已阅读5页,还剩41页未读, 继续免费阅读
版权说明:本文档由用户提供并上传,收益归属内容提供方,若内容存在侵权,请进行举报或认领
文档简介
MASTER CONTRACT: 218317 REPORT: 1965853 PROJECT: 1965853 Edition 1:June 28, 2007; Project 1965853 TorontoPrepared by Contents:Certificate of Compliance - Page 1 Supplement to Certificate of Compliance - Page 1Descriptive Report and Test Results - Pages 1 to 80Illustrations - Ills 1 to 9Figures - Figs 1 to 14Attachment - Atts. A and BPRODUCTSCLASS 1211 05 - COMFORT CONDITIONING EQUIPMENT (ELECTRICAL) Air ConditionersCLASS 1211 85 - COMFORT CONDITIONING EQUIPMENT (ELECTRICAL) -CERTIFIED TO U.S. STANDARDSCentral Air Conditioners, ducted unit, permanently connected, consisting of an air cooled outdoor unit and a matching indoor unit, using refrigerant R410A, with model numbers and ratings shown as follows:PART A:Outdoor unit, BORA Model 24CHSRA, rated 208/230V, 60Hz, 1 phase.PART B:Outdoor unit, BORA Model 30CHSRA, rated 208/230V, 60Hz, 1 phase.PART C:Indoor unit, CARRIER Model FE4ANF005, rated 208/230V, 60Hz, 1 phase.APPLICABLE REQUIREMENTSCAN/CSA-C22.2 No.236-05-Heating and Cooling Equipment.UL Standad No.1995-Heating and Cooling Equipment.MARKINGSINDOOR UNIT: Not applicable. The indoor unit is an UL listed fan coil unit and is marked in accordance with UL certification report.OUTDOOR UNIT: A CSA Accepted or UL Recognized adhesive type nameplate Certified for outdoor use, is affixed to the outside of the cabinet bears the submittors name or file number 218317, model designation, date of manufacture, complete electrical rating in volts, hertz, number of phases, input ampere rating of each fan motors, RLA and LRA of the compressor, minimum circuit ampacity, Max. Over current Protection (Fuse or HACR Type Circuit Breaker): A”, quantity and type of refrigerant, the design high and low side pressures, and the CSA Monogram with the “C US” indicator.Caution Wording: WARNING: RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH:DISCONNECT ALL REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING. AVERTISSEMENT. RISQUE DE CHOCS ELECTRIQUES.PEUT CAUSER DES BLESSURES ET MEME ENTRAINER LA MORT. COUPER LES SOURCES DALIMENTATION A DISTANCE AVANT LE DEPANNAGE.The above caution wording may appear on a separate adhesive type nameplate affixed near to the main nameplate. Labels not affixed to removable cover unless otherwise specified.USE COPPER SUPPLY WIRES. UTILISER DES FILS DALIMENTATION EN CUIVREThe above caution wording appears on a separate adhesive type label near the main terminal block.The statement “for use with indoor unit, CARRIER MODEL FE4ANF005”.Suitable wiring diagram is provided on each unit (paper wiring diagram is affixed to the access panel inside surface).Suitable wiring diagram is provided on the unit.Installation operating manual is provided with each outdoor unit.Notes: 1. Jurisdictions in Canada may require these markings to be also in French. It is the responsibility of the customer to provide bilingual marking, where applicable, in accordance with the requirements of the Provincial Regulatory Authorities.2. The product may bear the CSA logo, or CSA with US indicator, or CSA with C US indicator.ALTERATIONS1. The markings are as noted above.FACTORY TESTS409613868. Dielectric Withstand Test: The equipment, upon completion of manufacture and before shipment, shall withstand, for not less than one second, without breakdown, the application of the following ac voltages, between live parts and exposed metal parts:(a)1,000V for units with a motor rated at less than 1/2 hp and rated 250V or less.