-800C7.321 3_7C型R3.0730230 6.970 2.1KCR-800C7.321 3_8C型R3.0830230 6.970 2.1KCR-800C7.321 3_9B型R3.09342307.8270 2.38KCR-1000C9.481 3_10B型R3.10332307.5

11、970 2.31KCR-1000C9.481 3_11C型R3.114523010.3570 3.15KCR-1200C11.51 3_12D型R3.128023018.470 5.6KCR-1200C11.52 3_13B型R3.13332307.5970 2.31KCR-1000C9.481 3_14B型R3.14342307.8270 2.38KCR-1000C9.481 3_15A型R3.1530230 6.970 2.1KCR-800C7.321 3_16A型R3.16392308.9770 2.73KCR-1000C9.481 3_17A型R3.17392308.9770 2.73

12、KCR-1000C9.481 3_18A型R3.18392308.9770 2.73KCR-1000C9.481 3_19A型R3.19392308.9770 2.73KCR-1000C9.481 3_20G型R3.2026230 5.9870 1.82KCR-800C7.3213_21G型R3.21332307.5970 2.31KCR-1000C9.481 3_22G型R3.22322307.3670 2.24KCR-1000C9.481 3_23F型R3.2337.52308.62570 2.625KCR-1000C9.481 3_24F型R3.2431.52307.24570 2.20

13、5KCR-1000C9.481 3_25F型R3.25382308.7470 2.66KCR-1000C9.481 3_26A型R3.2629230 6.6770 2.03KCR-800C7.321 3_27E型R3.27422309.6670 2.94KCR-1200C11.51 3_28E型R3.284923011.2770 3.43KCR-1400C12.91 3_29C型R3.2929230 6.6770 2.03KCR-800C7.321 3_30C型R3.3029230 6.6770 2.03KCR-800C7.321 3_31E型R3.3144.523010.23570 3.11

14、5KCR-1200C11.51 3_32C型R3.3229230 6.6770 2.03KCR-800C7.321 3_33C型R3.3327230 6.2170 1.89KCR-800C7.321 3_34C型R3.3428230 6.4470 1.96KCR-800C7.321 3_35A型R3.354723010.8170 3.29KCR-1200C11.51外廊449新风降温至24度70四层:4_1A型R4.0128.67120 3.440470 2.0069KCR-400C41 4_2A型R4.0228.6120 3.43270 2.002KCR-400C41 4_3A型R4.032

15、8.67120 3.440470 2.0069KCR-400C41 4_4A型R4.0428.6120 3.43270 2.002KCR-400C41 4_5A型R4.0528.67120 3.440470 2.0069KCR-400C41 4_6A型R4.0628.6120 3.43270 2.002KCR-400C41 4_7A型R4.0728.67120 3.440470 2.0069KCR-400C41 4_8A型R4.0828.6120 3.43270 2.002KCR-400C41 4_9A型R4.0928.67120 3.440470 2.0069KCR-400C41 4_10A

16、型R4.1028.22120 3.386470 1.9754KCR-400C41 4_11A型R4.1128.59120 3.430870 2.0013KCR-400C414_12A型R4.1227.71120 3.325270 1.9397KCR-400C41 4_13A型R4.1322.84120 2.740870 1.5988KCR-400C41 4_14A型R4.1424.36120 2.923270 1.7052KCR-400C41 4_15A型R4.1528.4120 3.40870 1.988KCR-400C41 4_16A型R4.1628.4120 3.40870 1.988K

17、CR-400C41 4_17A型R4.1761.811207.417270 4.3267KCR-1000C9.481 4_18A型R4.1828.7120 3.44470 2.009KCR-400C41 4_19A型R4.1927.54120 3.304870 1.9278KCR-400C41 4_20A型R4.2028.7120 3.44470 2.009KCR-400C41 4_21A型R4.2127.54120 3.304870 1.9278KCR-400C41 4_22A型R4.2242.63120 5.115670 2.9841KCR-600C 5.81 4_23布草23.36000

18、4_24中餐大厅519.32300155.7967036.3524KDC070-4424外廊452新风降温至24度28五层:5_1A型R5.141.34120 4.960870 2.8938KCR-600C 5.81 5_2A型R5.228.67120 3.440470 2.0069KCR-400C41 5_3A型R5.328.6120 3.43270 2.002KCR-400C41 5_4A型R5.428.67120 3.440470 2.0069KCR-400C41 5_5A型R5.528.6120 3.43270 2.002KCR-400C41 5_6A型R5.628.67120 3.4

