1、GFI 350 Bar Internal Solenoid Tank Valve 350 BAR INTERNAL SOLENOIDTANK VALVEREFERENCE MANUALTV-2XX VALVESSpecifically designed for 350 bar Hydrogen, the IMPCO GFI solenoid operated internal tank valve provides enhanced storage system safety. Available in both 12 VDC and 24 VDC models. An integrated

2、temperature and pressure activated relief device ensures total system safety by ensuring tank protection.Note: Not all models exactly as shown.1CONFIDENTIALITYThe information contained in this document is confidential and proprietary to IMPCO Technologies Control Systems. This information cannot be

3、disclosed to other parties without written authorization from IMPCO Technologies. This document is intended only for customers engaged in a current confidentiality agreement with IMPCO Technologies.DISCLAIMERAlthough every effort has been made to provide complete and accurate information, IMPCO Tech

4、nologies cannot guarantee performance based solely on this document.Table of ContentsGFIP224 2014 IMPCO Technologies.Printed in CanadaGFI 350 BAR Internal Solenoid Tank Valve PHYSICAL DIMENSIONS2GAS SCHEMATIC AND SPECIFICATIONS4ELECTRICAL SCHEMATIC AND SPECIFICATIONS6TEMERATURE SENSOR7OPTIONAL CONNE

5、CTOR AND MATING CONNECTOR8PRESSURE RELIEF DEVICE (PRD)9MANUAL LOCKDOWN9DIAGNOSTICS10SERVIC CHECKS14SPECIAL TOOLS15APPLICATION CONSIDERATIONS162PHYSICAL DIMENSIONSThe internal tank valve is intended to fit into a standard 2-12 UN tank thread, with only 2” 50.8mm protruding beyond the neck of the tank

6、. To keep space requirements to a minimum, all connections are radial to the tank neck. Even the manual lockdown can be accessed from the side.Main materials in gas contact:- 6061-T6 aluminum- Glass-18-8 Stainless steel- 430F and FR Stainless steel- Nitrile- Dupont Vespel- Delrin- Copper wire, insul

7、ation- Heatshrink tubingWeight (w/o sensors): 1.925 lbs0.87 kgTank volume displaced:6.4cu. in.0.105 LInlet/Outlet ports:9/16-18 SAE J1926/1, -6 O-ringPRD Port7/16-20 UNFSAE J1926/1, -6 O-ringTank thread:2-12 UN3Minimum clearances inside the tank are given below. These are not a gland or tank design,

8、 but only designated minimum clearances.4GAS SCHEMATIC AND SPECIFICATIONSGENERALGas:HydrogenNominal pressure:5075 psi350 BargMax. overfill pressure.6350 psi438 BargMin. burst pressure:20,300 psi1400 BargOperating temperature:-40C to +85CCv, inlet to tank0.7Cv, inlet to outlet1.2FILLINGThe solenoid d

9、oes not need to be powered to fill. A pressure differential of about 2 bar (30 psi) opens the solenoid. It then acts as a check valve, preventing flow back out.The high pressure sensor reads pressure near the inlet, not inside the tank. At high fill rates, it reads higher than the pressure in the ta

10、nk, due to pressure losses through the valve.The temperature sensor reads the temperature of the gas inside the tank.RUNNINGEnergize the solenoid to open the valve.The high pressure sensor reads the tank pressure.Using the manual override tool has the same effect as using the solenoid.WARNING: Use o

11、f the manual override tool will damage the solenoid piston seal and the valve must be replaced. Return the damaged valve to IMPCO Technologies.CLOSEDSimilar condition exists if the manual lockdown is used.Only the PRD is connected to tank pressure. The PRD cannot be isolated from the tank pressure.T

12、he temperature sensor still reads gas temperature.The pressure sensor is not connected to the tank and could be removed if the lines are drained and the manual lockdown is closed.ELECTRICAL SCHEMATIC AND SPECIFICATIONSNominal voltage:12V24VMax. voltage:18V36VCurrent:1 ampTransient clip voltage:40VRe

