1、SSF隧道运营射流风机技术参数表机号极数流量(m3/s)出口风速(m/s)轴向推力(N)电机功率(KW)推力/功率(N/KW)6.32P14.646.91161.72249.42P12.038.5784.818.539.72P10.032.154515347.12P20.952.811753728.72P17.644.5833.23025.14P10.426.3287.87.544.94P7.118.0134.15.528.58.04P14.829.5463.91539.84P12.224.3315.21136.94P9.619.1219.047.537.69.04P21.133.274322
2、35.44P17.828.0528.818.5304P14.522.8350.91524.510.04P3338.61432.837364P29.735.91160.63035.54P26.533.89242238.54P23.329.780018.5406P20.025.5517.31547.26P16.721.3360.71144.911.24P40.741.41781.94539.14P37.437.71430.63738.24P33.834.41228.93040.54P30.631.2972.42243.74P28.428.9867.618.546.36P27.527.9814224
3、2.16P24.224.6630.41547.812.04P50.044.32348.24535.74P46.741.42048.53737.9机号极数流量(m3/s)出口风速(m/s)轴向推力(N)电机功率(KW)推力/功率(N/KW)12.04P43.138.217453039.84P39.935.41495.52246.56P33.829.91072.73039.36P30.226.7856.42242.812.54P56.546.12764.85534.24P53.243.42451.34537.14P49.643.02130.73739.26P38.2314.21262.93042.
4、46P34.928.51054.12248.214.06P53.734.91987.25533.76P50.432.81750.54540.56P47.230.71535.23743.46P4428.61334.13045.98P41.126.71163.93044.08P37.824.6984.52250.816.06P80.139.93390.19029.56P76.838.33116.57532.56P73.236.52831.25536.18P61.330.51985.65538.58P58.028.91777.64542.18P54.427.11563.83745.118.06P11
5、4.144.95430.313226.26P110.843.65120.711027.26P107.242.24793.49027.58P87.334.33180.511034.228P84.033.02944.69038.7五、SSF隧道运营射流通风机结构及安装尺寸图型号ABCDEEFGHd1d2n-d3重量(kg)6.310503782478560228-42450410946348944-136407.111834262792630276-48856811747149744-137838.013334803146710330-560640126480410644-139269.01500
6、5303530800280-648720137090411704-13107010.016776003954888450-7228001472100412724-15127011.218676724406990522-8168961584112413844-15150012.0192069045301023-2748479221617115614254-15162012.5200072047201065-2858829601684120414844-15170014.0233384055061243-345103611201884140416846-17260016.0266796062941
7、420-280119612802084160418846-17289018.03000108070801600-340135214402284180420846-173600六、安装、运行与维护1、射流风机预埋件对射流风机的准确安装和悬挂安全相当重要,所以应严格控制预埋件的质量。2、射流风机安装时不得磕碰及损坏风机,不得通过勾挂消音器来起吊风机,不得对风机施焊。3、安装风机时,应注意使风机上的风向标志与隧道的通风方向一致;并保证风机轴线与隧道的中心线平行。否则,将增加风能的额外损失。4、风机启动时,应检查风机内有无杂物,风机连接螺栓有无松动,叶片旋转方向是否与风机上的方向标志一致。5、风机启动
8、时,为减少对电网的冲击,应逐台启动风机,即一台风机达到额定转速后,方可启动下一台风机。6、射流风机正反向换向时,应等风机叶轮停稳后,再接通反向电源。7、风机无须特殊的维护保养工作,一般可定期擦拭风机外表面,对于风机上留有注油孔的,要定期加注电机轴在润滑油。8、定期清理消音板,避免网眼被灰尘堵死,影响消音效果。一、特点:高效、低噪、节能,“变极多速”以其不同的转速带给您不同的通风方式和节能效果,改变了传统叶片不可调的缺陷,实现了有选择的可调性并能适用于高原气候环境下的施工通风。二、风机型号表示方法:三、SDF(C)型隧道施工专用轴流通风机技术性能参数表:风机型号速度风量(m3min)风压(Pa)