(b)1,000V plus twice rated voltage for all other units.For units which include extra-low-potential circuits (30V or less), the test is to be conducted with the extra-low-potential circuit connected to the cabinet, chassis, or other dead metal part, so that the potential which is applied between the primary circuit and the exposed metal parts, is applied simultaneously between the primary circuit and the extra-low-potential circuit.(c)For units which include extra-low-potential circuits; 500V between the extra-low-potential circuit and exposed metal parts.Note: The test specified in Item (c) may be waived, if the extra-low-potential circuit is grounded or Class 2.409613869. Pressure Test for Refrigerant Leakage: At the completion of manufacture and before shipment, the complete refrigeration system of the equipment shall be tested and proved tight at pressures not less than the highest of the following:(a)The design pressures marked on the data plate for the device.(b)The minimum test pressures tabulated below.RefrigerantMinimum Design Pressure*Low SideHigh SidekPapsigkPapsig229931441917278500703102140020350211171622082302134a593861282186R407C11421662191318R410A16222353075446Notes:*A method other than pressure testing at the design pressure may be employed if it can be demonstrated that the alternative test method produces results that are at least equivalent to the pressure test method.The leakage test on the complete system may be conducted at the indicated low side pressure if final assembly of the equipment is completed with flare-type fittings or telescoped tubing joints that are sealed with silver solder, brazing, or equivalent means provided the high side parts are CSA Certified refrigerant containing component parts, or individually tested at not less than high side pressure indicated.Warning: The factory test(s) specified may present a hazard of injury to personnel and/or property and should only be performed by persons knowledgeable of such hazards and under conditions designed to minimize the possibility of injury.DESCRIPTIONThe description of each section is grouped as follow:SectionNumber.Description10Markings20Cabinet and metal enclosures30Non metallic enclosure and parts40Refrigeration system components50Compressors60Fan motors70Electrical components80Internal wiringAttachment DescriptionA. Installation manual of Bora outdoor units.B. Installation manual of Carrier fan coil indoor units.PRODUCT DECRIPTION:The products covered in report are central air conditioning systems each consisting of an outdoor unit made by BORA matched with an UL listed indoor fan coil unit made by Carrier as listed below:Outdoor Unit ModelMatching Indoor Unit Model24CHSRACARRIER Model FE4ANF00530CHSRAThese models each consists of a factory charged outdoor unit, which is joined in the field by electrical conduit and refrigeration tubing, to the indoor fan coil unit. The refrigerant for the total system is determined in the end installation.The outdoor unit and the indoor unit are permanently connected to its own separate power supply.Electrical interconnection between the indoor and outdoor units consists of extra low voltage control circuit wiring only.GENERAL REQUIREMENTS:Components are CSA Certified or UL Listed or Recognized, or accepted in the end product.ELECTRICAL SPACINGS:Unless otherwise noted in this Report, the spacings between uninsulated live parts of opposite polarity and between uninsulated live parts and dead-metal parts are not less than the following: Ratings Minimum spacing in. (mm) Volts-AmperesVoltsThrough AirOver SurfaceTo Enclosure2000 or less0 to 3001/8 (3.2)1/4 (6.4)1/4 (6.4)301 to 7503/8(9.6)(12.8)(12.8)More than 2000 0 to 3001/4 (6.4)3/8 (9.5)1/2 (12.7)INSTALLATION INSTRUCTIONS:Each unit is provided with installation and operating instructions. The installation instructions shall specify the maximum length of interconnecting tubing for field connection of condensing section and evaporating section.CORROSION PROTECTION:All ferrous metal parts used to support or retain electrical components in position are protected against corrosion by a zinc coating and painting.WIRING:Unless otherwise noted in this report, all wiring is CSA Certified or UL Recognized R/C AVLV2, min 18 AWG, suitable for a min of 300 V. It is installed and positively routed in such a manner that it is not subject to mechanical damage due to contact with sharp edges, abrasive surfaces, vibrating or moving parts. Wiring which is completely enclosed within metal conduit, metal raceways or other separate electrical enclosure employs 2/64 in (0.8 mm) thick min electrical insulation unless specified differently in this Report.Green or green with a yellow stripe may be employed only as grounding conductors. All routing of wiring through metal panels is made through holes provided with bushings with resilient rubber or holes for the passage of wires or cords through wall, panels or barriers having smooth, rounded surfaces. MARKINGS:All markings required to be permanent shall be molded, die stamped, paint stenciled, stamped or etched on permanently secured metal, or indelibly stamped or painted on pressure sensitive labels secured by adhesive. Pressure sensitive labels shall be CSA Accepted or UL recognized U/C PGDQ3, or R/C PGDQ2. For the outdoor units, the Pressure sensitive labels shall be approved for outdoor use. GENERAL CONSTRUCTION DESCRIPTIONPART A:Outdoor unit, BORA Model 24CHSRA.Installation instructions of the outdoor unit with the Carrier indoor unit to form a matched central AC system, is as shown in Attachment A.The matched AC system has attained a SEER rating of 13 (see EEV report 218317-1965855).The matched AC system has attained a Canadian HSPF rating of 6.7 (see EEV report 218317- 1965855).The matched AC system has attained a USA HSPF rating of 7.7 (see EEV report 218317- 1965855).10MARKING:See Ills 1 for details.10-10 Nameplate MarkingThe nameplate is permanently located at the right hand side of each unit and is visible and legible without requiring the use of tools for removal of panels, covers, etc. The nameplate includes the following information in addition to the submittors name. MaterialPolyester film, approved for outdoor use.Manufacturer:Yuhang City Hengbo Label Co. Ltd. or other certified equivalent sources, suitable where exposed indoors and outdoor.Designation:PGDQ2Location*:Outdoor cabinet.Secured byAdhesive label.Listees Name:BORA*Charge system per installation instruction.Main nameplate located on outdoor section. Outdoor unit must use nameplate Certified for outdoor use. Other Certified manufacturers nameplate of indoor and outdoor types may be used.Model Designation24CHSRADesign Pressure: High450 psig Low235 psigRefrigerant-factory charged: TypeR410A Amount (g/oz)3400/120Frequency60 HzPhase 1 phVoltage208/230VacTotal Current (A)9.4/8.6 Outdoor Fan Motor 0.5 Indoor Fan Motor 4.3 Compressor RLA 9.70/8.95 Compressor LRA34.8Minimum Circuit Ampacity15Maximum Fuse Size20Maximum Circuit Breaker Size (HACR type