13、sistance19.2 +/-5% ohms 20C71.82 +/-5% 20cDielectric Strength of coil 1000VRMS1000VRMSDuty Cycle Continuous Continuous6SOLENOIDThe solenoid is not polarity sensitive. A transient suppressor is installed to absorb the voltage spike that occurs when the solenoid is released. This keeps the reverse vol

14、tage spike down to 40 volts, for about 3 milliseconds. 7THERMISTORThe thermistor is on the pressure side of the valve, inside the tank. Because of this location the sensor reads the actual gas temperature at that point. However, under high flow conditions, temperature differences of over 30C have be

15、en measured between various points in the tank. This is something that must be tested in given tank setups. Sensor Supplier SpecificationsTYPENTCR25C2.7Kohms +/-2%Tolerance2%Thermal Time Constant10sThermal Dissipation2mW/CPower 25C.25WPower 85C1.25WOPTIONAL CONNECTOR AND MATING CONNECTORIMPCO Techno

16、logies can supply the tank valve (including temperature sensor) with either a 16” (40 cm) unterminated pigtail or with a standard connector on the end of 6” (15 cm) of wire. 9PRESSURE RELIEF DEVICE (PRD)The valve is equipped with a PRD, to vent the tank in the event of a fire. When the valve is expo

17、sed to excessive heat, the PRD opens and vents the tank through the vent port. Models are available with either 103C (217F) or 109C (228F). Model numbers ending in “0”, such as TV-110 are 103C, whereas those ending in “5” are 109C. The 103C (217F) contains cadmium, which is being phased out, while t

18、he other does not. IMPCO Technologies suggests that the non-cadmium version be used unless there is a legacy reason to do otherwise.The PRD is permanently connected to the interior of the valve. Because of this, it cannot be intentionally or unintentionally shut off.The PRD is capable of flowing abo

19、ut 200 grams per second of hydrogen, although actual flow rates will vary. The vent line should be sized to adequately handle this flow, and to guide it safely away. The line must also be protected from intrusion of water or other contamination.MANUAL LOCKDOWNThe valve includes a manual lockdown for

20、 service work, which shuts off all flow into and out of the tank. The lockdown is a 1/4 hex located on the face of the valve (see page 2 for diagram). It is normally turned counterclockwise to the fully open position. By turning it clockwise to 5.4 Nm 4ft-lbs, the only flow path into and out of the

21、valve (except the PRD) is closed. Opening the solenoid will have no effect.When any work is done on the valve or related lines, engage the manual lockdown. If any leaks are detected in the system, engage the manual lockdown.A separate tool is available to manually force the solenoid to open. This is

22、 only to be done when the solenoid has failed and is not capable of opening under power. Once the failure of the solenoid is confirmed, the lines into and out of the valve need to be emptied. The built-in manual lockdown is removed, and replaced with the manual override tool (see the Special Tools s

23、ection). This has the same effect as activating the solenoid. This should only be done if the solenoid cannot be opened normally, as it can damage the valve.The manual override tool should be used in accordance with the “06396-T Manual Override Tool Procedures” (Document # GFIP 258) supplied with th

24、e override tool, or available from IMPCO Technologies.WARNING: Use of the manual override tool will damage the solenoid piston seal and the valve must be replaced. Return the damaged valve to IMPCO Technologies.DIAGNOSTICS10If problems with the valve are suspected, the following checks should be don

25、e. The following procedures, however, assume no other problems with the system are causing issues. These tests should be incorporated into a system suppliers test procedures, and modified as needed for system effects.SYMPTOMS COVERED1) NO FLOW OF GAS WHEN VALVE ACTIVATED2) VALVE CONTINUES TO FAIL FU

26、SES OR BREAKERS.3) INCORRECT OR SUSPECT TEMPERATURE READINGS.4) APPARENT INTERNAL LEAK.5) VALVE APPEARS UNABLE TO CLOSE.PROCEDURES1) SYMPTOM: NO FLOW OF GAS WHEN VALVE ACTIVATED. There is no delivery of gas from the valve when the solenoid is activated. This procedure assumes that the related compon