9、高效风量(m3min)转速(r/min)最高点功率(KW)最大配用电机功率(KW)SDF(C)-No10高速770-1500550-35001225148071372中速640-1010240-160082598021.9122低速420-760140-8806197509.362SDF(C)-No11高速1015-1985624-415015501480107552中速690-1345295-1900109898033.5172低速540-1006160-10958257501582SDF(C)-No11.5高速1171-2285727-462918651480142.8752中速975-1
10、536317-2116125598044.0242低速639-1156185-116494175018.7122SDF(C)-No12.5高速1550-29121378-5355238514802081102中速1052-1968629-2445161098067.5342低速840-1475355-137512087502834162SDF(C)-No13高速1695-3300930-5920269114802591322中速1407-2219406-2704181398081452低速923-1670237-1487136075034222SDF(C)-No14高速2113-4116107
11、8-6860336114803601852中速1756-2771470-31362263980117602低速1152-2085274-1725169875050302四、SDF(C)型隧道施工通风机外型尺寸表 尺寸型号类别L1L2L3L4Lbb1DNo10C5305301050105044507806801190No10.5C5005001000100045007806801240No11C5505501100110049608807801290No11.5C6006001200120052608807801340No12.5C69069013801380563010009001450No1
12、3C69069013801380595010009001500No14C75075015001500628010809801600No15C75075015001500673010809801700No16C850850170017007180118010801800No17C850850170017007640118010801900No18C900900180018008080128011802000特点:SDF(A)型通风机具有风压高、噪音低、节能省电的特点;适用于地铁、引水工程以及石油管道工程等小断面作业,节能效果成为显著。SDF(A)型隧道施工专用对旋轴流通风机技术性能参数表:风机型
13、号风量(m3/min)风压(Pa)高效风量(m3/min)最高点功率(kW)最大配用电机功率(kW)SDF(A)-4.09014027514501073.32.22SDF(A)-5.018027543024002109.55.52SDF(A)-5.321432746425962501457.52SDF(A)-5.6250385540290032017.8112SDF(A)-6.0275432580460131127.9152SDF(A)-6.3286543610507336034.618.52SDF(A)-6.5303585640532039641.4222SDF(A)-7.134865576
14、0646051654.2302SDF(A)-7.5347757910675063571.3372SDF(A)-8.0385793980765069086.445243789511088160737107.3552SDF(A)-9.0548112912409080982145.67526221274140098801050170.3902一、特点:SDF(A)-I型风压高,噪音低,节能省电;SDF(A)-II型出口风速快、风量大、噪声音低、节能省电、易维修等特点。适用于地铁、引水工程以及石油管道工程等小断面作业尤为显著。二、SDF(A)型隧道施工专用轴流通风机技术性能参表:SDF(A)-型风机型
15、号风量(m3/min)风压(Pa)高效风量(m3/min)最高点功率(kW)最大配用电机功率(kW)SDF(A)-4.09014027514501073.32.22SDF(A)-5.018027543024002109.55.52SDF(A)-5.6250385540290032017.8112SDF(A)-6.0310480620340036025.1152SDF(A)-6.3450725685375054530.218.52SDF(A)-6.5500800720390060037.4222SDF(A)-7.1624999868476174554.2302SDF(A)-型风机型号风量(m3/
16、min)风压(Pa)高效风量(m3/min)最高点功率(kW)最大配用电机功率(kW)SDF(A)-5.31703131020366024214.57.52SDF(A)-5.62243511187400825317.8112SDF(A)-6.02754321363460131127.9152SDF(A)-6.33185001502507136034.618.52SDF(A)-6.53505501600540039641.4222SDF(A)-7.14567161900644251654.2302SDF(A)-7.55608802120718863571.3372SDF(A)-8.0652102
17、42412817873886.4452一、特点:根据用户要求可采用变频软启动,使风机实现了无极调速,可根据施工环境对风量、风压的不同要求进行调节,使一种功率的风机在不同功率下进行,真正实现了一机多用,从而有效节省了电能及投资,与传统启动方式比较可节省用电30%以上。二、风机型号表示方法:三、SDF(B)型隧道施工专用轴流通风机技术性能参数表:风机型号风量(m3/min)风压(Pa)高效风量(m3/min)转速(r/min)最高点功率(KW)最大配用电机功率(KW)SDF(B)-4-No9.6680-1325500-32001100148058302SDF(B)-4-No10770-150055
