1、电气工程学院 2021-8-9 2 Distance Relay 距离保护 Undervoltage Relay 低电压保护 Overvoltage Relay过电压保护 Blocking Relay闭锁继电器 Phase Angle or Out of Step Relay失步保护 Frequency Relay频率继电器 Directional Power Relay方向功率继电器 Instantaneous Overcurrent Relay瞬时过流保护 Differential Relay差动保护 2021-8-9 3 Grounding System Formerly, many p

2、ower systems were ungrounded systems using delta-delta transformers. Ungrounded systems suffer form several problems, including transient overvoltages that necessitate the use of two surge arresters for a single-phase transformer (one on each side of the winding), and trouble with rapid, automatic c

3、learing of the very common phase to ground short circuit. 以前,许多电力系统采用角型接线变压器,为不接地系统。 不接地系统会带来很多严重的问题,包括暂态过电压,因 此,即使是单相变压器,也需要分别在原边和副边绕组各 安装一个避雷器。而且对于非常常见的相接地故障的快速 自动切除非常困难。 2021-8-9 4 An ungrounded system is connected to ground only by stray capacitances, so a single phase to ground short circuit dr

4、aws very little fault current. 不接地系统通过隔离电容接地,因此单相接地故障会产生 非常小的故障电流 To allow rapid detection and automatic clearing of ground faults, and to reduce insulation and arrester costs, grounded systems have become more common than ungrounded ones. 为了快速检测和清除接地故障,并且降低投资在隔离设备 和避雷器上的费用,接地系统的应用越来越广泛。 2021-8-9 5

5、In many cases, the power transformers in a grounded system are connected delta wye, with the wye neutral grounded to the substation ground mat. 很多情况下,接地系统中的电力变压器的连接方 式为三角星型接线,星型接线的中性点和变电站 的接地网相连。 Generators and step-down transformers serving only three-phase loads are often grounded through a resist

6、ance to limit the ground fault current to low values. 发电机和只带三相负荷的降压变压器一般通过电 阻接地,以降低接地故障电流的大小。 2021-8-9 6 Generator step-up transformers and step-down transformers serving four-wire distribution system are usually connected delta on the primary and wye on the secondary. Remember primary means input a

7、nd second means output, so a step-up transformer primary is the low-voltage side but a step-down transformer primary is the high-voltage side. 发电机 升压变压器和向四线配电系统供电的降压变压器通 常在原边侧为三角型连接,在副边侧位星型链接。需要注 意的是原边指输入,副边指输出,因此升压变压器的原边 为低压侧,但降压变压器的原边为高压侧。 2021-8-9 7 Distribution transformers on four-wire systems

8、are connected phase to neutral (single phase) or wye (three phase) on the primary side. The secondary side of three-phase distribution transformers may be connected in either wye or delta. 四线系统的配电变压器的原边连接在相和中线上 (单相变压器)或连接成星型(三相变压器)。 三相配电变压器的副边可以星型或三角型连接。 2021-8-9 8 The wye-wye distribution transform

9、er is used for four-wire (three phase conductors and a neutral conductor) systems, and the wye-delta distribution transformer is usually connected with the bank neutral not connected to ground. 星星连接配电变压器用于四线系统(三相导线和 中线),星角接线配电变压器的中性点通常不接 地。 2021-8-9 9 If the neutral is grounded, the bank tries to gr

10、ound the feeder, and when ground faults occur on the primary side, the distribution banks will supply ground current. This usually causes a large number of blown fuses on wye-delta distribution transformers with grounded neutrals. 如果中性点接地,.,当在原边侧发生接地故障 时,配电变压器组中有接地电流流过。这会导致 星型中性点接地接线的配电变压器的保险熔断。 202

11、1-8-9 10 Floating the bank neutral alleviates the problem, but may cause overvoltage problems such as ferroresonance. Wye-wye banks avoid the ferroresonance problem since they invariably have grounded neutrals on both sides. 变压器中性点浮地能减轻这一问题,但可能造成 过电压问题,例如铁磁共振。星星连接变压器组 不会产生铁磁共振问题,因为在原边和副边中性 点均接地。 202

12、1-8-9 11 Instrument transformers 仪用(或测量用)互感器 Instrument transformers are the input transducer for protective relays, but also metering (both fro revenue metering and for data acquisition). The two main types of instrument transformers are current transformers (CTs) and potential transformers (PTs).

13、The latter are also called voltage transformers (VTs), with no difference intended. 测量用互感器指的是保护继电器的输入传感器,也指计量 仪表(例如电费计量和数据采集)的输入传感器。两种主 要的测量用互感器为电流互感器(CT)和电压互感器 (PT),后者也简称VT。 2021-8-9 12 The CT acts to step the current down, say from 1000A on the primary to 5A on the secondary. This would give a CT

14、ratio of 1000:5A or 200:1A, and would require 200 turns on the secondary (assuming one primary “turn”). CT的作用是降低电流,例如将原边1000A的电流 降至副边的5A。则CT的变比为1000:5A 或200:1A, 副边绕组的匝数为200(假设原边绕组匝数为1) 2021-8-9 13 Current transformer secondaries are typically rated at 5 A, although some are rated at 1 A. This is the

15、 continuous rating, and it may be exceeded by a factor of 10 or 20 for a short time, especially during a short circuit in supplying relays that provide overcurrent protection. 电流互感器二次侧典型额定电流为5A,有时为1A. 这只是额定标称值,其二次侧允许短时过电流10- 20倍,尤其是作为过流保护的输入传感器,有短 路电流流过时。 2021-8-9 14 Current transformers for relayin

16、g purposes are given accuracy class ratings, such as C400 or T400 (sometimes written as 10C400 or 10T400). The letter C indicates that its performance may be calculated from its magnetization curve. The letter T indicates that its performance must be determined by test. 保护用电流互感器均给出其(测量)精度等级, 例如C400或T400(有些标为10C400或10T400)。 字母C表示其特性通过其磁化曲线计算出来。字 母T 表示其特性由实验决定。 2021-8-9 15 The number following the letter C or T is the voltage rating: the secondary voltage produced by 20 times rated secondar

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论