27、ents in the system have either been verified or do not affect the test. Since not all possible system configurations can be considered in this document, refer to the system test procedures as appropriate. Special consideration should be placed on interactions from other valves plumbed with the valve

28、 in question. If possible, isolate the valve in question from others.1. Is the manual shutoff is in the open position?-Yes: Continue to step #2.-No: Open manual shutoff valve.2. Verify 12v or 24v signal sent from vehicle.Probe the solenoid supply terminals of the vehicle-side connector with a voltme

29、ter when a signal is expected from the vehicle. Although vehicle connectors and wires will differ, they should correspond to the white (12v models) or orange wires (24v models). Does it read 12 or 24 volts (as appropriate for vehicle) when expected?-Yes: Continue to step 3.-No: Diagnose vehicle prob

30、lem3.Verify resistance of valve connectors.Probe the solenoid pins of the valve connector with an ohmmeter. Depending on the voltage, these will either be orange or white. Resistance should be:-10-15 ohms lead to lead for a 12v coil or-40-60 ohms lead to lead for a 24v coil Valve and connector resis

31、tance correct, go to #4-lower than above values Probable solenoid short. Vent the tank using the manual override procedure and remove the valve per system supplier instructions and return to vendor.-Higher than above values: Verify the connector and wires have no obvious failures. If possible, remov

32、e wires from connector and verify again at terminals. Unless obvious problems can be found in the connector or wires, there is a probable valve failure. Vent tank using manual override procedure and remove valve per system supplier instructions and return to vendor.114.Verify resistance from the sol

33、enoid leads to the valve body with an ohmmeter. Ensure that the meter leads are not touching anything but the connector and body, including fingers.-Greater than 1Mohm, or “open line”: Correct, continue to step #5.-Less than 1Mohm Probable valve failure. Vent the tank using the manual override proce

34、dure and remove the valve per system supplier instructions and return to vendor5.Valve activation test.This test must only be done when the valve is in a condition that opening of the valve will not cause a hazardous condition! This must be ensured according to the system suppliers procedures. If po

35、ssible, a known good pressure gauge or sensor should be connected downstream of the valve without any unproven valves or other devices interfering with its function. Apply 12 or 24 volts to the valve (as appropriate for the model) from a known good power supply or battery, while listening for a clic

36、king noise.-click is heard or pressure rises downstream Normal function, no problem with valve.-No noise, and no rise in pressure. Probable failure of valve. Vent the tank using the manual override procedure and remove the valve per system supplier instructions and return to vendor-Clicking noise, b

37、ut no pressure rise. Ensure the tank is actually filled and that no other factors outside the valve are causing false readings. If nothing can be found, vent the tank using the manual override procedure and remove the valve per system supplier instructions and return to vendor.2) SYMPTOM: VALVE CONT

38、INUES TO FAIL FUSES OR BREAKERS. The fuse or breaker protecting the valve or valves frequently or constantly trips.1.Verify problem is with valves.Disconnect all valves and replace the fuse or reset the breaker. Power the solenoid supply in the normal manner, per system or vehicle procedures.-Fuse/b

39、reaker still trips. Vehicle or system problem-Fuse/breaker does not trip. Continue to step 2.2.Reconnect valves.Connect each valve in turn, and apply power. -Fuse/breaker trips Probable problem with that valve. Perform tests starting at step 2 of symptom 1.-Fuse/breaker does not trip. No trouble fou

40、nd. Problem may be intermittent.123) SYMPTON: INCORRECT OR SUSPECT TEMPERATURE READINGS. The vehicle is getting readings from the temperature sensor that are thought to be incorrect. The procedure below should work for most vehicle electronics, but steps 1 and 2 may differ on some vehicles.1. Verify