18、0-35001225148071372SDF(B)-4-No10.5891-1736606-38591418148085.5452SDF(B)-4-No111015-1985624-415015501480107552SDF(B)-4-No11.51171-2281727-462818631480135752SDF(B)-4-No12.51550-29121378-5355238514802161102SDF(B)-4-No131695-3300930-5920269114802591322SDF(B)-4-No142113-41161078-6860336114803001602SDF(B)
19、-6-No141399-2725473-31002226980110752SDF(B)-6-No151721-3352543-35592739980156902SDF(B)-6-No162088-4068618-40493323982061102SDF(B)-6-No172505-4879697-457139869802931602SDF(B)-6-No182973-5792782-512447319803892002四、SDF(B)型隧道施工通风机外型尺寸表 尺寸型号类别L1L2L3L4Lbb1DNo9.6B50050080080038007806801145No10B50050090090
20、041107806801190No10.5B500500100010045007806801240No11B5005001000100046608807801290No11.5B5505501100110049608807801340No12.5B69069013801380563010009001450No13B69069013801380595010009001500No14B75075015001500628010809801600No15B75075015001500673010809801700No16B850850170017007180118010801800No17B85085
21、0170017007640118010801900No18B900900180018008080128011802000SDF(A)隧道施工专用一、特点:SDF(A)型风压高,噪音低,节能省电;SDF(A)型出口风速快、风量大、噪音低、节能省电、易维修等特点。适用于地铁、引水工程以及石油管道工程等小断面作业尤为显著。二、风机型号表示方法:三、SDF(A)型隧道施工专用轴流通风机技术性能参数表:风机型号风量(m3/min)风压(Pa)高效风量(m3/min)最高点功率(KW)转速(r/min)SDF(A)-2-No4.090-140275-14501073.32900SDF(A)-2-No5.0
22、180-275430-24002109.52900SDF(A)-2-No5.6250-385540-290032017.82900SDF(A)-2-No6.0310-480620-340036025.12900SDF(A)-2-No6.3450-725685-375054530.22900SDF(A)-2-No6.5500-800720-390060037.42900SDF(A)-2-No7.1624-999868-476174554.22900四、SDF(A)型隧道施工专用轴流通风机外形尺寸风机型号d1(mm)d2(mm)d3(mm)L(mm)SDF(A)-2No4.048640563117
23、30SDF(A)-2 No5.06005057132531SDF(A)-2 No5.66845657702835SDF(A)-2 No6.07206058103037SDF(A)-2 No6.37566358403188SDF(A)-2 No6.57806558603291SDF(A)-2 No7.18507159503594FBDC系列抽出式对旋局部通风机一、概述FBDC系列抽出式对旋局部通风机(以下简称通风机)是淄博风机厂有限公司针对目前部分煤矿需要抽排含瓦斯及污风的需要(瓦斯浓度不超3)研制生产的最新节能型局部通风机。FBDC系列抽出式对旋局部通风机具有结构紧凑、噪声低、高风压、大流量、
24、效率高等特点。根据不同的通风要求,既可对旋使用,又可单机使用。使用对旋式通风时可增加通风距离,离较短时可使用单机,风量不变,从而减少能耗,节约能源。其结构紧凑,便于在工程施工中运输和安装使用。其结构型式为矿用隔爆型、对旋式、带消音装置、抽出式局扇通风机。二、用途FBDC系列抽出式对旋局部通风机适用于煤矿井下含爆炸性物质(瓦斯和煤尘)的环境中。作抽出式局部通风,可满足矿山通风网络和安全生产的需要。抽排井下局部瓦斯积聚或与除尘装备联合使用排除工作面粉尘,改变工作环境,是抽出式局部通风的理想装备。1型号、规格FBDC系列抽出式对旋局部通风机包括了l9个机号,标准状态下空气动力性能参数见表1。表1 F
25、BDC系列抽出式对旋局部通风机标准状态下空气动力性能参数序号型号规格/N功率(kw)风量(m3/min)静压(Pa)电压(V)最高静压效率(%)噪声LSA(dB)14/21.121.192-47142-1600380/660或660/1140602524/21.521.5111-56162-1810602534/22.222.2136-72241-2021602544/2323115-86341-2126602555/2424174-102231-2203602565/25.525.5200-100220-2773602575/27.527.5245-155380-3310602585.6/2
