1、1? 6KV聚氯乙烯绝缘电力电缆载流量1. 0.6/1kv,vv及vlv型聚氯乙烯绝缘及护套电缆长期连续负荷允许载流量13芯长期连续负荷允许载流量/A标称截面2/mn在空气中在地下1芯2芯3芯1-I-R心2芯3芯铜芯铝芯铜芯r铝芯;铜芯铝芯铜芯铝芯铜芯铝芯铜芯r铝芯1.52420173427222.532252821231846353528302344534362931246147473639316564347363931755858454938108061665156431058180626852161068389697659138106105828969251431111179110278

2、1801381331041078335175133143111122942181691641271311015022317018013815412226519620115915912370265207217170191148310239244186195150953292542331803692832311781203822972702074163232622011504453393132444743643002311855193923602815304083372622406094724293346174743903013+1芯或4芯长期连续负荷允许载流量/A标称截面/mvm在空气中在地下铜

3、芯铝芯铜芯铝芯428223728638284636105140614716685380612592711068235115891301015014411116112470178136194148952181682311771202531952632041502972283032331853442633402632. 3.6/6kv,vv及vlv型聚氯乙烯绝缘及护套电缆长期连续负荷允许载流量长期连续负荷允许载流量/A标称截面/mni在空气中在地下1芯3芯1芯3芯铜芯铜芯铜芯铜芯108260906116111811198025143105157104351751271901285022315923

4、415770265191286188953292393432261203822753942581504403134522951855043605003312406044295883813.交联聚氯乙烯绝缘电力电缆的类型及主要技术特征电缆的型号、名称及使用条件型号名称工作条件符号意义铜芯铝芯YJVYJSVYJLV YJLSV交联聚乙烯绝缘聚氯乙烯护套电力电缆架空、室内、隧道、管道、电缆沟及直埋地下,不能承受机械力YJ-交联聚乙烯绝缘Y-聚乙烯护套22- 钢带铠装聚氯乙烯护套32- 细钢丝铠装聚氯乙烯护套41- 粗钢丝铠装纤维护套43-粗钢丝铠装聚乙烯护套V-聚氯乙烯护套L-铝芯,无L为铜芯S-铜

5、丝金属屏蔽,无S为铜丝金属 屏蔽23- 钢带铠装聚乙烯护套33- 细钢丝铠装聚乙烯护套42- 粗钢丝铠装聚氯乙烯护套YJYYJLY交联聚乙烯绝缘聚乙烯护套电力电 缆同YJV型,电缆具有耐水、耐化学腐 蚀作用YJV22Y JLV22交联聚乙烯绝缘聚氯乙烯护套钢带铠 装电力电缆室内、隧道、电缆沟及地下,能承受机械外力作用,不能承受大的拉力YJV23Y JLV23交联聚乙烯绝缘聚乙烯护套钢带铠装 电力电缆同YJV22型,电缆具有耐水、耐腐 蚀作用YJV32YJLV32交联聚乙烯绝缘聚氯乙烯护套细钢丝铠装电力电缆高落差,立井及水下YJV33YJLV33交联聚乙烯绝缘聚乙烯护套细钢丝铠 装电力电缆同YJ

6、V32型,电缆具有耐水、耐腐 蚀作用YJV41YJV42 YJSV42Y JLV41Y JLV42YJSLV42交联聚乙烯绝缘聚氯乙烯护套(42) 或纤维外护层(41)粗钢丝铠装电 力 电缆需承受大拉力的立井及水中敷设YJV43Y JLV43交联聚乙烯绝缘聚氯乙烯护套粗钢 丝 铠装电力电缆同YJV42型,电缆具有耐水、耐腐 蚀作用电缆载流量1.110kv电缆载流量(1)电缆载流量确定条件线芯最高工作温度:90C ;短路温度:250r ;敷设环境温度:在空气中40C, 土壤中25C ;直埋敷设深度:100cm 土壤热阻系 数:1km/W聚氯乙烯 热阻系数:75 km/Wo(2) YLV及YJLV

7、型电缆载流量电缆类型标称截面2 mm电缆载流量/A在空气中(铜芯)直埋土壤中(铜芯)1203073350.6/1kv三芯电缆载流量1503533741854044242513514935164178501942086/10kv三芯电缆载流量70242255952933041203353431503803851854384372.3511Okv电缆载流量电缆载流量确定条件如下:导电线芯最高工作温度:90r ;空气敷设环境温度:30C ;直埋土壤温度:25r ;埋地深度:100cm单芯电缆三相水平布置,电缆间净距:7cm 土壤热阻系数:1km/W交联聚乙烯热阻系数:3.5km/W;聚氯乙烯热阻系数