19、40470 2.0069KCR-400C41 5_7A型R5.728.6120 3.43270 2.002KCR-400C41 5_8A型R5.828.67120 3.440470 2.0069KCR-400C41 5_9A型R5.928.6120 3.43270 2.002KCR-400C41 5_10A型R5.1028.67120 3.440470 2.0069KCR-400C41 5_11A型R5.1128.22120 3.386470 1.9754KCR-400C41 5_12A型R5.1231.79120 3.814870 2.2253KCR-400C41 5_13A型R5.1333

20、.05120 3.96670 2.3135KCR-400C41 5_14A型R5.1431.37120 3.764470 2.1959KCR-400C415_15A型R5.1528.59120 3.430870 2.0013KCR-400C41 5_16A型R5.1627.71120 3.325270 1.9397KCR-400C41 5_17A型R5.1722.84120 2.740870 1.5988KCR-400C41 5_18A型R5.1824.36120 2.923270 1.7052KCR-400C41 5_19A型R5.1928.4120 3.40870 1.988KCR-400

21、C41 5_20A型R5.2028.4120 3.40870 1.988KCR-400C41 5_21A型R5.2161.811207.417270 4.3267KCR-1000C9.481 5_22A型R5.2228.7120 3.44470 2.009KCR-400C41 5_23A型R5.2327.54120 3.304870 1.9278KCR-400C41 5_24A型R5.2428.7120 3.44470 2.009KCR-400C41 5_25A型R5.2527.54120 3.304870 1.9278KCR-400C41 5_26A型R5.2642.63120 5.1156

22、70 2.9841KCR-600C 5.81 5_27布草23.36外廊258新风降温至24度26六层:6_1A型R5.141.34120 4.960870 2.8938KCR-600C 5.81 6_2A型R5.228.67120 3.440470 2.0069KCR-400C41 6_3A型R5.328.6120 3.43270 2.002KCR-400C41 6_4A型R5.428.67120 3.440470 2.0069KCR-400C41 6_5A型R5.528.6120 3.43270 2.002KCR-400C41 6_6A型R5.628.67120 3.440470 2.00

23、69KCR-400C41 6_7A型R5.728.6120 3.43270 2.002KCR-400C41 6_8A型R5.828.67120 3.440470 2.0069KCR-400C41 6_9A型R5.928.6120 3.43270 2.002KCR-400C41 6_10A型R5.1028.67120 3.440470 2.0069KCR-400C41 6_11A型R5.1128.22120 3.386470 1.9754KCR-400C41 6_12A型R5.1231.79120 3.814870 2.2253KCR-400C41 6_13A型R5.1333.05120 3.9

24、6670 2.3135KCR-400C41 6_14A型R5.1431.37120 3.764470 2.1959KCR-400C416_15A型R5.1528.59120 3.430870 2.0013KCR-400C41 6_16A型R5.1627.71120 3.325270 1.9397KCR-400C41 6_17A型R5.1722.84120 2.740870 1.5988KCR-400C41 6_18A型R5.1824.36120 2.923270 1.7052KCR-400C41 6_19A型R5.1928.4120 3.40870 1.988KCR-400C41 6_20A型

25、R5.2028.4120 3.40870 1.988KCR-400C41 6_21A型R5.2161.811207.417270 4.3267KCR-1000C9.481 6_22A型R5.2228.7120 3.44470 2.009KCR-400C41 6_23A型R5.2327.54120 3.304870 1.9278KCR-400C41 6_24A型R5.2428.7120 3.44470 2.009KCR-400C41 6_25A型R5.2527.54120 3.304870 1.9278KCR-400C41 6_26A型R5.2642.63120 5.115670 2.9841K

26、CR-600C 5.81 6_27布草23.36外廊258新风降温至24度26七层:7_1客房117.21230 3.958370 1.2047KCR-400C41 7_2客房225230 5.7570 1.75KCR-600C 5.81 7_3客房319.32230 4.443670 1.3524KCR-600C 5.81 7_4总统套房外区11.3200007_5客厅44.8223010.308670 3.1374KCR-1200C11.51新风由风机盘管直接引入1717.4707487.5262慕兰酒店空调及热水系统方案一、设计概况该建筑位于广东惠州市,设计为集酒店大堂、客房、餐厅、KT

