版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
1、列管式换热器设计说明书目录一、方案简介···············································
2、;·················32、方案设计·······························
3、3;································41、确定设计方案················&
4、#183;············································42、确定物性数据···
5、3;·················································
6、3;·······43、计算总传热系数·········································
7、··················44、计算传热面积······························
8、83;······························55、工艺结构尺寸··················
9、···········································56、换热器核算·····
10、3;·················································
11、3;·······73、设计结果一览表·········································
12、·················104、对设计的评述·······························
13、183;····························115、附图(主体设备设计条件图)(详情参见图纸)·················&
14、#183;···············6、参考文献·································&
15、#183;······························127、主要符号说明·················
16、83;··········································12附图·······
17、;··················································
18、;·················一、方案简介本设计任务是利用冷流体(水)给硝基苯降温。利用热传递过程中对流传热原则,制成换热器,以供生产需要。下图(图1)是工业生产中用到的列管式换热器.选择换热器时,要遵循经济,传热效果优,方便清洗,复合实际需要等原则。换热器分为几大类:夹套式换热器,沉浸式蛇管换热器,喷淋式换热器,套管式换热器,螺旋板式换热器,板翅式换热器,热管式换热器,列管式换热器等。不同的换热器适用于不同的场合。而列
19、管式换热器在生产中被广泛利用。它的结构简单、坚固、制造较容易、处理能力大、适应性大、操作弹性较大。尤其在高压、高温和大型装置中使用更为普遍。所以首选列管式换热器作为设计基础。二、方案设计某厂在生产过程中,需将硝基苯液体从93冷却到50。处理能力为1×105吨/年。冷却介质采用自来水,入口温度27,出口温度37。要求换热器的管程和壳程的压降不大于10kPa。试设计能完成上述任务的列管式换热器。(每年按300天,每天24小时连续运行)1确定设计方案 (1)选择换热器的类型两流体温度变化情况:热流体进口温度93,出口温度50冷流体。冷流体进口温度27,出口温度37。从两流体温度来看,估计换
20、热器的管壁温度和壳体壁温之差不会很大,因此初步确定选用固定管板式换热器。(2)流动空间及流速的确定 由于硝基苯的粘度比水的大,因此冷却水走管程,硝基苯走壳程。另外,这样的选择可以使硝基苯通过壳体壁面向空气中散热,提高冷却效果。同时,在此选择逆流。选用25×2.5的碳钢管,管内流速取ui=0.5m/。 2、确定物性数据 定性温度:可取流体进口温度的平均值。 壳程硝基苯的定性温度为:管程流体的定性温度为: 根据定性温度,分别查取壳程和管程流体的有关物性数据。 硝基苯在71.5下的有关物性数据如下: 密度 o=1154 kg/m3定压比热容 cpo=1.558kJ/(kg·导热系
21、数 o=418.4×30.9×10-50.129 W/(m·粘度 o=0.000979 Pa·s冷却水在32下的物性数据: 密度 i=994.3kg/m3定压比热容 cpi=4.24 kJ/(kg·导热系数 i=0.618 W/(m·粘度 i=0.000818 Pa·s3计算总传热系数 (1)热流量 Wo=1×105×1000÷300÷2413889kg/hQo=Wocpoto=13889×1.558×(93-50=930479.7 kJ/h=258.5 kW(2)
22、平均传热温差 (3)冷却水用量 (4)总传热系数K 管程传热系数 壳程传热系数 假设壳程的传热系数o=290 W/(m2·; 污垢热阻Rsi=0.000344 m2·/W , Rso=0.000172 m2·/W管壁的导热系数=45 W/(m·4、计算传热面积 考虑 15的面积裕度,S=1.15×S''=1.15×19.24=22.12m25、工艺结构尺寸 (1)管径和管内流速及管长 选用25×2.5传热管(碳钢,取管内流速ui=0.5m/s,选用管长为3m(2)管程数和传热管数 依据传热管内径和流速确定单程
23、传热管数 按单程管计算其流速为按单管程设计,流速过小,宜采用多管程结构。则该换热器管程数为 (管程传热管总根数 N=94 (根(3)平均传热温差校正及壳程数 平均传热温差校正系数 按单壳程,双管程结构,温差校正系数应查有关图表。可得平均传热温差(4)传热管排列和分程方法 采用组合排列法,即每程内均按正三角形排列,隔板两侧采用正方形排列。取管心距t=1.25 d0,则 t=1.25×25=31.2532(mm横过管束中心线的管数得到各程之间可排列11支管,即正六边形可排6层。则实际排管数设为102根,其中4根拉杆,则实际换热器为98根(5)壳体内径 采用多管程结构,取管板利用率0.7,
24、则壳体内径为 圆整可取D400mm (6)折流板 采用弓形折流板,取弓形折流板圆缺高度为壳体内径的25,则切去的圆缺高度为h0.25×400100mm,故可取h100 mm。 取折流板间距B0.5D,则B0.3×400200mm,可取B为200。 折流板数 NB=传热管长/折流板间距-1=3000/200-1=14(块折流板圆缺面水平装配。 (7)接管 壳程流体进出口接管:取接管内硝基苯流速为 u1.0 m/s,则接管内径为 取标准管径为108 mm×11mm。 管程流体进出口接管:取接管内冷却水流速 u1.5 m/s,则接管内径为 取76mm×6.5mm无缝钢管。6换热器核算 (1)热量核算 壳程对流传热系数 对圆缺形折流板,可采用凯恩公式 当量直径,由正三角形排列得 壳程流通截面积 壳程流体流速及其雷诺数分别为 普兰特准数 粘度校正 管程对流传热系数 管程流通截面积管程流体流速 普兰特准数传热系数K传热面积S该换热器的实际传热面积Sp该换热器的面积裕度为 传热面积裕度合适,该换热器能够完成生产任务。 (2)换热器内流体的压力降 管程流动阻力 Pi=(P1+P2FtNsNpNs=1, Np=2, Ft=1.5由Re
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 人教版四年级上册数学第六单元《除数是两位数的除法》测试卷及参考答案【综合题】
- 建筑工程技术咨询合同(3篇)
- 2024年版权使用延期协议2篇
- 解除租赁合同协议书写要点
- 语文课引发的大学教育思考
- 质量保证为梦想助力
- 购车定金支付协议
- 购销合同回款风险防范
- 购销天然气合同范本
- 赞助商资金赞助与权益协议
- 2024年认证行业法律法规及认证基础知识 CCAA年度确认 试题与答案
- 陕煤集团榆林化学有限责任公司招聘笔试题库2024
- 2024年中国直流/交流逆变器市场调查研究报告
- 选择性必修第一册测试 高二上学期数学人教A版
- 静脉注射的并发症及处理
- 2024-2030年中国光学冷加工行业运行态势及前景规划分析报告
- 2024深圳市房地产买卖合同范本
- “电解池”教学设计第1课时
- 博物馆建设项目可行性研究报告
- 实习生肾病内科出科考试试题
- 2024-2030年中国废旧纺织品行业市场深度调研及竞争格局与投资前景研究报告
评论
0/150
提交评论