8、:6km/W0适用电缆型号:YJSV,YJLSV3.矿用橡套软电缆的类型与主要技术特征矿用橡套软电缆的型号、名称、电压等级及用途型号电压/v名称用途型号含义UZ300/500矿用电钻电缆煤矿井下额定电压 300/500V及以下电钻的电源连接U-矿用Z-电钻P-屏敝Y-移动Q-轻型C-米煤机E-乙(丙橡皮绝缘)J-加强;监视B-铜线编织R-绕包加强型D-电灯,耐冻H-巷道,耐寒M-照明G-高压,工作面F-氯丁橡皮S-监视型型号后的数字-额定电压(V 或 KV)UZP300/500矿用屏蔽电钻电缆煤矿井下额定电压 300/500V及以下电钻的电源连接U660 或 1000矿用移动橡套软电缆煤矿井下

9、各种移动电气设备UP660 或 1000矿用移动屏蔽橡套软电缆煤矿井下各种移动电气设备UYQ300/500 或450/750矿用移动轻型橡套软电缆煤矿井下巷道照明、运输机联锁和控制与信号设备用电源连接UPQ1140千伏级矿用移动屏蔽橡套软电缆皮带运输机、转载机、刮板运输机等电气设备UY450/750矿用移动橡套软电缆煤矿井下用各种移动设备UYP660/1140矿用移动屏蔽橡套软电缆用于额定电压660/1140V的移动米煤设备的电源连接UC660 或 1000米掘机械用橡套软电缆井下各种采煤机及掘进机UCP380/660 或660/1140米掘机械用屏敝橡套软电缆煤矿井下各种米煤机及掘进机UCP

10、Q1140千伏级米煤机用屏蔽橡套软电缆(3主线芯)煤矿井下各种米煤机UCPQ114011芯千伏级米煤机用屏蔽橡套软电缆(6主线芯)煤矿井下各种米煤机UDGP1140金属屏蔽钢丝软铠装井下工作面照明电缆煤矿井下综米工作面照明电源连接UZHM300/500矿用照明电缆煤矿井下巷道照明线路UCJ1000钢丝加强型矿用橡套软电缆煤矿井下各种装岩机UGP100010KV矿用移动屏蔽橡套软电缆用于交流额定电压10KV以下,作为高压连接移动变电站及矿山采掘机械传输电能用。4.矿用橡套软电缆结构、参考外径及质量、允许载流量UZ UZP型电压等级300/500V矿用电钻电缆芯数X截面mrm电缆外径mm电缆质量K

11、g/km允许载流量/A动力线心地线芯控制芯UZUZPUZUZPUZUZP最小最大最小最大3X 2.51 X 2.517.819.619.821.9466690363 X 41 X 419.121.021.022.56403X 2.51 X 2.51 X 2.519.121.05513 X 41 X 41 X 420.522.6706注:电缆线芯和长期允许工作温度:65C ;环境温度:25CU,UP型电压等级1000V矿用移动橡套软电缆芯数X截面2 mm电缆外径mm电缆质量Kg/km允许载流量/A动力线芯地线芯UUPUUPUUP标称最大标称最大3X 41 X 420.722.823.726.16

12、06743363X 42 X 422.324.526.729.4723887363X 61 X 622.224.425.227.7744882463 X 101 X 626.529.229.532.610331233642 X 161 X 629.532.532.635.913371522853 X 251 X 1035.038.038.041.0196521411133 X 351 X 1037.340.341.544.8242225991383 X 501 X 1042.345.346.549.8318033571733 X 701 X 1648.551.951.555.142074440

13、215注:电缆线芯和长期允许工作温度:65 T ;环境温度:25EUYQ UY型电压等级300/500V矿用移动橡套软电缆芯数X截面2 mm电缆外径mm电缆质量Kg/km允许载流量/A动力线芯UYUYQUUPUUP标称最大标称最大2X 0.57.58.42X 0.758.08.92X 1.09.010.02X 1.510.311.52X 2.512.013.33X 0.57.98.83X 0.758.39.33X 1.09.410.43X 1.510.912.13X 2.512.714.0注:电缆线芯和长期允许工作温度:65C ;环境温度:25CUPC型电压等级1140V矿用移动屏蔽橡套软电缆