27、V、沐足等为一体的综合性酒店。建筑面积约12000平方米,空调房间面积约为7500平方米,空调走廊面积约为2050平方米(此区域送处理过的新风即可,空调总面积约为9550平方米(注,上述依据为设计图纸,可能存在一定误差。各区域空调负荷参数表详见附表。热水方面,主要用水点位于37层。该酒店卫生热水工程范围:全天24小时为该楼内沐足房间、客房、卫生间洗手提供50-55卫生热水。根据该酒店的特点,建议采用水冷螺杆机组+多功能模块机组+冷暖型风冷模块机组,以保证酒店的制冷、热水、制热都在最经济、节能的工况下运行。二、设计依据1.采暖通风与空气调节设计规范(GB50019-2003;2.建筑给水排水设计

28、规范(GB50015-2003;3.室外给水设计规范(GBJ1386;4.给水排水制图标准(T50106-2001;5.建筑设计防火规范(GBJ16872001;6.建设单位的要求。三、相关设计标准1、室外环境设计计算参数夏季:干球温度:33.5湿球温度:27.7冬季:干球温度:5湿球温度:1.32、室内环境设计计算参数夏季:温度:24+2冬季:温度:20+23、热水设计计算参数(以冬季为标准冷水计算温度:5热水计算温度:55四、负荷分项设计计算及分析说明附表中对各区域作了分别统计计算,下边针对各主要的功能区域进行分析及必要的计算,以便进行综合节能考虑,其中走廊等辅助区域空调量小,不作详细分析

29、。1、空调制冷方面:餐厅(包括一楼大厅、一楼茶餐厅、二楼包房、四楼中餐大厅:总负荷约为1122KW 餐厅的空调负荷特点为:1负荷大,而且负荷集中在短时间内,需要大冷量进行及时的降温处理;2人员密度大,必须进行足够的新风量补充和足够的换气,以保证人体的舒适度;3负荷波动大,因客流的情况室内负荷在客流高峰及少客流阶段的负荷差异很大,所以空调系统即要满足瞬间负荷量大增的需要,也要能实现负荷量小时的低冷量输出,以达到节能效果。4高负荷的出现时间稳定可控,一般出现在中午午餐时间(11:30-13: 30,晚饭时间(18:30-19:30针对餐厅上述特点,室内空调设计采用若干大风量的吊挂式空调机组,以满足

30、室内相关要求,同时新风系统与其它区域分开,由吊挂式空调机组直接引入,如此即可以满足餐厅要求,也可以节约餐厅不营业时因新风机组而消耗的大量能源。沐足房(二楼:总负荷约为90KW沐足房负荷的特点:1负荷不大,但因有热水的使用会使客人有要求降低温度的要求,因此必须适当加大末端的冷量使用;2高负荷的出现时间稳定可控,一般出现在中午午餐时间之后(13:00-14:30,晚饭时间之后(18:30-次日2:00针对餐厅上述特点,室内空调设计采用风机盘管,可以灵活根据房间的使用情况开启、关闭、调节相关设备,相关设备适当选备大;另配置新风系统。KTV房(三楼:总负荷约为326KWKTV房负荷的特点:1负荷较大,

31、人员密度较大,需要大冷量进行及时的降温处理及足够新风量的补充;2高负荷的出现时间稳定可控,一般出现在晚饭时间之后(18: 30-次日2:00针对餐厅上述特点,室内空调设计采用风机盘管,可以灵活根据房间的使用情况开启、关闭、调节相关设备,相关设备适当选备大;另配置新风系统。客房(四-七楼:总负荷约为322KW客房房负荷的特点:1负荷很小,人员密度很低;2高负荷的出现时间不可控。针对餐厅上述特点,室内空调设计采用风机盘管,可以灵活根据房间的使用情况开启、关闭、调节相关设备,相关设备适当选备小;另配置新风系统。2、空调采暖方面:最大总负荷约为487KW因南方气候较为暖和,各功能区域只作适当温度补偿即

32、可满足人体舒适性需要,因采暖要求并不高,新风的要求特点与制冷情况相同,且室内制冷使用的相关设备完全可满足采暖使用,这里不作分区的详细分析。3、生活热水方面1沐足房:有86个位置(按每天12小时,每小时40L/位计算2客房:有83个(按每个房间2人,每人100L计算3卫生间:洗手用水沐足房需要用水量=40*12*86=41280L客房房需要用水量=100*2*83=16600L卫生间用水量很小,同时考虑沐足房及客房的不同时使用系数,对此部分不作统计,只在下边机组总选型的时候作余量处理。热水所需热量Qh=Ld(tr-tl=(41280+16600(55-5=2894000kcal式中Ld-设计日热