41、 the supply to the sensor.Disconnect the harness from the vehicle. Measure the voltage across the +5v and ground supply. Pinout and wire color depends on vehicle connector and harness, but +5v should correspond to the valves red wire, and 0V to the valves black wire.-reads +5v, within vehicles toler

42、ance. Voltage is correct, continue to step 2.-reads slightly different than +5v Possible vehicle voltage variation may lead to sensor reading variation, depending on vehicle electronics. This may or may not lead to a problem.-reads drastically different than +5v. Vehicle power supply or harness issu

43、es.2. Verify signal voltage.Connect +5v and ground to the red and black terminals of the valve connector. This can be accomplished by using jumpers or an intermediate connector to connect the valve connector to the vehicle harness, or by removing the signal terminal from either connector and connect

44、ing normally. Read the voltage between the sensor signal (green wire on valve) and ground (black wire). See the temperature sensor section of the manual for the voltage/temperature equation.-approximately 1.9 volts, depending on temperature. 0.4-3.4 can be expected over the operating range. Correct

45、voltage. No problem with valve. If problem persists, investigate vehicle for problems, or check for an intermittent problem.- values other than expected. Probable valve failure. If possible, remove wires from connector and verify again at terminals. Unless obvious problems can be found in the connec

46、tor, there is a probable valve failure. Remove the valve per system supplier instructions and return the valve to the vendor.4) SYMPTON: APPARENT INTERNAL LEAK. The pressure in the inlet/outlet line appears to rise, despite the valve being de-energized.Since leak testing is very dependant on the sys

47、tem configuration, verify the valve according to the system suppliers instructions. The manual shutoff can be used to isolate valves to aid in diagnosing. If trouble is found, remove the valve according to the system suppliers instructions, and return the valve to the vendor.5) SYMPTOM: VALVE APPEAR

48、S UNABLE TO CLOSE. The pressure in the lines stays high enough, despite de-energizing the coil, to suggest the solenoid is not closing.1. Perform click test. This test must only be done when the valve is in a condition that opening of the valve will not cause a hazardous condition! This must be ensu

49、red according to the system suppliers procedures. Repeatedly apply and remove 12 or 24 volts to the solenoid connector. An audible click should be heard on every activation and release. Repeat about 20 times.-No click is heard Probable solenoid failure. Remove the valve per system supplier instructi

50、ons and return the valve to the vendor.-Click heard every time. Valve is not stuck open. Check for leaks per #4.136) SYMPTON: APPARENT EXTERNAL LEAK. Indications of hydrogen leaking to the atmosphere is found. Using soap solution or other methods, verify the existence and source of the leak. If any

51、leak is found, consult with the system supplier. The manual shutoff can be used to isolate the tank from most of the plumbing, but it will not isolate leaks through the PRD or at the valve to tank interface.SERVICE CHECKS14These checks are only a general recommendation and should be incorporated in

52、a system check with due consideration for the system operation. Performing these checks without proper consideration for the system function may lead to incorrect or even hazardous results. 1. Visual inspection.-Check the valve for mechanical damage.-Look for signs of corrosion.-Check the wires for

53、chafing, burning, breaks or other damage.-If any damage is found that cannot be adequately repaired, the valve must be removed according to the system suppliers instructions. Wire or connector damage can generally be serviced in the field, but other problems generally require return to IMPCO Technol

54、ogies for repair.-The source of the damage must be investigated and resolved.2.Pressure test-Unplug or otherwise de-energize the solenoid.-Check and note the pressure in the outlet lines.-Per system or vehicle procedures, significantly reduce the pressure in the lines. Note the resulting line pressu

55、re.-Wait 10 minutes, and check the line pressure again. -The pressure should be close to what was measured after reducing the pressure. If it rises back to the initial pressure, an internal leak may have occurred. Proceed with diagnostic steps.-Without changing anything, proceed to step 3.3. Activation test-This should be done immediately after step 2.-Apply and remove power to the solenoid. -The pressure in the lines should rise to the

温馨提示

  • 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
  • 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
  • 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
  • 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
  • 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
  • 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
  • 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。

评论

0/150

提交评论