per NEC)2010-11Date Code:Location: Part of nameplate.Explanation of Date Code: The month, day and year are printed on the nameplate.10-20Special MarkingSee Ills.1 for details.A.TypeApproved Label suitable for outdoor use.ManufacturerVarious DesignationVariousLocationOutdoor units.Quote MarkingWARNING: RISK OF ELECTRIC SHOCK. CAN CAUSE INJURY OR DEATH:DISCONNECT All REMOTE ELECTRIC POWER SUPPLIES BEFORE SERVICING. AVERTISSEMENT. RISQUE DE CHOCS ELECTRIQUES. PEUT CAUSER DES BLESSURES ET MEME ENTRAINER LA MORT. COUPER LES SOURCES DALIMENTATION A DISTANCE AVANT LE DEPANNAGE.B.TypeApproved Label suitable for outdoor use. ManufacturerVarious DesignationVarious LocationOutdoor section, visible without toolsQuote Marking“USE COPPER SUPPLY WIRES. “UTILISER DES FILS DALIMENTATION EN CUIVRE.”C.TypeApproved Label suitable for outdoor use. ManufacturerVarious DesignationVarious LocationOutdoor section, visible without tools Quote Marking“For use with Indoor Unit, Carrier Model FE4ANF005.” on outdoor nameplate.10-30Wiring DiagramOptional See Ills 9 for details.LocationInside of service cover (outdoor unit).MaterialPaper and adhesive20 ENCLOSURE:20-10Ultimate Enclosure:Approx Physical Size (HWXD):High (mm):950Wide (mm):970Deep (mm):36020-20Unit Base Pan:Material:SteelThickness (mm):1.5Corrosion Protection (Method):PaintedBonding for Grounding (Method):Secured by screws to unit sides.20-30Unit Cabinet:Material:SteelThickness (mm):0.8Corrosion Protection (Method):PaintedBoding for Grounding (Method):Cabinet top cover is secured by at least two assembly screws engaged in extruded holes tapping to cabinet side plates.Cabinet right side plate is secured by at least two assembly screws engaged in extruded holes tapping to unit base pan.Cabinet left side plate is secured by at least two assembly screws engaged in extruded holes tapping to unit base pan.Cabinet front cover is secured by at least two assembly screws engaged in extruded holes tapping to unit base pan.Openings (Condenser Side Inlet):Type:Grill made of 3.0 mm steel wire rods.Rear Finned Area (HW) (mm):716720Side Openings (HW) (mm):17550Openings (Condenser Side Outlet):Type:Finned area with a grill made of 2.0 mm steel wire rods.Area (HW) (mm):590580Opening Size (mm):Max. 7.8 mm between wires.20-40 Control Box:Material:SteelDimensions (HWD) (mm):195316210Location:Below the unit top panel, above the compressor. (see Figs.7)Thickness (mm):0.8Corrosion Protection (Method):Galvanized steel.Bonding for Grounding (Method):Screws.Terminal Cover:Manufacturer:Various.Material:Galvanized steel.Dimensions (mm):200124124Thickness (mm):0.8Mounting:By screws to the box.Remarks:The sides of opening of the bottom entry passage are flanged so as to prevent damage to the wirings. (see Figs.9)20-50 Unit Top:Material:SteelThickness (mm):0.8Corrosion Protection (Method):PaintedBonding for Grounding (Method):Secured by screws to unit sides.20-60 Moving Parts Guarding:Remarks:See wire grill description in unit cabinet description (Item 20-30, condenser outlet opening).30NONMETALLIC COMPONENTS:Note: Other CSA certified or UL recognized plastic materials having the same flammability ratings may be used.30-10Terminal Cover:See Item 20-40 above for description.30-20 Condenser Fan Blades:Manufacturer:VariousMaterial (Including Facing):GFABS-20Flammability Rating:HBThickness (mm):0.8Means of Securing:ScrewsDiameter (mm):480Number of Blades:540REFRIGERATION SYSTEM:40-10Condenser:Illustration:Ills 4.Manufacturer:Ningbo Hengshan or Hangzhou HualingDesignation:24CHSRAO.002.00Number of Tubes High:21Number of Tubes Deep:2Physical Size, Finned Section (mm):Height:900Width:1003Depth:36.4No. of fins per inch:14-15Spacing between fins (mm):1.9Tubing Material:CopperTubing OD (mm):7.0Tubing Wall Thickness (mm):0.25Return Bend OD (mm)7Return Bend Thickness (mm)0.5Corrosion Protection:InherentBonding for Grounding (Method):Assembly screws.Certified/Accepted:Accepted, tested at design pressure of 500 psi.