33、水用量(m3;m-用水计算单位数(人;qr-设计用热水定额(L;tr-热水计算温度(;tl-冷水计算温度(;Qh-设计日耗热量(kcal) ; 设备平均所需要制热能力(每天额定工作 18 小时计算) : Qh86020=289400086020=168KW 同理: 夏季热水所需热量 Qh2= Ld( trt2)=( 41280+16600)(5520=2025800kcal 设备制热能力:Qh286020=289400086020=130KW 五、负荷综合分析说明及空调机组选型 从上述分析可以看到, 1、夏季空调冷负荷: 全天最大负荷率应该出现在中午午饭时间,此时负荷应该以餐厅为主,交错有沐足

34、房、 相关一楼其它商业区域及部分客房的使用。此时总冷负荷 QA 应为: (餐厅+沐足*0.3+客房 *0.5+其它商业区域) QA=1122+90*0.3+322*0.5+100=1410KW 全天中第二大空调高峰期出现在晚饭时间此时负荷应该以餐厅为主, 交错有沐足房、 KTV 房间相关一楼其它商业区域及部分客房的使用。此时总此时总冷负荷应 QB 为: (餐厅*0.8+ 沐足*0.2+KTV 房*0.1+客房*0.4+其它商业区域*0.5) QB=1122*0.8+90*0.2+326*0.1+322*0.4+100*0.5=1127KW 第三大空调高峰期出现在晚间休息时间,应为沐足房、KTV

35、 房间、及客房集体启动。 此 时负荷 QC 应为: (沐足房+KTV 房+客房) QC=90+326+322=738KW 其它大部分时间以客房及其它商业区域的使用为主。负荷 QD 为: (客房*0.8+其它商业 区域) QD=322*0.8+100=357.6KW 2、热水使用方面: 在前边计算中我们可以看到,热水设备平均热水量必须大于 168KW。考虑到冬季晚饭前 4 后热水的大量使用,主要为客房洗澡用水及沐足用水集中大量增加,选型时必须充分考虑此 时热水需求量大增问题。 夏季:空调机组的热回收须可满足热量的补充 冬季:热水机组的制热须可满足热量的补充 3、机组选型及运行分析 推荐采用满液式

36、螺杆冷水机组(带热回收)+多功能模块机组+冷暖型风冷模块机组 (总冷量达到 1505KW,夏季最大热水热量达到 568KW,冬季达到 252KW,系统最大制热量 504KW) 满液式螺杆冷水机组采用 525KW(热回收量 158KW)两台 多功能机组(65KW 制冷量,热水制热量 82KW、制热量 72KW)三台 冷暖型风冷模块机组(65KW 制冷量,制热量 72KW)四台 使用运行分析 1)夏季方面,制冷系统启动后,系统将优先投入两台满液式螺杆冷水机组(总制冷量 为 525*2KW)进行制冷,同时进行热量的存贮,这样可以使系统在最节能的状况下运行; 两 螺杆机组的制冷量的要求后,自动投入运行

37、多功能热水机(冷量 65KW*3)进行制冷,也可 以同时进行热量的存贮; 若此时还达不到系统制冷量的要求, 再开启冷暖型风冷模块机组 (冷 量 65KW*4) ,直到达到系统所需制冷量为止。 如:前边提到最大负荷 QA 状态时(总需求约为 1410KW) ,系统将自动投入两台螺杆冷 水机组(共 1050KW) ,三台多功能热水机组(共 195KW) ,再投入 2.5 台模块式冷水机组 (162.5KW,注模块机由两压缩机组成,为可以开启一半机组以适应系统冷量要求) 再如:前边提到的负荷第二高峰期 QB 状态时(总需求为 1127KW) ,系统系统将自动投 入两台螺杆冷水机组(共 1050KW) ,一台多功能热水机组(共 65KW) 。 2)夏季方面,当系统负载减小时,系统将优先关闭冷暖型风冷模块机组,再关闭多功 能热水机组,最后调节或关闭螺杆冷水机组,以保证机组在最节能的状况下运行。 3)在热水方面,若螺杆式冷水机组或多功能热水机组在运行,系统自动对空调使用中 的热量进行回收贮存,直到温度达到设定值为止(设计 55 度

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论