26、7.527.5270-124354-3865652595.6/211211330-186350-42506525105.6/215215395-250400-43006525116.3/215215420-240350-50006525126.3/218.5218.5486-236359-50106525136.3/222222510-310400-51006525146.3/230230620-320688-55466525157.1/230230540-391603-55386525167.1/27.527.5450-230273-41606525178.2/2372371037-4228
27、48-45606525188.2/215215519-265364-236365251910/4304301224-612945-287665252型号的组成及其代表意义三、结构特征与工作原理1总体结构FBDC系列抽出式对旋局部通风机由集风器、机壳、电动机、叶轮、扩散筒、风筒接头等部分组成(见图1)。通风机外壳及结构件用钢板焊接而成,内筒用孔板焊接而成,内衬消声材料:电动机被密封在内尺道内,与风道内的乏风隔离,电动机为YBF系列隔爆型风机用二极三相异步电动机采用380V/660V电压等级,通风机叶轮采用特殊材料制作,防静电、无摩擦火花。由电机冷却风轮所输送的气流进行冷却,电机与新鲜风流相通。因
28、此,该通风机可作井下抽出式通风使用。1 集风器 2前机壳 3级电动机4级叶轮 5级电动机 6级叶轮 7扩散器 8风筒接口图1 FBDC型抽出式对旋局部通风机结构示意图2工作原理通风机采用对旋式结构,风压高、效率高。在叶轮的作用下,乏风由集风器或进风接头吸入,经两级叶轮加压后送入回风巷或经导风筒排入回风巷,通风机流道中乏风不接触电动机。通风机结构紧凑,使用安全,维修方便。采用专用防爆电动机,电动机散热腔保证电动机散热良好,使电动机始终运行在新鲜风流中。四、性能参数标准状态下空气动力性能参数见表1。五、安装及调试FBDC系列抽出式对旋局部通风机设有地脚支架和悬吊孔,既可安装在巷道中的地面使用,也可
29、悬挂使用。1组装前,应严格检查叶轮与外壳,径向间隙,要求四周间隙均匀,保证在叶轮直径的0.15-0.3 5之间。2组装后,检查轮毂距法兰端面距离,不得小于2mm。3叶轮的旋转方向必须符合机壳,上方向标志所指的方向。4该风机必须由专人管理、操作。5该风机的安装和使用必须符合“煤矿安全规程”的有关规定。六、使用说明为保证通风机的长期安全运行,须注意正确使用和经常性的维护保养。掘进巷道采用抽出式通风机进行混合式通风时应符合煤矿安全规程的有关规定。通风机前应设置安全风窗,启动通风机前先打开安全风窗,运转正常后,逐渐关闭安全风窗。启动通风机前应检查通风机和开关附近1 0 m以内的瓦斯含量,瓦斯浓度不超过
30、0.5时,方可启动通风机,若瓦斯超限应采取相应的措施。通风机在运行中因故障停止运转,重新启动前,应检测风简内瓦斯浓度,若瓦斯浓度超标,应按煤矿安全规程规定处理。七、运输、贮存通风机在不使用时,应放置在空气流通、干燥的地方,防止电动机受潮及整机腐蚀和其它损坏:若电机受潮,必须进行干燥处理。一般为整机运输若需拆开运输,应保证不损伤通风机各部件。淄博金河风机有限公司主要产品:煤矿主扇风机,矿井风机,矿用主扇风机,矿用局扇风机,煤矿通风机,矿山风机等,提供煤矿主扇风机价格,是煤矿主扇风机厂家,欢迎新老客户朋友前来洽谈惠顾,FBCZ系列煤矿防爆抽出式轴流通风机FBCZ系列(原BK54、BK55系列)风机是结合中小型煤矿的通风网络参数研制成功的煤矿防爆轴流通风机,具有高效、节能、低噪声的优点,是中小型煤矿专用作为主扇的风机。该风机所用的材料,已通过了中国煤炭科学院重庆分院检测中心的摩擦火花试验,并达到了防爆要求,整机防爆性能已通过了国家防爆电器产品质量检测中心的防爆检验。主要特点:1、采用电动机与叶轮直联的风机最简结构,改变了当前煤矿抽出式轴流通风及全部采用皮带传动或长轴传动的复杂结构,利于运行和维修。2、该风机在电机外面安装全封闭型并具有一定耐压强度的密闭散热罩及气压平衡管,使电机始终处于无瓦斯空气之中运行,达到了煤矿有关防爆规程的要求。3、该系列风机为单级工作轮结构
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 【正版授权】 ISO/TR 24332:2025 EN Information and documentation - Blockchain and distributed ledger technology (DLT) in relation to authoritative records,records systems and records man
- 《工伤事故管理办法》课件
- 《服装品牌设计策划》课件
- 单位管理制度集合大合集【职工管理篇】
- 单位管理制度集粹汇编【员工管理篇】十篇
- 《学前儿童的注意》课件
- 单位管理制度合并汇编职工管理篇十篇
- 单位管理制度分享合集人力资源管理十篇
- 单位管理制度范文大合集人事管理十篇
- 单位管理制度范例合集【职员管理】
- 手术室护理组长竞聘
- 电力系统继电保护试题以及答案(二)
- 小学生防打架斗殴安全教育
- 2024-2025学年九年级英语上学期期末真题复习 专题09 单词拼写(安徽专用)
- 网络运营代销合同范例
- 2024年新人教版七年级上册历史 第14课 丝绸之路的开通与经营西域
- 《临床放射生物学》课件
- 植保无人机安全飞行
- 2024年10月自考04532财务会计专题试题及答案含解析
- 医疗纠纷事件汇报
- 2024年村干部个人工作总结例文(3篇)
评论
0/150
提交评论