14、芯数X截面2 mm电缆外径mm电缆质量Kg/km允许载流量/A动力线芯地线芯最小最大3 X 101 X 103138.21327643 X 161 X 1033.841.21611853 X 251 X 1639.146.922661133 X 351 X 1641.449.426951383 X 501 X 1646.455.034501733 X 701 X 2552.961.445782153 X 951 X 2558.367.75642260注:电缆线芯和长期允许工作温度:65C ;环境温度:25CUYP型电压等级660/1140V矿用移动屏蔽橡套软电缆芯数X截面2 mm电缆外径mm电

15、缆质量Kg/km允许载流量/A动力线芯地线芯最小最大3 X 101 X 1033.135.91669643 X 161 X 1035.738.51966853 X 251 X 1639.843.026901133 X 351 X 1643.847.031221383 X 501 X 2550.153.443751733 X 701 X 3554.758.458492153 X 951 X 5061.965.67370260注:电缆线芯和长期允许工作温度:65 r ;环境温度:25rUDG型电压等级1140v金属屏蔽钢丝软铠装井下工作面照明电缆UZHh型电压等级300/500V矿用照明电缆芯数X

16、截面2 mm电缆外径mm电缆质量Kg/km允许载流量/A最小最大UDG型照明电缆2X 423.926.411953X 424.827.31378UZH輕电压等级300/500V矿用照明电缆3X 2.5+1 X 2.511.014.02453X 4+1 X 2.513.016.03503X 6+1 X 414.519.54753X 10+1 X 620.526.5910注:电缆导体长期允许工作温度:6 5 C。电缆最小弯曲半径 U D G 型为电缆直径的1 0倍,UZHh型为6倍UG.UGI型电压等级6000v橡皮护套电缆芯数X截面2 mm电缆外径mm电缆质量Kg/km允许载流量/A三线芯地线芯

17、标称最大UGUGF3X 61 X 640.344.318811966533 X 101 X 1043.848.723102402723 X 161 X 1646.851.528442948943 X 251 X 1649.354.2327833891213 X 351 X 1652.057.237973919148UGF理电压等级6000v矿用屏蔽橡套软电缆芯数X截面2 mm电缆外径mm电缆质量Kg/km允许载流量/A三线芯地线芯标称3X 61 X 643.12228533 X 101 X 1046.32631723 X 161 X 1649.33098943 X 251 X 1651.736

18、031213 X 351 X 1654.34148148矿用通讯电缆的类型及主要技术特征芯数X线径2mm电缆外 径mm电缆质量Kg/km芯数X线径2mm电缆外 径mm电缆质量Kg/km芯数X线径2mm电缆外 径mm电缆质量Kg/km芯数X线径2mm电缆外 径mm电缆质量Kg/km芯数X线径2mm电缆外 径mm电缆质量Kg/kmHUVV 型HUYV 型HUR型HUVVR 型HUVV29 型1 X 2X 7/0.287.12 X 2X 7/0.288.61 X 4X 7/0.288.05 X 2X 7/0.2811.57 X 2X 0.813.542205 X 2X 0.812.116010X 2

19、X 0.816.843147 X 2X 0.812.917414X 2X 0.818.6140710 X 2 X 0.814.023820 X 2X 0.821.5457020 X 2 X 0.817.639130 X 2X 0.825.0170830 X 2 X 0.822.351750 X 2X 0.832.2125750 X 2 X 0.827.981180 X 2X 0.843.0137680 X 2 X 0.834.41230100X 2X 0.848.91737100X 2 X 0.839.01547铜芯电缆的允许载流量怎样计算一平方铜线承受安全电流 ,一般都按 4A 电流计算 回答者:十下 5,百上 2,二五三五 43 界 ,铜线升级算 . 意思是十个平方以下的线 ,乘 5, 一百 平方以上的线乘 2 二十五以下乘 4 三十五以上乘 3 铜线按线径的上级算 ,如1.5 平方按 2.5算 这是工厂计算口诀 .很管用 . 回答者:估算口 诀:二点五下乘以九,往上减一顺号走。三十五乘三点五,双双成组减点五。条件有变加折算,高温九折铜升级。穿管根数二三四,八七六折满载流。说明:(1) 本节口诀对各种绝缘线 (橡皮和塑料绝缘线 )的载流量 (安全电流

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论