(3.44 Mpa).40-20Pressure Relief:Means provided:Soldered or brazed jointLocation:Tubing joints40-30 Interconnecting Tubing:Material:CopperOutside Diameter (mm):6.358.09.52, 7.0, 12.716.0Min Wall Thickness (mm):1.040-40Refrigerant Control:Thermal Expansion Valve Assembly: (Self-adjusted refrigerant pressure valve) Model: HCAE1.5ZX200B15 One for each outdoor unitManufacturer: SPORLAN USA.Capacity: 1.5RT (cooling capacity)Design Pressure (MPa.): 600psi Location: Between High pressure and Low pressure in condenser unit. Above the compressor but under the electrical box.40-50Refrigeration System Joints:Method of Joining:Soldering or brazing.40-60Refrigerant Tubing Fittings: Formed of forged brass.40-70High Pressure Limit Switch:CSA Accepted/ UL recognizedManufacturer:JiangShu ChangHeng GroupDesignation:QYK or 20PS SeriesPressure Rating:580 psiElectrical Rating:Volts:DC 12 VFLA:6.0ALRA:35.0ALoad controlled:Relay coilElectrical Location:In the control circuit of relay coil on the pcb between the transistor (Q2) and relay coil.Mechanical Location:At high side of system near compressorRemarks:No valve is located between the pressure relief means and the refrigerant containing component that is protected by the pressure relief means. A spacing of 1.6 mm is maintained between the printed conductors of this safety control circuit and all other printed conductors in the control circuit on the pcb.40-80Four Way Valve:CSA Accepted / UL recognized (UL SA11830 MH25894)Model:Used on heat pumps modelsPurpose:Reversing valveManufacturer:Zhejiang SanHua Group Corp UL No. SA11830 MH25894Coil Designation:AC220V+10%/-15% 50/60Hz Electrical Ratings:Volts:230Watts:6/5Valve Designation:SHF-9H-35UPressure Ratings:Max Operating Pressure:600 (4.15 Mpa)Differential, psig:450 (3.10 Mpa)Min Working Pressure, psig:50 (0.30 Mpa)Ambient Temperature Rating, Deg F:-4 to 131 (-20 to 55 deg C)Location: Right side of the unit (beside compressor)40-90Accumulator: CSA AcceptedModel: AllManufacturer: Ningbo HuafengDesignation: 24C
温馨提示
- 1. 本站所有资源如无特殊说明,都需要本地电脑安装OFFICE2007和PDF阅读器。图纸软件为CAD,CAXA,PROE,UG,SolidWorks等.压缩文件请下载最新的WinRAR软件解压。
- 2. 本站的文档不包含任何第三方提供的附件图纸等,如果需要附件,请联系上传者。文件的所有权益归上传用户所有。
- 3. 本站RAR压缩包中若带图纸,网页内容里面会有图纸预览,若没有图纸预览就没有图纸。
- 4. 未经权益所有人同意不得将文件中的内容挪作商业或盈利用途。
- 5. 人人文库网仅提供信息存储空间,仅对用户上传内容的表现方式做保护处理,对用户上传分享的文档内容本身不做任何修改或编辑,并不能对任何下载内容负责。
- 6. 下载文件中如有侵权或不适当内容,请与我们联系,我们立即纠正。
- 7. 本站不保证下载资源的准确性、安全性和完整性, 同时也不承担用户因使用这些下载资源对自己和他人造成任何形式的伤害或损失。
最新文档
- 2024-2030年包装广告产业规划专项研究报告
- 2024-2030年出版行业十四五竞争格局分析及投资前景与战略规划研究报告
- 2024-2030年全球及中国面部美学行业市场现状供需分析及市场深度研究发展前景及规划可行性分析研究报告
- 2024-2030年全球及中国运营业务流程即服务(BPaaS)行业市场现状供需分析及市场深度研究发展前景及规划可行性分析研究报告
- 2024-2030年全球及中国路由器和交换机行业市场现状供需分析及市场深度研究发展前景及规划可行性分析研究报告
- 2024-2030年全球及中国蛇麻草提取物行业销售模式及发展态势展望研究报告
- 2024年专业咨询服务型劳务合作合同范本
- 办公租赁合同:2024年高品质商务空间租赁
- 简单水电承包合同书
- 2024年神经系统用药项目评估分析报告
- 第4课《公民的基本权利和义务》(课件)-部编版道德与法治六年级上册
- 国开(甘肃)2024年春《地域文化(专)》形考任务1-4终考答案
- 《路由与交换技术》课程教学大纲
- 家庭电路的进户线示意图PowerPoint 演示文稿
- 多肉植物生长观察日记小报
- lampsite LTE 站点配置指导v1.1
- 市政工程钢筋混凝土管砂石基础垫层量计算公式
- 第七章 生态旅游标准与认证
- 输血科标准操作规程SOP文件
- 县人大常委会预算审查监督暂行办法
- 结肠代食道术护理体会
评论
0/150
提交评论